Modern Forms MFDE1091 Installation & Assembly

Page 1
(Please direct wire with 120V AC)
Urban
WS-W1116, WS-W1122
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture. CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
Driver
Modern Forms
www.modernforms.com Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. SEPTEMBER, 2014
Technology Upgraded No Driver Required
A1 B1 C1 H1 C1
Wire Connector Qty: 3
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050
Junction Box Screw Qty: 2 + 1 Extra
Fixture Screw Qty: 1 Extra
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585
Mounting Screw Qty: 2
Anchor Qty: 2
Page 2
Urban
WS-W1116, WS-W1122
FIG.1
G1
Gasket
C1
Fixture Screw
H1
Mounting Screw
J1
Anchor
K1
Junction Box Screw
F1
Junction Box
C1
Fixture Screw
H1
Mounting Screw
Junction Box Screw
E1B1
Green Screw
J1
Anchor
Mounting backplate
K1
Junction Box Screw
A1D1
Wire Connector
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation
3. Remove mounting screws (C1)
4. Connect xture wires to junction box wires as shown in Fig. 2 making sure all wire connectors are secured. Fixture and junction box ground wires should be connected to mounting plate using green screw provided. After wires are connected, tuck them carefully inside the junction box.
5. Secure mounting backplate (D1) to the junction box (F1) using junction box screws (B1). The side of the mounting backplate marked “GND” must face out.
6. Drill holes in the wall aligned with the keyholes locations on the Fixture back plate insert anchors.
7. Place the xture’s backplate over the mounting backplate (D1) and secure with screws (G1).
8. Secure xture back plate with screws (H1) into anchors (J1)
9. Mount xture body to the xture back plate using screw (C1) and gaskets (G1)
COMPLETING THE INSTALLATION (Fig. 3)
10. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the outside of xture backplate where it meets the wall. Leave a space at bottom to allow moisture a means to escape.
Fig.2 Wiring
Fixture Wires
Black or Smooth
Fixture Wires
White or Ribbed
Fixture Wires
Bare wire (Ground)
Modern Forms
www.modernforms.com Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. SEPTEMBER, 2014
House Wires
Black (Hot)
House Wires
White (Neutral)
House Wires
Green or Bare Copper (Ground)
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050
Fig.3 Sealing
Junction Box
Caulking
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585
Loading...