IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1B1C1D1E1
Wire Connector
Qty: 3 pcs + 1 Extra
7EAC112201
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Junction Box Screw
Qty: 2 pcs + 1 Extra
7MPF0415C2
#8-32x9/16
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Mounting Screw
Qty: 1 Extra
7MPF0406C3
5/32"-32X1/4
Nickel Plating
Wood Screw
Qty: 3 pcs + 1 Extra
7MPF2204J2
Ø4x22mm
Nickel Plating
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Plastic Anchor
Qty: 3 pcs + 1 Extra
7TDD082401
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 2
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41703R
PREPARATION
1. Shut o the power at the circuit breaker and remove existing
xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a
clear area. Be careful not to lose any small parts necessary for
installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove the mounting screws (C1) from the xture.
4. Install the mounting back plate to the junction box using
junction box screws (B1)
5. Mark the three wood screw mounting holes on the ceiling,
remove mounting back plate, drill holes and insert the three
plastic anchors (E1)
6. Adjust the xture wire length by pushing the cable gripper on
the canopy and pulling the wire as desired.
7. Connect the driver input wires with supply wires as shown in
Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire,
connect the xture’s ground wire to it. Otherwise, connect the
xture’s ground wire directly to the mounting plate using the
green screw provided. After wires are connected, tuck them
carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
8. Install mounting plate back to the junction box using junction
box screws (B1), fasten it to the ceiling using the three wood
screws (D1). The side of the mounting plate marked “GND”
must face out.
9. Push the xture onto the mounting back plate, and secure it
with mounting screws (C1).
FIG. 1
Wire Connector
Wood Screw
Driver
D1
A1
Junction Box
Ground Wire
E1
Plastic Anchor
Mounting Back Plate
B1
Junction Box Screw
C1
Mounting Screw
Cable Gripper
Fig. 2 Wiring
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
Back Plate Dimensions
8 7/8"
1 5/8"
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
3 1/2"
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Lamp Body
Crystal Glass
(RPL-GLA-41719)
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 3
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41705R
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1B1C1D1E1
Wire Connector
Qty: 3 pcs + 1 Extra
7EAC112201
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Junction Box Screw
Qty: 2 pcs + 1 Extra
7MPF0415C2
#8-32x9/16
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Mounting Screw
Qty: 1 Extra
7MPF0406C3
5/32"-32X1/4
Nickel Plating
Wood Screw
Qty: 3 pcs + 1 Extra
7MPF2204J2
Ø4x22mm
Nickel Plating
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Plastic Anchor
Qty: 3 pcs + 1 Extra
7TDD082401
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 4
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41705R
PREPARATION
1. Shut o the power at the circuit breaker and remove existing
xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a
clear area. Be careful not to lose any small parts necessary for
installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove the mounting screws (C1) from the xture.
4. Install the mounting back plate to the junction box using
junction box screws (B1)
5. Mark the three wood screw mounting holes on the ceiling,
remove mounting back plate, drill holes and insert the three
plastic anchors (E1)
6. Adjust the xture wire length by pushing the cable gripper on
the canopy and pulling the wire as desired.
7. Connect the driver input wires with supply wires as shown in
Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire,
connect the xture’s ground wire to it. Otherwise, connect the
xture’s ground wire directly to the mounting plate using the
green screw provided. After wires are connected, tuck them
carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
8. Install mounting plate back to the junction box using junction
box screws (B1), fasten it to the ceiling using the three wood
screws (D1). The side of the mounting plate marked “GND”
must face out.
9. Push the xture onto the mounting back plate, and secure it
with mounting screws (C1).
FIG. 1
Wire Connector
Wood Screw
D1
A1
Junction Box
Ground Wire
E1
Plastic Anchor
Mounting Back Plate
B1
Junction Box Screw
C1
Mounting Screw
Driver
Cable Gripper
Fig. 2 Wiring
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
Back Plate Dimensions
14 3/4"
3 1/2"
1 5/8"
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Lamp Body
Crystal Glass
(RPL-GLA-41719)
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 5
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41709R
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1B1C1D1E1
Wire Connector
Qty: 3 pcs + 1 Extra
7EAC112201
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Junction Box Screw
Qty: 2 pcs + 1 Extra
7MPF0415C2
#8-32x9/16
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Mounting Screw
Qty: 1 Extra
7MPF0406C3
5/32"-32X1/4
Nickel Plating
Wood Screw
Qty: 3 pcs + 1 Extra
7MPF2204J2
Ø4x22mm
Nickel Plating
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Plastic Anchor
Qty: 3 pcs + 1 Extra
7TDD082401
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 6
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41709R
PREPARATION
1. Shut o the power at the circuit breaker and remove existing
xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a
clear area. Be careful not to lose any small parts necessary for
installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove the mounting screws (C1) from the xture.
4. Install the mounting back plate to the junction box using
junction box screws (B1)
5. Mark the three wood screw mounting holes on the ceiling,
remove mounting back plate, drill holes and insert the three
plastic anchors (E1)
6. Adjust the xture wire length by pushing the cable gripper on
the canopy and pulling the wire as desired.
7. Connect the driver input wires with supply wires as shown in
Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire,
connect the xture’s ground wire to it. Otherwise, connect the
xture’s ground wire directly to the mounting plate using the
green screw provided. After wires are connected, tuck them
carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
8. Install mounting plate back to the junction box using junction
box screws (B1), fasten it to the ceiling using the three wood
screws (D1). The side of the mounting plate marked “GND”
must face out.
9. Push the xture onto the mounting back plate, and secure it
with mounting screws (C1).
FIG. 1
Wire Connector
Wood Screw
D1
A1
Junction Box
Ground Wire
E1
Plastic Anchor
Mounting Back Plate
Junction
B1
Box Screw
C1
Mounting Screw
Driver
Cable Gripper
Fig. 2 Wiring
Back Plate Dimensions
14 3/4"
3
5/8"
5
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
1/2"
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Lamp Body
Crystal Glass
(RPL-GLA-41719)
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 7
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41715R
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1B1C1D1E1
Wire Connector
Qty: 3 pcs + 1 Extra
7EAC112201
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Junction Box Screw
Qty: 2 pcs + 1 Extra
7MPF0415C2
#8-32x9/16
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Mounting Screw
Qty: 1 Extra
7MPF0412C1
5/32"-32X1/2
Nickel Plating
Wood Screw
Qty: 6 pcs + 1 Extra
7MPF2204J2
Ø4x22mm
Nickel Plating
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Plastic Anchor
Qty: 6 pcs + 1 Extra
7TDD082401
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 8
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41715R
PREPARATION
FIG. 1
1. Shut o the power at the circuit breaker and remove
existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the
parts on a clear area. Be careful not to lose any small
parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove the mounting screws (C1) from the xture.
4. Install the mounting back plate to the junction box using
junction box screws (B1)
5. Mark the six wood screw mounting holes on the ceiling,
remove mounting back plate, drill holes and insert the six
plastic anchors (E1)
6. Adjust the xture wire length by pushing the cable gripper on
the canopy and pulling the wire as desired.
7. Connect the driver input wires with supply wires as shown in
Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire,
connect the xture’s ground wire to it. Otherwise, connect the
xture’s ground wire directly to the mounting plate using the
green screw provided. After wires are connected, tuck them
carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
8. Install mounting plate back to the junction box using junction
box screws (B1), fasten it to the ceiling using the six wood
screws (D1). The side of the mounting plate marked “GND”
must face out.
9. Hook the two safety cords to the mounting plate
10. Push the xture onto the mounting back plate AND rotate
the xture until it is docked in position, and secure it with
mounting screws (C1).
Fig. 2 Wiring
Fixture Wires
Black or
Smooth
House Wires
Black
(Hot)
ROTATE
Wire
Connector
PUSH
A1
Junction Box
Ground Wire
Plastic
E1
Anchor
Junction
B1
Box Screw
Mounting
Back Plate
Wood
D1
Screw
Safety Cable
Mounting
C1
Screw
Driver
Cable Gripper
Lamp Body
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
Back Plate Dimensions
20 5/8"
16 3/4"
1
3/4"
1
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
3/8"
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
20 3/8"
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Crystal Glass
(RPL-GLA-41719)
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 9
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41721R
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1B1C1D1E1
Wire Connector
Qty: 3 pcs + 1 Extra
7EAC112201
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Junction Box Screw
Qty: 2 pcs + 1 Extra
7MPF0415C2
#8-32x9/16
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Mounting Screw
Qty: 1 Extra
7MPF0412C1
5/32"-32X1/2
Nickel Plating
Wood Screw
Qty: 6 pcs + 1 Extra
7MPF2204J2
Ø4x22mm
Nickel Plating
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Plastic Anchor
Qty: 6 pcs + 1 Extra
7TDD082401
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 10
INSTALLATION INSTRUCTION
417 - LED Pendant
PD-41721R
PREPARATION
FIG. 1
1. Shut o the power at the circuit breaker and remove
existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the
parts on a clear area. Be careful not to lose any small
parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove the mounting screws (C1) from the xture.
4. Install the mounting back plate to the junction box using
junction box screws (B1)
5. Mark the six wood screw mounting holes on the ceiling,
remove mounting back plate, drill holes and insert the six
plastic anchors (E1)
6. Adjust the xture wire length by pushing the cable gripper on
the canopy and pulling the wire as desired.
7. Connect the driver input wires with supply wires as shown in
Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire,
connect the xture’s ground wire to it. Otherwise, connect the
xture’s ground wire directly to the mounting plate using the
green screw provided. After wires are connected, tuck them
carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
8. Install mounting plate back to the junction box using junction
box screws (B1), fasten it to the ceiling using the six wood
screws (D1). The side of the mounting plate marked “GND”
must face out.
9. Hook the two safety cords to the mounting plate
10. Push the xture onto the mounting back plate AND rotate
the xture until it is docked in position, and secure it with
mounting screws (C1).
Fig. 2 Wiring
Fixture Wires
Black or
Smooth
House Wires
Black
(Hot)
ROTATE
Wire
Connector
PUSH
A1
Junction Box
Ground Wire
E1
Plastic Anchor
Mounting Back Plate
B1
Junction Box Screw
D1
Wood Screw
Safety Cable
C1
Mounting Screw
Driver
Cable Gripper
Lamp Body
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
Back Plate Dimensions
1
19 3/4"
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
3/4"
23 5/8"
1
3/8"23 1/2"
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Crystal Glass
(RPL-GLA-41719)
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.