Mk electric LOGIC PLUS TELEPHONE AND TV SOCKETS DATASHEET

Page 1
TECHNICAL DATA SHEET
Logic Plus
Telephone and TV Sockets
1:3
Logic Plus™ Telephone and TV Sockets
PRODUCT RANGE
Telephone Sockets
Telephone socket/master K422 WHI
Telephone socket/secondary K427 WHI
Telephone socket/RJ11 (Western Telecom) K4817 WHI
TV Sockets
TV/FM Co-axial socket (single) K3520 WHI
Isolated TV/FM Co-axial socket (single) K3521 WHI
Isolated TV/FM Diplexer K3522 WHI
TV/FM Co-axial socket (twin) K3523 WHI
‘F’ type Satellite socket K3525 WHI
Standards and approvals
Logic Plus Telephone and TV sockets comply with the following:
BS 6312: 2.2, BS 5733: 1995 (where applicable) and OFTEL Approval NS/G/23/L/100005.
K4817: BS 5733: 1979 (where applicable) and FCC68.
TV sockets K3520, K3521 and K3523
BS 3041: Part 2: 1977/IEC 169-2: 1977, BS5733: 1995 (where applicable) and IEC65, Cls 10.1, 10.3.
TV sockets K3525
BS 5733: 1995 (where applicable).
Description
A part of the very wide range of products in the distinctive Logic Plus style to meet the latest technical requirements and the standards applicable to modern technology in the installation of telephone and television equipment. The master and secondary tele­phone sockets K422 and K427 comply with relevant OFTEL approvals for direct and indirect connections between a termination point of a public telecommunications system and any piece of approved telecommuni­cations apparatus. For applications requiring twin or dual telephone outlets, refer to ‘Modular Data and Telephone Sockets’.
Features
I Single screw termination on TV outlets
I Protected, fully enclosed PCBs
I Meet all relevant BS requirements
I Attractive new easy-clean Logic Plus
styling
I Quick, simple and reliable terminal
connection
I Can be specified for all applications
Logic Plus Telephone and TV sockets will fit in plaster depth boxes (except for RJ11).
For the modular products and frontplates in the same Logic Plus range, see ‘Modular Data and Telephone Sockets’, page 2.21.
The F-type Satellite Socket may be used for connection of CATV, MATV and satellite TV installations.
Digital TV outlets are available. See separate data sheets or refer to MK catalogue.
I IDC connectors on telephone outlets
I Part of a complete range of products
for telephone, television and data processing requirements
I Angled connector on TV outlets
I Sockets fit in plaster depth boxes
(except K4817)
©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric.co.uk www.mkelectric.co.uk Edition 06-02
Page 2
TECHNICAL DATA SHEET
85
14
25Typically
85
60.3
15
Logic Plus
Telephone and TV Sockets
2:3
Dimensions (mm)
85
25Typically
14
85
25Typically
14
TECHNICAL SPECIFICATION
Electrical
Telephone sockets, cable specification: CW1311, CW1293, CW1308, CW1316 No. of cables per termination:
0.4mm to 0.7mm, 1 or 2
0.7mm to 0.9mm, 1 only
Overall installation:
0.7mm to 1.4mm
Re-usability:
0.4mm to 0.65mm diameter wire, >99 reterminations
0.7mm to 0.9mm diameter wire, >9 reterminations (should not be reterminated with smaller diameter wire)
TV sockets, cable specification: Any standard low-loss, air spaced TV co-axial cable: Outside 4-8mm diameter, inner conductor 0.5-2mm diameter URM 202, URM 203, URM 76, URM 90, RG 59
Insertion loss: Graphs showing insertion loss available on request
‘F’ Type satellite socket (K3525), cable specification: Co-axial cable: inner core diameter – 0.5-1.2mm
RJ11 (K4817), Cable specification: Capable of taking 0.08 to 0.65mm stranded cable
Physical
Ambient air: –20°C to +460°C
IP rating: IP4X
Max. installation altitude: 2000 metres
2
solid or
85
60.3
K3520/3521
85
15
9
85
60.3
K3522/3523
85
60.3
K3525
Sectional drawings show the furthest projections from the back of the frontplate (wall surface), including a typical coxial connector in the case of TV sockets. All units will fit in 16mm plaster depth boxes except for K4817 (Western Telecom socket).
Box types
List No. Flush Surface
K422 3995 ZIC (16mm) K2160 WHI
K427 3995 ZIC (16mm) K2160 WHI
K4817 861 ZIC (25mm) K2140 WHI
K3520 3995 ZIC
(16mm) K2160 WHI
20
K3520/3521
List No. Flush Surface
K3521 3995 ZIC (16mm) K2160 WHI
K3522 3995 ZIC (16mm) K2160 WHI
K3523 3995 ZIC (16mm) K2160 WHI
K3525 3995 ZIC
15
(16mm) K2160 WHI
©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric.co.uk www.mkelectric.co.uk Edition 06-02
Page 3
TECHNICAL DATA SHEET
Logic Plus
Telephone and TV Sockets
3:3
Installation (Telephone sockets)
Product performance, systems compatibility
Master Sockets: for use as the first socket outlet on a direct exchange or PABX line. They contain surge protectors (for line protection against electrical surges) and capacitors.
Secondary Sockets: For use as extension sockets when connected on the same master line as a Master Socket.
Wiring regulation restrictions
Domestic installations: Any number of MK sockets may be installed thereafter, with a maximum of 5 telephones normally being allowed on one exchange line.
Industrial and commercial installations: MK telephone sockets are suitable in all situations after the PBX/PABX has been installed by a recognised installer. For key systems and other ‘special’ systems, the manufacturer’s instruc­tions should be referred to.
Installation tools required
MK IDC insertion tool List No. 400 or 22630 (not supplied with product).
Cable Management
Logic Plus Telephone and TV sockets can be mounted in a variety of MK trunking systems.
See MK catalogue for further details.
Single/dual
(single circuit)
Sockets
61
1 2 3
Colour Code
Pin Colour Pin Colour
1 GREEN White 4 WHITE Orange 2BLUE White 5 WHITE Blue 3 ORANGE White 6 WHITE Green
view from rear
6 5 4
Installation (TV sockets)
Product performance, systems compatibility
Non-isolated products are intended for direct connection to a single or two separate TV/FM aerial downleads: These units must NOT be used in multi-outlet aerial distribution systems.
Isolated products are intended for such use and provide the necessary safety isolation, rated at 2000V AC, against a fault occurring within any mains powered product used elsewhere in the system (it is intended that each unit be fed from a separate ‘T’ box con­taining electrical padding and attenuation).
Method of installation of TV and FM aerial connection by using MK co-axial socket outlet and only one down lead.
1. Connect co-axial plugs to the ends of TV
aerial and FM aerial cables in loft.
2. Plug into frontplate of co-axial socket
outlet situated in loft.
3. Run a length of co-axial cable from back of
this outlet to the back of the outlet situated in the living room, then plug TV or FM radio into frontplate as normal. This is a very simple neat solution which works well technically.
Twin
(two circuit)
Sockets
6 161
1
1 2 3
6
2
5
3
4
circuit
1
Note: Main wiring colour is shown in capitals.
Existing equipment may have a different colour code system which should be retained on any new installation.
6 5 4
circuit
2
FM
Outlet in loft
FM & TV aerial
single coaxial
leads
down lead
Radio TV
Outlet in living room
Use of cable clamp
Sharp bends in the cable must be avoided during installation. The single TV/FM socket is fitted with a cable clamp that can be fixed on either side of the termination position to facilitate this.
Safety information
None of the above products should be installed into the same fixing or mounting boxes as mains rated cable.
TV
©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric.co.uk www.mkelectric.co.uk Edition 06-02
Loading...