CAUTION: To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning.
• Read all instructions before installing.
• System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
• When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
• Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any
parts are damaged or missing.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in coastal
areas clean all external surfaces of the fixture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
• Lisez toutes les instructions avant l’installation.
• Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux
règlements locaux.
• Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la
garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
NOTE D’ENTRETIEN: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chiffon humide.
HARDWARE
A
Wire Connector
Qty: 3pcs+1 Extra
B
Mounting Screw
Qty:1 Extra
C
Rubber Gasket
Qty: 1 Extra
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2019
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
1
INSTALLATION INSTRUCTIONS
590- Outdoor Pendant
PD-W59016
PREPARATION
1. Shut off the power at the circuit breaker and remove existing
fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on
a clear area. Be careful not to lose any small parts necessary
for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) and rubber gasket (C) from
the fixture.
4. Secure the mounting back plate to the junction box using the
screws provided with the junction box.
Note: ( i ) using any other non-original-manufacturer provided
junction box screw may result in safty issue;
( ii ) The side of the mounting plate marked “GND” must
face out.
5. Choose number of rods suitable for your application.
6. Thread the fixture wire through the rods, swivel and canopy.
7. Connect the canopy,rods, swivel and lamp body,Make sure all
are tightened.
CONNECTING THE WIRES (Fig. 2)
8. Connect the fixture’s wires to junction box wires as shown in
Fig. 2, making sure that all wire connectors (A) are secured.
If your outlet box has a green or bare copper ground wire,
connect the fixture’s ground wire to it. Otherwise, connect the
fixture’s ground wire directly to the back plate using the green
screw provided. After wires are connected, tuck them carefully
inside the junction box.
COMPLETING THE INSTALLATION
9. Secure the fixture to the mounting back plate using the
mounting screw (B) and the rubber gasket (C).
10. For slope ceiling application, rotate swivel at the top of the stem
to ensure luminaries is aiming down (Fig.3).
11. To prevent moisture from entering the outlet box and causing
a short, use clear caulking (i.e. indoor/outdoor silicone sealant)
to outline the outside of fixture back plate where it meets the
wall. Leave a space at the bottom to allow moisture to escape (Fig.4).
FIG. 1
A
Wire Connector
Mounting Screw
B
C
Rubber Gasket
3 x 12" Rods
FIG. 2 Wiring
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
Junction Box
White Wire
Black Wire
Mounng Back Plate
Junction Box Screw
Cannopy
Swivel
1x 6" Rod
Lamp Body
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
PD-W59016 Back Plate
FIG.3
FIG.4 Sealing
Junction Box
Caulking
1 3/4” 1 3/8”
Turn to down
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2019
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
4 5/8”
2