3
indoor locations. Never locate heater
where it may fall into a bathtub or
other water container.
9. Do not run cord under carpeting. Do
not cover cord with throw rugs, runners or the like. Arrange cord away
from traffic area and where it will not
be tripped over.
10. To disconnect heater, turn controls to
the OFF before removing plug from
outlet.
11. Do not insert or allow foreign objects
to enter any ventilation or exhaust
opening as this may cause an electric
shock or fire or damage the heater.
12. To prevent possible fire, do not block
air inlets or outlets in any manner. Do
not use on soft surfaces, like a bed,
where openings may become
blocked.
13. Always use properly grounded fused
and polarized outlets.
14. A heater has hot and arcing or spark-
ing parts inside. Do not use it in areas
where gasoline, paint or flammable
liquids or vapors are used or stored.
15. Use this heater only as described in
this manual. Any other use not recommended by the manufacturer may
cause fire, electric shock or injury to
persons.
16. Avoid the use of an extension cord
because the extension cord may
overheat and cause a risk of fire.
However, if you have to use an extension cord, the cord should be No.
14 AWG minimum size and rated not
less than 1875 WATTS.
17. Always use ground fault protection
where required by electrical codes.
18. Always disconnect power before performing any cleaning, maintenance or
relocation of heater.
19. To prevent a possible fire, do not
burn wood or other materials in this
heater.
20. To prevent electric shock or fire, always use a certified electrician
should new circuits or outlets be required.
21. When transporting or storing heater,
keep in a dry place.
22. Control panel door gets hot during
heater operation. Open door by
pressing on right corner. A spring
magnet will disengage. Pull door
down to open.
23. SAVE THESE INSTRUCTIONS
Safety
Listing Approvals
This heater has been tested in
accordance with the CSA Standards for fixed and locationdedicated electric room heaters
in the United States. This fireplace is UL or CSA safety certified.
AL-100 CLX AL-60CLX AL-40 CLX
Volts AC 120V/60Hz AC 120V/60Hz AC 120V/60Hz
Amps 15 Amp 15 Amp 15 Amp
Watts 1570 W 1530 W 1520 W
Heater
AC 120V/60Hz
1500W
AC 120V/60Hz
1500W
AC 120V/60Hz
1500W
No Heater
Lamps
LED DC12V 5W*7
LED DC3V 3W*8
LED DC12V 5W*3
LED DC3V 3W*4 LED DC12V 5W*3
Rotor motor
AC 120V/60Hz 4W
CCW 15/18 r/min
AC 120V/60Hz 4W
CCW 15/18 r/min
AC 120V/60Hz 4W
CCW 15/18 r/min
Shipping Size 2600*230*800mm 1590*230*800mm 1080*230*800mm
Shipping Weight