Modern Forms NDNH1113, MFDE1321 Installation & Assembly

Page 1
INSTALLATION INSTRUCTION
Kinetic - LED Pendant
PD-61728, PD-61738
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture. CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1 B1 C1 D1 E1
Wire Connector
Qty: 5 pcs + 1 Extra
7EAC112201
P3
modernforms.com
Phone (800) 526.2588 Fax (800) 526.2585
Junction Box Screw Qty: 2 pcs + 1 Extra
7MPF0820C1 #8-32x13/16”
SS
Headquarters/Eastern Distribution Center
44 Harbor Park Drive Port Washington, NY 11050
Driver Screw
Qty: 1 Extra
7MPF0405C1 5/32-32x3/16” Nickel Plating
Metal Gasket
Qty: 1 Extra 7MPH1005A1 Ø10x1.24mm Nickel Plating
Central Distribution Center
Mounitng Screw
Qty: 1 Extra
4MPF041502PM
5/32-32x 9/16”
Paint PM
Western Distribution Center
1750 Archibald Avenue Ontario, CA 91760
Fixture Cap
4MBA280501PM
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 2
INSTALLATION INSTRUCTION
Kinetic - LED Pendant
PD-61738
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove the mounting screws (E1) from the xture. Disconnect the Driver’s output wire. Remove the driver screw (C1) and metal gasket (D1).
4. Secure mounting back plate to the junction box using junction box screws (B1). The side of the mounting plate marked “GND” must face out. Pull out the driver output wire.
5. Connect the driver input wires with supply wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the mounting plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
6. Choose the number of down rods suitable of your application.
7. Thread the xture wire through the rods, swivel and canopy. Connect the canopy, swivel, rods and xture body. Make sure all are tightened.
8. Connect the driver output wires with xture wire as shown in Fig. 2, making sure that all wire connectors (A1) are secured. secure the driver with driver screw (C1) and metal gasket (D1).
9. Place the xture over the mounting back plate and secure it with mounting screws (E1).
10. For slope ceiling application, rotate swivel at the top of the stem to ensure luminaries is aiming down (Fig. 3)
11. The lamp ring can rotate 350 degree; rotate them to your desired angles.
FIG. 1
Driver Screw
Metal
Gasket
Junction
Box Screw
C1
D1
4x12” Rods
B1
350°
1x6” Rod
350°
350°
Junction Box
Mounting Back Plate
A1
Wire Connector
Driver
Canopy
E1
Mounting Screw
Swivel
Rods
Fixture Faceplate
Fig. 2 Wiring
Fig. 3
Turn to down
modernforms.com
Phone (800) 526.2588 Fax (800) 526.2585
Fixture Wires
Black or Smooth
Fixture Wires
White or Ribbed
Fixture Wires
Bare wire (Ground)
House Wires
Black (Hot)
House Wires
White (Neutral)
House Wires
Green or Bare Copper (Ground)
Headquarters/Eastern Distribution Center
44 Harbor Park Drive Port Washington, NY 11050
Back Plate Dimensions
1 3/4"
Central Distribution Center
1 3/8"
Ø
10"
Western Distribution Center
1750 Archibald Avenue Ontario, CA 91760
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Loading...