Modern Forms MFDE1318 Installation & Assembly

Page 1
INSTALLATION INSTRUCTION
567 - LED Pendant
PD-56729
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture. CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1 B1 C1 D1 E1
Wire Connector
Qty: 3 pcs + 1 Extra
modernforms.com
Phone (800) 526.2588 Fax (800) 526.2585
Junction Box Screw Qty: 2 pcs + 1 Extra
#5-32x5/8
Nickel Plating
Headquarters/Eastern Distribution Center
44 Harbor Park Drive Port Washington, NY 11050
Plastic Anchor
Qty: 4 pcs + 1 Extra
Wood Screw
Qty: 4 pcs + 1 Extra
Ø4x22
Central Distribution Center
Mounting Screw
Qty: 1 Extra
5/32-32x1/2
Western Distribution Center
1750 Archibald Avenue Ontario, CA 91760
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 2
INSTALLATION INSTRUCTION
567 - LED Pendant
PD-56729
FIG. 1
Plastic Anchor
Wood Screw
Mounting Screw
Transformer
D1
C1
E1
Junction Box
A1
Wire Connector
Mounting Plate
B1
Junction Box Screw
Cable Gripper
Lamp Body
Back Plate Dimensions
Ø
7 5/8"
Ø
5 1/2"
1 3/4"
1 3/8"
Glass (RPL-GLA-56729-01)
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screws (E1) from the xture.
4. Drill holes in the ceiling aligned with the key holes located in the mounting back plate, insert the plastic anchors (C1).
5. Secure mounting back plate to the junction box using junction box screws (B1), fasten it to the wall using wood screw (D1). The side of the mounting plate marked “GND” must face out.
6. Adjust the xture wire length by pushing the cable gripper on the canopy and pulling the wire as desired.
CONNECTING THE WIRES (Fig. 2)
7. Connect the Transformer input wires with junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the mounting plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
8. Place the xture over the mounting back plate and secure it with mounting screws (E1).
modernforms.com
Phone (800) 526.2588 Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center
Fig. 2 Wiring
Fixture Wires
Black or Smooth
Fixture Wires
White or Ribbed
Fixture Wires
Bare wire (Ground)
Western Distribution Center
1750 Archibald Avenue Ontario, CA 91760
House Wires
Black (Hot)
House Wires
White (Neutral)
House Wires
Green or Bare Copper (Ground)
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 3
INSTALLATION INSTRUCTION
567 - LED Pendant
PD-56748
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture. CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1 B1 C1 D1 E1
Wire Connector
Qty: 3 pcs + 1 Extra
modernforms.com
Phone (800) 526.2588 Fax (800) 526.2585
Junction Box Screw Qty: 2 pcs + 1 Extra
#5-32x1
Nickel Plating
Headquarters/Eastern Distribution Center
44 Harbor Park Drive Port Washington, NY 11050
Plastic Anchor
Qty: 4 pcs + 1 Extra
Wood Screw
Qty: 4 pcs + 1 Extra
Ø4x35
Central Distribution Center
Mounting Screw
Qty: 1 Extra
5/32-32x13/16
Western Distribution Center
1750 Archibald Avenue Ontario, CA 91760
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Page 4
INSTALLATION INSTRUCTION
567 - LED Pendant
PD-56748
FIG. 1
Mounting Screw
Plastic Anchor
Wood Screw
Safety Cable
Transformer
C1
E1
D1
Junction Box
A1
Wire Connector
Mounting Plate
B1
Junction Box Screw
Cable Gripper
Back Plate Dimensions
1 3/4"
Ø
11 1/2"
Ø
7 7/8"
1 3/8"
Lamp Body
Glass
PREPARATION
(RPL-GLA-56748-01)
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove Remove the mounting screws (E1) from the xture.
4. Drill holes in the ceiling aligned with the key holes located in the mounting back plate, insert the plastic anchors (C1).
5. Secure mounting back plate to the junction box using junction box screws (B1), fasten it to the wall using wood screw (D1). The side of the mounting plate marked “GND” must face out.
6. Adjust the xture wire length by pushing the cable gripper on the canopy and pulling the wire as desired.
CONNECTING THE WIRES (Fig. 2)
7. Connect the Transformer input wires with junction box wires as shown in
Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet
Fig. 2 Wiring
Fixture Wires
Black or Smooth
House Wires
Black (Hot)
box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the mounting plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
8. Hook the safety cable to the mounting plate.
9. Place the xture over the mounting plate and secure it with mounting screws (E1).
Fixture Wires
White or Ribbed
Fixture Wires
Bare wire (Ground)
House Wires
White (Neutral)
House Wires
Green or Bare Copper (Ground)
modernforms.com
Phone (800) 526.2588 Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center
Western Distribution Center
1750 Archibald Avenue Ontario, CA 91760
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Loading...