MK Electric K5215SHWHI Installation Instructions

B. RECOMMENDED MK BOX LIST
NUMBERS
32
4 5 6
7 8 9
32A Double Pole Switches
45A Double Pole Switches
Cooker Control Units
A Safety Instructions 2
B Recommended MK 4
Box List Numbers
C Installation 5
D Disposal Instructions 13
E Guarantee 14
Please leave this leaflet with the end user for future reference
41136PL Ed.4
1. To prevent the risk of electrocution it is essential to turn off the mains electricity supply before commencing work.
2. Do not work on this product live.
3. To ensure a safe installation;
- this product should be installed by a
competent person (e.g. a qualified electrician) in accordance with these instructions and the appropriate clauses of the current edition of the IEE Wiring Regulations (BS 7671).
- it is essential that all connections are made as
instructed, that cables are not stressed and that terminal screws are fully tightened.
- all sockets must be earthed and the earth
leads adequately sleeved.
A. SAFETY INSTRUCTIONS
C. INSTALLATION (Cont.)
4. Ensure that all electrical connections are correct and fully secured and that the product is screwed securely to its mounting box before turning the mains electricity supply on.
5. To prevent fire hazard do not exceed the
maximum rated current of the switch or socket.
Refer to the product packaging for the type of switch/unit being installed.
All switches/units should be mounted on boxes according to the size of conductor cable used (see section B).
Switch/ Unit Cable
Flush Mounting Surface Mounting
List No. Size 1 Gang 2 Gang 1 Gang 2 Gang
K5105 6mm2866ZIC K2140
10mm2877ZIC K2031
K5205, 6mm2– 886ZIC K2172 K5215
10mm
2
878ZIC K2172
K5012 6mm2K5120 K5120
10mm2K5120 K5120
K5060, 6mm2– 886ZIC K5061
10mm
2
878ZIC
K5011 K5120 K5120
You must connect the wires to the correct terminals.
The red wires must be connected to the appropriate terminals marked L.
The black wires must be connected to the appropriate terminals marked N.
The bare wires (sleeved green/yellow) must be connected to the appropriate earth terminal marked .
Where a mounting box earth terminal is provided, connect a length of green/yellow sleeved wire between this terminal and the earth terminal on the unit.
When neons are fitted, one lead should be connected to ‘L’ and the other to ‘N’. Neon leads are not colour coded as it does not matter which way round they are fitted.
4. Insert the bared ends of the wires into their appropriate terminals and securely tighten both terminal screws (see Fig.1) ensuring all conductors are clamped.
5. Carefully push wired unit back into the mounting box, ensuring cables are not trapped or pinched.
6. Locate and tighten frontplate fixing screws. Do not overtighten screws, to do so may damage frontplate or box threads.
The completed installation should be tested in accordance with the current IEE Wiring Regulations by a qualified electrician.
If in any doubt, contact MK Technical Sales Service Department. Telephone 01268 563720.
C. INSTALLATION
IMPORTANT
Refer to safety instructions before starting work (Section A).
A. Products supplied with a mounting box
i. Separate the lid accessory from the box by
removing the two fixing screws.
ii. Remove appropriate knock-outs from the
box for incoming and outgoing cables as required. It is good practice on metal boxes to fit a grommet where conduit is not used.
iii. Fix box securely to the wall.
B. Products without mounting box
i. Remove frontplate fixing screws from their
location on the back of the frontplate, or from the plastic strip attachment.
ii. Ensure the mounting box is firmly secured to
the wall.
Electrical Connections
1. Strip back LOAD and SUPPLY outer cable sheaths and trim wires to the appropriate length to allow cable ends to reach the terminals.
2. Carefully strip red and black insulation by 20mm (0.8 inches).
3. Slide a length of green/yellow insulating sleeve on to a bare earth wire.
IMPORTANT
SUPPLY cables are those coming from the distribution board. LOAD cables are those going to the appliance.
Fig.1 32 Amp DP Switch
See Note 1
See Note 2
Note 1: If you require surface mounted K5060 or K5061,
use K5040 or K5041 respectively.
Note 2: If you require surface mounted K5011, use K5001.
SUPPLY
LOAD
LN
LN
E
32A DP
250V AC ONLY
BS3676
Supply Cable
Green/Yellow Sleeve
Neon (when fitted)
Green/Yellow Sleeve
Load Cable
Red Black
Red Black
Neon Leads should be fitted with Cables
14 15
16 17 18
13
11 12
The Company undertakes to replace or repair at its discretion this product should it become defective within a period of 20 years after delivery solely as a result of faulty materials and/or workmanship. Understandably if the product has not been installed or maintained in accordance with the Companys instructions, has not been used appropriately or if any attempt has been made to rectify, dismantle or alter the product in any way the guarantee will be invalidated.
This Guarantee states the Companys entire liability. It does not extend to cover consequential loss or damage or installation costs arising from the defective product. This Guarantee does not restrict or infringe the normal statutory or other rights of the consumer.
E. GUARANTEE
MK Electric Limited wishes to make it clear that it owns all the original designs of the products which it manufactures (whether or not listed in this leaet) and that it will take all necessary legal action in any part of the world against any party found to be manufacturing, distributing, selling or otherwise dealing with any article which infringes the companys intellectual property in its own products, or any other right of the company therein.
The 32A and 45A Switches conform to BS 3676 Pt.1: 1989, the Cooker Control Units conform to BS 4177: 1992. All are manufactured in accordance with BS EN ISO 9002 and comply with the EMC and LV directives 89/336/EEC and 73/23/EEC respectively.
COMPLIANCE WITH E.U. DIRECTIVES
®
It’s simply safer to say MK
MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA Telephone 01268 563000 Facsimile 01268 563563 (UK Sales)
Facsimile 01268 563360 (International)
email: more@mkelectric.co.uk
Web site: www.mkelectric.co.uk
All marks in this document identied with a ® or symbol
adjacent to the mark are Trade Marks of MK Electric Limited
At the end of its useful life, the products and packaging can be safely disposed of via standard refuse facilities.
D. DISPOSAL INSTRUCTIONS
PLEASE LEAVE THIS LEAFLET WITH THE END USER FOR FUTURE REFERENCE.
INSTALLER/ELECTRICIAN
Name ......................................................................
Address ...................................................................
..........................................................................
Telephone Number ................................................
LOCAL ELECTRICITY BOARD
Contact ...................................................................
Telephone Number ................................................
LOCAL MK STOCKIST
Name ......................................................................
Telephone Number ................................................
USEFUL INFORMATION
C. INSTALLATION (Cont.)
Fig. 2 45 Amp DP Switch Fig.3 Cooker Control Units
If in any doubt about the correct installation of these products, contact MK Technical Sales Service Department. Telephone 01268 563720.
Note
Locator - means the neon is energised all the time the supply cables are live.
Indicator - means the neon is only energised when the switch is on
Supply Cable
NEON
45A 250V a.c. ~ D.P.
BS3676
NEON
Green/Yellow Sleeved
L1
L2
Green/ Yellow Sleeved
Neon Leads (when Neon used as a Locator)
Neon Leads (when Neon used as an Indicator)
Neon (when fitted)
Black Red
Black Red
N1
N2
Load Cable
Cooker Neon (when fitted)
Green/ Yellow Sleeved
Socket Neon Connections (when fitted)
E
Green/ Yellow Sleeved
Supply Cable (Mains)
Red Black
L
MAINS
45A–250V
COOKER
L
Red Black
Load Cable (Cooker)
~
BS4177
Socket Neon (when fitted)
N
N
Cooker Neon Connections (when fitted)