Please read through these instructions in order to familiarize yourself with the proper and safe procedures for operating the Lossnay.
After reading this manual, keep it in an easily accessible and safe place for future reference.
Safety precautions
The following signs indicate that death or serious injury may be caused by a failure to heed the precautions described below and the resultant
mishandling of the product.
English
WARNING
● This product must not be disassembled under any circumstances. Only authorized repair technicians are qualified to conduct
No
disassembly
Prohibited
Do not touch
Instructions
must be
followed
disassembly and repairs.
(Failure to heed this warning may result in fire, electrical shock or injury.)
If your product needs to be repaired, consult your dealer.
● Do not splash water over this product.
(Failure to heed this warning may result in fire and/or electrical shock.)
● If flammable gases should leak, do not turn the Lossnay’s switch on or off.
(Failure to heed this warning may cause the electrical contacts to generate sparks which may result in an explosion.)
Open windows to ventilate.
● Do not poke your fingers or sticks into the air intake and outlet while the product is operating.
(Failure to heed this warning may result in injury.)
● Gloves should be worn when doing the installation and maintenance work.
(Failure to heed this warning may result in injury.)
● Be sure that the power board circuit breaker is in the OFF position and is securely locked by lock and key before proceeding with
maintenance work.
(Failure to heed this warning may result in electrical shock or injury.)
● In the event of trouble (smell of burning, etc.), shut down operation, set the power board circuit breaker to its OFF position and
consult your dealer.
(Continued operation without remedying the trouble may result in electrical shock, fire, etc.)
1. For connection of a remote controller (PZ-41SLB-E)
If the Lossnay’s operation is linked with the operation of an external device such as an air conditioner, the method of use will differ, so carry out
the appropriate operation in accordance with the following table. Also, please see the installation and user’s manual for the remote controller
(PZ-41SLB-E).
<If not connected to an external device>
Example of SystemFunction
Lossnay
Remote Controller
(Optional parts)
Power Supply
(PZ-41SLB-E)
<If connected to an external device>
Remote Controller
Lossnay
Lossnay
Power Supply
Power Supply
External device
External device
(Optional parts)
(PZ-41SLB-E)
Power Supply
Operation switch for the external device
Power Supply
Operation switch for the external device
Operation
Run using the remote
controller.
If an external device is
connected the “On/Off”
function of this device will
also control the Lossnay
operation.
• If 2 remote controllers are used, the last
controller to be used has priority. (Last
Command)
• If you would like to turn ON the Lossnay
alone while the external device is OFF,
operate it by the Lossnay remote controller.
• The fan speed is on “High”.
• The ventilation mode is “Ventilation Mode
Auto Select”.
2. For connection of a Mitsubishi Electric
Air-Conditioner Network System
(MELANS) or City Multi.
This is to be incorporated and used in the Mitsubishi Electric AirConditioner Network System.
This is interlocked with the City Multi and operated by it.
Note
• Remote controller PZ-41SLB-E cannot be used with this system.
■ System diagram
Interlocked to the City Multi indoor unit
City Multi
indoor unit
A/C’s remote controller
M-NET transmission line
Lossnay unit
3-E
LGH-**RX
Power
supply
■ LOSSNAY VENTILATE setting
Both fresh air supply and return air pass through the Lossnay core(s).
Resulting in full heat exchange. Lossnay ventilate setting is used for
cooling in the summer and heating in the winter period.
Models LGH-F300, F470, F600RX3-E Model LGH-F1200RX3-E
Damper
Return air
Supply air
Exhaust air
Fresh air
Lossnay core
Damper
Return air
Supply air
Exhaust air
Fresh air
Lossnay core
■ BY-PASS VENTILATE setting
The fresh air passes through the Lossnay core(s) and the return
room air is exhausted direct. Lossnay bypass ventilate is normally
operated during the spring/autumn months.
Models LGH-F300, F470, F600RX3-E Model LGH-F1200RX3-E
Exhaust air
Fresh air
Lossnay core
Damper
Return air
Supply air
Exhaust air
Fresh air
Lossnay core
Damper
Return air
Supply air
■ AUTOMATIC VENTILATION setting
The automatic damper mode automatically provides the correct ventilation for the conditions in the room. The following shows the effect
“By-pass” ventilation will have under various conditions.
2
Page 3
Operation (Continued)
English
1. Reduces cooling load
If the air outside is cooler than the air inside the building during
the cooling season (such as early morning or at night), “By-pass”
ventilation will draw in the cooler outside air and reduce the cooling load on the system.
2. Night purge
“By-pass” ventilation can be used to release hot air from inside
the building that has accumulated in buildings a business district
during the hot summer season.
Maintenance
Remove all dust and dirt on air filters and Lossnay core(s) at regular
intervals in order to prevent a deterioration in the Lossnay functions.
Guideline:Clean the air filters once a year.
Clean the Lossnay core(s) once two year.
Removing the parts
1) Maintenance cover
Locate and remove the cover fixing screw. Pull back the hinged clip.
Open the door and lift off of the hinge brackets.
Hinge bracket
Maintenance cover
Hinge bracket
Maintenance covers
3. Office equipment room cooling
During cold season, outdoor air can be drawn in and used as is
to cool rooms where the temperature has risen due to the use of
office equipment.
(Only when interlocked with City Multi and Mr. Slim indoor unit)
Velcro
Lossnay core
Air filters
Hinge
Hinge
Models LGH-F300, F470, F600RX3-E Model LGH-F1200RX3-E
2) Lossnay core(s)
Take hold of the handle and draw the Lossnay cores out from the
main unit.
Model LGH-F300, F470, F600RX3-E: ....................... 2 cores
Models LGH-F300, F470, F600RX3-E Model LGH-F1200RX3-E
Lossnay
core
Handle
Cleaning the parts
1) Air filters
Use a vacuum cleaner to remove light dust. To remove stubborn dirt
wash in a mild solution of detergent and lukewarm water. (under 104°F)
Vacuum cleaner
Air filter
CAUTION
• Never wash the filters in very hot water and never wash them
by rubbing them.
• Do not dry the filters by exposing them to a flame.
2) Lossnay core
Use a vacuum cleaner to suck up the dust and dirt on the exposed
surfaces of the Lossnay cores. Use a soft brush only to clean exposed surface areas.
Do NOT wash in water.
Lossnay core
3) Air filters
After pulling out the Lossnay core(s), pull the air filters, located at
the bottom left and right of the Lossnay core(s), off the velcro that
holds them in place.
Model LGH-F300, F470, F600RX3-E: ....................... 4 filters
• Do not use the hard nozzle of the vacuum cleaner. It may damage the exposed surfaces of the Lossnay core(s).
• Under no circumstances should the Lossnay core(s) be washed
in water.
3
Page 4
Maintenance (Continued)
Assembly after maintenance
1. Bearing in mind the following points, assemble the parts following the
sequence for their removal in reverse.
• Align the air filter with the grooves on the Lossnay and holder and
push it in.
• When installing the air filters, take care not to damage the exposed
surfaces of the Lossnay cores.
Specifications
Air volume
(CFM)
Model name
LGH-
3
F300RX
LGHF470RX
LGHF600RX
-E
3
-E
3
-E
Voltage (V)
1-Phase
208 - 230
1-Phase
208 - 230
1-Phase
208 - 230
Line
frequency
(Hz)
Current (A)
601.327830069624473
602.55604706962441430.9650.539
602.9654600696244159
Power
consumption
(W)
2. Press the filter button on the remote controller (PZ-41SLB-E) two
times in succession.
(This clears the Lossnay’s operating time cumulative data.)
Relevant button
(Press twice)
Static
pressure
(in. H2O)
0.65
0.80
FILTER
Excharge efficiency (%)
Temperature
Relevant display items
Enthalpy
Heating Cooling
FILTER
Sound level (dB(A))
Below
the unit
36
39
Air
outlets
44
47
Weight
(Ibs)
LGHF1200RX
* The values given in the table for the sound level reflect the levels measured at a position 59 inch immediately below the unit in an anechoic
chamber.
* The sound at the air outlets is the values at a 45° angle, 59 inch in front of the unit.
* The above values apply during Lossnay ventilation when the fan speed is set to extra high speed.
* The values are under 230V 60Hz.
3
-E
1-Phase
208 - 230
605.712901200696244395
0.75
41
52
After-sales servicing
Consult with your dealer about the after-sales services provided for this
Lossnay product.
If you hear strange sounds, if no air is blown out or if some other
trouble occurs, switch off the power and contact your dealer.
Consult with your dealer concerning the cost of inspection or
repair work.
MITSUBISHI ELECTRIC CORPORATION
4