MK Plastics AXPR IO-M User Manual

Bulletin 78-January-03-06
AXPR
Wall Mounted Axial Panel Fans
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
This publication contains the installation, operation and maintenance instructions for the AXPR wall mounted axial panel fans.
M.K. Plastics catalogs and reference material on the above system, provides additional information describin g the equipment, performance, available accessories, and specifications.
For Information on special application requirements, contact M.K. Plastic’s corporate office at (514) 871-9999.
Fig. 1 – AXPR Propeller Fan
Receiving and Inspection
Carefully inspect the venturi/blower and accessories for any damage and shortage immediately upon receipt of the fan.
Turn the propeller by hand to ensure it turns freely and does not bind.
If shutters are provided, check for free operation of all moving parts.
Record on the Delivery Receipt any visible sign of damage.
1
WARNING The AXPR has rotating parts. Safety precautions should be exercised at all times during installation, operation, and maintenance. ALWAYS
disconnect power prior to working on fan.
Handling and Storage
Fans should be lifted by the panel mounting flanges. Never by the propeller, motor, motor bracket, fan inlet, shutter frame, or any other part not designed for lifting.
If the fan is stored for any length of time prior to installation, the fan and accessories should be stored in a dry, clean location. If outdoor storage is necessary, protection should be provided. The fan should be covered to prevent the accumulation of dirt and moisture. Cover motors with waterproof material.
Check shutters for free operation and lubricate moving parts prior to storage. Inspect the stored unit periodically.
Rotate the propeller by hand every two weeks.
Personal Safety Disconnect switches are recommended. Place the disconnect switch near the fan in order that the pow er can be swiftly cut off in case of an emergency, and in order that maintenance personnel are provided complete control of the power source.
Installation
Cut out wall opening of sufficient size so that, when framed in, the finished opening will accept the fan and wall box assembly, (refer to MK Plastics submittal for specific outside dimensions of the wall box). It is preferable to frame in the opening with 2 x 6 material, or other similar suitable material or metal channels adequate to support the fan as shown in Figure 2. Slide the fan and wall box assembly into the framed opening in the wall. Attach the fan by inserting a suitable fastener through each of the pre-punched mounting holes in the fan panel mounting fla nge. Care should be taken not to bend or distort the fan panel or other components during installation. A distance of at least one and one­half times the diameter of the fan should be allowed between the fan inlet or discharge opening and any adjacent wall or large obstruction.
If a weather cowl is supplied on a supply fan, position the cowl over the opening on the exterior side of the wall, and attach by inserting suitable fastener through each pre-punched mounting hole of the cowl mounti ng flange.
Fig. 2 – Wall Installation