
INSTALLATION INSTRUCTION
Kyoto - Exterior
WS-W22514
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
C1 E1 F1 J1
I1B1
Junction Box
Screw
Qty: 2pc
+ 1 extra
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2014 1
Wire Connector
Qty: 3pc
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Fixture
Qty: 5pc
+ 1 extra
Gasket
Qty: 5pc
+ 1 extra
Plastic
Anchor
Qty: 2pc
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Wood Screw
Qty: 2pc

INSTALLATION INSTRUCTION
Kyoto - Exterior
WS-W22514
Fig.1
Glass
E1 F1
Fixture Screw, Gasket
H1
Metal Frame
PREPARATION
Fixture Frame
Wood Screw
J1
G1
F1
E1
Anchor
I1
Junction Box Screw
B1
D1
Mounting Plate
Gasket
Fixture Screw
Junction Box
C1
Wire Connector
- Shut o the power at the circuit breaker and remove existing xture, including the mounting hardware.
Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES
1. Drill the holes in the proper position on the wall according to the keyholes located on the mounting plate (D1).
Insert the plastic anchors (I1) into the wall.
2. Secure the mounting plate (D1) to the junction box (A1) using the junction box screws (B1). Fasten mounting plate (D1) to the wall using the
wood screws (J1). The side of the mounting plate marked “GND” must face out.
3. Connect the xture wires to supply wires as shown in Fig. 1, Fig. 2, making sure that all wire connectors (C1) are secured. If your outlet box
has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the
mounting plate (D1) using the green screw provided. After wires are connected, tuck them carefully inside the junction box (A1).
MOUNTING THE FIXTURE (FIG. 1)
4. Place the xture frame (G1) over the mounting plate (D1) and secure with xture screws (E1) and gaskets (F1). Put the glass (K1) on the
xture frame (G1) from the top and put the metal frame (H1) on the glass (K1) secure it to the mounting plate (D1) with xture screw (E1)
and gasket (F1).
COMPLETING THE INSTALLATION
5. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of xture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig.3
Fig.2 Wiring
Fixture Wires
Black or
Smooth
House Wires
Black
(Hot)
Fig.3 Sealing
Junction Box
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2014 2
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Caulking
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585