Mitsubishi Heavy Industries SRK20ZIX-S, SRK25ZIX-S, SRK35ZIX-S, SRK50ZIX-S, SRK60ZIX-S User Manual

...
USER’S MANUAL
AIR-CONDITIONER
RKY012A006
SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S SRK50ZIX-S SRK60ZIX-S
MANUEL DE L’UTILISATEUR
CLIMATISEUR
ANWENDERHANDBUCH
KLIMAGERA¨T
ISTRUZIONI PER L’USO
CONDIZIONATORE D’ARIA
MANUAL DEL PROPIETARIO
ACONDICIONADOR DE AIRE
GEBRUIKERSHANDLEIDING
AIRCONDITIONING
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
КОНДИЦИОНЕР ВОЗДУХА
KULLANIM KILAVUZU
ENGLISH
DEUTSCH
ITALIANO
ESPAN˜OL
NEDERLANDS
PORTUGUÊS
РУССКИЙ
TÜRKÇE
FRANÇAIS
ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ
ΚΛΙΜΑΤΙΣΤΙΚΟ
ΕΛΛΗΝΙΚΑ
This air conditioner complies with EMC Directive 2004/108/EC, LV Directive 2006/95/EC.
Ce climatiseur est conforme à la Directive EMC: 2004/108/EC, LV Directive 2006/95/EC.
Dieses Kimagerät erfüllt die EMC Direktiven 2004/108/EC, LV Direktiven 2006/95/EC.
Questo condizionatore d’aria è conforme alla Direttiva EMC: 2004/ 108/EC, LV Direttiva 2006/95/EC.
Deze airconditioner voldoet aan EMC Directive 2004/108/EC, LV Directive 2006/95/EC.
Este acondicionador de aire cumple con la directiva EMC: 2004/ 108/EC, LV Directiva 2006/95/EC.
Este aparelho de ar condicionado está em conformidade com a Directiva EMC 2004/108/EC e a Directiva LV 2006/95/EC.
–1–
Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES, LTD. Air-Conditioner. To get the best long-lasting performance, please read and follow this User’s Manual carefully
before using your air-conditioner. After reading, please store the Manual in a safe place and refer to it for operational questions or in the event of any irregularities.
This air-conditioner is intended for domestic use.
Do not vent R410A into the atmosphere: R410A is a fluorinated greenhouse gas, covered by the Kyoto Protocol with a Global Warming Potential (GWP) = 1975.
contents
ENGLISH
Your Air Conditioning product may be marked with this symbol. It means that waste electrical and electronic equipment (WEEE as in directive 2002/ 96/EC) should not be mixed with general household waste. Air conditioners should be treated at an authorized treatment facility for re-use, recycling and recovery and not be disposed of in the municipal waste stream. Please contact the installer or local authority for more information.
This symbol printed in the batteries attached to your Air Conditioning product is information for end-users according to the EU directive 2006/66/ EC article 20 annex II. Batteries, at their end-of-life, should be disposed of separately from general household waste. If a chemical symbol is printed beneath the symbol shown above, this chemical symbol means that the batteries contain a heavy metal at a certain concentration. This will be indicated as follows: Hg:mercury(0.0005%) , Cd:cadmium(0.002%) , Pb:lead(0.004%) Please, dispose of batteries correctly at your local community waste collection or the recycling center.
Safety precautions........................................... 2
Name of each part and its function ................. 4
Remote control handling ................................ 6
Operation failure with the remote control ...... 6
Temporary run operation ................................6
Operation and display section for remote
control ............................................................. 7
Current time setting ........................................ 7
AUTO mode operation ................................... 8
Temperature adjustment during AUTO .......... 8
FAN SPEED ...................................................8
COOL/HEAT/DRY/FAN mode operation ..... 9
Air-conditioner operable
temperature setting ......................................... 9
Characteristics of HEAT mode operation ...... 9
Airflow direction adjustment ........................ 10
3D AUTO operation ..................................... 10
SLEEP TIMER operation ............................. 11
OFF-TIMER operation .................................11
ON-TIMER operation................................... 12
SLEEP TIMER + ON-TIMER operation ..... 12
PROGRAM TIMER operation ..................... 13
ALLERGEN CLEAR operation ................... 13
HIGH POWER/ECONOMY operation ........ 14
SELF CLEAN operation .............................. 15
Auto restart function ..................................... 15
Tips for effective operation .......................... 15
Installation location setting ........................... 16
Maintenance.................................................. 17
Proper installation ......................................... 19
Troubleshooting ............................................ 19
Notice ........................................................... 20
Contact your dealer ....................................... 21
About the Multiple Air-conditioner.............. 21
Self diagnosis function ................................. 22
–2–
Safety precautions
Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system.
The safety precautions are classified as “
DANGER” and “ CAUTION”. Precautions as shown in the column “ DANGER” indicate that
improper handling could lead to drastic result like death, serious injury, etc. Even precautions as shown in the column “
CAUTION” might pose
a serious problem, depending on the circumstances. Please observe these precautions with great care, since they are essential to your safety.
Symbols which appear frequently in the text have the following meaning:
When you have read this instruction manual, please keep it without missing. If someone else takes over as operator, make certain that the manual is
also passed on to the new operator.
Strictly prohibited Provide proper earthing
Observe instructions with great care
INSTALLATION PRECAUTIONS
DANGER
OPERATION PRECAUTIONS
DANGER
Make sure that the system has been properly earthed.
Depending on the place of installation, an earth leakage breaker may be necessary.
Do not install it where flammable gas may leak.
Make sure to install the drain hose properly so that all the water is drained out.
The system is for domestic, residential etc. use. The system must be installed by your dealer or a qualified pro-
fessional.
If used in severer environments, such as an engineering workplace, the equipment may function poorly.
It is not advisable to install the system by yourself, as faulty handling may cause leakage of water, electric shock or fire.
Gas leaks may cause fire. If you do not install an earth leakage breaker, you may get an
electric shock.
Improper installation may lead to water drop in the room resulting in wet furniture.
Earth cables should never be connected to a gas pipe, water pipe, lightning conductor or telephone earth cable. Incorrect installa­tion of the earth cable may produce an electric shock.
Do not expose yourself to the cooling air for a long period.
Store the remote control out of reach of infants.
Do not swing from the indoor unit.
This could affect your physical condi­tion and cause health problems.
This may cause injury, as the inter­nal fan rotates at high speed.
Failure to observe this may result in the batteries being swallowed or other accidents.
Use of steel or copper wire instead of an approved fuse is strictly prohibited, as it may cause a break­down or fire.
This may cause an electric shock. If the indoor unit falls down,
you may get injured.
CAUTION
Do not wash the air-conditioner with wa­ter.
You should not expose any combus­tion appliance directly to the air stream of the air-conditioner.
Do not place a flammable insecticide or paint spray near the blower, nor spray it directly on the system.
This may result in a fire. The appliance may then work inad-
equately.
This could cause an electric shock.
Do not insert anything into the air inlet.
Do not handle the switches with wet hands.
Only use approved fuses.
CAUTION
–3–
Safety precautions
CAUTION
PRECAUTIONS FOR RELOCATION OR REPAIRS
DANGER
Stand firmly on a stepladder or other stable object when removing the inlet panel and filters.
Do not place objects near the outdoor unit or allow leaves to gather around the unit.
Do not place anything containing wa­ter, like vases, on top of the unit.
The system should only be used for its original purpose and not for anything else like, for instance, preservation of food, plants or animals, precision devices or works of art.
Do not install the system where the airflow direction is aimed directly at plants or animals.
Do not sit on the outdoor unit nor put anything on it.
After a long period of use, check the unit's support structure from time to time.
Do not touch the aluminum fins on the air heat exchanger.
If you operate the system together with a combustion appliance, you must regularly ventilate the indoor air.
When you clean the system, stop the unit and turn off the power supply.
Do not place household electrical appli­ances or household items under neath the indoor or outdoor units.
Contact your dealer to clean inside the indoor unit, do not attempt to do by yourself.
Stop the unit and turn off the power if you hear thunder or there is a danger of lightning.
The system is only intended for use in ordinary domestic rooms. Any other use of the system may damage the quality of food, etc.
Water entering the unit could dam­age the insulation and therefore cause an electric shock.
This will damage their health.
If the unit falls down or things drop off it, people could get hurt.
If you do not repair any damage right away, the unit may fall down and cause personal injury.
It may result in injury.
Condensation falling from the unit may stain objects and cause accidents or electrical shock.
Insufficient ventilation may cause accidents due to oxygen deficiency.
Failure to observe this may result in injury through insecure objects top­pling over.
Never open the panel while the internal fan is rotating.
If there are objects or leaves around the outdoor unit, small animals may enter unit and contact electri­cal parts and may cause a break­down, smoke or fire.
The use of a non-approved detergent or improper washing method may damage the unit’s plastic compo­nents and cause leaks. Damage, smoke, or fire may also happen if the detergent comes in contact with electrical parts or the unit’s motor.
It may damage the unit.
Consult your dealer for repairs.
If you notice anything abnormal (smell of burning, etc.), stop the system, turn off the power supply and consult your dealer.
In case the air-conditioner is relocated elsewhere, contact your dealer or a professional fitter.
If the air-conditioner fails to cool or warm the room, it may have a refrigerant leakage. Contact your dealer. If refrigerant needs to be added, check with your dealer for proper instructions.
Wrong repairs could cause an electric shock, fire, etc.
Faulty installation may cause water leakage, electric shock, fire, etc.
Continued use of the system in ab­normal circumstances may result in malfunctioning, electric shock, fire, etc.
The refrigerant used in your air-conditioner is safe. However, if refrigerant unexpectedly leaks from the unit onto a fan heater, stove, hotplate or other heat source, harmful gases could be generated.
–4–
Name of each part and its function
INDOOR UNIT
Air filter
Removes dust or dirt from the inlet air.
Page 17
Air Inlet panel
Draws the indoor air. Page 17
Drain hose
Drains water from the indoor unit.
Left/right airflow direction adjustment louver
Page 10
Up/down airflow direction adjustment flap
Page 10
Air outlet
Air blows out of here.
Heat exchanger
Room temperature sensor
Air-cleaning filter
Refrigerant piping connection and electric wire
Indoor unit fan
Air Inlet top panel
OUTDOOR UNIT
Air outlet
Air inlet
(On side & rear surface)
Outdoor unit fan
Heat exchanger
Page 18
Page 17
–5–
Unit display section
3D AUTO light (green)
Illuminates during 3D AUTO operation.
HI POWER light (green)
Illuminates during HIGH POWER operation.
TIMER light (yellow)
Illuminates during TIMER operation.
This button can be used for turning on/off the unit when remote control is not available.
Page 6
Remote control signal receiver
Unit ON/OFF button
Name of each part and its function
CAUTION
Do not touch the air inlet panel while it is operating.
The air inlet panel opens up while the system is operating. Please do not install the unit in a fashion in which the air inlet panel cannot open or place objects near the indoor unit.
RUN (HOT KEEP) light (green/blue)
Illuminates during operation.
green : except ECONO operation blue : ECONO operation
Blinks when airflow stops due to the ‘HOT KEEP’
and ‘CLEAN operation
’.
Page 15
ON
OFF
1.5 sec.
0.5 sec.
HOT KEEP
3 sec.
1 sec.
ON
OFF
CLEAN operation
Buzzer sound for remote control
When preset temperature 24°C, automatic operation and automatic airflow are selected, the buzzer sound (PiPi) is produced. When turning off the air conditioner by pressing ON/OFF button (except CLEAN mode), the buzzer sound (Pi) is produced. This function is useful for operating the air conditioner in the darkness.
NOTE
Preset temperature
Air flow setting
–6–
Remote control handling
Replacing the batteries
The following cases signify exhausted batteries. Replace old batteries with new ones.
Receiving beep is not emitted when a signal is transmitted.
Display fades away.
NOTE
Do not use old and new batteries together.
Remove the batteries when the remote control is not used for a long period.
The recommended effective period of a battery conforming to JIS or IEC should be
6 to 12 months with normal use. If used longer, or when an unspecified battery is used, liquid may leak from the battery, causing the remote control to malfunction.
The recommendable effective period is printed on the battery. This may be shorter
due to manufacturering time to the unit. However, the battery may still be in working order after expiry of its nominal life.
Pull out the cover and take out old batteries.
Insert new batteries. R03 (AAA, Micro) x2
Close the cover.
When the display shows any abnormal condition, Press the ACL switch with the tip of a ballpoint pen.
1 2
3
Pay attention to the ª and ·
marks
Press the ACL switch with the tip of a ballpoint pen.
The timer setting mode is displayed.
Page 7
4
Using the remote control holder
The remote control can be attached to a wall or pillar by using a remote control holder. Before installing the remote control, check that the air-conditioner receives the signals properly.
For installing or removing the remote control, move it up or down in the holder.
Are the batteries running down?
“Replacing the batteries” above.
Replace the batteries with new ones and retry the operation.
Warning note for remote control handling
Operation failure with the remote control
If the operation fails, operate the unit with
temporary operation function. Contact your dealer to have the remote control checked.
Below
Strictly prohibited
Do not drop the remote control. Handle with care.
Do not go near high temperature places, such as an electric carpet or stove.
Do not place heavy objects on the remote control, or step on it.
Do not put any obstructing obsta­cles between the remote control and the unit.
Do not spill any liquid on the remote control.
Do not leave the remote control ex­posed to direct sunlight or other strong lighting.
Temporary run operation
The unit ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.
Operation program
OPERATION MODE : AUTO
FAN SPEED : AUTO
AIR FLOW : AUTO
Operation starts by pressing the unit ON/OFF button; it stops if you press
the button again.
Unit ON/OFF button
Do not hold the Unit ON/OFF button down for more than 5 seconds.
(Holding it down longer than 5 seconds sets the automatic cooling used during servicing or when relocating the air-conditioner.)
NOTE
–7–
Operation section
FAN SPEED button
Each time the button is pressed, the display is switched over in turn.
The above illustration shows all controls, but in practice only the relevant parts are shown.
OPERATION MODE select button
Each time the button pressed, the display is switched over in turn.
ON/OFF (luminous) button
Press to start operation, press again to stop.
HI POWER/ECONO button
This button changes the HIGH POWER/ ECONOMY mode.
Page 14
Page 8
AIR FLOW (UP/DOWN) button
This button changes the air flow (up/down) direction.
This button changes the air flow (left/right) direction.
Page 10
SLEEP button
This button selects SLEEP operation.
Page 11
CLEAN switch
This switch selects the CLEAN mode.
Page 15
ON TIMER button
This button selects ON TIMER operation.
Page 12
AIR FLOW (LEFT/RIGHT) button
Page 10
3D AUTO button
This button sets 3D AUTO operation.
This button selects ALLERGEN CLEAR operation.
ALLERGEN CLEAR button
ACL switch
This switch is for resetting microcomputer and setting time.
Page 6
Page 13
OFF TIMER button
This button selects OFF TIMER operation.
Page 11
TEMPERATURE button
These buttons set the room temperature. (These buttons are used for setting the current time and timer function as well.)
Page 10
This button cancels the ON timer, OFF timer, and SLEEP operation.
CANCEL button
Page 8, 9
Operation and display section for remote control
Transmission procedure
When each button on the remote control is pressed – with the remote control pointing towards the air-conditioner unit a signal is transmitted. When the air-conditioner receives the signal correctly, it will beep.
NOTE
2
Current time setting
When inserting the batteries, the current time is automatically set to time setting mode.
13:00 is displayed as the current time. Set the clock to the right time.
Example: Set to 10:30.
Press the ACL switch.
Press with the tip of a ballpoint pen, etc. The time display blinks and can be set to the current time.
Press the “ or ” button.
(Set to 10:30)
Press the ON/OFF button.
The display changes from blinking to steady lighting and the setting is complete. Make sure to press the button within 60 seconds from the last operation in step 2, otherwise the time is not set.
The timer operation works based on the time clock, so please set it correctly.
The remote control data is reset when the present time is set.
1
3
Loading...
+ 16 hidden pages