Mitsubishi Electric SRK63HE-S1, SRK71HE-S1, SRK63CE-S1, SRK71CE-S1 User Manual

MANUEL DE L’UTILISATEUR
CLIMATISEUR
ANWENDERHANDBUCH
KLIMAGERA¨T
ISTRUZIONI PER L’USO
MANUAL DEL PROPIETARIO
ACONDICIONADOR DE AIRE
GEBRUIKERSHANDLEIDING
AIRCONDITIONING
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO
√¢∏°π∂™ Ã∏™∏™
∫§πª∞∆π™∆π∫√
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
КОНДИЦИОНЕР ВОЗДУХА
KULLANIM KILAVUZU
SPL‹T KL‹MA
Deze airconditioner voldoet aan EMC Directive 89/336/EEC, LV Directive 73/23/EEC.
Este acondicionador de aire cumple con la directiva EMC: 89/ 336/EEC, LV Directiva 73/23/EEC.
Este aparelho de ar condicionado está em conformidade com a Directiva EMC 88/336/CEE e a Directiva LV 72/23/CEE.
∞˘Щfi ЩФ ОПИМ·ЩИЫЩИОfi В›У·И Ы‡МКˆУФ МВ ЩИ˜ ЪФ‰И·БЪ·К¤˜ ЩЛ˜ √‰ЛБ›·˜ EMC 88/396 Î·È Ù˘ √‰ËÁ›·˜ LV 73/23 Ù˘ ∂√∫.
USER’S MANUAL
AIR-CONDITIONER
RKW012A211
ENGLISH
DEUTSCH
ITALIANO
ESPAN˜OL
NEDERLANDS
PORTUGUÊS
∂§§∏¡π∫∞
РУССКИЙ
TÜRKÇE
FRANÇAIS
Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES, LTD. Air-Conditioner. To get the best long-lasting performance, read and follow this User’s Manual carefully before using your air-conditioner. After reading, please store the Manual in a safe place and refer to it for operational questions or in the event of any irregularities.
This air-conditioner is intended for domestic use.
This instruction manual contains the explanation of the heatpump air-conditioner. That of cooling-only air-conditioner shall be referred to the same explanation , with neglecting the information on heating-operation mode.
An alternative refrigerant (R410A) is used in this air-conditioner. When asking the dealer for service or inspection and maintenance, explain the dealer about this matter.
contents
Safety precautions......................................................................................................................... 2
Choice of operations and features ................................................................................................ 4
Name of each part and its function ............................................................................................... 5
Operation and indication section for remote control .................................................................... 7
AUTO mode operation procedure ................................................................................................ 8
ENGLISH
Temperature adjustment during AUTO ........................................................................................ 8
About FAN SPEED ...................................................................................................................... 8
COOL/HEAT/DRY/FAN mode operation procedure .................................................................. 9
Air-conditioner operating conditions............................................................................................9
Characteristics of HEAT mode operation .................................................................................... 9
Air flow direction adjustment procedure .................................................................................... 10
SLEEP operation procedure .......................................................................................................11
OFF-TIMER operation procedure .............................................................................................. 11
ON-TIMER operation procedure................................................................................................ 12
SLEEP operation + ON-TIMER operation procedure ............................................................... 12
PROGRAM TIMER operation procedure .................................................................................. 13
Present time setting procedure .................................................................................................... 13
HIGH POWER/ECONOMY operation procedure ..................................................................... 14
Concerning CLEAN operation ................................................................................................... 15
Emergency run operation............................................................................................................ 15
Power blackout auto restart function .......................................................................................... 15
Remote control handling procedure ........................................................................................... 16
When the operation fails with the remote control ...................................................................... 16
Operating hints ........................................................................................................................... 17
Maintenance................................................................................................................................ 17
Has the unit been installed correctly? ......................................................................................... 19
Troubleshooting .......................................................................................................................... 19
Please remember! ....................................................................................................................... 20
When to contact your distributor without delay ......................................................................... 21
Self diagnosis function ............................................................................................................... 21
–1–
Safety precautions
Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system.
The safety precautions are classified as “
improper handling could have dramatic consequences like death, serious injury, etc. Nevertheless, even precautions as shown in the column “
CAUTION” might pose a serious problem, depending on the circumstances. Please observe these precautions with great care, since they are
essential to your safety.
Symbols which appear frequently in the text have the following meaning:
DANGER” and “ CAUTION”. Precautions as shown in the column “ DANGER” indicate that
Strictly prohibited Provide positive earthing
When you have read the instruction manual, please keep it near at hand for consultation. If someone else takes over as operator, make certain that the manual is also passed on to the new operator.
Observe instructions with great care
INSTALLATION PRECAUTIONS
DANGER
The system is meant for domestic, residential etc. use.
If used in inferior environments, such as an engineering workplace, the equipment may function poorly.
Do not install near places where inflammable gas may leak.
LPG
Gas leaks may cause fire.
Make sure that you drain the hose properly, so that all the water has dripped out.
The system must be installed by your dealer or a qualified pro­fessional.
It is not advisable to install the system yourself, as faulty handling may cause leak­age of water, electric shock or fire.
CAUTION
Depending on the place of installation, a circuit breaker may be necessary.
If you don’t fit a circuit breaker, you may cause an electric shock.
Make sure that the system has been properly earthed.
Negligence may cause flooding in the room resulting in wet furniture.
OPERATION PRECAUTIONS
Do not expose yourself to the cooling air for prolonged periods.
This could affect your physical condition and cause health problems.
Only use approved fuses.
Use of steel or copper wire instead of an approved fuse is strictly forbidden, as it may cause a breakdown or fire.
Earth cables should never be connected to a gas pipe, municipal water pipe, light­ning conductor or telephone earth cable. Incorrect installation of the earth cable may produce an electric shock.
DANGER
Do not insert anything into the air inlet.
This may cause injury, as the internal fan rotates at high speed.
CAUTION
Do not handle the switches with wet hands.
This may cause an electric shock.
2
Store the remote control out of reach of infants.
Failure to observe this may result in the batteries being swallowed or other accidents.
Don’t swing from the system.
If the system falls down, you may get injured.
Safety precautions
CAUTION
Do not place a combustible insecticide or paint spray near the blower, nor aim it directly at the system.
This may result in a fire.
The system should only be used for its original purpose and not for anything else like, for instance, preservation of
You should not expose any combus­tion appliance directly to the air stream of the air-conditioner.
The appliance may then work inadequately.
Do not place anything containing wa­ter, like vases, on top of the unit.
food, plants or animals, precision devices or works of art.
The system is only intended for use in ordinary domestic rooms. Any other use of the system may damage the quality of food, etc.
Do not sit on the outdoor unit nor put anything on it.
Water entering the unit could damage the insula­tion and therefore cause an electric shock.
After a long period of use, check the unit's support structure from time to time.
Do not wash the air-conditioner with wa­ter.
This could cause an electric shock.
Do not install the system at a place where the air stream of the blower is aimed directly at plants or animals.
This will damage their health.
Do not touch the aluminum fins on the air heat exchanger.
If the unit falls down or things drop off it, people could get hurt.
If you operate the system together with a combustion appliance, you must regu­larly ventilate the indoor air.
Insufficient ventilation may cause accidents due to oxygen deficiency.
If you don't repair any damage straightaway, the unit may fall down and cause personal injury.
Stand firmly on a stepladder or other stable object when removing the inlet panel and filters.
Failure to observe this may result in injury through insecure objects toppling over.
Do not place objects near the outdoor unit or allow leaves to gather around the unit.
If there are objects or leaves around the outdoor unit, small animals may enter unit and contact electrical parts resulting in break down, emission of smoke or flame.
PRECAUTIONS FOR TRANSFER OR REPAIRS
DANGER
Consult your dealer for repairs to the system.
If the air-conditioner is moved else­where, contact your dealer or a pro­fessional fitter.
Failure to observe this may result in injury.
When you clean the system, stop the unit and turn off the power switch.
Never clean the unit while the internal fan is rotating.
If you notice anything abnormal (smell of burning, etc.), stop the system, turn off the power switch and consult your dealer.
Wrong repairs could cause an electric shock, fire, etc.
Faulty installation may cause water leakage, elec­tric shock, fire, etc.
3
Continued use of the system in abnormal circum­stances may result in malfunctioning, electric shock, fire, etc.
Choice of operations and features
Choice of operations
HEAT
The unit draws in heat from the outside air, transfers it inside and heats the room.
Fanning by circulating room air.
Page 9
Page 9
COOL
Cooling by extracting heat from the room.
AUTOFAN
Automatic selection of operating mode.
Page 9
Page 8
DRY
Drying by extracting damp from the room.
Functioning of microcomputer depends on setting and room temperatures. It dehumidi­fies while keeping room temperature almost constant.
The Auto mode automatically selects the operation mode (HEAT, COOL or DRY), depending on the room temperature when switched on.
Page 9
Features
Amenity facility
When using the timer to switch on, the sys­tem should become operational shortly be­fore the set time, depending on the room temperature so that the desired temperature should be reached at the set time.
Adjustment of
airflow
Page 13
Page 10
MULTI-DIRECTIONAL AIR FLOW This function sets the unit at the most suitable angle
for blowing, imitating a natural breeze.
SWING FLAP Flap moves up and down continuously.
SWING LOUVER Louver moves left and right continuously.
MEMORY FLAP (FLAP OR LOUVER STOPPED) Once the flap or louver position has been set, the unit
will memorise it and continue in the same position the next time.
TIMER procedure
There are three timers, for SLEEP, ON and OFF. They can be set as desired.
Page 11, 12
HIGH POWER mode
Turning up the power operates the air-condi­tioner in the power cooling and heating mode.
ECONOMY mode
This is an economic level of operation.
Page 14
Page 14
4
Name of each part and its function
INDOOR UNIT
SRK63HE-S1 SRK71HE-S1
SRK63CE-S1 SRK71CE-S1
Air inlet panel
Draws in the indoor air.
Unit indication section and remote control signal receiver
Wireless remote control
Air filter
Removes dust or dirt from the inlet air.
Page 17
Photocatalytic washable deodorizing filter
Natural enzyme filter
Room temperature detector
Unit operation switch
OUTDOOR UNIT
SRC63HE-S1 SRC71HE-S1
SRC63CE-S1 SRC71CE-S1
Air inlet
(on side & rear surface)
Air outlet
Air blows out of here.
Left/right air flow adjustment louver
Page 10
Up/down air flow direction adjustment flap
Page 10
Drain hose
Drains water from the dehumidified air.
Refrigerant piping connection electric flex
Accessories
Wireless remote control
Wireless remote
control holder
Battery (R03×2)
Wood screw (Quantity:2)
(for remote control holder mounting)
Air outlet
* The appearance varies for Models 63 and 71.
5
Natural enzyme filter
(green)
Photocatalytic washable deodoriz-
ing filter (orange)
Unit indication section
HI POWER light (green)
Illuminates during HIGH POWER operation.
ECONOMY light (orange)
Illuminates during ECONOMY operation.
RUN (HOT KEEP) light (green)
Illuminates during operation.
Blinks at air flow stop due to the HOT KEEP
and CLEAN operation’.
HOT KEEP
CLEAN operation
ON
OFF
ON
OFF
1.5 sec.
3 sec.
Page 20
0.5 sec.
1 sec.
TIMER light (yellow)
Illuminates during TIMER operation.
How to open the air inlet panel
Place fingers at the recesses on both sides of the panel and pull up the panel to this side so that it will be opened by about 60 degrees.
How to close the air inlet panel
Push both sides evenly and press further lightly at the center.
Removal, installation of air inlet panel
When removing the air inlet panel for internal cleaning or others, open the panel by 80 degrees and then pull it to this side.
Unit ON/OFF button
In emergencies, this button can be used for turning on/off the unit when re-
mote control is not available.
Page 15
Unit ON/OFF button
Secure either the upper or lower edge of the air inlet panel by lightly pushing it in, and then close the panel.
6
Loading...
+ 16 hidden pages