Mitsubishi Heavy Industries SRK50HE-S, SRK56HE-S, SRK50CE-S, SRK56CE-S Technical Manual

WALL MOUNTED TYPE ROOM AIR-CONDITIONER
(Split system, air to air heat pump type) SRK50HE-S, SRK56HE-S
(Split system, air cooled cooling only type) SRK50CE-S, SRK56CE-S
TECHNICAL MANUAL
& PARTS LIST
INDOOR UNIT
Models SRK50HE-S, SRK56HE-S
SRK50CE-S, SRK56CE-S
OUTDOOR UNIT
Models SRC50HE-S, SRC56HE-S
SRC50CE-S, SRC56CE-S
REMOTE CONTROLLER
-
1
-
Error of signal transmission
1 GENERAL INFORMATION
1.1 Specific features
The “Mitsubishi Daiya” room air-conditioner: SRK series are of split and wall mounted type and the unit consists of indoor unit and
outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling or heating equipment with opera-
tion control switch and the outdoor unit is composed of condensing unit with compressor.
(1) Remote control flap
The flap can be automatically controlled by operating wireless remote controller.
¡ Air scroll: Flap operation is automatically control.
¡ Swing: This will swing the flap up and down.
¡ Memory flap: Once the flap position is set, the unit memorizes the position and continues to operate at the same position from
the next time.
(2) Automatic operation
When the remote control switch is set on “auto( ) ”, it will either automatically decide operation mode such as cooling, heating
and thermal dry, or operate in the operation mode before it has been turned to automatic control.
(3) Self diagnosis function
¡ We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation as
follows.
1.2 How to read the model name
Example : SR K 50 H E - S
Room temperature sensor error
Indoor fan motor error
Heat exchanger sensor error
2 time flash
6 time flash
TIMER light
ON
1 time flash
Outdoor unit heat exchanger sensor error
Discharge pipe sensor error
Outdoor temperature sensor error
2 time flash
4 time flash
RUN light keeps flashing
1 time flash
OFF
OFF
OFF
Over heat of compressor
5 time flash
RUN light
ON
5 time flash
6 time flash 6 time flash
RUN light TIMER light Outdoor (LED)
R410A models
Series No.
H: Heat pump type
C: Cooling only type
Product capacity
Wall mounted type
Split type room air-conditioner
2 time flash OFF
Abnormality of outdoor unit
-
2
-
Item
Model
SRK50HE-S SRC50HE-S
Cooling capacity
(1)
W 4700
Heating capacity
(1)
W 5300
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 1.41 Running current (Cooling) A 6.5/6.3/6.0 Heating input kW 1.40 Running current (Heating) A 6.5/6.2/6.0 Inrush current A 39.6
COP Cooling: 3.33 Heating: 3.79
Cooling
Sound level Hi 43, Me 39, Lo 34 47
Noise level
Power level
dB
58 63
Heating
Sound level Hi 44, Me 39, Lo 35 49
Power level 61 64
Exterior dimensions
Height × Width × Depth
mm
298 × 840 × 259 640 × 850 × 290
Color Cool white Stucco white Net weight kg 12 44 Refrigerant equipment
Compressor type & Q’ty
RM-B5118MNE5 (Rotary type) × 1
Motor kW 1.4
Starting method Line starting Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Refrigerant
(3)
kg R410A 1.4 (Pre-Charged up to the piping length of 15m) Refrigerant oil R 0.7 (MA68) Deice control Microcompter control
Air handling equipment Fan type & Q’ty
Tangential fan × 1 Propeller fan × 1
Motor W 27 35
(Cooling) 10.0 38.0
Air flow (at High)
(Heating)
CMM
12.5 38.0
Air filter, Q’ty Polypropylene net (washable) × 2–
Shock & vibration absorber Cushion rubber (for compressor) Electric heater –– Operation control
Operation switch
Wireless-Remote controller
Room temperature control Microcomputer thermostat Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ12.7 (1/2″) Connecting method Flare Connection Attached length of piping Liquid line: 0.54 m
Gas line : 0.47 m
Insulation Necessary (Both sides) Drain hose Connectable Power source cord 2 m (3 cores with earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter × 1, Photocatalytic washable deodorizing filter × 1)
Optional parts
Notes (1) The data are measured at the following conditions.
2 SELECTION DATA
2.1 Specifications
Model SRK50HE-S (Indoor unit)
SRC50HE-S (Outdoor unit)
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC 6ºC ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 25 m, add 20 g refrigerant per meter.
Operation data
(2)
Refrigerant
piping
Compressor: Overheat protection, Serial signal error protection, Indoor fan motor error protection, Frost protection
The piping length is 7.5m.
-
3
-
Item
Model
SRK56HE-S SRC56HE-S
Cooling capacity
(1)
W 5100
Heating capacity
(1)
W 5800
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 1.59 Running current (Cooling) A 7.3/7.1/6.8 Heating input kW 1.58 Running current (Heating) A 7.4/7.1/6.8 Inrush current A 45.2
COP Cooling: 3.21 Heating: 3.67
Cooling
Sound level Hi 44, Me 40, Lo 35 49
Noise level
Power level
dB
59 64
Heating
Sound level Hi 44, Me 39, Lo 35 51
Power level 61 65
Exterior dimensions
Height × Width × Depth
mm
298 × 840 × 259 640 × 850 × 290
Color Cool white Stucco white Net weight kg 12 44 Refrigerant equipment
Compressor type & Q’ty
RM-B5120MNE5 [Rotary type] × 1
Motor kW 1.5
Starting method Line starting Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Refrigerant
(3)
kg R410A 1.4 (Pre-Charged up to the piping length of 15m) Refrigerant oil R 0.7 (MA68) Deice control Microcomputer control
Air handling equipment Fan type & Q’ty
Tangential fan × 1 Propeller fan × 1
Motor W 27 35
(Cooling) 11.0 38.0
Air flow (at High)
(Heating)
CMM
12.5 38.0
Air filter, Q’ty
Polypropylene net (washable) × 2
Shock & vibration absorber Cushion rubber (for compressor) Electric heater –– Operation control
Operation switch
Wireless-Remote controller
Room temperature control Microcomputer thermostat Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ12.7 (1/2″) Connecting method Flare connection Attached length of piping Liquid line: 0.54 m
Gas line : 0.47 m
Insulation Necessary (Both sides) Drain hose Connectable Power source cord 2 m (3 cores with earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter × 1, Photocatalytic washable deodorizing filter × 1)
Optional parts
Notes (1) The data are measured at the following conditions.
Model SRK56HE-S (Indoor unit)
SRC56HE-S (Outdoor unit)
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC 6ºC ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 25 m, add 20 g refrigerant per meter.
Operation data
(2)
Refrigerant
piping
Compressor: Overheat protection, Serial signal error protection, Indoor fan motor error protection, Frost protection
The piping length is 7.5m.
-
4
-
Item
Model
SRK50CE-S SRC50CE-S
Cooling capacity
(1)
W 4700
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 1.41 Running current (Cooling) A 6.5/6.3/6.0 Inrush current A 39.6
COP Cooling: 3.33
Cooling
Sound level Hi 43, Me 39, Lo 34 47
Noise level
Power level
dB
58 63
Exterior dimensions
Height × Width × Depth
mm
298 × 840 × 259 640 × 850 × 290
Color Cool white Stucco white Net weight kg 12 44 Refrigerant equipment
Compressor type & Q’ty
RM-B5118MNE5 (Rotary type) × 1
Motor kW 1.4
Starting method Line starting Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Refrigerant
(3)
kg R410A 1.4 (Pre-Charged up to the piping length of 15m) Refrigerant oil R 0.7 (MA68) Deice control Microcomputer control
Air handling equipment Fan type & Q’ty
Tangential fan × 1 Propeller fan × 1
Motor W 27 35
Air flow (at High) (Cooling) CMM 10.0 38.0 Air filter, Q’ty Polypropylene net (washable) × 2–
Shock & vibration absorber Cushion rubber (for compressor) Electric heater –– Operation control
Operation switch
Wireless-Remote controller
Room temperature control Microcomputer thermostat Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ12.7 (1/2″) Connecting method Flare connection Attached length of piping Liquid line: 0.54 m
Gas line : 0.47 m
Insulation Necessary (Both sides) Drain hose Connectable Power source cord 2 m (3 cores with earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter × 1, Photocatalytic washable deodorizing filter × 1)
Optional parts
Notes (1) The data are measured at the following conditions.
Model SRK50CE-S (Indoor unit)
SRC50CE-S (Outdoor unit)
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 25 m, add 20 g refrigerant per meter.
Operation data
(2)
Refrigerant
piping
Compressor: Overheat protection, Serial signal error protection, Indoor fan motor error protection, Frost protection
The piping length is 7.5m.
Loading...
+ 13 hidden pages