Mitsubishi Heavy Industries SRK20ZMA-S, SRK25ZMA-S, SRK35ZMA-S, SRK50ZMA-S Technical Manual & Parts List

RESIDENTIAL AIR-CONDITIONING
TECHNICAL MANUAL & PARTS LIST
WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type)
SRK20ZMA-S SRK25ZMA-S SRK35ZMA-S SRK50ZMA-S
Manual No.'14
SRK-T-154
-
1
-
'14 • SRK-T-154
TECHNICAL MANUAL
-
2
-
'14 • SRK-T-154
gs32+4
CONTENTS
1. SPECIFICATIONS ........................................................................................ 4
(2) Outdoor units ....................................................................................... 9
..................................................... 23
2EMOTECONTROL
..................................................................................... 12
......................................................................... 8
(1) Indoor units .......................................................................................... 8
2. EXTERIOR DIMENSIONS
3. ELECTRICAL WIRING .............................................................................. 14
(1) Indoor units .......................................................................................... 14
4. NOISE LEVEL ............................................................................................ 17
(2) Outdoor units 
6. RANGE OF USAGE & LIMITATIONS
................................................................................... 25
7. CAPACITY TABLES
5. PIPING SYSTEM ...................................................................................... 21
.................................................................................. 27
8. APPLICATION DATA
9. OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER ............... 39
4IMEROPERATION
.................................................................................. 44
(9) $AUTOOPERATION
........................................................................... 43
............................... 40
/PERATIONCONTROLFUNCTIONBYWIRELESSREMOTECONTROL
&LAPANDLOUVERCONTROL ...................................................................... 42
3ELECTIONOFTHEANNUALCOOLINGFUNCTION .............................................. 41
)NSTALLINGTWOAIRCONDITIONERSINTHESAMEROOM
......................................................................... 40!UTORESTARTFUNCTION
5NIT/./&&BUTTON
........................................................................... 40
....................... 39
3ILENTMODE .................................................................................... 44
)NSTALLATIONLOCATIONSETTING ........................................................... 44
.IGHTSETBACK .................................................................................. 44
/UTLINEOFHEATINGOPERATION 
/UTLINEOFDRYDEHUMIDIFYINGOPRATION .............................................. 47
/UTLINEOFCOOLINGOPERATION ............................................................... 46
)NSTALLATIONOFINDOORUNIT ...................................................................... 27
)NSTALLATIONOFOUTDOORUNIT .................................................................. 31
%CONOMYOPERATION
.............................................................................. 41
(IGHPOWEROPERATION ........................................................................... 41
/UTLINEOFAUTOMATICOPERATION ........................................................... 47
0ROTECTIVECONTROLFUNCTION
................................................................... 48
$2%$

-
3
-
'14 • SRK-T-154
(10) How to make sure of wireless remote control ...................................... 74
(12) Outdoor unit inspection points .............................................................. 75
(11) Inspection procedure for blown fuse on the indoor and outdoor PCB .... 74
(8)
Phenomenon observed after shortcircuit, wire breakage on sensor
......... 72
(9) Checking the indoor electrical equipment
........................................... 72
How to read the model name
Example: SRK 20 Z
Series code
Inverter type
Product capacity (Cooling capacity : 2.0kW)
Model name SRK : Wall mounted type
SRC : Outdoor unit
MA-S
........................................................................................... 78
11. OPTION PARTS
.............................................................. 78
..................................................................... 84
(1) Wired remote control (RC-E5) (2) Interface kit (SC-BIKN-E)
(3) Super link E board (SC-ADNA-E) .......................................................... 88
(6) Service mode (Trouble mode access function) ................................... 59
(7) Inspection procedures corresponding to detail of trouble .................... 67
..................... 57
(4) Troubleshooting procedure (If the air conditioner runs)
(3) Troubleshooting procedure
(If the air conditioner does not run at all)
........ 56
(2) Items to check before troubleshooting ................................................. 56
(5) Self-diagnosis table ............................................................................. 58
............................................................................... 56
(1) Cautions
............................................................................................. 56
10. MAINTENANCE DATA
-
4
-
'14 • SRK-T-154
1. SPECIFICATIONS
Model
Item
SRK20ZMA-S
Indoor unit SRK20ZMA-S Outdoor unit SRC20ZMA-S
Power source 1 Phase, 220 - 240V, 50Hz
Operation data
Nominal cooling capacity (range) kW 2.0 ( 1.0 (Min.) - 2.7 (Max.)) Nominal heating capacity (range) kW 2.7 ( 1.2 (Min.) - 3.9 (Max.)) Power consumption
Cooling
kW
0.44 ( 0.21 - 0.77 )
Heating 0.62 ( 0.27 - 1.38 ) Max power consumption 1.65 Running current
Cooling
A
2.5 / 2.4 / 2.3 (220/ 230/ 240 V)
Heating 3.2 / 3.1 / 3.0 (220/ 230/ 240 V) Inrush current, max current 3.2 / 3.1 / 3.0 (220/ 230/ 240 V) Max. 9
Power factor
Cooling
%
79.7
Heating 87 EER Cooling 4.55 COP Heating 4.35
Sound power level
Cooling
dB(A)
49 59
Heating 52 58
Sound pressure level
Cooling Hi: 33 Me: 27 Lo: 24 ULo: 21 47
Heating Hi: 36 Me: 31 Lo: 24 ULo: 21 46 Silent mode sound pressure level Cooling:42 / Heating:45
Exterior dimensions (Height x Width x Depth) mm 294 x 798 x 229 540 x 780(+62) x 290 Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent Net weight kg 9.5 31.5 Compressor type & Q'ty RM-B5077MDE1( Rotary type ) x 1 Compressor motor (Starting method) kW 0.75 ( Inverter driven ) Refrigerant oil (Amount, type) 0.35 (DIAMOND FREEZE MA68) Refrigerant (Type, amount, pre-charge length) kg R410A 0.75 in outdoor unit (incl. the amount for the piping of 15m ) Heat exchanger Louver fins & inner grooved tubing M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Fan type & Q'ty Tangential fan x 1 Propeller fan x 1 Fan motor (Starting method) W 30 x1 (Direct drive) 24 x1 (Direct drive)
Air flow
Cooling
m3/min
Hi: 7.8 Me: 5.6 Lo: 5.3 ULo: 4.8 29.5
Heating Hi: 9.8 Me: 6.3 Lo: 5.0 ULo: 4.5 25.6 Available external static pressure Pa 0 0 Outside air intake Not possible — Air filter, Quality / Quantity Polypropylene net ( washable ) x 2 — Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor) Electric heater
Operation control
Remote control Wireless remote control Room temperature control Microcomputer thermostat Operation display RUN: Green, TIMER: Yellow, HI POWER: Green, 3D AUTO: Green
Safety equipments
Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Indoor fan motor error protection, Heating overload protection (High pressure control), Cooling overload protection
Installation data
Refrigerant piping size (O.D) mm Liquid line :φ6.35 (1/4") Gas line :φ9.52 (3/8") Connecting method Flare connection Flare connection Attached length of piping m Liquid line : 0.53 / Gas line : 0.40 — Insulation for piping Necessary (Both sides), independent Refrigerant line (one way) length m Max. 15 Vertical height diff. between O.U. and I.U.
m Max. 10 (Outdoor unit is higher) / Max. 10 (Outdoor unit is lower)
Drain hose
Hose connectable ( VP 16 ) Holes φ20 x 2 pcs Drain pump, max lift height mm — Recommended breaker size A 16 L.R.A. (Locked rotor ampere) A 3.2 / 3.1 / 3.0 (220/ 230/ 240 V) Interconnecting wires Size x Core number 1.5mm2 x 4 cores (Including earth cable) / Terminal block (Screw fixing type) IP number IPX0 IPX4 Standard accessories
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Option parts Interface kit (SC-BIKN-E)
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C
ISO5151-T1
Heating 20˚C 7 ˚C 6 ˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher
due to ambient conditions. (4) Select the breaker size according to the own national standard. (5) This air-conditioner is compliant with DRED (AS / NZS 4755.3.1), and can operate with DRM1, 2 or 3 and is
equipped with a terminal block for DRED.
The pipe length is 7.5m.
B
RWA0 0 0 Z 253
-
5
-
'14 • SRK-T-154
Model
Item
SRK25ZMA-S
Indoor unit SRK25ZMA-S Outdoor unit SRC25ZMA-S
Power source 1 Phase, 220 - 240V, 50Hz
Operation data
Nominal cooling capacity (range) kW 2.5 ( 1.0 (Min.) - 2.9 (Max.)) Nominal heating capacity (range) kW 3.2 ( 1.2 (Min.) - 4.6 (Max.)) Power consumption
Cooling
kW
0.575 ( 0.21 - 0.81 )
Heating 0.70 ( 0.27 - 1.36 ) Max power consumption 1.65 Running current
Cooling
A
3.0 / 2.9 / 2.8 (220/ 230/ 240 V)
Heating 3.5 / 3.3 / 3.2 (220/ 230/ 240 V) Inrush current, max current 3.5 / 3.3 / 3.2 (220/ 230/ 240 V) Max. 9
Power factor
Cooling
%
87
Heating 91 EER Cooling 4.35 COP Heating 4.57
Sound power level
Cooling
dB(A)
49 58
Heating 55 59
Sound pressure level
Cooling Hi: 34 Me: 28 Lo: 24 ULo: 21 48
Heating Hi: 39 Me: 31 Lo: 24 ULo: 21 47 Silent mode sound pressure level Cooling:41 / Heating:42
Exterior dimensions (Height x Width x Depth) mm 294 x 798 x 229 595 x 780(+62) x 290 Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent Net weight kg 9.5 35 Compressor type & Q'ty RM-B5077MDE1( Rotary type ) x 1 Compressor motor (Starting method) kW 0.75 ( Inverter driven ) Refrigerant oil (Amount, type) 0.35 (DIAMOND FREEZE MA68) Refrigerant (Type, amount, pre-charge length) kg R410A 1.15 in outdoor unit (incl. the amount for the piping of 15m ) Heat exchanger Louver fins & inner grooved tubing M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Fan type & Q'ty Tangential fan x 1 Propeller fan x 1 Fan motor (Starting method) W 30 x1 (Direct drive) 24 x1 (Direct drive)
Air flow
Cooling
m3/min
Hi: 7.9 Me: 6.0 Lo: 5.3 ULo: 5.0 29.5
Heating Hi: 11.0 Me: 6.5 Lo: 5.1 ULo: 4.6 27.0 Available external static pressure Pa 0 0 Outside air intake Not possible — Air filter, Quality / Quantity Polypropylene net ( washable ) x 2 — Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor) Electric heater
Operation control
Remote control Wireless remote control Room temperature control Microcomputer thermostat Operation display RUN: Green, TIMER: Yellow, HI POWER: Green, 3D AUTO: Green
Safety equipments
Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Indoor fan motor error protection, Heating overload protection (High pressure control), Cooling overload protection
Installation data
Refrigerant piping size (O.D) mm Liquid line :φ6.35 (1/4") Gas line :φ9.52 (3/8") Connecting method Flare connection Flare connection Attached length of piping m Liquid line : 0.53 / Gas line : 0.40 — Insulation for piping Necessary (Both sides), independent Refrigerant line (one way) length m Max. 15 Vertical height diff. between O.U. and I.U.
m Max. 10 (Outdoor unit is higher) / Max. 10 (Outdoor unit is lower)
Drain hose
Hose connectable ( VP 16 ) Holes φ20 x 2 pcs Drain pump, max lift height mm — Recommended breaker size A 16 L.R.A. (Locked rotor ampere) A 3.5 / 3.3 / 3.2 (220/ 230/ 240 V) Interconnecting wires Size x Core number 1.5mm2 x 4 cores (Including earth cable) / Terminal block (Screw fixing type) IP number IPX0 IPX4 Standard accessories
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Option parts Interface kit (SC-BIKN-E)
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C
ISO5151-T1
Heating 20˚C 7 ˚C 6 ˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher
due to ambient conditions. (4) Select the breaker size according to the own national standard. (5) This air-conditioner is compliant with DRED (AS / NZS 4755.3.1), and can operate with DRM1, 2 or 3 and is
equipped with a terminal block for DRED.
The pipe length is 7.5m.
B
RWA0 0 0 Z 253
-
6
-
'14 • SRK-T-154
Model
Item
SRK35ZMA-S
Indoor unit SRK35ZMA-S Outdoor unit SRC35ZMA-S
Power source 1 Phase, 220 - 240V, 50Hz
Operation data
Nominal cooling capacity (range) kW 3.3 ( 1.0 (Min.) - 3.8 (Max.)) Nominal heating capacity (range) kW 4.0 ( 1.3 (Min.) - 4.8 (Max.)) Power consumption
Cooling
kW
0.87 ( 0.21 - 1.20 )
Heating 0.955 ( 0.29 - 1.45 ) Max power consumption 1.65 Running current
Cooling
A
4.3 / 4.1 / 3.9 (220/ 230/ 240 V)
Heating 4.6 / 4.4 / 4.2 (220/ 230/ 240 V) Inrush current, max current 4.6 / 4.4 / 4.2 (220/ 230/ 240 V) Max. 9
Power factor
Cooling
%
92
Heating 95 EER Cooling 3.79 COP Heating 4.19
Sound power level
Cooling
dB(A)
58 60
Heating 58 61
Sound pressure level
Cooling Hi: 45 Me: 32 Lo: 26 ULo: 22 50
Heating Hi: 42 Me: 37 Lo: 25 ULo:22 50 Silent mode sound pressure level Cooling:45 / Heating:43
Exterior dimensions (Height x Width x Depth) mm 294 x 798 x 229 595 x 780(+62) x 290 Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent Net weight kg 9.5 35 Compressor type & Q'ty RM-B5077MDE1( Rotary type ) x 1 Compressor motor (Starting method) kW 0.90 ( Inverter driven ) Refrigerant oil (Amount, type) 0.35 (DIAMOND FREEZE MA68) Refrigerant (Type, amount, pre-charge length) kg R410A 1.15 in outdoor unit (incl. the amount for the piping of 15m ) Heat exchanger Louver fins & inner grooved tubing M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Fan type & Q'ty Tangential fan x 1 Propeller fan x 1 Fan motor (Starting method) W 30 x1 (Direct drive) 24 x1 (Direct drive)
Air flow
Cooling
m3/min
Hi: 11.4 Me: 6.4 Lo: 5.4 ULo: 5.0 32.5
Heating Hi: 12.8 Me: 9.4 Lo: 6.1 ULo: 4.8 29.5 Available external static pressure Pa 0 0 Outside air intake Not possible — Air filter, Quality / Quantity Polypropylene net ( washable ) x 2 — Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor) Electric heater
Operation control
Remote control Wireless remote control Room temperature control Microcomputer thermostat Operation display RUN: Green, TIMER: Yellow, HI POWER: Green, 3D AUTO: Green
Safety equipments
Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Indoor fan motor error protection, Heating overload protection (High pressure control), Cooling overload protection
Installation data
Refrigerant piping size (O.D) mm Liquid line :φ6.35 (1/4") Gas line :φ9.52 (3/8") Connecting method Flare connection Flare connection Attached length of piping m Liquid line : 0.53 / Gas line : 0.40 — Insulation for piping Necessary (Both sides), independent Refrigerant line (one way) length m Max. 15 Vertical height diff. between O.U. and I.U.
m Max. 10 (Outdoor unit is higher) / Max. 10 (Outdoor unit is lower)
Drain hose
Hose connectable ( VP 16 ) Holes φ20 x 2 pcs Drain pump, max lift height mm — Recommended breaker size A 16 L.R.A. (Locked rotor ampere) A 4.6 / 4.4 / 4.2 (220/ 230/ 240 V) Interconnecting wires Size x Core number 1.5mm2 x 4 cores (Including earth cable) / Terminal block (Screw fixing type) IP number IPX0 IPX4 Standard accessories
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Option parts Interface kit (SC-BIKN-E)
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C
ISO5151-T1
Heating 20˚C 7 ˚C 6 ˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher
due to ambient conditions. (4) Select the breaker size according to the own national standard. (5) This air-conditioner is compliant with DRED (AS / NZS 4755.3.1), and can operate with DRM1, 2 or 3 and is
equipped with a terminal block for DRED.
The pipe length is 7.5m.
B
RWA0 0 0 Z 253
-
7
-
'14 • SRK-T-154
Model
Item
SRK50ZMA-S
Indoor unit SRK50ZMA-S Outdoor unit SRC50ZMA-S
Power source 1 Phase, 220 - 240V, 50Hz
Operation data
Nominal cooling capacity (range) kW 5.0 ( 1.6 (Min.) - 5.5 (Max.)) Nominal heating capacity (range) kW 5.8 ( 1.6 (Min.) - 6.6 (Max.)) Power consumption
Cooling
kW
1.55 ( 0.40 - 2.20 )
Heating 1.59 ( 0.42 - 2.10 ) Max power consumption 2.68 Running current
Cooling
A
7.1 / 6.8 / 6.5 (220/ 230/ 240 V)
Heating 7.3 / 7.0 / 6.7 (220/ 230/ 240 V) Inrush current, max current 7.3 / 7.0 / 6.7 (220/ 230/ 240 V) Max. 14
Power factor
Cooling
%
99
Heating 99 EER Cooling 3.23 COP Heating 3.65
Sound power level
Cooling
dB(A)
60 61
Heating 61 63
Sound pressure level
Cooling Hi: 46 Me: 37 Lo: 28 ULo: 25 51
Heating Hi: 45 Me: 37 Lo: 31 ULo:27 53 Silent mode sound pressure level Cooling:43 / Heating:45
Exterior dimensions (Height x Width x Depth) mm 294 x 798 x 229 640 x 800(+71) x 290 Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent Net weight kg 9.5 41 Compressor type & Q'ty 5RS132XAB21( Rotary type ) x 1 Compressor motor (Starting method) kW 1.50 ( Inverter driven ) Refrigerant oil (Amount, type) 0.37 ( FV50S ) Refrigerant (Type, amount, pre-charge length) kg R410A 1.35 in outdoor unit (incl. the amount for the piping of 15m ) Heat exchanger Louver fins & inner grooved tubing M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Fan type & Q'ty Tangential fan x 1 Propeller fan x 1 Fan motor (Starting method) W 30 x1 (Direct drive) 34 x1 (Direct drive)
Air flow
Cooling
m3/min
Hi: 11.3 Me: 7.8 Lo: 6.0 ULo: 5.3 36.0
Heating Hi: 13.5 Me: 10.2 Lo: 7.5 ULo: 6.2 36.0 Available external static pressure Pa 0 0 Outside air intake Not possible — Air filter, Quality / Quantity Polypropylene net ( washable ) x 2 — Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor) Electric heater
Operation control
Remote control Wireless remote control Room temperature control Microcomputer thermostat Operation display RUN: Green, TIMER: Yellow, HI POWER: Green, 3D AUTO: Green
Safety equipments
Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Indoor fan motor error protection, Heating overload protection (High pressure control), Cooling overload protection
Installation data
Refrigerant piping size (O.D) mm Liquid line :φ6.35 (1/4") Gas line :φ12.7 (1/2") Connecting method Flare connection Flare connection Attached length of piping m Liquid line : 0.53 / Gas line : 0.40 — Insulation for piping Necessary (Both sides), independent Refrigerant line (one way) length m Max. 25 Vertical height diff. between O.U. and I.U.
m Max. 15 (Outdoor unit is higher) / Max. 15 (Outdoor unit is lower)
Drain hose
Hose connectable ( VP 16 ) Holes φ20 x 5 pcs Drain pump, max lift height mm — Recommended breaker size A 16 L.R.A. (Locked rotor ampere) A 7.3 / 7.0 / 6.7 (220/ 230/ 240 V) Interconnecting wires Size x Core number 1.5mm2 x 4 cores (Including earth cable) / Terminal block (Screw fixing type) IP number IPX0 IPX4 Standard accessories
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Option parts Interface kit (SC-BIKN-E)
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C
ISO5151-T1
Heating 20˚C 7 ˚C 6 ˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher
due to ambient conditions. (4) Select the breaker size according to the own national standard. (5) This air-conditioner is compliant with DRED (AS / NZS 4755.3.1), and can operate with DRM1, 2 or 3 and is
equipped with a terminal block for DRED.
The pipe length is 7.5m.
B
RWA0 0 0 Z 253
-
8
-
'14 • SRK-T-154
2. EXTERIOR DIMENSIONS
(1) Indoor units
Models SRK20ZMA-S, 25ZMA-S, 35ZMA-S, 50ZMA-S
RLA000Z053
Unit:mm
Space for installation and service when viewing from the front
120
19
Wired - remote control
Option
Notes(1)The model name label is attached
     on the underside of the panel.
2It takes the interface kit (SC-BIKN-E
     to connect the wired remote control.
G
790
6014.5
45
3160
45
798
294
229 3
45
609
100106.5585106.5
50
48.9
55
47
47
55
403.6
471.6
531.8
F
Outlet for down piping
Refer to the above view
139 450 209
Unit
D
C
A
E
B
65
15
7.7279.17.2
Service space
Service space
Service space
Service space
Hole on wall for right rear piping
Hole on wall for left rear piping
Gas piping
Outlet for wiring
Drain hose
Liquid piping
F
ECD
B
Symbol
A
φ
65
VP16
φ
6.35(1/4")(Flare)
Content
φ
65
2035 :
φ
9.52(3/8")(Flare)
Outlet for piping(on both side)
G
50
:
φ
12.7(1/2")(Flare)
Model
Installation plate
Wireless remote control
60 24
167
-
9
-
'14 • SRK-T-154
(2) Outdoor units
Models SRC20ZMA-S
RCV000Z017
φ9.52(38")(Flare
Content
C Pipecable draw-out hole
D
E Anchor bolt hole
Drain discharge hole
Symbol
B
A Service valve connection(gas side)
M10×4places
φ20×2places
Service valve connection(liquid side)
φ6.35(14")(Flare
Unit:mm
L2
Intake
Outlet
Intake
L3
L1
Minimum installation space
Service
space
( )
Notes
(1) It must not be surrounded by walls on the four sides.
 (2 The unit must be fixed with anchor bolts. An anchor bolt must not
protrude more than 15mm.
 (3 Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces perpendicularly
to the dominant wind direction.
 (4 Leave 1m or more space above the unit.
 (5 A wall in front of the blower outlet must not exceed the units height.
 (6 The model name label is attached on the right side of the unit.
L4
L2
L3
L4
L1
100
100
250
Open
II
Open
250
80
280
III
280
Open
80
75
Examples of
Dimensions
installation
IV
180
Open
80
Open
63.4
390.6
390.6
69.4
111.6 510 158.4
780 61.9
17.9
14.8 312.5 24.3
351.6
50.6
12
97.7 42.5
40
°
40
°
138.4 33.5
15.8
290
A
C
B
D
E
540
Terminal block
Terminal block
For DRED ASNZS 4755
-
10
-
'14 • SRK-T-154
Models SRC25ZMA-S, 35ZMA-S
RCV000Z018
φ9.52(38")(Flare
Content
C Pipecable draw-out hole
E Anchor bolt hole
Drain discharge hole
Symbol
B
A Service valve connection(gas side)
M10×4places
φ20×2places
Service valve connection(liquid side)
φ6.35(14")(Flare
Unit:mm
L2
Intake
Outlet
Intake
L3
L1
Minimum installation space
Service
space
( )
Notes
1) It must not be surrounded by walls on the four sides.
 (2 The unit must be fixed with anchor bolts. An anchor bolt must not
protrude more than 15mm.
 (3 Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces perpendicularly
to the dominant wind direction.
 (4 Leave 1m or more space above the unit.
 (5 A wall in front of the blower outlet must not exceed the units height.
 (6 The model name label is attached on the lower right corner of the front panel.
L4
L2
L3
L4
L1
100
100
250
Open
II
Open
250
80
280
III
280
Open
80
75
Examples of
Dimensions
installation
IV
180
Open
80
Open
63.4
390.6
390.6
69.4
111.6 510 158.4
780 61.9
17.9
14.8 312.5 24.3
351.6
50.6
12
97.7 42.5
40
°
40
°
138.4 33.5
15.8
290
A
C
B
E
595
D
D
Terminal block
Terminal block
For DRED ASNZS 4755
-
11
-
'14 • SRK-T-154
Models SRC50ZMA-S
RCT000Z007
φ12.7(12")(Flare
Content
C Pipecable draw-out hole
D
E Anchor bolt hole
Drain discharge hole
Symbol
B
A Service valve connection(gas side)
M10×4places
φ20×5places
Service valve connection(liquid side)
φ6.35(14")(Flare
Unit:mm
L2
Intake
Outlet
Intake
L3
L1
A
C
93 42.5
640
800
89 510 201
327.3
83.5
290
43.5
327.3 50.6
12
24.3312.514.8
71.2
17.9
40°
40°
33.5148.4
12.4
D
Minimum installation space
B
E
Service
space
( )
Notes
(1) It must not be surrounded by walls on the four sides.
 (2 The unit must be fixed with anchor bolts. An anchor bolt must not
protrude more than 15mm.
 (3 Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces perpendicularly
to the dominant wind direction.
 (4 Leave 1m or more space above the unit.
 (5 A wall in front of the blower outlet must not exceed the units height.
 (6 The model name label is attached on the right side of the unit.
351.6
L4
L2
L3
L4
L1
100
100
250
Open
II
Open
250
80
280
III
280
Open
80
75
Examples of
Dimensions
installation
IV
180
Open
80
Open
38.6
90.6
520.6 161
35.6
Terminal block
Terminal block
For DRED ASNZS 4755
-
12
-
'14 • SRK-T-154
(3) Remote control
Unit : mm
60
26
167
(a) Wireless remote control
-
13
-
'14 • SRK-T-154
(b) Wired remote control (option parts)
Interface kit (SC-BIKN-E) is required to use the wired remote control.
PJZ0 0 0 Z 295
TEMP ON/OFF
48
120
L C D
Wall surface
Wiring
Electrical box
Not included
19
Wiring specifications
Exposed mounting
23
46
11.5 11
Remote control outline
120
45
83.5
42
120
Remote control installation dimensions
Wiring oulet
Installation hole
12×7 Slot hole
9.5×5 Slot hole 4places
1 Installation screw for remote control
M4 Screw (2 pieces)
44
(1) If the prolongation is over 100m, change to the size below. But, wiring in the remote control case should be under 0.5mm2. Change the wire size outside of the case according to wire connecting. Waterproof treatment is necessary at the wire connecting section. Be careful about contact failure.
Length Wiring thickness
100 to 200m
0.5mm2×2 cores
0.75mm2×2 cores
1.25mm2×2 cores
2.0mm2×2 cores
Under 300m
Under 400m
Under 600m
Upper part
Lower part
Lower case
Sheath
Upper cace
Board
Wiring
Upper
Lower
X Y
Sheath
Upper cace
Board
Wiring
Upper
Lower
YX
Tighten the screws after cutting off the thin part of screw mounting part.
Embedded mounting
Pearl WhiteExterior appearance
(Munsell color) (N8.5) near equivalent
The peeling-off length of sheath
The peeling-off length
of sheath
In case of pulling out from
upper left
In case of pulling out from upper left
In case of pulling out from upper left
X wiring : 170mm Y wiring : 190mm
Pulling out from center
X wiring : 215mm Y wiring : 195mm
Pulling out from upper left
In case of pulling out from center
In case of pulling out from center
In case of pulling out from center
Wiring outlet Cut off the upper thin part of remote control lower case with a nipper or knife, and grind burrs with a file etc.
0.3mm2×2 cores.
X, Y Terminal block Attach M3 screw
with washer
Unit:mm
-
14
-
'14 • SRK-T-154
Blue
BlackBK
Red
BL
RD
WhiteWH
YellowGreenYG
ColorMark
Heat exch. sensor
Fan motor
Room temp. sensor
Flap motor
Diode stackDS
FuseF
Connector
CNE-CNY
FM
I
Terminal blockT
Description
Item
VaristorVa
250V 3.15A
PRINTED
CNF CNE
CNX
CNG
4
CNU
1 3 65
35,50
CNY
M M M
5 5
U
2 8
2
t
o
CNS
CNM
M
5
TO OUTDOOR
SN
J
L
G
1
CIRCUIT
BOARD
INTERFACE KIT
RD
BK
WH
Y
BL
WIRELESS
DISPLAY
BACK-UP SW
UNIT
BK
WH
RD
YG
HEAT
EXCHANGER
2N
3
YG
HD
ONLY
t
o
2
t
o
R-AMP
2
HEAT
EXCHANGER
5
FM
I
SM
I
LM
1
LM
2
F
Va
Th
I
Th
2
Th
3
T
DS
LM
1,2
SM
I
Louver motor
Th
ITh2,3
YellowY
Humidity sensor
HD
Power Source
1 Phase
220230240V 50Hz
RWA000Z255
3. ELECTRICAL WIRING
(1) Indoor units
Models SRK20ZMA-S, 25ZMA-S, 35ZMA-S, 50ZMA-S
-
15
-
'14 • SRK-T-154
RWC0 0 0 Z 271
(2) Outdoor units
Models SRC20ZMA-S, 25ZMA-S, 35ZMA-S
20
Model
Power cable, indoor-outdoor connecting wires
MAX running current
Power cable size
mm
2
A
Power cable length
m
indoor-outdoor
wire size x number
Earth wire size
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
25
9(ZMA)
2.0 32
1.5mm x 3 1.5
35
Color
RD
Mark
OrangeOR
YellowGreen
YG
BlackBK
YellowY
WhiteWH
Red
DescriptionItem
Connector
Electric expansion valve(coil)EEV
Fan motor
FMo
ReactorLTerminal blockTB1,2
Compressor motor
CM
Solenoid valve for 4 way valve20S
Heat exchanger sensor(outdoor unit)TH2
Outdoor air temp.sensorTH3
TH4 Discharge pipe temp.sensor
CN20S
CNTH
CNEEV
CNFAN
2
CM
BK
C-2
G1
RD
YG
S.IN
WH
R.IN
BK
WH
RD
PWB ASSY PWB1
250V 20A
F2
F3 250V 1A
F4
250V 10A
20S
CIRCUIT
PAM
N
P
WVU
TRANSISTOR
POWER
WVU
FILTER
NOISE
CNTH
CNEEV
CNFAN
M
250V 15A
L
YG
N
TB1
132
T1
T2
F1
250V 3.15A
CIRCUIT
POWER
SWITCHING
CNDRM
CNDRM
CNPOWER
CNDRED
PWB ASSY
BK
WH
YE
RD
BL
BK
YG
G2
YG
BK
2 2 2
TH2 TH3 TH4
EEV
2
4
FMo
TERMINAL
BLOCK
M
3
M
PWB2
++
D1
TB2
TERMINAL
BLOCK
D2
D3
C
t
t
t
t
t
CN20S
H
CNHEAT
F6
250V 1A
2
3
1
2
[ ]
TO INDOOR UNIT
POWER WIRES
SIGNAL WIRE
N
220240V 50Hz/〜220V 60Hz
POWER SOURCE
8(ZMXA)
OR) (Y
L
mm
2
-
16
-
'14 • SRK-T-154
RWC0 0 0 Z 267
Models SRC50ZMA-S
Color
RD
Mark
OrangeOR
YellowGreen
YG
BlackBK
BrownBR
YellowYE
WhiteWH
Red
Model
Power cable, indoor-outdoor connecting wires
MAX running current
Power cable size
mm
2
A
Power cable length
m
indoor-outdoor
wire size x number
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
DescriptionItem
14
2.0
18
1.5mm x 3 1.5
Connector
CNEEVCN20S
Electric expansion valve(coil)
EEV
Fan motorFMo
ReactorR
Terminal block
TB1,2,3
Compressor motor
CM
Solenoid valve for 4 way valve
20S
Heat exchanger sensor(outdoor unit)
TH2
Outdoor air temp.sensor
TH3
TH4
Discharge pipe temp.sensor
3
1
2
[ ]
TO INDOOR UNIT
POWER WIRES
SIGNAL WIRE
N
50
2
T2
T1
S
BK
WH
RD
VWU
PWB ASSYMAIN
M
+ +
R
TRANSISTOR
POWER
CIRCUIT
SWITCHING
250V 3.15A
F1
250V 20A
F2
F3 250V 1A
WVU
P
N
CNTH
CNEEV
CNFAN
t
+
ACTIVE
FILTER
UNIT
250V 20A
F8
R
OR
YE
S-2
BK
WH
WH
BK
PWB ASSYSUB
S-1
CNSUB
CNMAIN
S
R
R
BK
WH
G1YG
BR
IN
IN
OUT
S
R
O
O
N
L
250V 20A
FUSE
2
1N3
YG
YG
CN20S
C-2
RD
20S
TB1
TB2
TERMINAL
BLOCK
2 2 2
TH2 TH3 TH4
FMo
BLOCK
TERMINAL
WH
t
t
POWER
YG
G3
D1D3D2
C
TB3
BLOCK
TERMINAL
4
YE
RD
BL
BK
YG
4
WH
BK
PWB ASSY(DRED)
CNPOWER
CNDRED
CNDRM
BK
CNDRM
MS
CM
3
250V 10A
F10
2
M
EEV
BlueBL
POWER SOURCE
220-240V 50Hz
Earth wire size
mm
2
-
17
-
'14 • SRK-T-154
'09•SRK-DB-087D
(Indoor Unit) Model SRK20ZMA-S
Noise
Level
Cooling 33 dB(A)
Heating 36 dB(A)
×
......
Cooling  Heating
(Outdoor Unit) Model SRC20ZMA-S
Noise
Level
Cooling 47 dB(A)
Heating 46 dB(A)
×
......
Cooling  Heating
Condition ISO-T1, JIS C 9612
63
10
20
30
40
50
60
70
125 250 500 1000 2000 4000 8000
1000 2000 4000 8000
10
20
30
40
50
60
70
N50
N30
N40
N60
N70
N20
10
20
30
40
50
60
70
63 125 250 500
10
20
30
40
50
60
70
N50
N40
N60
N70
N20
N30
Sound Pressure Level (dB)
(standard 2×10
-5
Pa)
Mid Octave Band frequency (Hz)
Sound Pressure Level (dB)
(standard 2×10
-5
Pa)
Mid Octave Band frequency (Hz)
4. NOISE LEVEL
Model SRK20ZMA-S
Mike position
0.8m
1m
Unit
Mike position (Center & Low points)
Mike position: at highest noise level in position as mentioned below Distance from front side 1m
Mike position
0.8m
1m
Unit
Mike position (Center & Low points)
-
18
-
'14 • SRK-T-154
'09•SRK-DB-087D
(Indoor Unit) Model SRK25ZMA-S
Noise
Level
Cooling 34 dB(A)
Heating 39 dB(A)
×
......
Cooling  Heating
Model SRK25ZJ-S
(Outdoor Unit) Model SRC25ZMA-S
Noise
Level
Cooling 48 dB(A)
Heating 47 dB(A)
×
......
Cooling Heating
Condition ISO-T1, JIS C 9612
10
20
30
40
50
60
70
63 125 250 500 1000 2000 4000 8000
1000 2000 4000 8000
10
20
30
40
50
60
70
N50
N30
N40
N60
N70
N20
10
20
30
40
50
60
70
63 125 250 500
10
20
30
40
50
60
70
Sound Pressure Level (dB)
(standard 2×10
-5
Pa)
Sound Pressure Level (dB)
(standard 2×10
-5
Pa)
Mid Octave Band frequency (Hz)
Mid Octave Band frequency (Hz)
N50
N30
N40
N60
N70
N20
Model SRK25ZMA-S
Mike position
0.8m
1m
Unit
Mike position (Center & Low points)
Mike position: at highest noise level in position as mentioned below Distance from front side 1m
Mike position
0.8m
1m
Unit
Mike position (Center & Low points)
-
19
-
'14 • SRK-T-154
'09•SRK-DB-087D
(Indoor Unit) Model SRK35ZMA-S
Noise
Level
Cooling
45 dB(A)
Heating
42 dB(A)
×
......
Cooling  Heating
(Outdoor Unit) Model SRC35ZMA-S
Noise
Level
Cooling
50 dB(A)
Heating
50 dB(A)
×
......
Cooling  Heating
Condition ISO-T1, JIS C 9612
10
20
30
40
50
60
70
63 125 250 500 1000 2000 4000 8000
63 125 250 500 1000 2000 4000 8000
10
20
30
40
50
60
70
N50
N30
N40
N60
N70
N20
10
20
30
40
50
60
70
10
20
30
40
50
60
70
N50
N30
N40
N60
N70
N20
Sound Pressure Level (dB)
(standard 2×10
-5
Pa)
Sound Pressure Level (dB)
(standard 2×10
-5
Pa)
Mid Octave Band frequency (Hz)
Mid Octave Band frequency (Hz)
Model SRK35ZMA-S
Mike position
0.8m
1m
Unit
Mike position (Center & Low points)
Mike position: at highest noise level in position as mentioned below Distance from front side 1m
Mike position
0.8m
1m
Unit
Mike position (Center & Low points)
-
20
-
'14 • SRK-T-154
N50
N30
N40
N60
N70
N20
Sound Pressure Level (dB)
(standard 2×10
-5
Pa)
Mid Octave Band frequency (Hz)
10
20
30
40
50
60
70
10
20
30
40
50
60
70
63 125 250 500 1000 2000 4000 8000
N50
N30
N40
N60
N70
N20
Sound Pressure Level (dB)
(standard 2×10
-
5
P
a
)
Mid Octave Band frequency (Hz)
10
20
30
40
50
60
70
10
20
30
40
50
60
70
63
125
250
500
1000
2000
4000
8000
(Indoor Unit)
Model SRK50ZMA-S
Noise Level
Cooling 46 dB(A)
Heating 45 dB(A)
×
......
Cooling Heating
Model SRK50ZMA-S
(Outdoor Unit)
Model SRC50ZMA-S
Noise Level
Cooling 51 dB(A)
Heating 53 dB(A)
×
......
Cooling Heating
Condition ISO-T1,JIS C 9612
Mike position: at highest noise level in position as mentioned below Distance from front side 1m
Mike position
0.8m
1m
Unit
Mike position (Center & Low points)
Mike position
0.8m
1m
Unit
Mike position (Center & Low points)
-
21
-
'14 • SRK-T-154
'09•SRK-DB-087D
5 PIPING SYSTEM
Models SRK20ZMA-S, 25ZMA-S
Model SRK35ZMA-S
Humidity sensor
(HD)
pipe
pipe
5. PIPING SYSTEM
-
22
-
'14 • SRK-T-154
Model SRK50ZM-S
Indoor unit
Outdoor unit
Flare connection
Flare connection
Liquid pipe
(φ6.35)
Gas
pipe
(φ12.7)
Service valve
Heat exchanger
Heat exchanger sensor
Electronic expansion valve
(Liquid)
Strainer
Receiver
Muffler
Capillary tube
Outdoor air temp. sensor
Muffler
Muffler
Compressor
Discharge pipe temp. sensor
Cooling cycle
Heating cycle
Check joint
4way valve
Service valve
Heat exchanger sensor
(Th3)
(TH3)
Room temp. sensor
(Th1)
(Th2)
(
Gas
)
(TH2)
Heat exchanger sensor
(TH1)
(EEV)
Capillary tube
Heat exchanger
Humidity sensor
(HD)
Model SRK50ZMA-S
-
23
-
'14 • SRK-T-154
RANGE OF USAGE & LIMITATIONS
Indoor return air temperature (Upper, lower limits)
Refrigerant line (one way) length
Power source voltage Rating ±10%
Voltage at starting Min. 85% of rating
Frequency of ON-OFF cycle
Max. 4 times/h
(Inching prevention 10 minutes)
Max. 7 times/h
(Inching prevention 5 minutes)
ON and OFF interval Min. 3 minutes
Outdoor air temperature (Upper, lower limits)
Vertical height difference between outdoor unit and indoor unit
Max. 15m Max. 25m
Max. 10m
(Outdoor unit is higher)
Max. 10m
(Outdoor unit is lower)
Max. 15m
(Outdoor unit is higher)
Max. 15m
(Outdoor unit is lower)
Item
Models
SRK20,25,35ZMA-S SRK50ZMA-S
Cooling operation : Approximately 18 to 32 D.B. Heating operation : Approximately 10 to 30 D.B. (Refer to the selection chart)
Cooling operation : Approximately -15 to 46 D.B. Heating operation : Approximately -15 to 24 D.B. (Refer to the selection chart)
Selection chart
Correct the cooling and heating capacity in accordance with the conditions as follows. The net cooling and heating capacity can be obtained in the following way.
Net capacity = Capacity shown on specification ×Correction factors as follows.
(1) Coefficient of cooling and heating capacity in relation to temperatures
0.6
0.7
0.8
0.9
1.0
1.2
1.1
1.3
0
-5
-10
-15
24
26
20
25
30
35
40
46
10
15
20
25
27
Outdoor air W.B. temperature °C W.B.
-15 -10 -5 0 5 10 15
.
Cooling operation
Outdoor air D.B.
temperature
°C D. B.
Coefficient of cooling
&
heating capacity in
relation to temperature
Heating operation
Indoor air D.B.
temperature
°C D. B.
ISO-T1 Standard Condition
Depends on installed situation
ISO-T1 Standard Condition
2220181614
Indoor air W.B. temperature °C W.B
Applicable range
Cooling
Heating
6. RANGE OF USAGE & LIMITATIONS
-
24
-
'14 • SRK-T-154
'09•SRK-DB-087D
(2) Correction of cooling and heating capacity in relation to one way length of refrigerant piping
(3) Correction relative to frosting on outdoor heat exchanger during heating
How to obtain the cooling and heating capacity
=
Piping length [m]
Cooling
Heating
7
1.0
1.0
10
0.99
1.0
15
0.975
1.0
20
0.965
1.0
25
0.95
1.0
30
0.935
1.0
Air inlet temperature of
outdoor unit in °C WB
Adjustment coefficient
-15
0.95 0.95 0.94 0.93 0.91 0.88 0.86 0.87 0.92 1.00
-10 -9 -7 -5 -3 -1 1 3
5 or more
A
A
-
25
-
'14 • SRK-T-154
Heating Mode (HC) (kW)
Heating Mode (HC) (kW)(kW)
(kW)
(kW)
Air flow
outdoor
air temp.
Indoor air temp
16˚CDB 18˚CDB 20˚CDB 22˚CDB 24˚CDB
Hi
9.8
(m3/min)
-15˚CWB 1.66 1.63 1.59 1.55 1.52
-10˚CWB 1.88 1.85 1.82 1.78 1.74
-5˚CWB 2.04 2.01 1.97 1.94 1.91
0˚CWB 2.13 2.10 2.07 2.04 2.01
5˚CWB 2.72 2.69 2.67 2.62 2.58
6˚CWB 2.76 2.73 2.70 2.67 2.63
10˚CWB 2.94 2.91 2.89 2.85 2.82
15˚CWB 3.20 3.17 3.14 3.11 3.08
20˚CWB 3.43 3.41 3.39 3.35 3.32
Heating Mode (HC) (kW)
Air flow
Outdoor
air temp.
Indoor air temp
21˚CDB 23˚CDB 26˚CDB 27˚CDB 28˚CDB 31˚CDB 33˚CDB
14˚CWB 16˚CWB 18˚CWB 19˚CWB 20˚CWB 22˚CWB 24˚CWB
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
Hi
7.9
(m3/min)
10
2.82 2.23 2.95 2.19 3.06 2.27 3.11 2.24 3.16 2.21 3.26 2.28 3.34 2.21
12 2.77 2.20 2.90 2.17 3.01 2.25 3.07 2.22 3.12 2.20 3.22 2.27 3.31 2.20
14 2.71 2.17 2.85 2.14 2.97 2.23 3.03 2.21 3.08 2.18 3.18 2.25 3.28 2.19
16 2.66 2.15 2.80 2.12 2.92 2.21 2.98 2.19 3.04 2.16 3.15 2.24 3.24 2.18
18 2.60 2.12 2.74 2.09 2.88 2.19 2.94 2.17 2.99 2.14 3.11 2.22 3.20 2.17
20 2.55 2.09 2.68 2.07 2.83 2.17 2.89 2.14 2.95 2.12 3.07 2.21 3.17 2.15
22 2.49 2.06 2.63 2.04 2.78 2.14 2.84 2.12 2.90 2.10 3.02 2.20 3.13 2.14
24 2.43 2.03 2.57 2.01 2.72 2.12 2.80 2.11 2.85 2.08 2.98 2.18 3.08 2.13
26 2.37 2.00 2.51 1.98 2.67 2.10 2.74 2.09 2.80 2.07 2.93 2.16 3.04 2.11
28 2.31 1.97 2.44 1.96 2.61 2.08 2.69 2.07 2.75 2.05 2.89 2.14 3.00 2.10
30 2.24 1.94 2.38 1.92 2.56 2.05 2.64 2.05 2.70 2.03 2.84 2.13 2.95 2.08
32 2.18 1.91 2.31 1.89 2.50 2.03 2.58 2.03 2.64 2.01 2.79 2.11 2.90 2.07
34 2.11 1.88 2.25 1.87 2.44 2.01 2.53 2.00 2.59 1.99 2.74 2.09 2.85 2.05
35 2.08 1.87 2.21 1.85 2.41 1.99 2.50 1.99 2.56 1.97 2.71 2.08 2.83 2.04
36 2.04 1.85 2.18 1.84 2.38 1.98 2.47 1.98 2.53 1.96 2.69 2.08 2.80 2.03
38 1.97 1.82 2.11 1.81 2.32 1.96 2.41 1.96 2.47 1.94 2.63 2.05 2.75 2.02
39 1.94 1.80 2.07 1.79 2.28 1.94 2.38 1.94 2.44 1.93 2.61 2.05 2.72 2.01
Model SRK25ZMA-S
Cooling Mode
Air flow
outdoor
air temp.
indoor air temp
16˚CDB 18˚CDB 20˚CDB 22˚CDB 24˚CDB
Hi
11.0
(m3/min)
-15˚CWB 1.97 1.93 1.88 1.84 1.80
-10˚CWB 2.23 2.19 2.16 2.10 2.06
-5˚CWB 2.41 2.38 2.33 2.30 2.27
0˚CWB 2.53 2.49 2.45 2.42 2.38
5˚CWB 3.22 3.19 3.17 3.10 3.06
6˚CWB 3.27 3.24 3.20 3.16 3.12
10˚CWB 3.48 3.45 3.42 3.38 3.34
15˚CWB 3.79 3.75 3.73 3.69 3.65
20˚CWB 4.07 4.04 4.02 3.97 3.94
Air flow
outdoor
air temp.
indoor air temp
16˚CDB 18˚CDB 20˚CDB 22˚CDB 24˚CDB
Hi
12.8
(m3/min)
-15˚CWB 2.46 2.41 2.35 2.30 2.25
-10˚CWB 2.79 2.74 2.70 2.63 2.58
-5˚CWB 3.02 2.97 2.91 2.88 2.83
0˚CWB 3.16 3.12 3.06 3.02 2.98
5˚CWB 4.03 3.98 3.96 3.88 3.83
6˚CWB 4.09 4.04 4.00 3.95 3.90
10˚CWB 4.35 4.31 4.28 4.22 4.18
15˚CWB 4.73 4.69 4.66 4.61 4.56
20˚CWB
5.09 5.05 5.02 4.96 4.92
Air flow
Outdoor
air temp.
Indoor air temp
21˚CDB 23˚CDB 26˚CDB 27˚CDB 28˚CDB 31˚CDB 33˚CDB
14˚CWB 16˚CWB 18˚CWB 19˚CWB 20˚CWB 22˚CWB 24˚CWB
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
Hi
11.4
(m3/min)
10
12
14
16
18
20
22
24
26
28
30
32
34
35
36
38
39
Model SRK35ZMA-S
Cooling Mode
3.72
3.65
3.58
3.51
3.44
3.36
3.29
3.21
3.13
3.04
2.96
2.87
2.79
2.74
2.69
2.60
2.56
3.01
2.98
2.95
2.90
2.87
2.84
2.80
2.76
2.72
2.69
2.64
2.60
2.56
2.54
2.52
2.48
2.45
3.89
3.83
3.76
3.69
3.62
3.54
3.47
3.39
3.31
3.23
3.14
3.05
2.96
2.92
2.87
2.78
2.73
2.96
2.93
2.90
2.86
2.83
2.80
2.77
2.73
2.70
2.66
2.62
2.58
2.54
2.52
2.51
2.46
2.45
4.04
3.98
3.92
3.86
3.80
3.73
3.66
3.59
3.52
3.45
3.38
3.30
3.22
3.18
3.14
3.06
3.01
3.09
3.06
3.04
3.01
2.98
2.95
2.92
2.90
2.86
2.84
2.80
2.77
2.74
2.71
2.70
2.67
2.65
4.10
4.05
3.99
3.94
3.88
3.82
3.75
3.69
3.62
3.55
3.48
3.41
3.34
3.30
3.26
3.18
3.14
3.04
3.02
3.00
2.98
2.95
2.93
2.90
2.87
2.85
2.82
2.80
2.76
2.74
2.72
2.69
2.66
2.65
4.17
4.12
4.07
4.01
3.95
3.89
3.83
3.77
3.70
3.63
3.56
3.49
3.42
3.38
3.34
3.26
3.22
3.01
2.99
2.96
2.94
2.92
2.90
2.87
2.85
2.82
2.79
2.77
2.74
2.71
2.68
2.67
2.64
2.63
4.30
4.25
4.20
4.15
4.10
4.05
3.99
3.93
3.87
3.81
3.75
3.68
3.62
3.58
3.55
3.48
3.44
3.11
3.08
3.06
3.05
3.03
3.01
3.00
2.98
2.96
2.93
2.91
2.89
2.87
2.85
2.84
2.81
2.80
4.41
4.37
4.33
4.28
4.23
4.18
4.13
4.07
4.02
3.96
3.90
3.83
3.77
3.73
3.70
3.63
3.60
3.01
3.00
2.98
2.97
2.96
2.94
2.93
2.91
2.89
2.87
2.85
2.83
2.81
2.80
2.78
2.77
2.76
7. CAPACITY TABLES
Air flow
Outdoor air temp.
Indoor air temp
21˚CDB 23˚CDB 26˚CDB 27˚CDB 28˚CDB 31˚CDB 33˚CDB
14˚CWB 16˚CWB 18˚CWB 19˚CWB 20˚CWB 22˚CWB 24˚CWB
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
Hi
7.8
(m3/min)
10 2.25 1.93 2.36 1.90 2.45 1.99 2.49 1.96 2.53 1.94 2.60 2.02 2.67 1.97
12 2.21 1.91 2.32 1.88 2.41 1.97 2.45 1.95 2.50 1.93 2.58 2.01 2.65 1.96
14 2.17 1.89 2.28 1.86 2.38 1.96 2.42 1.94 2.47 1.91 2.55 2.00 2.62 1.95
16 2.13 1.87 2.24 1.85 2.34 1.94 2.39 1.92 2.43 1.90 2.52 1.99 2.59 1.94
18 2.08 1.85 2.19 1.82 2.30 1.92 2.35 1.90 2.40 1.88 2.49 1.98 2.56 1.93
20 2.04 1.83 2.15 1.81 2.26 1.91 2.31 1.89 2.36 1.87 2.45 1.97 2.53 1.92
22 1.99 1.81 2.10 1.78 2.22 1.89 2.28 1.88 2.32 1.86 2.42 1.95 2.50 1.91
24 1.94 1.78 2.05 1.76 2.18 1.88 2.24 1.86 2.28 1.85 2.38 1.94 2.47 1.90
26 1.90 1.76 2.01 1.74 2.14 1.86 2.20 1.85 2.24 1.83 2.35 1.93 2.43 1.89
28 1.85 1.74 1.96 1.72 2.09 1.84 2.15 1.83 2.20 1.82 2.31 1.92 2.40 1.88
30 1.79 1.70 1.90 1.70 2.05 1.83 2.11 1.82 2.16 1.80 2.27 1.90 2.36 1.87
32 1.74 1.65 1.85 1.68 2.00 1.81 2.07 1.80 2.12 1.79 2.23 1.89 2.32 1.86
34 1.69 1.60 1.80 1.65 1.95 1.79 2.02 1.78 2.07 1.77 2.19 1.88 2.28 1.85
35 1.66 1.58 1.77 1.64 1.93 1.78 2.00 1.78 2.05 1.76 2.17 1.87 2.26 1.84
36 1.63 1.55 1.74 1.62 1.90 1.77 1.98 1.77 2.02 1.75 2.15 1.87 2.24 1.83
38 1.58 1.50 1.68 1.60 1.85 1.75 1.93 1.75 1.98 1.74 2.11 1.85 2.20 1.82
39 1.55 1.47 1.66 1.57 1.83 1.74 1.91 1.74 1.95 1.73 2.08 1.84 2.18 1.81
Model SRK20ZMA-S
Cooling Mode
Note(1) These data show average statuses.
Depending on the system control, there may be ranges where the operation is not conducted continuously. These data show the case where the operation frequency of a compressor is fixed.
(2) Capacities are based on the following conditions.
Corresponding refrigerant piping length :7m Level difference of Zero.
(3) Symbols are as follows.
TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) HC : Heating capacity (kW)
-
26
-
'14 • SRK-T-154
Air flow
outdoor
air temp.
indoor air temp
16˚CDB 18˚CDB 20˚CDB 22˚CDB 24˚CDB
Hi
13.5
(m3/min)
-15˚CWB 3.57 3.49 3.41 3.34 3.26
-10˚CWB 4.04 3.97 3.91 3.81 3.73
-5˚CWB 4.37 4.31 4.22 4.18 4.11
0˚CWB 4.59 4.52 4.44 4.39 4.32
5˚CWB 5.84 5.77 5.74 5.63 5.55
6˚CWB
5.94 5.87 5.80 5.73 5.66
10˚CWB
6.31 6.25 6.21 6.12 6.06
15˚CWB 6.86 6.80 6.76 6.68 6.62
20˚CWB
7.38 7.32 7.28 7.20 7.14
Model SRK50ZMA-S
Cooling Mode
Air flow
Outdoor air temp.
Indoor air temp
21˚CDB 23˚CDB 26˚CDB 27˚CDB 28˚CDB 31˚CDB 33˚CDB
14˚CWB 16˚CWB 18˚CWB 19˚CWB 20˚CWB 22˚CWB 24˚CWB
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
Hi
11.3
(m3/min)
10 5.63 4.09 5.90 4.02 6.11 4.12 6.22 4.05 6.32 3.99 6.51 4.05 6.69 3.92
12 5.53 4.03 5.80 3.97 6.03 4.07 6.14 4.01 6.25 3.96 6.44 4.02 6.62 3.89
14 5.43 3.98 5.70 3.91 5.94 4.03 6.05 3.98 6.16 3.92 6.37 4.00 6.55 3.86
16 5.32 3.92 5.59 3.86 5.85 3.98 5.96 3.93 6.08 3.88 6.29 3.96 6.48 3.84
18 5.21 3.85 5.48 3.80 5.75 3.94 5.88 3.90 5.99 3.84 6.21 3.93 6.41 3.81
20 5.10 3.79 5.37 3.74 5.65 3.89 5.78 3.85 5.90 3.80 6.13 3.90 6.33 3.78
22 4.98 3.73 5.25 3.68 5.55 3.84 5.69 3.81 5.80 3.76 6.05 3.86 6.25 3.75
24 4.86 3.67 5.14 3.62 5.45 3.79 5.59 3.76 5.71 3.72 5.96 3.83 6.17 3.72
26 4.74 3.60 5.01 3.56 5.34 3.74 5.49 3.71 5.61 3.67 5.87 3.79 6.08 3.69
28 4.61 3.54 4.89 3.50 5.23 3.69 5.39 3.67 5.50 3.63 5.78 3.76 5.99 3.66
30 4.49 3.46 4.76 3.43 5.11 3.64 5.28 3.62 5.40 3.58 5.68 3.72 5.90 3.62
32 4.35 3.40 4.63 3.37 5.00 3.58 5.17 3.57 5.29 3.54 5.58 3.68 5.81 3.59
34 4.22 3.33 4.49 3.31 4.88 3.52 5.06 3.52 5.18 3.49 5.48 3.64 5.71 3.55
35 4.15 3.29 4.42 3.27 4.82 3.49 5.00 3.49 5.12 3.45 5.43 3.62 5.66 3.53
36 4.08 3.26 4.35 3.24 4.76 3.47 4.94 3.46 5.06 3.43 5.37 3.60 5.61 3.50
38 3.94 3.19 4.21 3.18 4.63 3.42 4.82 3.42 4.94 3.39 5.27 3.54 5.50 3.47
39 3.87 3.15 4.14 3.14 4.57 3.39 4.76 3.39 4.88 3.36 5.21 3.52 5.45 3.45
Heating Mode (HC) (kW)(kW)
Note(1) These data show average statuses.
Depending on the system control, there may be ranges where the operation is not conducted continuously. These data show the case where the operation frequency of a compressor is fixed.
(2) Capacities are based on the following conditions.
Corresponding refrigerant piping length :7m Level difference of Zero.
(3) Symbols are as follows.
TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) HC : Heating capacity (kW)
-
27
-
'14 • SRK-T-154
BEFORE INSTALLATION
Before installation check that the power supply matches the air conditioner.
SELECTION OF INSTALLATION LOCATION
INSTALLATION OF INDOOR UNIT
Indoor unit
(Install at location that meets the following conditions, after getting approval from the customer)
Where there is no obstructions to the air flow and where the cooled and heated air can be evenly distributed.
A solid place where the unit or the wall will not vibrate.
A place where there will be enough space for servicing. (Where space mentioned below can be secured)
Where wiring and the piping work will be easy to conduct.
The place where receiving part is not exposed to the direct rays of the sun or the strong rays of the street lighting.
A place where it can be easily drained.
A place separated at least 1m away from the television or the radio. (To prevent interference to images and sounds.)
Places where this unit is not affected by the high frequency equipment or electric equipment.
Avoid installing this unit in place where there is much oil mist.
Places where there is no electric equipment or household under the installing unit.
Wireless remote control
A place where the air conditioner can be received the signal surely during operating the wireless remote control.
Places where there is no affected by the TV and radio etc.
Do not place where exposed to direct sunlight or near heat devices such as a stove.
5 cm mini
m
um
from the
w
all
10 cm
minim
um
from the
w
all
Installation board
Sleeve
(sold separately)
6.5 cm minimum from the ceiling
R410A REFRIGERANT USED
WALL TYPE AIR CONDITIONER
INSTALLATION MANUAL FOR INDOOR UNIT
RLA012A020
CAUTION
Completely seal the hole on
the wall with putty. Otherwise,
furniture, or other, may be
wetted by leaked water or
dewing.
putty
putty
1
1
1
5
2
2
Q’ty
Standard accessories (Installation kit)
Accessories for indoor unit
Installation board
(Attached to the rear of the indoor unit)
Wireless remote control
Remote control holder
Battery <3""".JDSP7>
Tapping screws
(for installation board ø4 X 25mm)
Wood screws
(for remote control holder ø3.5 X 16mm)
1
2
3
4
5
6
Indoor side
Outdoor side
WARNING
s Installation must be carried out by the qualified installer.
If you install the system by yourself, it may cause serious trouble such as
water leaks, electric shocks, fire and personal injury, as a result of a system
malfunction. Do not carry out the installation and maintenance work except
the by qualified installer.
s Install the system in full accordance with the installation manual.
Incorrect installation may cause bursts, personal injury, water leaks, electric
shocks and fire.
s Be sure to use only for household and residence.
If this appliance is installed in inferior environment such as machine shop
and etc., it can cause malfunction.
s Use the original accessories and the specified components for
installation.
If parts other than those prescribed by us are used, It may cause water
leaks, electric shocks, fire and personal injury.
s Install the unit in a location with good support.
Unsuitable installation locations can cause the unit to fall and cause
material damage and personal injury.
s Ventilate the working area well in the event of refrigerant leakage
during installation.
If the refrigerant comes into contact with naked flames, poisonous gas is
produced.
s When installing in small rooms, take prevention measures not to
exceed the density limit of refrigerant in the event of leakage,
referred by the formula (accordance with ISO5149).
If the density of refrigerant exceeds the limit, please consult the dealer and
install the ventilation system, otherwise lack of oxygen can occur, which
can cause serious accident.
s After completed installation, check that no refrigerant leaks from
the system.
If refrigerant leaks into the room and comes into contact with an oven or
other hot surface, poisonous gas is produced.
s Use the prescribed pipes, flare nuts and tools for R410A.
Using existing parts (for R22 or R407C) can cause the unit failure and
serious accidents due to burst of the refrigerant circuit.
s Tighten the flare nut by torque wrench with specified method.
If the flare nut were tightened with excess torque, this may cause burst and
refrigerant leakage after a long period.
s The electrical installation must be carried out by the qualified
electrician in accordance with “the norm for electrical work” and
“national wiring regulation”, and the system must be connected to
the dedicated circuit.
Power supply with insufficient capacity and incorrect function done by
improper work can cause electric shocks and fire.
s Be sure to shut off the power before starting electrical work.
Failure to shut off the power can cause electric shocks, unit failure or
incorrect function of equipment.
s Be sure to use the cables conformed to safety standard and cable
ampacity for power distribution work.
Unconformable cables can cause electric leak, anomalous heat production
or fire.
s This appliance must be connected to main power supply by means
of a circuit breaker or switch (fuse:16A) with a contact separation of
at least 3mm.
s When plugging this appliance, a plug conforming to the norm
IEC60884-1 must be used.
s Use the prescribed cables for electrical connection, tighten the
cables securely in terminal block and relieve the cables correctly to
prevent overloading the terminal blocks.
Loose connections or cable mountings can cause anomalous heat
production or fire.
s Arrange the wiring in the control box so that it cannot be pushed up
further into the box. Install the service panel correctly.
Incorrect installation may result in overheating and fire.
s Be sure to switch off the power supply in the event of installation,
inspection or servicing.
If the power supply is not shut off, there is a risk of electric shocks, unit
failure or personal injury due to the unexpected start of fan.
s Be sure to wear protective goggles and gloves while at work.
s Earth leakage breaker must be installed.
If the earth leakage breaker is not installed, it can cause electric shocks.
CAUTION
s Use the circuit breaker of correct capacity. Circuit breaker should
be the one that disconnect all poles under over current.
Using the incorrect one could cause the system failure and fire.
s Install isolator or disconnect switch on the power supply wiring in
accordance with the local codes and regulations.
The isolator should be locked in OFF state in accordance with EN60204-1.
s Be sure to install indoor unit properly according to the installation
manual in order to run off the drainage smoothly.
Improper installation of indoor unit can cause dropping water into the room
and damaging personal property.
s Install the drainage pipe to run off drainage securely according to
the installation manual.
Incorrect installation of the drainage pipe can cause dropping water into the
room and damaging personal property.
s Be sure to install the drainage pipe with descending slope of 1/100
or more, and not to make traps and air-bleedings.
Check if the drainage runs off securely during commissioning and ensure
the space for inspection and maintenance.
s Secure a space for installation, inspection and maintenance
specified in the manual.
Insufficient space can result in accident such as personal injury due to
falling from the installation place.
s For installation work, be careful not to get injured with the heat
exchanger, piping flare portion or screws etc.
s Be sure to insulate the refrigerant pipes so as not to condense the
ambient air moisture on them.
Insufficient insulation can cause condensation, which can lead to moisture
damage on the ceiling, floor, furniture and any other valuables.
s When perform the air conditioner operation (cooling or drying opera-
tion) in which ventilator is installed in the room. In this case, using the
air conditioner in parallel withthe ventilator, there isthe possibility
that drain water may backflow in accordance with the room lapse into
the negative pressure status. Therefore, set up the opening port such
as incorporate the air into the room that may appropriate to ventila-
tion (For example; Open the door a little). In addition, just as above, so
set up the opening port if the room lapse into negative pressure status
due to register of the wind for the high rise apartment etc.
s Be sure to perform air tightness test by pressurizing with nitrogen
gas after completed refrigerant piping work.
If the density of refrigerant exceeds the limit in the event of refrigerant
leakage in the small room, lack of oxygen can occur, which can cause
serious accidents.
s Do not install the unit in the locations listed below.
t Locations where carbon fiber, metal powder or any powder is floating.
t Locations where any substances that can affect the unit such as sulphide
gas, chloride gas, acid and alkaline can occur.
t Vehicles and ships.
t Locations where cosmetic or special sprays are often used.
t Locations with direct exposure of oil mist and steam such as kitchen and
machine plant.
t Locations where any machines which generate high frequency harmonics
are used.
t Locations with salty atmospheres such as coastlines.
t Locations with heavy snow (If installed, be sure to provide base flame and
snow hood mentioned in the manual).
t Locations where the unit is exposed to chimney smoke.
t Locations at high altitude (more than 1000m high).
t Locations with ammonic atmospheres.
t Locations where heat radiation from other heat source can affect the unit.
t Locations without good air circulation.
t Locations with anyobstacles whichcan preventinlet and outlet air of the unit.
t Locations where short circuit of air can occur (in case of multiple units
installation).
t Locations where strong air blows against the air outlet of outdoor unit.
t Locations where something located above the unit could fall.
It can cause remarkable decrease in performance, corrosion and damage
of components, malfunction and fire.
s Do not install the indoor unit in the locations listed below (Be sure
to install the indoor unit according to the installation manual for
each model because each indoor unit has each limitation).
t Locations with any obstacles which can prevent inlet and outlet air of the
unit.
t Locations where vibration can be amplified due to insufficient strength of
structure.
t Locations where the infrared receiver is exposed to the direct sunlight or
the strong light beam (in case of the infrared specification unit).
t Locations where an equipment affected by high harmonics is placed (TV
set or radio receiver is placed within 1m).
t Locations where drainage cannot run off safely.
It can affect performance or function and etc.
s Do not install the unit near the location where leakage of
combustible gases can occur.
If leaked gases accumulate around the unit, it can cause fire.
s Do not install the unit where corrosive gas (such as sulfurous acid
gas etc.) or combustible gas (such as thinner and petroleum gases)
can accumulate or collect, or where volatile combustible
substances are handled.
Corrosive gas can cause corrosion of heat exchanger, breakage of plastic
parts and etc. And combustible gas can cause fire.
s Do not use the indoor unit at the place where water splashes may
occur such as in laundries.
Since the indoor unit is not waterproof, it can cause electric shocks and fire.
s Do not install nor use the system close to the equipment that
generates electromagnetic fields or high frequency harmonics.
Equipment such as inverters, standby generators, medical high frequency
equipments and telecommunication equipments can affect the system, and
cause malfunctions and breakdowns. The system can also affect medical
equipment and telecommunication equipment, and obstruct its function or
cause jamming.
s Do not place any variables which will be damaged by getting wet
under the indoor unit.
When the relative humidity is higher than 80% or drainage pipe is clogged,
condensation or drainage water can drop and it can cause the damage of
valuables.
s Do not install the wireless remote control at the direct sunlight.
It can cause malfunction or deformation of the wireless remote control.
s Do not use the unit for special purposes such as storing foods,
cooling precision instruments and preservation of animals, plants or
art.
It can cause the damage of the items.
s Do not use any materials other than a fuse with the correct rating in
the location where fuses are to be used.
Connecting the circuit with copper wire or other metal thread can cause
unit failure and fire.
s Do not touch any buttons with wet hands.
It can cause electric shocks.
s Do not touch any refrigerant pipes with your hands when the
system is in operation.
During operation the refrigerant pipes become extremely hot or extremely
cold depending the operating condition, and it can cause burn injury or
frost injury.
s Carry out the electrical work for ground lead with care.
Do not connect the ground lead to the gas line, water line, lightning conductor or telephone line’s ground lead. Incorrect grounding can cause unit faults
such as electric shocks due to short-circuiting.
s Do not put the drainage pipe directly into drainage channels where
poisonous gases such as sulphide gas can occur.
Poisonous gases will flow into the room through drainage pipe and
seriously affect the user’s health and safety. This can also cause the
corrosion of the indoor unit and a resultant unit failure or refrigerant leak.
s Ensure that no air enters in the refrigerant circuit when the unit is
installed and removed.
If air enters in the refrigerant circuit, the pressure in the refrigerant circuit
becomes too high, which can cause burst and personal injury.
s Do not processing, splice the power cord, or share a socket with
other power plugs.
This may cause fire or electric shock due to defecting contact, defecting
insulation and over-current etc.
s Do not bundling, winding or processing for the power cord. Or, do
not deforming the power plug due to tread it.
This may cause fire or heating.
s Do not vent R410A into the atmosphere : R410A is a fluorinated
greenhouse gas, covered by the Kyoto Protocol with Groval
Warming Potential (GWP)=1975.
s Do not run the unit with removed panels or protections.
Touching rotating equipments, hot surfaces or high voltage parts can cause
personal injury due to entrapment, burn or electric shocks.
s Do not perform any change of protective device itself or its setup
condition.
The forced operation by short-circuiting protective device of pressure
switch and temperature controller or the use of non specified component
can cause fire or burst.
WARNING
SAFETY PRECAUTIONS
t Read the “SAFETY PRECAUTIONS” carefully first of all and strictly follow it
during the installation work in order to protect yourself.
t The precautionary items mentioned below are distinguished into two levels,
and .
: Wrong installation would cause serious consequences such
as injuries or death.
: Wrong installation might cause serious consequences
depending on circumstances.
Both mentions the important items to protect your health and safety so strictly
follow them by any means.
t Be sure to confirm no anomaly on the equipment by commissioning after com-
pleted installationand explain the operating methodsas well as the maintenance
methods of thisequipment to the user accordingto the owner’s manual.
t Keep the installation manual together with owner’s manual at a place where
any user can read at any time. Moreover if necessary, ask to hand them to a
new user.
t For installing qualified personnel, take precautions in respect to themselves by
using suitable protective clothing, groves, etc., and then perform the
installation works.
t Please pay attention not to fall down the tools, etc. when installing the unit at
the high position.
t If unusual noise can be heard during operation, consult the dealer.
t The meanings of “Marks” used here are shown as follows:
Never do it under any
circumstances.
Always do it according to the
instruction.
CAUTIONWARNING
CAUTION
WARNING
s This installation manual illustrates the method of installing an indoor
unit.
s For electrical wiring work, please see instructions set out on the
backside.sFor outdoor unit installation and refrigerant piping, please refer to page 31.
s A wired remote control unit is supplied separately as an optional part.
s When install the unit, be sure to check whether the selection of
installation place, power supply specifications, usage limitation (piping
length, height differences between indoor and outdoor units, power
supply voltage and etc.) and installation spaces.
8. APPLICATION DATA
(1) Installation of indoor unit
Models SRK20ZMA-S, 25ZMA-S, 35ZMA-S, 50ZMA-S
-
28
-
'14 • SRK-T-154
Necessary tools for the installation work
1
2
3
4
5
6
7
8
9
10
11
12
13
1
1
1
1
1
1
Q’ty
Option parts
Sealing plate
Sleeve
Inclination plate
Putty
Drain hose (extension hose)
Piping cover
(for insulation of connection piping)
Plus headed driver
Knife
Saw
Tape measure
Hammer
Spanner wrench
Torque wrench
Hole core drill (65mm in diameter)
Wrench key (Hexagon) [4m/m]
Flaring tool set
Gas leak detector
Pipe bender
Gauge for projection adjustment
Used when flare is made by using
conventional flare tool
( )
( )
14.0 ~ 61.0N·m
(1.4 ~ 6.1kgf·m)
(
Designed specifically
for R410A
)
Piping in the left direction
Piping in the right rear directionPiping in the left rear direction
Piping in the right direction
INSTALLATION SPACE (INDOOR UNIT)
(FRONT VIEW)
Piping is possible in the rear, left, left rear, left downward, right or downward direction.
Right
Rear
Downward
Left
rear
Left downward
Left
BEFORE INSTALLATION
Before installation check that the power supply matches the air conditioner.
SELECTION OF INSTALLATION LOCATION
INSTALLATION OF INDOOR UNIT
Indoor unit
Relation between setting plate and indoor unit
Installing the support of piping
(Install at location that meets the following conditions, after getting approval from the customer)
Where there is no obstructions to the air flow and where the cooled and heated air can be evenly distributed.
A solid place where the unit or the wall will not vibrate.
A place where there will be enough space for servicing. (Where space mentioned below can be secured)
Where wiring and the piping work will be easy to conduct.
The place where receiving part is not exposed to the direct rays of the sun or the strong rays of the street lighting.
A place where it can be easily drained.
A place separated at least 1m away from the television or the radio. (To prevent interference to images and sounds.)
Places where this unit is not affected by the high frequency equipment or electric equipment.
Avoid installing this unit in place where there is much oil mist.
Places where there is no electric equipment or household under the installing unit.
Wireless remote control
In case of piping in the right rear direction
A place where the air conditioner can be received the signal surely during operating the wireless remote control.
Places where there is no affected by the TV and radio etc.
Do not place where exposed to direct sunlight or near heat devices such as a stove.
Sufficient care must be taken not to damage
the panel when connecting pipes.
[Top view]
When drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use pipe hole sleeve sold separately.
t.BUUFSTPGTQFDJBMOPUJDFXIFOQJQJOHGSPNMFGUPSDFOUSBMSFBSPGUIFVOJU
Left-hand-side piping Right-hand-side piping
Installation of installation board
Drilling of holes and fixture of sleeve (Option parts)
Level position (2 locations)
Mating mark for
level surface
Fixing on concrete wall
Use of nut anchor
Use of bolt anchor
Shaping of pipings Taping of the exterior
Pipings
Drain hose
Top
Nut
(M6)
Mounting
board
Mounting
board
Max.10
Thickness of the wall + 1.5cm
5
ø65
Indoor side
Outdoor sideIndoor side Outdoor side Installed state
Turn to
tighten
b
b
c
a
Bolt
(M6 12)
5 cm mini
m
um
from the
w
all
10 cm
minim
um
from the
w
all
Installation board
Sleeve
(sold separately)
6.5 cm minimum from the ceiling
In case of rear piping draw out, cut off the lower
and the right side portions of the sleeve collar.
Drill a hole with whole core drill.
Hold the bottom of the
piping and fix direction
before stretching it and
shaping it.
Tape only the portion
that goes through the
wall.
Always tape the wiring
with the piping.
[Drain hose changing procedures]
1. Remove the drain hose 2. Remove the drain cap.
Remove it with hand or pliers.
Remove the screw and drain hose,
making it rotate.
3. Insert the drain cap. 4. Connect the drain hose.
Insert the drain cap which was removed
at procedure “2” securely using a
hexagonal wrench etc.
Note: Be careful that If it is not inserted
securely, water leakage may occur.
Insert the drain hose securely, making
rotate. And install the screw.
Note: Be careful that If it is not inserted
securely, water leakage may
occur.
Adjustment of the installation board in the horizontal direction is to
be conducted with four screws in a temporary tightened state.
Adjust so the board will be
level by turning the board
with the standard hole as
the center.
450
Look for the inside wall structures (Intermediats support or pillar
and firmly install the unit after level surface has been checked.)
Standard
hole
Piping for Liquid Model SRK2050, DXK0918 : ø6.35
Piping for Gas Model SRK2035, DXK09 / 12 : ø9.52
Model SRK50, DXK18 : ø12.7
CAUTION
Completely seal the hole on
the wall with putty. Otherwise,
furniture, or other, may be
wetted by leaked water or
dewing.
putty
putty
1
1
1
5
2
2
2
2
1
Q’ty
Standard accessories (Installation kit)
Accessories for indoor unit
Installation board
(Attached to the rear of the indoor unit)
Wireless remote control
Remote control holder
Battery <3""".JDSP7>
Air-cleaning filters
Filter holders
(Attached to the front panel of indoor unit)
Insulation (#486 50 x 100 t3)
Tapping screws
(for installation board ø4 X 25mm)
Wood screws
(for remote control holder ø3.5 X 16mm)
1
2
3
4
5
6
7
8
9
( )
Designed specifically
for R410A
Space for service Space for service
Indoor unit
Installation board
Piping hole (ø65)
Drain hose (ø16)
Piping for Liquid
Piping for Gas
Piping hole (ø65)
Space
for service
48.9
47
65
139 450 209
106.5 585 106.5
50 100
7.2 7.7279.1
47
15 Space
for service
55
531.8
471.6
403.6
55
Indoor side
Outdoor side
Wireless remote control
Remote control holder
Wood screws
(Unit : mm)