User Manual of MOBILUS C-MR external receiver
www.mobilus.pl
1. IMPORTANT INFORMATIONS
• When unpacking the unit, make sure that there is no damage in the transport. If so, you
should immediately inform the supplier.
• Read the operating manual carefully before use
• MOBILUS C-MR module should be powered by 230 V ~, 50 Hz. Its installation should only
be carried out by persons with electrical qualifications according to the enclosed electrical
diagram in accordance with all applicable regulations.
• MOBILUS C-MR module is designed to work with all COSMO / COSMO | 2WAY series remote controls.
• The range of the radio control is limited by regulations for maximum power of the remote
control and the conditions of the installation of the equipment. When designing the location
of the remote control, consider limiting the range to about 20m by 2 walls.
• Declaration of Conformity:
We declare under our sole responsibility that the MOBILUS C-MR complies with the
following European Directives:
1. 2014/53 / EU RED Radio Directive;
2. 2014/30 / EU Electromagnetic Compatibility Directive.
3. 73/23/EWG Low Voltage Directive.
2. ENTRY INTO THE MODULE PROGRAMMING MODE
Press and hold a programming button on module MOBILUS C-MR
above 5 sec until the connected actuator executes one sequence
of noticeable and audible micro movements down / up confirming
the entrence of the receiver in the PROGRAMMING MODE.
WARNING! If within 20 seconds no programming will be performed, the MOBILUS C-MR radio module automatically exits
from the programming mode. Connected actuator executes
one sequence of noticeable and audible micro movements
down / up, blinks are stopped.
1 s.
BEEP! BEEP!
PILOT 2
1 s.
b
3. LOADING THE MASTER-A * CODE TO THE RECEIVER MEMORY
1. Enter the MOBILUS C-MR PROGRAMMING MODE.
2. Press and hold the STOP and UP buttons
simultaneously on the remote control until the connected
actuator executes one sequence of noticeable and audible
micro movements down / up.
3. The MASTER-a code has been loaded into memory and
the module goes to the WORK MODE. Now, with the
MASTER remote control, you can operate the units or enter
the PROGRAM MODE to load more remote controls.
BEEP! BEEP!
PILOT 2
1 s.
b
WARNING In the case of a multi-channel remote control
select only one channel to be MASTER.
NOTE For the convenience of programming, it is recom-
mended that each COSMO | C-MR module had its own
separate MASTER (remote control (separate channel for
multi-channel remotes). Avoid situations where several
COSMO | C-MR modules remote controls will have
common MASTER (shared channel).
1 2 3 4 5 1 2 3 4 5
*MASTER - remote control or channel (in the case of a multi-channel remotes) loaded first into
the memory of the MOBILUS C-MR module. Allows you to program further remote controls.
3
4. PROGRAMMING OF THE SECOND AND EVERY OTHER REMOTE CONTROL
1. On the MASTER remote control, simultaneously press and hold the STOP and UP until the
connected actuator executes one sequence of noticeable and audible micro movements down / up
confirming the entrence of the receiver in the PROGRAMMING MODE - Fig. 4a. Additionally in this
mode every 1 sec. the diode is blinking.
2. On the second remote control (for the multi-channel remote control, select the channel
you want to program), press and hold both STOP and UP buttons simultaneously, until the
connected actuator performs one sequence of noticeable and audible micro movements
down / up. The remote (channel) was loaded into the receiver’s memory - Fig. 4b.
Fig. 4
Repeat step 2 to load the next remote control. If, however, no programming operation is started
within 20 seconds, the module automatically returns to operating mode. Return to operating
mode can also be performed manually using MASTER. In such a situation, press and hold the
STOP and UP MASTER buttons. In both cases, the return to operating mode will be confirmed
by a single sequence of micro movements down / up of the connected actuator.
4
5. CHANGING THE DIRECTION OF THE ACTUATOR
1. If you press the UP button on the remote control and the armor goes down, change the
direction of rotation of the drive. At the same time, press and hold:
a ) on the remote control COSMO | HM, | HB, | G3+, | WT9, | WT buttons STOP and DOWN - Fig. 5b;
b ) on the remote control COSMO | HT, | H24,| H1, | H5, | G, | W1, | W7 buttons DOWN and UP - Fig. 5c;
c ) on the remote control COSMO | HCT UP and F3 buttons - Fig. 5d;
until the drive executes one sequence of micro down / up moves.
2. Check the UP / DOWN buttons - Fig. 5e.
Fig. 5
a e
c
d
6. C-MR MODULE RESET - FACTORY SETTINGS
WARNING!!! RESTORATION OF FACTORY SETTINGS erases all programmed remotes from the
MOBILUS C-MR module.
1. Enter the PROGRAMMING MODE for the MOBILUS C-MR module - Fig. 6a.
2. In the PROGRAMMING MODE, press and hold the programming key above 5 seconds - Fig.
6b. All previously loaded remote modules have been removed from the memory module
which confirms one sequence of noticeable and audible micro moves down / up of the
connected actuator.