Mitsumi electronic AF1200CFMR, AF1200CFM User Manual

Air-Conditioners INDOOR UNIT
PEFY-AF1200CFM, PEFY-AF1200CFMR
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
MANUEL D’UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du climatiseur.
English
ON/OFF
FILTER
CHECK
CLEAR
MENU
ON/OFF
TEST
TEMP.
CLOCK
OPERATION
BACK DAY
MONITOR/SET
English
Français
Remote controller-Button Touche Commande à distance
English
Français
Remote controller-Display Affichage Commande à distance
1
2
3
B 7 A
0
4D5689C
1 Set Temperature button
2 Timer Menu button 3 Mode button
Monitor/Set button Back button
4 Timer On/Off button 5 Louver button
Set Day button Operation button
6 Fan Speed button 7 Vane Control button
8 Ventilation button
Operation button
9 Check/Clear button 0 Test Run button
A Filter button B ON/OFF button
button
C Location of built-in room temperature sensor D Set Time button
•Never expose the remote controller to direct sunlight. Doing so can result in the erroneous measurement of room temperature.
•Never place obstacles around the lower right-hand section of the remote con­troller. Doing so can result in the erroneous measurement of room tempera­ture.
A
TIME
SUN MON TUE WED THU FRI SAT
TIMER
˚C˚F
TEMP.
AFTER
ONLY 1Hr.
ERROR CODE
E
B
C
IN MGPJD
O
ON
OFFHrAFTER
˚C˚F
FUNCTION
FILTER
AUTO OFF
ON/OFF
H
A Time/Timer time B Centralized control indicator C Timer OFF indicator D Timer mode indicator E Operation mode display:
COOL, DRY, AU TO,
FAN, HEAT
F Function mode indicator G Preset temperature H Power indicator I Louver J Ventilation K Filter L Sensor position M Room temperature N Vane setting O Fan speed P Operation lamp
WEEKLY
SIMPLE
L F
K
1 Touche [Set Temperature] (Réglage de la température)
2
Touche [Timer Menu] (Menu de la minuterie)
Touche [Monitor/Set] (Contrôle/réglage)
Touche [Timer On/Off] (Minuterie Marche/Arrêt)
4
Touche [Set Day] (Réglage du jour)
6
Touche [Fan Speed] (Vitesse du ventilateur)7Touche [Vane Control] (Commande des ailettes)
3 Touche [Mode]
Touche [Back] (Retour en arrière)
5 Touche [Louver] (Louvre)
Touche [Operation] (Fonctionnement)
8 Touche [Ventilation]
Touche [Operation] (Fonctionnement)
Touche [Check/Clear] (Contrôler/effacer)
9
0 Touche [Test Run] (Essai de fonctionnement)
A Touche [Filter] (Filtre) B Touche [ON/OFF] (Marche/arrêt)
Touche [ ]
C Emplacement du capteur intégré de température de la pièce
D Touche de [réglage de l’heure]
• Ne jamais laisser la commande à distance en plein soleil sinon les données de température ambiante risquent d’être erronées.
• Ne jamais placer d’obstacle devant la partie inférieure droite de la commande à distance sinon la lecture des températures pourrait ne pas être correcte.
A Heure/heure de la minuterie B Témoin de commande à distance centralisée C Témoin de minuterie OFF D Témoin de mode de minuterie
Affichage du mode de fonctionnement
E
: COOL, DRY, AUTO,
FROID, DESHU, AUTO,
(
CHAUD)
F Témoin de mode de fonctionnement G Température prédéfinie H Témoin d’alimentation I Louvre J Ventilation K Filtre L Position du capteur M Température de la pièce N Réglage des ailettes O Vitesse du ventilateur P Témoin de fonctionnement
FAN, HEAT
VENTILATION,
2
Contents
1. Safety precautions ...................................................................................... 3
1.1. Installation ................................................................................. 3
1.2. During operation ........................................................................ 3
1.3. Disposing of the unit .................................................................. 4
2. How to operate ........................................................................................... 4
2.1. ON/OFF ..................................................................................... 4
2.2. Return air temperature adjustment ........................................... 4
2.3. Ventilation .................................................................................. 4
2.4. Others ........................................................................................ 5
1. Safety precautions
s Before operating the unit, make sure you read all the “Safety
precautions”.
s “Safety precautions” lists important points about safety.
Please be sure to follow them.
Symbols used in the text
Warning:
Describes precautions that should be observed to avoid the risk of injury or death to the user.
Caution:
Describes precautions that should be observed to prevent damage to the unit.
Symbols used in the illustrations
: Indicates an action that must be avoided.
: Indicates that important instructions must be followed.
: Indicates a part which must be grounded.
: Indicates that caution should be taken with rotating parts. (This symbol is
displayed on the main unit label.) <Color: yellow>
:Beware of electric shock. (This symbol is displayed on the main unit label.)
<Color: yellow>
Warning:
Carefully read the labels affixed to the main unit.
1.1. Installation
s After you have read this manual, keep it and the Installation Manual in a
safe place for easy reference whenever a question arises. If the unit is going to be operated by another person, make sure that this manual is given to him or her.
Warning:
• The unit should not be installed by the user. Ask the dealer or an author­ized company to install the unit. If the unit is installed improperly, water leakage, electric shock or fire may result.
• Use only accessories authorized by Mitsubishi Electric and ask your dealer or an authorized company to install them. If accessories are in­stalled improperly, water leakage, electric shock or fire may result.
• The Installation Manual details the suggested installation method. Any structural alteration necessary for installation must comply with local building code requirements.
•Never repair the unit or transfer it to another site by yourself. If repair is performed improperly, water leakage, electric shock or fire may result. If you need to have the unit repaired or moved, consult your dealer.
•Keep the electric parts away from water (washing water) etc.
• It might result in electric shock, catching fire or smoke. Note1:
When washing the Heat Exchanger and Drain Pan, ensure the Con-
trol Box, Motor and LEV remain dry, using a water proof covering.
Note2: Never drain the washing water for the Drain Pan and the Heat
• The appliance is not intended for use by young children or infirm per-
•Young children should be supervised to ensure that they do not play
• Do not use a leak detection additive.
1) Outdoor unit
• The outdoor unit must be installed on a stable, level surface, in a place
• Do not stand on, or place any items on the unit. You may fall down or the
Exchanger using the Drain Pump. Drain separately.
sons without supervision.
with the appliance.
Warning:
where there is no accumulation of snow, leaves or rubbish.
item may fall, causing injury.
3. Maintenance ............................................................................................... 5
4. Troubleshooting ........................................................................................... 6
5. Installation, reinstalling, and maintenance .................................................. 7
6. Specifications .............................................................................................. 7
Caution:
The outdoor unit should be installed in a location where air and noise emit­ted by the unit will not disturb the neighbours.
2) Indoor unit
Warning:
The indoor unit should be securely installed. If the unit is loosely mounted, it may fall, causing injury.
3) Remote controller
Warning:
The remote controller should be installed in such a way that children cannot play with it.
4) Drain hose
Caution:
Make sure that the drain hose is installed so that drainage can go ahead smoothly. Incorrect installation may result in water leakage, causing dam­age to furniture.
5) Power line, fuse or circuit breaker
Warning:
• Make sure that the unit is powered by a dedicated supply. Other appli­ances connected to the same supply could cause an overload.
• Make sure that there is a main power switch.
• Be sure to adhere to the unit’s voltage and fuse or circuit breaker ratings. Never use a piece of wire or a fuse with a higher rating than the one specified.
6) Grounding
Caution:
• The unit must be properly grounded. Never connect the grounding wire to a gas pipe, water pipe, lightning conductor or telephone grounding wire. If the unit is not grounded properly, electric shock may result.
• Check frequently that the ground wire from the outdoor unit is properly connected to both the unit’s ground terminal and the grounding electrode.
1.2. During operation
Caution:
• Do not use any sharp object to push the buttons, as this may damage the remote controller.
• Do not twist or tug on the remote controller cord as this may damage the remote controller and cause malfunction.
•Never remove the upper case of the remote controller. It is dangerous to remove the upper case of the remote controller and touch the printed circuit boards inside. Doing so can result in fire and failure.
•Never wipe the remote controller with benzene, thinner, chemical rags, etc. Doing so can result in discoloration and failure. To remove heavy stains, soak a cloth in neutral detergent mixed with water, wring it out thoroughly, wipe the stains off, and wipe again with a dry cloth.
•Never block or cover the indoor or outdoor unit’s intakes or outlets. Tall items of furniture underneath the indoor unit, or bulky items such as large boxes placed close to the outdoor unit will reduce the unit’s effi­ciency.
Warning:
• Do not splash water over the unit and do not touch the unit with wet hands. An electric shock may result.
• Do not spray combustible gas close to the unit. Fire may result.
• Do not place a gas heater or any other open-flame appliance where it will be exposed to the air discharged from the unit. Incomplete combustion may result.
3
Warning:
• Do not remove the front panel or the fan guard from the outdoor unit when it is running. You could be injured if you touch rotating, hot or high­voltage parts.
•Never insert fingers, sticks etc. into the intakes or outlets, otherwise in­jury may result, since the fan inside the unit rotates at high speed. Exer­cise particular care when children are present.
• If you detect odd smells, stop using the unit, turn off the power switch and consult your dealer. Otherwise, a breakdown, electric shock or fire may result.
• When you notice exceptionally abnormal noise or vibration, stop opera­tion, turn off the power switch, and contact your dealer.
• Do not over-cool. The most suitable inside temperature is one that is within 5 °C [41 °F] of the outside temperature.
• Do not leave handicapped people or infants sitting or standing in the path of the airflow from the air-conditioner. This could cause health problems.
Caution:
• Do not direct the airflow at plants or caged pets.
•Ventilate the room frequently. If the unit is operated continuously in a closed room for a long period of time, the air will become stale.
In case of failure
Warning:
•Never remodel the air conditioner. Consult your dealer for any repair or serv­ice. Improper repair work can result in water leakage, electric shock, fire, etc.
• If the remote controller displays an error indication, the air conditioner does not run, or there is any abnormality, stop operation and contact
your dealer. Leaving the unit as it is under such conditions can result in fire or failure.
• If the power breaker is frequently activated, get in touch with your dealer. Leaving it as it is can result in fire or failure.
• If the refrigeration gas blows out or leaks, stop the operation of the air conditioner, thoroughly ventilate the room, and contact your dealer. Leav­ing the unit as it is can result in accidents due to oxygen deficiency.
When the air conditioner is not to be used for a long time
• If the air conditioner is not to be used for a long time due to a seasonal change, etc., run it for 4 - 5 hours with the air blowing until the inside is completely dry. Failing to do so can result in the growth of unhygienic, unhealthy mold in scattered areas throughout the room.
• When it is not to be used for an extended time, keep the [power supply] turned OFF. If the power supply is kept on, several watts or several tens of watts will be wasted. Also, the accumulation of dust, etc., can result in fire.
•Keep the power switched ON for more than 12 hours before starting op­eration. Do not turn the power supply OFF during seasons of heavy use. Doing so can result in failure.
1.3. Disposing of the unit
Warning:
When you need to dispose of the unit, consult your dealer. If pipes are re­moved incorrectly, refrigerant (fluorocarbon gas) may blow out and come into contact with your skin, causing injury. Releasing refrigerant into the atmosphere also damages the environment.
2. How to operate
TIME
SUN MON TUE WED THU FRI SAT
TIMER
TEMP.
MENU
MONITOR/SET
CLOCK
AFTER
˚C˚F
ONLY 1Hr.
ON/OFF
E
1
2
BACK DAY
ERROR CODE
˚C˚F
OPERATION
ON
OFFHrAFTER
ON/OFF
FUNCTION
FILTER
WEEKLY
SIMPLE
AUTO OFF
FILTER
CHECK
CLEAR
TEST
8
Before starting operation
• Operate after the “PLEASE WAIT” display has disappeared. The “PLEASE WAIT” display briefly appears on the room temperature display (max. 3 minutes) when the power is turned on and after a power failure. This does not indicate failure of the air conditioner.
• Indoor unit operation mode is limited by the operation status of the connected outdoor unit. If an outdoor unit and some of the connected indoor units are already operating in the cooling mode, for example, only the cooling mode is available for the rest of the units in the same group. If a different mode is re­quested, the symbol that corresponds to the requested mode will blink, notify­ing the user that the mode is currently unavailable. The same is true for the dry and heating modes. This restriction, however, does not apply to the models that support a simultaneous cooling/heating function.
• The outdoor units stop operating when all the connected indoor units stop operating.
• During heating operation, even if the indoor unit is set to operation while the outdoor unit is in defrost, operation starts after defrost of the outdoor unit has ended.
P
B 7
2.1. ON/OFF
Start an operation
1. Press the B ON/OFF button
P Operation lamp lights up and operation starts.
Stop an operation
1. Press the B ON/OFF button again
Operation lamp goes off and operation stops.
• Once the buttons have been set, pressing the ON/OFF button only can repeat the same operation thereafter.
• During operation, the operation lamp above the ON/OFF button lights up.
Caution:
Even if the ON/OFF button is pressed immediately after the operation is once stopped, operation does not restart for about 3 minutes. This function protects the machine. It automatically starts operation after 3 minutes has lapsed.
2.2. Return air temperature adjustment
To change return air temperature
Press the 1 [Set Temperature] Button and set the return air temperature of your choice.
Pressing
If pressing continue, the setting continues to change by 1 °C [2 °F].
• Indoor temperature can be set within the following range.
* The range of return air temperature display is 8 °C [46 °F] - 39 °C [102 °F].
Outside this range, the display flashes either 8 °C [46 °F] - 39 °C [102 °F] to indicate if the return air temperature is lower or higher than the displayed tem­perature.
or
once changes the setting by 1 °C/1 °F.
PEFY-AF1200CFM :10 °C [50 °F] - 21 °C [70 °F] PEFY-AF1200CFMR :17 °C [63 °F] - 28 °C [83 °F]
2.3. Ventilation
• The ventilation unit (OA processing unit or LOSSNAY) automatically operation when the indoor unit that is interlocked with operates.
• If the 8 Ventilation button is pressed while the indoor unit is stopped, only the ventilator operates.
• Press the 8 Ventilation button to change the fan speed.
• Depending on the models, the indoor unit fan operates while the unit is in the ventilation mode.
4
2.4. Others
: Displayed when control is executed by a separately
STAND BY DEFROST
CHECK
: Displayed from the start up of heating operation until
: This display indicates if some abnormality is occur.
3. Maintenance
sold centralized control unit, etc.
the moment warm air blows out.
NOT AVAILABLE
FILTER
: When a button is pressed for a function the indoor
unit cannot perform, this display flashes concurrently with the display of that function.
: Displayed when it is time to clean the filter.
Press the A Filter ( disappear.
) button twice, then the display
Always have filters serviced by a qualified contractor. Before maintenance, turn the power supply OFF.
Caution:
• Before start cleaning, stop operation and turn OFF the power supply. Remember that the fan is rotating inside at high speed, posing a serious risk of injury.
• Indoor units are equipped with filters to remove the dust of from the air. Clean the filters following the procedures on the right. (The standard fil­ter should normally be cleaned once a week, and the long-life filter at the beginning of each season.)
• The life of the filter depends on where the unit is installed and how it is operated.
How to clean
•Brush dust away lightly or clean it up with a vacuum cleaner. In the case of severe staining, wash the filter in lukewarm water mixed with dissolved neutral detergent or water, and then rinse off the detergent completely. After washing, dry it and reattach it.
Caution:
• Do not dry the filter by exposing it to direct sunlight or warming it using fire, etc. Doing so can damage the filter.
•Washing the filter in hot water (more than 50 °C [122 °F]) can also result in damage.
Caution:
Never pour water or flammable sprays onto the air conditioner. Cleaning with these methods can result in air conditioner failure, electric shock, or fire.