MK Electric K3638GRA, K1000BLK, K1000WHI, K1000CLR Installation Instructions

Technical Hotline +44 (0)1268 563720
Wiring Devices Technical
Installation general information
Socket outlets, switches and other MK wiring accessories can be wall or bench mounted. Do not use a trailing lead for sockets and connection units or mount any devices where they may be subject to excessive moisture or dampness.
Cable management
Socket outlets, switches and other MK wiring accessories can be mounted in a variety of MK trunking systems.
13A Socket Outlets
Standards and approvals
13A socket outlets comply with BS 1363 Part 2:1995.
Replacement fuses to the 3 gang switchsocket outlets (Logic Plus only) comply with BS1362:1973.
TECHNICAL SPECIFICATION
ELECTRICAL
VOLTAGE RATING
250V a.c.
CURRENT RATING
13A (3 Gang Switchsocket 13A total)
TERMINAL CAPACITY
Live, neutral & earth 3 x 2.5mm² 3 x 4mm² 2 x 6mm² (standard) (Dual earth terminals on list Nos. K781, K2657, K2737, K2746, K2757, all standard Edge and Aspect sockets, K733, K2958, K2458, K2947, K2947D6, K850, K2977, K2477, K3045, K3077, K2945, K2945D6 and K5357)
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
Description
A range of socket outlets designed for ease of installation and having all the advantageous design features of the MK range of wiring devices. The 2 gang sockets with outboard rockers (available in Logic Plus and Albany Plus) are of particular value for use by the inrm and partially sighted whilst the same feature in Metalclad Plus is ideal for use with gloved hands.
Non-standard clean earth sockets are for use on installations where restricted access is required and will only accept a 647WHI 13A non-standard plug with T-shaped earth pin. The sockets have two independent earth terminals so that they can also be used for ‘clean earth’ installations. The K2746CE and K2947CE also have two independent earth terminals for ‘clean earth’ installations.
A variety of sockets (see Technical Specication) are tted with two earth terminals on a common busbar to provide a double earth facility for use when installations require a high integrity protective connection as specied within the latest edition of BS7671 which should be referred to for guidance.
The products can be quickly installed as replacement for existing 13A sockets or in a new installation.
Fuse carriers
(Logic Plus 3 gang switchsocket only)
The fuse carrier is opened by a fast-acting, screwdriver-operated, worm-drive screw for ease of replacement.
WIRING DEVICES
For a full range of corresponding products,
see pages 32-188 in the product selector.
441
Wiring Devices Technical
WIRING DEVICES
13A Socket Outlets
Installation
1 gang switchsocket – view from rear
Top-facing, angled, backed-out terminals make wiring easier and quicker.
FEATURES
l
Moulded ‘on’ indicator flash on plastic
switches will not rub off – totally safe
l
Matching Metal rocker Switches
(Edge™ and Aspect only)
l
Optional neon indicators in the switch
rockers with 175° visibility in the horizontal and vertical planes
l
3 pin operated safety shutter
l
Printed terminal markings on grey rear
mouldings for clearer identification
l
Top access, angled terminals make
wiring easier and quicker
l
3mm minimum switch contact gap
l
Double pole switching
l
Choice of inboard or outboard
positioned rockers
mkelectric.co.uk
l
Additional electrical safety from DP
Switch, neutral ‘make first’, ‘break last’ feature
l
Switch contacts with silver contacts
on both surfaces for good continuity
l
Only one size of screwdriver required
for installation
l
Selection of products incorporating
dual earth terminals for high integrity earthing
l
Backed out and captive terminal
screws
l
‘Clean earth’ sockets available
l
Non-standard ‘clean earth’ sockets
available
442
Technical Hotline +44 (0)1268 563720
Wiring Devices Technical
– Logic Plus™
2 Gang Switchsocket Outlet with Integrated Dual USB Charging Capability
Standards and approvals
Logic Plus™ 13A socket outlets and 2A USB charging outlets comply with BS 5733 and IEC 61558-2-16.
EMC Compatibility: IEC 61000-6-1 IEC 61000-6-3
Products are CE marked and meet the requirements of the Low Voltage, EMC, RoHS and WEEE directives.
WIRING DEVICES
TECHNICAL SPECIFICATION
13A SOCKET OUTLETS
ELECTRICAL
VOLTAGE RATING
220-240V
CURRENT RATING
13A Combined total 2A drawn from USB outlets
STANDBY POWER
150mW
TERMINAL CAPACITY
Live, neutral & earth 3 x 2.5mm 3 x 4mm 2 x 6mm2 (stranded)
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
2
2
Installation
Logic Plus™ socket outlets can be wall or bench mounted.
Do not mount or use as a trailing socket or where they may be subject to excessive moisture or damp.
Description
A range of socket outlets designed for ease of installation and having all the advantageous design features of the Logic Plus™ range. Dual USB charging outlets offer end users easy access to power for charging a variety of devices such as smart phones, tablets and cameras.
FEATURES
l
Moulded ‘on’ indicator flash on
switches will not rub off – totally safe
l
3 pin operated safety shutter on 13A
socket outlets
l
USB 2.0 and 3.0 compatible
l
Can charge a device at up to a full 2A
l
If only one device is connected to a
USB outlet the total output current of 2A is available from either outlet
l
If two devices are connected to USB
outlets the the total rated current of 2A is divided between the two outlets
l
Differing manufacturers devices can
be charged simultaneously via the two USB outlets
l
If the total charging current exceeds
the rated level of 2A then the device will enter a current limiting safety mode
l
Electronically protected against an
overload or short circuit on either USB outlet
l
USB outlets are designed to provide
optimum charging compatibility across a wide range of devices
l
Printed terminal markings on grey rear
mouldings for clearer identification
l
Top access, angled terminals make
wiring easier and quicker
l
3mm minimum switch contact gap
l
Double pole switching
l
Additional electrical safety from
neutral ‘make first’, ‘break last’ feature
l
Switch contacts with silver contacts
on both surfaces for good continuity
l
Backed out and captive terminal
screws
l
Dual earthed
Dimensions (mm)
Cable management
Logic Plus™ socket outlets can be mounted in a variety of MK trunking systems.
BOX TYPES WITHOUT PATRESS
GANG FLUSH
DEPTH 35MM DEPTH 40MM DEPTH 41MM
2 GANG
886 ZIC K2172 WHI
SURFACE
INSULATED
SURFACE
METAL
K2212 ALM K2214 ALM
146
40
86
28120.6
443
Wiring Devices Technical – Aspect
WIRING DEVICES
2 Gang Switchsocket Outlet with Integrated Dual USB Charging Capability
Standards and approvals
Aspect 13A socket outlets and 2A USB charging outlets comply with BS 5733 and IEC 61558-2-16.
EMC Compatibility: IEC 61000-6-1 IEC 61000-6-3
Products are CE marked and meet the requirements of the Low Voltage, EMC, RoHS and WEEE directives.
mkelectric.co.uk
TECHNICAL SPECIFICATION
13A SOCKET OUTLETS
ELECTRICAL
VOLTAGE RATING
220-240V
CURRENT RATING
13A Combined total 2A drawn from USB outlets
STANDBY POWER
150mW
TERMINAL CAPACITY
Live, neutral & earth 3 x 2.5mm 3 x 4mm 2 x 6mm2 (stranded)
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
2
2
Installation
Aspect socket outlets can be wall or bench mounted.
Do not mount or use as a trailing socket or where they may be subject to excessive moisture or damp.
Description
A range of socket outlets designed for ease of installation and having all the advantageous design features of the Aspect range. Dual USB charging outlets offer end users easy access to power for charging a variety of devices such as smart phones, tablets and cameras.
FEATURES
l
Slim screwless frontplate design
l
Matching metal rocker switches
l
3 pin operated safety shutter on 13A
socket outlets
l
USB 2.0 and 3.0 compatible
l
Can charge a device at up to a full 2A
l
If only one device is connected to a
USB outlet the total output current of 2A is available from either outlet
l
If two devices are connected to USB
outlets the the total rated current of 2A is divided between the two outlets
l
Differing manufacturers devices can
be charged simultaneously via the two USB outlets
l
If the total charging current exceeds
the rated level of 2A then the device will enter a current limiting safety mode
l
Electronically protected against an
overload or short circuit on either USB outlet
l
USB outlets are designed to provide
optimum charging compatibility across a wide range of devices
l
Printed terminal markings on grey rear
mouldings for clearer identification
l
Top access, angled terminals make
wiring easier and quicker
l
3mm minimum switch contact gap
l
Double pole switching
l
Additional electrical safety from
neutral ‘make first’, ‘break last’ feature
l
Switch contacts with silver contacts
on both surfaces for good continuity
l
Backed out and captive terminal
screws
l
Dual earthed
Dimensions (mm)
444
Cable management
Aspect socket outlets can be mounted in a variety of MK trunking systems.
BOX TYPES WITHOUT PATRESS
GANG FLUSH
2 GANG
DEPTH 47MM
878 ZIC
146.4
40
86.4
33
Technical Hotline +44 (0)1268 563720
Wiring Devices Technical
2 Gang Switchsocket Outlet with Integrated Dual USB Charging Capability
Standards and approvals
EdgeTM 13A socket outlets and 2A USB charging outlets comply with BS 5733 and IEC 61558-2-16.
EMC Compatibility: IEC 61000-6-1 IEC 61000-6-3
Products are CE marked and meet the requirements of the Low Voltage, EMC, RoHS and WEEE directives.
WIRING DEVICES
– Edge™
TECHNICAL SPECIFICATION
13A SOCKET OUTLETS
ELECTRICAL
VOLTAGE RATING
220-240V
CURRENT RATING
13A Combined total 2A drawn from USB outlets
STANDBY POWER
150mW
TERMINAL CAPACITY
Live, neutral & earth 3 x 2.5mm 3 x 4mm 2 x 6mm2 (stranded)
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
2
2
Installation
EdgeTM socket outlets can be wall or bench mounted.
Do not mount or use as a trailing socket or where they may be subject to excessive moisture or damp.
Description
A range of socket outlets designed for ease of installation and having all the advantageous design features of the EdgeTM range. Dual USB charging outlets offer end users easy access to power for charging a variety of devices such as smart phones, tablets and cameras.
FEATURES
l
l
Matching metal rocker switches
l
3 pin operated safety shutter on 13A
socket outlets
l
USB 2.0 and 3.0 compatible
l
Can charge a device at up to a full 2A
l
If only one device is connected to a
USB outlet the total output current of 2A is available from either outlet
l
If two devices are connected to USB
outlets the the total rated current of 2A is divided between the two outlets
l
Differing manufacturers devices can
be charged simultaneously via the two USB outlets
l
If the total charging current exceeds
the rated level of 2A then the device will enter a current limiting safety mode
l
Electronically protected against an
overload or short circuit on either USB outlet
USB Outlets are designed to provide
optimum charging compatibility across a wide range of devices
l
Printed terminal markings on grey rear
mouldings for clearer identification
l
Top access, angled terminals make
wiring easier and quicker
l
3mm minimum switch contact gap
l
Double pole switching
l
Additional electrical safety from
neutral ‘make first’, ‘break last’ feature
l
Switch contacts with silver contacts
on both surfaces for good continuity
l
Backed out and captive terminal
screws
l
Dual earthed
Dimensions (mm)
Cable management
EdgeTM socket outlets can be mounted in a variety of MK trunking systems.
BOX TYPES WITHOUT PATRESS
GANG FLUSH
2 GANG
DEPTH 47MM
878 ZIC
146
120.6
40
86
35.7
445
Wiring Devices Technical – Albany Plus™
WIRING DEVICES
2 Gang Switchsocket Outlet with Integrated Dual USB Charging Capability
Standards and approvals
Albany Plus™ 13A socket outlets and 2A USB charging outlets comply with BS 5733 and IEC 61558-2-16.
EMC Compatibility: IEC 61000-6-1 IEC 61000-6-3
Products are CE marked and meet the requirements of the Low Voltage, EMC, RoHS and WEEE directives.
mkelectric.co.uk
TECHNICAL SPECIFICATION
13A SOCKET OUTLETS
ELECTRICAL
VOLTAGE RATING
220-240V
CURRENT RATING
13A Combined total 2A drawn from USB outlets
STANDBY POWER
150mW
TERMINAL CAPACITY
Live, neutral & earth 3 x 2.5mm 3 x 4mm 2 x 6mm2 (stranded)
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
2
2
Installation
Albany Plus™ socket outlets can be wall or bench mounted.
Do not mount or use as a trailing socket or where they may be subject to excessive moisture or damp.
Description
A range of socket outlets designed for ease of installation and having all the advantageous design features of the Albany Plus™ range. Dual USB charging outlets offer end users easy access to power for charging a variety of devices such as smart phones, tablets and cameras.
FEATURES
l
Moulded ‘on’ indicator flash on
switches will not rub off – totally safe
l
3 pin operated safety shutter on 13A
socket outlets
l
USB 2.0 and 3.0 compatible
l
Can charge a device at up to a full 2A
l
If only one device is connected to a
USB outlet the total output current of 2A is available from either outlet
l
If two devices are connected to USB
outlets the the total rated current of 2A is divided between the two outlets
l
Differing manufacturers devices can
be charged simultaneously via the two USB outlets
l
If the total charging current exceeds
the rated level of 2A then the device will enter a current limiting safety mode
l
Electronically protected against an
overload or short circuit on either USB outlet
l
USB outlets are designed to provide
optimum charging compatibility across a wide range of devices
l
Printed terminal markings on grey rear
mouldings for clearer identification
l
Top access, angled terminals make
wiring easier and quicker
l
3mm minimum switch contact gap
l
Double pole switching
l
Additional electrical safety from
neutral ‘make first’, ‘break last’ feature
l
Switch contacts with silver contacts
on both surfaces for good continuity
l
Backed out and captive terminal
screws
l
Dual earthed
Dimensions (mm)
446
Cable management
Albany Plus™ socket outlets can be mounted in a variety of MK trunking systems.
BOX TYPES WITHOUT PATRESS
GANG FLUSH
DEPTH 35MM DEPTH 40MM DEPTH 41MM
2 GANG
886 ZIC K2172 WHI
SURFACE
INSULATED
SURFACE
METAL
K2212ALM /
K2214ALM
146.1
40
85.8
27.7120.6
Technical Hotline +44 (0)1268 563720
Wiring Devices Technical
– Metalclad Plus™
2 Gang Switchsocket Outlet with Integrated Dual USB Charging Capability
Standards and approvals
Metalclad Plus™ 13A socket outlets and 2A USB charging outlets comply with BS 5733 and IEC 61558-2-16.
EMC Compatibility: IEC 61000-6-1 IEC 61000-6-3
Products are CE marked and meet the requirements of the Low Voltage, EMC, RoHS and WEEE directives.
WIRING DEVICES
TECHNICAL SPECIFICATION
13A SOCKET OUTLETS
ELECTRICAL
VOLTAGE RATING
220-240V
CURRENT RATING
13A Combined total 2A drawn from USB outlets
STANDBY POWER
150mW
TERMINAL CAPACITY
Live, neutral & earth 3 x 2.5mm 3 x 4mm 2 x 6mm2 (stranded)
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
2
2
Installation
Metalclad Plus™ socket outlets can be wall or bench mounted.
Do not mount or use as a trailing socket or where they may be subject to excessive moisture or damp.
Description
A range of socket outlets designed for ease of installation and having all the advantageous design features of the Metalclad Plus™ range. Dual USB charging outlets offer end users easy access to power for charging a variety of devices such as smart phones, tablets and cameras.
FEATURES
l
Moulded ‘on’ indicator flash on
switches will not rub off – totally safe
l
3 pin operated safety shutter on 13A
socket outlets
l
USB 2.0 and 3.0 compatible
l
Can charge a device at up to a full 2A
l
If only one device is connected to a
USB outlet the total output current of 2A is available from either outlet
l
If two devices are connected to USB
outlets the the total rated current of 2A is divided between the two outlets
l
Differing manufacturers devices can
be charged simultaneously via the two USB outlets
l
If the total charging current exceeds
the rated level of 2A then the device will enter a current limiting safety mode
l
Electronically protected against an
overload or short circuit on either USB outlet
l
USB outlets are designed to provide
optimum charging compatibility across a wide range of devices
l
Printed terminal markings on grey rear
mouldings for clearer identification
l
Top access, angled terminals make
wiring easier and quicker
l
3mm minimum switch contact gap
l
Double pole switching
l
Additional electrical safety from
neutral ‘make first’, ‘break last’ feature
l
Switch contacts with silver contacts
on both surfaces for good continuity
l
Backed out and captive terminal
screws
l
Metallic powder paint finish is
corrosion and scratch resistant
l
Dual earthed
l
High impact resistance
Dimensions (mm)
Cable management
Metalclad Plus™ socket outlets can be mounted in a variety of MK trunking systems.
BOX TYPES WITHOUT PATRESS
GANG FLUSH SURFACE
2 GANG
DEPTH 35MM
886 ZIC
DEPTH 38MM
K830 ALM (without knockouts)
K897 ALM and K897 WHI
(with 8 x 20mm knockouts)
146
85.8
40
27.7120.6
447
Wiring Devices Technical
T
T
test before use press button - T
white
off
(tripped)
red on
on
active control
device trips with
loss of mains
10mA tripping current
sentrysocket
rcd protected
WIRING DEVICES
Sentrysocket
Compliance with EC Directives, Standards and approvals
All Sentrysockets comply with the following EC Directives and are CE marked:
Low Voltage Directive Electromagnetic Compatibility Directive (89/336/EEC)
Sentrysocket RCD DP Single Sockets comply with the requirements of the following standards:
BS7288:1990 BSEN50082-1:1998
Sentrysocket RCD SP Double Sockets also comply with the requirements of BSEN61543:1996.
mkelectric.co.uk
Description
Sentrysocket provides a high level of protection against electrocution and gives further protection when used with appliances vulnerable to insulation damage, particularly when they are in damp environments or outdoors. The Sentrysocket units are not suitable for mounting in damp environments or outdoors.
Sentrysocket, incorporating an RCD, is part of a complete range of xed and portable wiring devices and circuit protection devices suitable for use in domestic, commercial and light industrial applications.
448
TECHNICAL SPECIFICATION
ELECTRICAL
RATED VOLTAGE
240V a.c.
CURRENT RATING
13A resistive Rated tripping current 10mA/30mA
TERMINAL CAPACITY
2
for 1 gang
3 x 4mm
2
for 2 gang
2 x 4mm
PHYSICAL
AMBIENT OPERATING TEMPERATURE
–5°C to +40°C
IP RATING
IP2XD IP66 (K56301/K56231/K56233)
MAX. INSTALLATION ALTITUDE
2000 metres
Sentrysockets are not suitable for connection across two lines of a 127V line to Neutral Voltage System
Cable management
Logic Plus™, Albany Plus™ and Metalclad Plus™ Sentrysockets can be mounted in a variety of MK trunking systems.
Installation
Flush mounting steel wall box
It should be noted that some of the conduit entries may be restricted, depending upon their positions and the depth of box used.
Active control circuits
Incorporate a ‘Re-set’ mechanism and are mains failure sensitive, i.e. they will function under all the normal conditions expected of an RCD, but will also trip in the event of a power cut or a sudden, dramatic reduction in mains voltage. This makes them ideal for use where it would be hazardous for equipment to suddenly energise after return of mains power, such as use with rotating machinery and heat developing apparatus.
Passive control circuits
Incorporate a ‘Stay-set’ mechanism and is mains failure proof, i.e. it will function under all the normal conditions expected of an RCD and will not trip in the event of a power cut. This makes it suitable for use with freezers or in inaccessible or unmanned locations.
FEATURES
l
Suitable for most residential,
commercial and light industrial applications
l
Active and passive control circuit
applications
l
Flexible and versatile in use
l
Single Sockets have double pole
switching, double sockets are single pole switching
l
Masterseal Plus products are ideal
for use with equipment subject to wet weather or high humidity
l
Part of a complete range of MK circuit
protection devices
l
They are a.c. and pulsating d.c.
sensitive for residual current
l
Double Socket products have an
enhanced RF Immunity performance
Sentrysockets products can be wall or bench mounted. Do not mount or use as a trailing socket or where they maybe subject to excessive moisture or dampness.
Dimensions (mm)
Double socketSingle socket
146 146
Flag below Reset (R) button.
Red : ON Black: OFF
sentrysocket
rcd protected
86
86
ALWAYS TEST BEFORE USE
Press Test (T) button, Red flag should disappear. If it does not, do not use.
Press Reset (R) after testing.
T R
120.6 120.6 9
26.53.3
Technical Hotline +44 (0)1268 563720
Sentrysocket
WIRING DEVICES
Wiring Devices Technical
Installation
Flush mounting steel wall box
It should be noted that some of the conduit entries may be restricted, depending upon their positions and the depth of box used.
Socket Testing
Single Socket Testing
After installation, turn the mains electricity supply on.
To test that the Sentrysocket is functioning correctly:
1. Ensure that no appliance is connected to the Sentrysocket.
Switch Sentrysocket on: The switch should remain closed
and the red ag will appear in the window. If the switch fails to remain closed, check that the Supply L and N connections are not reversed or the Supply N connection is not open circuit. If the Sentrysocket is correctly connected and still trips after being switched on, the Sentrysocket is faulty and should not be used.
2. If the Sentrysocket stays on, press the test button: The
switch will open and the white ag will appear In the window. If the Sentrysocket does not trip and there is mains voltage present at the socket outlet, Sentrysocket is faulty and should not be used.
3. Switch Sentrysocket on: Connect an RCD tester and ensure
that the Sentrysocket trips within the specied time:
≤ 200 ms AT RATED TRIP CURRENT ≤ 40 ms AT 5 x RATED TRIP CURRENT
If the Sentrysocket does not trip within the specied times then
the product is faulty and should not be used (If more than one RCD is in series then there is no guarantee as to which device will trip rst).
4. Reset all tripped RCD’s including the Sentrysocket.
5. Switch off the mains supply switch disconnector. On mains
failure, a Sentrysocket with Active Control Circuit will trip, whilst a Sentrysocket with Passive Control Circuit will not trip. If the Active Control device does not trip, it is faulty and should not be used – see note below. If no faults have been found then installation testing has been completed successfully.
Double Socket Testing
After installation, turn the mains electricity supply on.
To test that the Sentrysocket is functioning correctly follow the steps 1 to 4 below:
1. Ensure that no appliance is connected to the Sentrysocket.
2. Reset – Press the button marked R (for Reset) – the contact
status indicator should show red, indicating that the socket outlets are now live (if the switches are in the ON positions).
3. Test – Press the TEST button marked T (for Test), the product
should trip with the contact status indicator showing black. In this state the socket outlets are disconnected from the supply.
4. Reset – Press the button marked R again, the contact status
indicator should show red.
5. Connect an RCD Tester to either socket outlet and ensure that
the Sentrysocket trips with the specied times below:
≤ 200 ms AT RATED TRIP CURRENT ≤ 40 ms AT 5 x RATED TRIP CURRENT
6. Reset the Sentrysocket as in step 2 above.
7. Switch off the Mains Supply Switch Disconnector.
8. A Sentrysocket with Active Control Circuit should trip while a
Sentrysocket with Passive Control Circuit should not trip.
If all the operations in steps 2 to 8 above give correct results, the Sentrysocket RCD socket outlet is safe to use.
If the procedures in steps 2 to 8 above are not completed correctly, do not use the Sentrysocket product and seek professional advice or contact the MK Technical Sales and Service department on +44 (0)1268 563720.
Note: If a fault is identied at any stage of installation testing procedure do not use Sentrysocket, and contact your local electrician, or your local MK stockist.
449
Wiring Devices Technical
WIRING DEVICES
Filtered Switchsocket Outlets (Logic Plus and Albany Plus)
Standards and approvals
Filtered socket outlets comply with BS5733:2010.
TECHNICAL SPECIFICATION
ELECTRICAL
CURRENT RATING
13A maximum total for 2 sockets
VOLTAGE RATING
250V a.c.
EARTH LEAKAGE
0.5 mA
SUPPRESSION
150 kHz – 30 MHz (transients)
MAXIMUM ENERGY ABSORPTION
140 Joules L – N 140 Joules L – E
TERMINAL CAPACITY
2 x 6mm² 3 x 4mm² 3 x 2.5mm² 3 x 1.5mm²
PHYSICAL
AMBIENT OPERATING TEMPERATURE
-5°C to +40°C
THERMAL OVERLOAD
The K1826 and K2826 filter socket incorporates a thermal overload device in the RFI filter section. Overload current causes temperature rise, resulting in automatic ‘trip out’. The overload device will re-set as the temperature falls.
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
mkelectric.co.uk
Description
A range of sockets in the Logic Plus and Albany Plus styles, designed to combat interference to or data losses on sensitive electrical products and systems due to mains borne voltage spikes and RFI.
Such systems include:
l
Computer or microprocessor based equipment
l
Telecommunications systems
l
Electronic measurement equipment
l
Cash registers
l
Audio visual and hi- equipment
These products can be quickly installed as replacements for existing twin 13A sockets or in a new installation.
Fitted with two earth terminals to provide a double earth facility for use when installations require a high integrity protective connection as specied within the latest edition of BS7671.
Filter cassettes
Filter cassettes are supplied with sockets and have an LED which shows green under normal conditions but will turn red or extinguish when a replacement cassette (K1800WHI) is required. An alarm will also beep at 5 second intervals to indicate replacement necessity. It can be de-activated if required.
450
FEATURES
l
Moulded ‘on’ indicator flash on
switches will not rub off – totally safe
l
3 pin operated safety shutter
l
Printed terminal markings on grey rear
mouldings for clearer identification
l
Reduces risk of damage to equipment
and down time
l
Reduces risk of data loss
l
2 way filtering – into appliance and
back into mains supply
l
Additional electrical safety from DP
Switch, neutral ‘make first’, ‘break last’ feature
l
Double pole switches
l
Dual earth terminals for high integrity
earthing
l
Clearly visible LED on filter cassette,
changes from green to red when replacement required
l
Simple replacement of cassettes
l
10 year guarantee (except filter
cassette)
l
3mm minimum switch contact gap
l
Backed out and captive terminal
screws
Technical Hotline
Audible warning connector
Audible warning connector
Audible warning
+44 (0)1268 563720
Wiring Devices Technical
Filtered Switchsocket Outlets
WIRING DEVICES
Product features
Ensure that the connecting pins protruding from the bottom of the replacement Filter Cassette are not damaged or bent before installation. If in doubt, contact MK Technical Sales Service Department on +44 (0)1268 563720.
The MK Filtered Switchsocket, in common with many other lters uses Voltage Dependant Resistors for spike suppression purposes. The performance of these devices will eventually degrade with use to a level where they will no longer provide adequate protection.
When this occurs the spike ler performance of the MK Filtered Switchsocket outlet can be restored by replacing the lter cassette.
When the lter cassette needs replacing, the green indicator on the Replacement Filer Cassette will glow red or go out, an audible beep every ve seconds may also be heard.
Note: As with all lters, these Filter Sockets will reduce the magnitude of RFI and spikes and consequently their ability to interfere with connected equipment. They will not completely remove the interference from the supply.
Filter indicator
Figure 1
Audible warning connector
Replacement filter cassette
Figure 2
4. Fit the new lter cassette by carefully sliding it into the aperture
and gently pushing it down while turning the screw clockwise until the lter cassette is ush with the surface. Do not turn the screw any further as this will cause distortion of the plastic mouldings.
Product and packaging can safely be disposed of via standard
refuse facilities at the end of its useful life.
Figure 2a
Locking screw
Installation
Replaceable Spike Filter Cassette
Note: To ensure a safe installation;
l
this product should be installed by a competent person.
l
it is important that all connections are made as instructed.
1. The lter cassette can be removed and replaced without switching
off the mains or removing any plugs from the lter socket.
2. Remove the lter cassette by turning the jacking screw anti-
clockwise to partially eject it (see Figure 2), and then gently pulling the cassette upwards, (see Figure 2a).
3. Only t the MK Replacement Filter Cassette (K1800WHI).
Unpack the new ler cassette and check that the pins along the
bottom edge are not bent or broken. If these pins are damaged, do not t the replacement cassette. The audible sound indicating that the lter cassette needs replacing, is optional. It may be prevented by removing the small connector on the two end pins, (see Figure 2b), before tting it into the socket.
Figure 2b
connector
451
Wiring Devices Technical
WIRING DEVICES
Round Pin Socket Outlets
Standards and approvals
Round pin socket outlets comply with BS546:1950.
TECHNICAL SPECIFICATION
ELECTRICAL
VOLTAGE RATING
250V a.c.
TERMINAL CAPACITIES
2A sockets:
7 x 1mm² 4 x 1.5mm² 2 x 2.5mm² 1 x 4mm²
5A sockets:
3 x 2.5mm 2 x 4mm 2 x 6mm
15A sockets:
3 x 2.5mm² 3 x 4mm² 2 x 6mm² (stranded)
PHYSICAL
AMBIENT OPERATING TEMPERATURE
-5°C to +40°C
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
²
²
²
(stranded)
mkelectric.co.uk
Description
A range of round pin socket outlets designed for ease of installation and having all the advantages and design features of the MK range of wiring devices.
These products can be quickly installed as replacements for existing socket outlets or in new installations.
FEATURES
l
Top access terminals make wiring
easier and quicker
l
Integral ON indicator on plastic
switches will not rub off – totally safe
l
Switch contact gap, 3mm minimum
l
Double pole switching
l
Terminal screws backed out
l
Additional electrical safety from
neutral “make first”, “break last” feature on switched sockets
l
Switch contacts with silver contact
points on both surfaces for good continuity
l
5A and 15A sockets contain a 3 pin
operated safety shutter.
l
Printed terminal markings on grey rear
mouldings for clearer identification
452
Technical Hotline +44 (0)1268 563720
Wiring Devices Technical
Non UK Socket Outlets
WIRING DEVICES
Standards and approvals
15A American sockets comply with SASO2004:2003
16A 2P+E German sockets comply with IEC60884-1:2006
TECHNICAL SPECIFICATION
ELECTRICAL
15A AMERICAN
VOLTAGE RATING
127V a.c.
CURRENT RATING
15A
TERMINAL CAPACITY
Live, neutral & earth 3 x 2.5mm² 2 x 4mm² 1 x 6mm² (stranded)
MAX. INSTALLATION ALTITUDE
2000 metres
16A 2P+E GERMAN SOCKET
VOLTAGE RATING
250V a.c.
CURRENT RATING
16A
TERMINAL CAPACITY
Live, neutral & earth 4 x 1.5mm² 2 x 2.5mm² 1 x 4mm²
PHYSICAL
AMBIENT OPERATING TEMPERATURE
-5°C to +40°C
IP RATING
IP2XD
MAX. INSTALLATION ALTITUDE
2000 metres
15A AMERICAN (Logic Plus*)
BOX TYPES
GANG FLUSH
1 GANG 861ZIC 866ZIC K2140WHI
2 GANG 862ZIC 886ZIC K2142WHI
(FOR EXTRA WIRING SPACE)
FLUSH
SURFACE
16A 2P+E GERMAN (Logic Plus*)
BOX TYPES
GANG FLUSH SURFACE
1 GANG 861ZIC K2140WHI
2 GANG 862ZIC K2142WHI
Note: 16A 2P+E German Outlet: These products are NOT suitable for 25mm deep boxes.
*15A American Sockets and 16A 2P+E German Sockets are also available in a modular format for MK decorative wiring device ranges.
453
L2L1 N L2L1 N
N
Rear view of Fan Isolator
Rear view of Fan Isolator
Rear view of Fan Isolator
Rear view of Fan Isolator
L (switched)
N L
Supply
L2L1 N L2L1 N
N L (unswitched)
To Fan Unit with Timer (see Fan Unit Intructions)
L (switched)
N L
Supply
L2L1 N L2L1 N
N L (unswitched)
To Fan Unit with Timer (see Fan Unit Intructions)
L (switched)
N L
Supply
L2L1 N L2L1 N
N
To Fan Unit without Timer (see Fan Unit Intructions)
To Fan Unit without Timer (see Fan Unit Intructions)
L (switched)
N L
Supply
Three pole switching for fan units incorporating timers
Two pole switching for fan units without timers
TOP
TOP
TOP
TOP
Wiring Devices Technical
WIRING DEVICES
Three Pole Fan Isolators
Standards and approvals
Comply with BSEN60669-2-4:2005
TECHNICAL SPECIFICATION
ELECTRICAL
VOLTAGE RATING
250V a.c.
CURRENT RATING
10A
RATED CONDITIONAL SHORT CIRCUIT CURRENT (Inc)
3000A
TERMINAL CAPACITY
4 x 1mm² 4 x 1.5mm² 3 x 2.5mm² 2 x 4mm² 1 x 6mm²
CONTACT GAP
4mm switch contact gap
RECOMMENDED SCPD GE Power Controls TIA32M40 32A IEC269-2-1 Fuse-link
PHYSICAL
AMBIENT OPERATING TEMPERATURE
-5°C to +40°C
IP RATING
IP4X
MAX. INSTALLATION ALTITUDE
2000 metres
Features
l
Switchlock list no. K4858 is available to allow
the isolator to be locked in the disconnected position to facilitate fan maintenance
mkelectric.co.uk
Description
The MK Three Pole Fan Isolator provides a safe and simple method of isolating mechanical fan units and is particularly useful in bathrooms, toilets, storerooms and basements where there is little or no natural light.
For example, timer controlled fans are often linked into the lighting circuit for energy saving and convenience. In such an installation there is often a need for the lighting circuit to remain live to provide light whilst the fan unit is externally isolated so that routine maintenance and repairs can be carried out in complete safety.
The fan isolator can be used as a double pole or triple pole isolator. In addition it includes a clear on/off indicator and the frontplate features a fan isolator symbol for easy circuit identication.
Wiring diagrams
454