MM MWS Operation Manual

Operation Manual
MWS SERIES
Note: Under the scale there is a breathable knob. Its default setting is for weighing. If you want to clean the scale, tighten the knob. After cleaning, release the knob for weighing
When used for weighing, release screw to get normal pressure
When it needs to be cleaned, tighten screw to seal it
!
Contents
1
Introduction
1
2
Key functions
1
3
Operation
3.1
Zero
1 3.2
Tare
1
3.3
Changing units
1
4
Parameter and Calibration
4.1
Entering setting mode
2 4.2
Calibration
2 4.3
Setting resolution
2 4.4
Changing capacity
2
4.5
Checking internal counts
2
4.6
Automatic sleep mode
2
1 INTRODUCTION
The MWS series of waterproof scales consist of a stainless steel housing and a stainless steel platform. It has an exterior design of patented IP67 waterproof technology.
The MWS series use of very low amounts of power.
The keypads are light touch switches and the displays are large easy to read liquid crystal type
displays (LCD). Units include automatic zero tracking, tare and unit shift functions.
2. KEY FUNCTIONS
ZERO
Set the zero point for all subsequent weighing. The display shows zero.
TARE
Tares the scale. Stores the current weight in memory as a tare value, subtracts the tare value from the weight and shows the results. This is the net weight
UNIT
Press TARE key and ZERO key to together in the weighing mode
ON/ OFF
Turns on/ off the power
3. OPERATION
3.1 Zeroing the display
You can press the ZERO key at any time to set the zero point from which all other weighing and counting is measured. This will usually only be necessary when the pan is empty. When the zero point is obtained the zero indicator will appear.
The scale has an automatic re-zeroing function to account for minor drifting or accumulation of material on the platform. However you may need to press the ZERO key to re-zero the scale if small amounts of weight are shown when the platform is empty.
3.2 Tare
Zero the scale by pressing the ZERO key if necessary. The zero indicator will be on. Place a container on the platform, a value for its weight will be displayed. Press the TARE key to tare the scale. The weight that was displayed will be stored as the
tare value. The value is subtracted from the display, leaving zero on the display. The "TARE" indicator will be on. As product is added only the weight of the product will be shown.
When the container is removed a negative value will be shown. If the scale was tared just before removing the container this value is the gross weight of the container plus all product that was removed.
The zero indicator will also be on as the platform will revert to the operating condition of when the ZERO key was last pressed.
3.3 Changing unit
Press the TARE and ZERO key together to change the weighing unit in the weight mode. The relevant weighing unit mark turn on
4. PARAMETERS AND CALIBRATION
4.1 Entering setting mode To set the parameters, turn on the weighing scales and hold the TARE key during self-
checking, until the display show “F1 CAL”.
4.2 Calibration
After entering settings mode, and setting the parameter. The display will show "F1 CAL". Press the ZERO key, display shows “UNLD”, empty the platter, after the “STABLE” indicator turns on, press the ZERO key again. The display will show the calibrate weight. Press the TARE key to select the appropriate calibrate weight. After selection, put the calibrate weight on. When the STABLE indicator turns on, press the ZERO key to confirm. The display will shows “pass”. The calibration will be complete.
4.3 Setting resolution
After entering setting mode, the display will show “F1 CAL”. Press the TARE key, until the display shows “F2 RES”, press the ZERO key to enter, and press the TARE key to select
the resolution.
4.4 Changing capacity
After entering the settings mode, the display will show “F1 CAL”. Press the TARE key until the display shows “F3 CAP”. Press the ZERO key to enter, then the TARE key to select capacity. Press ZERO key to confirm.
4.5 Checking internal counts
After entering the settings mode, the display will show “F1 CAL”. Press the TARE key until the display shows “F4 INP”. Press the ZERO key to enter, display will show internal counts. Press the TARE key to return settings.
4.6 Automatic sleep-mode
In weighing mode, if the scale is unmoved, and there is no change of weight, the scale will enter sleep mode after a minute. Increasing the weight by 4d will re-wake the scale for use.