Code 252.276.10
CERAMIC-GLASS BOILING UNITS
Mod. 92 PCV
94 PCV
94 CFV
~

INDEX
Paragraph Installation instructions
1 Compliance with EEC directives
1.1 Installation drawings
1.2 Wiring diagrams
1.3 Technical data
1.4 Electrical specifications
2 Preliminary installation instructions
2.1 Regulations, technical rules and general specifications
2.2 Installation
2.2.1 Electrical connection
2.2.1.1 Equipotential
2.3 Safety devices
Paragraph User instructions
3 Start-up
3.1 Operating Instructions - Switching on and switching-off
4 Switching on the electric static oven
5 Maintenance, cleaning and care

INSTALLATION INSTRUCTIONS
Equipment reserved for private use only.
1. CONFORMITY WITH EEC DIRECTIVES
REMARK: The electric ranges are made in compliance with the basic requirements
envisaged by EEC directives, in accordance with “EEC Directive 73/23 on low voltage”, “EEC
Directive 89/336 on electromagnetic compatibility” and are marked “CE” according to the
EEC Directive 93/68.

1.4 ELECTRICAL SPECIFICATIONS:
Model
Rated voltage
Total power kW
Power cable
Cross section
Dimensions mm
Width
Depth
Height
92 PCV 94 PCV 94 CFV
400V – 3N~ 50 Hz
6,8 13,6 19,6
H05RN-F H05RN-F H05RN-F
5 x 2,5 mm2 5 x 4 mm2 5 x 6 mm2
450
900
250
900
900
250
900
900
850
The data plate contains all necessary information with installation and it is located on the
posterior part near the terminal block of the models.
2. PRELIMINARY INSTALLATION INSTRUCTIONS
The appliance must be positioned in a well-aired room, if possible under a hood to remove
cooking steam thoroughly.
Before starting the appliance, remove all protective film; thoroughly clean the surfaces with a
soft cloth, lukewarm water and detergent, so as to remove all anti-rust products applied
during the manufacturing stage, then dry with a clean cloth.
If the appliance is installed near walls, partition walls, kitchen furniture, decorative panelling,
etc., these should be constructed with fireproof materials or a space of at least 100 mm
should be left free.
Make sure that fire prevention rules are strictly respected.
According to the model our appliances can be floor standing or they can be installed on
cantilever support.
The main switch and the socket must be near the appliance and easily accessible.
Using the levelling feet lay the appliance flat, adjust the height and ensure its stability.
2.1 Regulations, technical rules and general specifications
Comply with the following rules during assembly:
1) accident prevention rules;
2) rules in force in the country where the appliance is installed;
3) carefully read this booklet as it contains important instructions about installation safety,
use and maintenance;
4) keep this booklet for further reference.