MOBASE ELECTRONICS SEKS AM08TX, SEKS AM08RX User Manual

Title : NO. : SCE-0807
Information Document
Information Document
Date : 2008.07.15
2. PRODUCT SPECIFICATION
2.1 Scope of Remote Keyless Entry in BCM system.
21.1 Key part : TRANSMITTER is inside of the remote key, and it sends the rolling code to the RECEIVER by radio frequency.
2.1.2 RECEIVER : It receives the rolling code and decodes that, thereafter RECEIVER drives the actuator.
2.2.1 TRANSMITTER
Rated supply voltage DC 3V
Operating voltage range DC 2.5 ~ 3.2V
Operating temperature range
Storage temperature range
Modulation FSK Frequency 315.00MHz
Electric field strength 75.623dBuV/m (315.00MHz)
Battery life 2 Year(10Times/Day)(Lithium 3V 1EA)
2.2.2 RECEIVER
Operating Temperature
Max Humidity 95%
Standby Current
ITEM
Code Rolling Code(Hopping Algorithm)
Item
SPECIFICATION
-20 ~+60
-30 ~ 80
Specification
DC 12V Rated Supply Voltage
DC 9 ~ 16V Operating Voltage
- 30 ~ + 80
Below than 6mA
(in alarm setting condition)
Title : NO. : SCE-0807
Information Document
Information Document
Date : 2008.07.15
2.3 Operating summary
TRANSMITTER's button is pushed. TRANSMITTER sends the code by radio frequency. RECEIVER gets the code and decodes it. RECEIVER judges the code whether it is right code or not. RECEIVER checks door lock or unlock or PANIC state.
RECEIVER drives the actuator. RECEIVER drives the horn
2.3.1 LOCK & UNLOCK & PANIC
If LOCK or UNLOCK button is pushed for less than 1 sec, then TRANSMITTER sends the LOCK or UNLOCK DATA.
If PANIC button is pushed for more than 1 sec, then TRANSMITTER sends the PANIC.
2.4 Caution
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Page 5 of 11