Mitsubishi SRK63ZK-S, SRK80ZK-S, SRK71ZK-S User Manual

USER’S MANUAL
SRK63ZK-S SRK71ZK-S SRK80ZK-S
AIR-CONDITIONER
MANUEL DE L’UTILISATEUR
ANWENDERHANDBUCH
ISTRUZIONI PER L’USO
CONDIZIONATORE D’ARIA
MANUAL DEL PROPIETARIO
ACONDICIONADOR DE AIRE
GEBRUIKERSHANDLEIDING
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO
ENGLISH
FRANÇAIS
CLIMATISEUR
DEUTSCH
KLIMAGERA¨T
ITALIANO
ESPAN˜OL
NEDERLANDS
AIRCONDITIONING
PORTUGUÊS
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
This air conditioner complies with EMC Directive 2004/108/EC, LV Directive 2006/95/EC.
Ce climatiseur est conforme à la Directive EMC: 2004/108/EC, LV Directive 2006/95/EC.
Dieses Kimagerät erfüllt die EMC Direktiven 2004/108/EC, LV Direktiven 2006/95/EC.
Questo condizionatore d’aria è conforme alla Direttiva EMC: 2004/ 108/EC, LV Direttiva 2006/95/EC.
ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ
ΚΛΙΜΑΤΙΣΤΙΚΟ
КОНДИЦИОНЕР ВОЗДУХА
KULLANIM KILAVUZU
Este acondicionador de aire cumple con la directiva EMC: 2004/ 108/EC, LV Directiva 2006/95/EC.
Deze airconditioner voldoet aan EMC Directive 2004/108/EC, LV Directive 2006/95/EC.
Este aparelho de ar condicionado está em conformidade com a Directiva EMC 2004/108/EC e a Directiva LV 2006/95/EC.
∞˘Щfi ЩФ ОПИМ·ЩИЫЩИОfi В›У·И Ы‡МКˆУФ МВ ЩИ˜ ЪФ‰И·БЪ·К¤˜ ЩЛ˜ √‰ЛБ›·˜ EMC 2004/108/EK Î·È Ù˘ √‰ËÁ›·˜ LV 2006/95/EK.
ΕΛΛΗΝΙΚΑ
РУССКИЙ
TÜRKÇE
RKW012A401B
Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES, LTD. Air-Conditioner. To get the best long-lasting performance, please read and follow this User’s Manual carefully before using your air-conditioner. After reading, please store the Manual in a safe place and refer to it for operational questions or in the event of any irregularities.
This air-conditioner is intended for domestic use.
Do not vent R410A into the atmosphere: R410A is a fluorinated greenhouse gas, covered by the Kyoto Protocol with a Global Warming Potential (GWP) = 1975.
Your Air Conditioning product may be marked with this symbol. It means that waste electrical and electronic equipment (WEEE as in directive 2002/ 96/EC) should not be mixed with general household waste. Air conditioners should be treated at an authorized treatment facility for re-use, recycling and recovery and not be disposed of in the municipal waste stream. Please contact the installer or local authority for more information.
This symbol printed in the batteries attached to your Air Conditioning product is information for end-users according to the EU directive 2006/66/ EC article 20 annex II. Batteries, at their end-of-life, should be disposed of separately from general household waste. If a chemical symbol is printed beneath the symbol shown above, this chemical symbol means that the batteries contain a heavy metal at a certain concentration. This will be indicated as follows: Hg:mercury(0.0005%) , Cd:cadmium(0.002%) , Pb:lead(0.004%) Please, dispose of batteries correctly at your local community waste collection or the recycling center.
ENGLISH
The emission sound pressure level from each Indoor and Outdoor unit is under 70 dB(A).
contents
Safety precautions ........................................ 2
Name of each part and its function ............... 4
Remote control handling ............................... 6
Operation failure with the remote control ...... 6
Temporary run operation .............................. 6
Operation and display section for
remote control ............................................... 7
Current time setting....................................... 7
AUTO mode operation .................................. 8
Temperature adjustment during AUTO......... 8
FAN SPEED.................................................. 8
COOL/HEAT/DRY/FAN mode operation ...... 9
OFF-TIMER operation ................................ 11
ON-TIMER operation .................................. 12
SLEEP TIMER + ON-TIMER operation ...... 12
PROGRAM TIMER operation ..................... 13
ALLERGEN CLEAR operation .................... 13
HIGH POWER/ECONOMY operation......... 14
SELF CLEAN operation .............................. 15
Auto restart function .................................... 15
Tips for effective operation ......................... 15
Maintenance ............................................... 16
Proper installation ....................................... 18
Troubleshooting .......................................... 18
Air-conditioner operable
temperature setting ....................................... 9
Characteristics of HEAT mode operation ..... 9
Airflow direction adjustment ........................ 10
SLEEP TIMER operation ............................ 11
Notice .......................................................... 19
Contact your dealer..................................... 20
About the Multiple Air-conditioner ............... 20
Self diagnosis function ................................ 21
–1–
Safety precautions
Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the
system.
When you have read this instruction manual, please keep it without missing. If someone else takes over as operator,
make certain that the manual is also passed on to the new operator.
DANGER
CAUTION
Please observe these precautions with great care, since they are essential to your safety.
Symbols which appear frequently in the text have the following meaning:
Strictly prohibited Provide proper earthing
Improper handling could lead to drastic result like death, serious injury, etc. Might pose a serious problem, depending on the circumstances.
Observe instructions with great care
INSTALLATION PRECAUTIONS
DANGER
The system is for domestic, residential etc. use.
If used in severer environments, such as an engineering workplace, the equipment may function poorly.
The system must be installed by your dealer or a qualified professional.
It is not advisable to install the system by yourself, as faulty handling may cause leakage of water, electric shock or fire.
CAUTION
Do not install it where flammable gas may leak.
Gas leaks may cause fire.
Depending on the place of installation, an
earth leakage breaker may be necessary.
If you do not install an earth leakage breaker, you may get an electric shock.
Make sure to install the drain hose properly
so that all the water is drained out.
Improper installation may lead to water drop in the room resulting in wet furniture.
Make sure that the system has been properly earthed.
Earth cables should never be connected to a gas pipe, water pipe, lightning conductor or telephone earth cable. Incorrect installation of the earth cable may produce an electric shock.
OPERATION PRECAUTIONS
Do not expose yourself to the cooling air for a
long period.
This could affect your physical condition and cause health problems.
Store the remote control out of reach of infants.
Failure to observe this may result in the batteries being swallowed or other accidents.
Only use approved fuses.
Use of steel or copper wire instead of an approved fuse is strictly prohibited, as it may cause a break­down or fire.
Do not handle the switches with wet hands.
This may cause an electric shock.
Do not swing from the indoor unit.
If the indoor unit falls down,you may get injured.
DANGER
Do not insert anything into the air inlet.
This may cause injury, as the internal fan rotates at high speed.
CAUTION
Do not place a flammable insecticide or paint
spray near the blower, nor spray it directly on the system.
This may result in a fire.
You should not expose any combustion
appliance directly to the air stream of the air­conditioner.
The appliance may then work inadequately.
–2–
Safety precautions
Do not wash the air-conditioner with water.
This could cause an electric shock.
The system should only be used for its original
purpose and not for anything else like, for in­stance, preservation of food, plants or animals, precision devices or works of art.
The system is only intended for use in ordinary domestic rooms. Any other use of the system may damage the quality of food, etc.
Do not place anything containing water, like
vases, on top of the unit.
Water entering the unit could damage the insulation and therefore cause an electric shock.
Do not install the system where the airflow di-
rection is aimed directly at plants or animals.
This will damage their health.
Do not sit on the outdoor unit nor put anything
on it.
If the unit falls down or things drop off it, people could get hurt.
After a long period of use, check the unit's
support structure from time to time.
If you do not repair any damage right away, the unit may fall down and cause personal injury.
CAUTION
Do not touch the aluminum fins on the air heat
exchanger.
It may result in injury.
Do not place household electrical appliances
or household items under neath the indoor or outdoor units.
Condensation falling from the unit may stain objects and cause accidents or electrical shock.
Do not operate the system without the air
filter.
It can cause malfunction of the system due to clogging of the heat exchanger.
Do not shut off the power supply immediately
after stopping the operation.
Wait at least 5 minutes, otherwise there is a risk of water leakage or breakdown.
Do not control the system with main power
switch.
It can cause fire or water leakage. In addition, the fan can start unexpectedly, which can cause personal injury.
If you operate the system together with a
combustion appliance, you must regularly ventilate the indoor air.
Insufficient ventilation may cause accidents due to oxygen deficiency.
Stand firmly on a stepladder or other stable
object when removing the inlet panel and filters.
Failure to observe this may result in injury through insecure objects toppling over.
When you clean the system, stop the unit
and turn off the power supply.
Never open the panel while the internal fan is rotating.
PRECAUTIONS FOR RELOCATION OR REPAIRS
Do not perform any repairs or modifications by yourself. Consult the dealer if the unit requires
repair.
If you repair or modify the unit, it can cause water leaks, electric shocks or fire.
Consult your dealer for repairs.
Wrong repairs could cause an electric shock, fire, etc.
In case the air-conditioner is relocated
elsewhere, contact your dealer or a profes­sional fitter.
Faulty installation may cause water leakage, electric shock, fire, etc.
If you notice anything abnormal (smell of burning, etc.), stop the system, turn off the power supply and consult your dealer.
Continued use of the system in abnormal circumstances may result in malfunctioning, electric shock, fire, etc.
Do not place objects near the outdoor unit or
allow leaves to gather around the unit.
If there are objects or leaves around the outdoor unit, small animals may enter unit and contact electrical parts and may cause a break-down, smoke or fire.
Contact your dealer to clean inside the
indoor unit, do not attempt to do by yourself.
The use of a non-approved detergent or im­proper washing method may damage the unit’s plastic components and cause leaks. Damage, smoke, or fire may also happen if the detergent comes in contact with electrical parts or the unit’s motor.
Stop the unit and turn off the power if you
hear thunder or there is a danger of lightning.
It may damage the unit.
DANGER
If the air-conditioner fails to cool or warm the
room, it may have a refrigerant leakage. Contact your dealer. If refrigerant needs to be added, check with your dealer for proper instructions.
If the refrigerant comes in contact with the bare skin, it may cause cold injury. If the refrigerant gas is inhaled excessively, it may cause deterioration of nerve function like dizzi­ness and headache, or deterioration of heart func­tion like irregular heartbeat and heart palpitation temporarily. If refrigerant unexpectedly leaks from the unit onto a fan heater, stove, hotplate or other heat source, harmful gases could be gener­ated.
–3–
Name of each part and its function
INDOOR UNIT
SRK63ZK-S SRK71ZK-S SRK80ZK-S
Draws in the indoor air. Page 16
Removes dust or dirt from the inlet air. Page 16
Air inlet panel
Indoor unit fan
Unit display section
Wireless remote control
Air-cleaning filter
Page 5
Air filter
OUTDOOR UNIT
Room temperature sensor
Unit operation switch
Air outlet
Air blows out of here.
Left/right air flow direction adjustment louver
Page 10
Up/down air flow direction adjustment flap
Page 10
Drain hose
Drains water from the indoor unit.
Refrigerant piping connection and electric wire
Air inlet
(On side & rear surface)
Air outlet
Outdoor unit fan
Heat exchanger
–4–
Name of each part and its function
Unit display section
Remote control signal receiver
Unit ON/OFF button
This button can be used for turning on/off the unit when remote control is not available.
Page 6
RUN (HOT KEEP) light (green)
Illuminates during operation.
Blinks when airflow stops due to the ‘HOT
KEEP’
and ‘CLEAN operation
HOT KEEP
CLEAN operation
Page 15
ON
OFF
ON
OFF
’.
1.5 sec.
0.5 sec.
3 sec.
1 sec.
Accessories
RUN TIMER ECONO
HI
POWER
ON
/
OFF
ECONO light (orange)
Illuminates during ECONOMY operation.
HI POWER light (green)
Illuminates during HIGH POWER operation.
TIMER light (yellow)
Illuminates during TIMER operation.
Wireless remote control
Wireless remote
control holder
NOTE
Buzzer sound for remote control
When preset temperature 24°C, automatic operation and automatic airflow are selected, the buzzer sound (PiPi) is produced. When turning off the air conditioner by pressing ON/OFF button (except CLEAN mode), the buzzer sound (Pi) is produced. This function is useful for operating the air conditioner in the darkness.
Air flow setting
Allergen clear filter
(Light orange)
Photocatalytic washable
deodorizing filter (Orange)
Preset temperature
–5–
Battery
(R03 (AAA, Micro) ×2)
Wood screw (Quantity:2)
(for remote control holder mounting)
Remote control handling
Replacing the batteries
The following cases signify exhausted batteries. Replace old batteries with new ones.
Receiving beep is not emitted when a signal is transmitted.
Display fades away.
NOTE
Pull out the cover and take
1
out old batteries.
Insert new batteries. R03 (AAA, Micro) x2
2
Close the cover.
3
Press the ACL switch with
4
the tip of a ballpoint pen.
Pay attention to the ª and · marks
Do not use old and new batteries together.
Remove the batteries when the remote control is not used for a long
period.
The recommended effective period of a battery conforming to JIS or IEC
should be 6 to 12 months with normal use. If used longer, or when an unspecified battery is used, liquid may leak from the battery, causing the remote control to malfunction.
The recommendable effective period is printed on the battery. This may be
shorter due to manufacturering time to the unit. However, the battery may still be in working order after expiry of its nominal life.
When the display shows any abnormal condition, Press the ACL switch with the tip of a ballpoint pen.
Using the remote control holder
The remote control can be attached to a wall or pillar by using a remote control holder. Before installing the remote control, check that the air-conditioner receives the signals properly.
For installing or removing the remote control, move it up or down in the holder.
Warning note for remote control handling
Strictly prohibited
Do not go near high temperature
places, such as an electric carpet or stove.
Do not put any obstructing obsta-
cles between the remote control and the unit.
Do not leave the remote control ex-
posed to direct sunlight or other strong lighting.
Do not spill any liquid on the
remote control.
Do not drop the remote control.
Handle with care.
Do not place heavy objects on the
remote control, or step on it.
Operation failure with the remote control
Are the batteries running down?
“Replacing the batteries” above.
Replace the batteries with new ones and retry the operation.
If the operation fails, operate the unit
with temporary operation function.
Contact your dealer to have the remote con­trol checked.
Temporary run operation
The unit ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.
Operation program
OPERATION MODE : AUTO
FAN SPEED : AUTO
AIR FLOW : AUTO
Operation starts by pressing the unit ON/OFF button; it stops if you press
the button again.
NOTE
Do not hold the Unit ON/OFF button down for more than 5 seconds.
(Holding it down longer than 5 seconds sets the automatic cooling used during servicing or when relocating the air-conditioner.)
Unit ON/OFF button
Below
–6–
Operation and display section for remote control
Operation section
FAN SPEED button
Each time the button is pressed, the display is switched over in turn.
Page 8
HI POWER/ECONO button
This button changes the HIGH POWER/ ECONOMY mode.
Page 14
ALLERGEN CLEAR button
This button selects ALLERGEN CLEAR operation.
Page 13
TEMPERATURE button
These button set the room temperature. (These buttons are used for setting the
current time and timer function as well.)
SLEEP button
This button selects SLEEP operation.
Page 11
CLEAN switch
This switch selects the CLEAN mode.
Page 15
ON TIMER button
This button selects ON TIMER operation.
Page 12
The above illustration shows all controls, but in
practice only the relevant parts are shown.
OPERATION MODE select button
Each time the button pressed, the display is switched over in turn.
ON/OFF (luminous) button
Press to start operation, press again to stop.
AIR FLOW (UP/DOWN) button
This button changes the air flow (up/ down) direction.
AIR FLOW (LEFT/RIGHT) button
This button changes the air flow (left/ right) direction.
CANCEL button
This button cancels the ON timer, OFF timer, and SLEEP operation.
OFF TIMER button
This button selects OFF TIMER operation.
ACL switch
Switch for resetting microcomputer.
TIME SET UP switch
This switch is for setting the time.
Page 8,9
Page 10
Page 10
Page 11
Page 6
Page 7
Transmission procedure
When each button on the remote control is pressed – with the remote control pointing towards the air-conditioner unit a signal is transmitted. When the air-conditioner receives the signal correctly, it will beep.
Current time setting
When inserting the batteries, the current time is automatically set to time setting mode. 13:00 is displayed as the current time. Set the clock to the right time.
Example: Set to 10:30.
Press the TIME SET UP switch.
1 2
3
Press with the tip of a ballpoint pen, etc. The time display blinks and can be set to the current time.
Press the “ or ” button.
(Set to 10:30)
Press the TIME SET UP switch.
The display changes from blinking to steady lighting and the setting is complete. Make sure to press the button within 60 seconds from the last operation in step 2, otherwise the time is not set.
NOTE
The timer operation works based on the time clock, so please set it
correctly.
The remote control data is reset when the present time is set.
–7–
AUTO mode operation
Automatically selects the operation mode (COOL, HEAT, DRY) depending on the room temperature when switched on.
When the unit is not in AUTO mode:
1
Press MODE button.
Move the [ mark] to the (Auto) position.
Point the remote control toward the air-conditioner, and
Press the ON/OFF button.
2
To stop: Press the ON/OFF button.
NOTE
In case air is not blowing out
during the operation.
Page 19
When the included clean filter is
installed the air conditioner will clean the air during automatic operation.
Display in OFF status
The current time and preset
OPERATION MODE are displayed while the air conditioner is turned off.
Temperature adjustment during AUTO
AUTO mode can be operated by simply pressing the ON/ OFF button.
If you do not want the AUTO mode program, change
to COOL, HEAT, DRY or FAN instead of AUTO.
Airflow direction adjustment procedure.
Page 9
Page 10
Air temperature adjustment is possible even during automatic operation. There are 6 levels of adjustment possible with the button or
button.During automatic operation, 24°C is preset both for heating and cooling.
the
FAN SPEED
You can choose the capacity of your air-conditioner when heating mode, cooling mode or fan mode.
Operation capacity by your choice FAN SPEED
Set automatically by microcomputer AUTO Powerful operation with high capacity HI
Standard operation MED Energy-saving operation LO Silent operation ULO
When a change in temperature is required.
Press the or button.
1
When it is a little cold
Press the
Each time the button is pressed, the switch over occurs in the following order
–6 –5 ............ –1 ±0 +1 ............ +6.
When +6 is indicated, even if the button is pressed, the indicator does not change.
When it is a little hot
Press the
Each time the button is pressed, the switch over occurs in the following order
+6 +5 ............ +1 ±0 –1 ............ –6.
When –6 is indicated, even if the button is pressed, the indicator does not change.
Setting temp.(°
button.
button.
-6 -5 -4 -3 -2 -1+0+1 +2+3 +4+5+6
C
)
18 19 20 21 22 23 24 25 26 27 28 29 30
Press the FAN SPEED button.
Move the [ mark] to the preferred fan speed position.
AUTO HI MED LO ULO
NOTE
When changing FAN SPEED from HI to LO, the sound
of refrigerant flowing may be heard.
Remote Control display
–8–
COOL/HEAT/DRY/FAN mode operation
Point the remote control toward the air-conditioner, and
Airflow direction adjustment procedure. Page 10
NOTE
In case air is not blown out, when starting the heating op-
eration.
Page19
The operation program can also be set or changed when
the air-conditioner is not in operation.
1
2 3
4
Press the MODE select button.
Move the [ mark] to the required operation position.
(Cool), (Heat), (Dry), (Fan)
Press the ON/OFF button.
Press the TEMP button.
Press or button for the preferred temperature.
Standard
Press the FAN SPEED button
Set the fan speed as preferred.
To stop: Press the ON/OFF button.
Air-conditioner operable temperature setting
Use within the following operational range. Operating outside of this range may result in the protection devices being activated, preventing the unit from working.
Outside temperature
Inside temperature
Inside humidity
Approximately -15 to 46 °C Approximately -15 to 21 °C
Approximately 18 to 32 °C Approximately 15 to 30 °C
Below approximately 80% The long-term use of the unit with a humidity level exceeding 80% may result in condensation forming on the surface of the indoor unit, leading to water drips.
Characteristics of HEAT mode operation
Mechanism and capacity of HEAT mode operation
Mechanism
The unit draws heat from the cold outside air, transfers it to indoors and heats the room. As a characteristic of heat pump system, the
heating capacity reduces when the outside air temperature gets colder.
It may take some time to supply hot air after turning on the air-conditioner.
If the outside temperature becomes extremely low, it would be better to use an additional source of heating.
Defrosting
If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents efficient heating.
If this happens, the automatic defrost function is activated and during defrosting the heating operation stops for 5 to 15 minutes during defrosting.
Both indoor and outdoor fans stop and the RUN light blinks slowly (1.5 sec. ON, 0.5 sec. OFF) during defrosting.
The outdoor unit may give off some steam during defrosting. This is to help the defrosting process and is not a defect.
The HEAT operation resumes as soon as defrosting has been completed.
Cooling operation Heating operation
–9–
Airflow direction adjustment
Adjusting airflow direction
Up/down direction can be adjusted with the AIRFLOW (UP/DOWN) button on the remote control. Every time you press this button the mode changes as follows:
Change on AIRFLOW (UP/DOWN) mode.
(Flap stopped)
(Swing)
Left/right direction can be adjusted with the AIRFLOW button the mode changes as follows:
Change on AIRFLOW (LEFT/RIGHT) mode.
NOTE
The actual position of the flap and louver may differ from the display shown.
NOTE FOR HEATING OPERATION
When operation starts, the flap and louver direction is fixed at the horizontal / center position in order to avoid cold draft, and return
to the set the position that was set after the warm air supply is starting.
The flap and louver direction will be controlled to the horizontal/center position when the room temperature reaches the set tem-
perature and compressor stops or when defrosting is in operation.
The airflow direction cannot be set during the period mentioned above. Change the airflow direction settings after the warm air is
supplied and the flap/louver goes to the set position.
(LEFT/RIGHT) button on the remote control. Every time you press this
(Louver stopped)
(Swing)
MEMORY FLAP (FLAP OR LOUVER STOPPED)
When you press the AIRFLOW (UP/DOWN or LEFT/RIGHT) button once while the flap or louver is operating, it stops swinging at the position. Since this angle is memorized in the microcomputer, the flap or louver will automatically be set at this angle when the next opera­tion is started.
Do not expose directory to airflow from the air-conditioner for a long time.
When in COOL or DRY operation, do not operate for a long period with the
airflow blowing straight down. Otherwise, condensation may appear on the outlet grill and drip down.
Do not try to adjust the flaps and louvers by hand, as the control angle may
change or the flap or louver may not be closed completely.
DANGER
CAUTION
Recommended angle of the flap when
stopping
HEAT
COOL, DRY
(Slant forward
blowing)
(Horizontal
blowing)
Multi-directional Air Flow (up/down air scroll and left/right air scroll)
Activating both up/down air swing and left/right air swing at the same time results in a multi-directional air flow.
Up/down air scroll Left/right air scroll
In COOL, DRY and FAN operation In HEAT operation In COOL, DRY and FAN operation In HEAT operation
Stops at this position for 5 seconds.
Thick line : moves quickly Thin line
: moves slowly
Stops at this position for 5 seconds.
Left louver Right louver
–10–
SLEEP TIMER operation
(
)
The unit stops automatically after the set time lapses. The set temperature is automatically adjusted according to the elapsed time in order to avoid too much cooling or heating.
Page 13
1
Changing of set time
Set a new time by pressing SLEEP button.
How to cancel
Press the CANCEL button to turn off the SLEEP indicator.
1
Press the SLEEP button.
If it is pressed while the unit is off
SLEEP TIMER operation starts with the previous operation settings, and the air conditioning is turned off after the set time elapses.
If it is pressed while the unit is running
The air conditioner is turned off after the set time elapses. Every time the button is pressed, the display changes as follows:
...
(Units of one hour)
No indication
cancelled
Example: You prefer it to stop after 7 hours.
Set to
The timer light (yellow) is on.
The unit stops after the set time lapses.
SLEEP operation will not function during ALLERGEN CLEAR operation.
Cannot be set at the same time with OFF-TIMER.
h
NOTE
OFF-TIMER operation
The unit stops automatically when the set time comes. With the air conditioner turned off, start the operation from Step 1. With the air conditioner running, start from Step 2.
Changing of set time
Set a new time by using the OFF-TIMER button.
How to cancel
Press the CANCEL button to turn off the timer display.
Example: You prefer it to stop 22:30.
1 2 3
4
Press the ON/OFF button.
Press the OFF-TIMER button.
OFF TIMER display is blinking.
Press the “ or ” button.
Every time the button is pressed, the display is switched in the order of:
0:00 0:10 0:20
Every time the button is pressed, the display is switched in the order of:
0:00 23:50 23:40
Set at 22:30.
Press the OFF-TIMER button.
The display changes from blinking to steady lighting and the setting is complete. The timer light (yellow) is on.
NOTE
The unit stops at the end of the set period of time.
Make sure to press the button within 60 seconds from the last operation in step 3, otherwise the setting is not completed.
The current time is not displayed during OFF-TIMER operation.
OFF-TIMER operation will not function during ALLERGEN CLEAR operation.
Different from SLEEP TIMER operation, automatic set temperature adjustment is not done during OFF-TIMER operation.
–11–
...
...
1:00 1:10
23:00 22:50
(Units of ten minutes)
(Units of ten minutes)
ON-TIMER operation
Operation starts 5 to 60 minutes before the set time so that the room temperature reaches the optimum temperature at the set time. ON-TIMER operation can be set regardless of whether the air-conditioner is running or not.
Example: In the case the preferred room temperature is required at 8:00.
Press the ON-TIMER button.
1 2
3
ON-TIMER display is blinking.
Press the “ or ” button.
Every time the button is pressed, the display is switched in the order of:
0:00 0:10 0:20
Every time the button is pressed, the display is switched in the order of:
0:00 23:50 23:40
Set at 8:00.
Press the ON-TIMER button.
The display changes from blinking to steady lighting and the setting is complete. The timer light (yellow) is on. The operation stops if it is set during operation.
NOTE
...
...
1:00 1:10
23:00 22:50
(Units of ten minutes)
(Units of ten minutes)
Page 13
Changing of set time
Set a new time by using the ON-TIMER button.
How to cancel
Press the CANCEL button to turn off the timer indicator.
Operation starts 5 to 60 minutes before the set time.
The timer light (yellow) goes out at the set time.
Make sure to press the button within 60 seconds from the last opera-
tion in step 2, otherwise the setting is not completed.
The current time is not displayed during ON-TIMER operation.
ON-TIMER operation will not function during ALLERGEN CLEAR
operation.
SLEEP TIMER + ON-TIMER operation
Combined timer operation of SLEEP TIMER and ON-TIMER.
Example: When it is required to stop after 3 hours and then start operation at
8:00, near the set temperature.
SLEEP TIMER setting
Set by the procedures on page 11.
Set to
ON TIMER operation setting
Set by the above procedure mentioned in ON-TIMER.
Set to
The setting of the lighting of the timer light (yellow) of this unit is com­plete.
h
After the SLEEP TIMER set time has elapsed, the operation stops, and
it starts from 5 to 60 minutes before the ON-TIMER’s set time.
The timer light is turned off when ON-TIMER set time comes.
Changing of set time
Set a new time by using the SLEEP or ON-TIMER button.
How to cancel
Press the CANCEL button to turn off the timer display.
–12–
PROGRAM TIMER operation
The timer operations of the combination of ON and OFF TIMER. Once this has been set the timer operations will be repeated at the same time every day unless the ON/OFF button is pressed.
Example: When it is prefered to stop at 22:30, and then start operation at 8:00,
near the set temperature.
OFF-TIMER operation setting
Set by the procedures on page 11. Set to
ON-TIMER operation setting
Set by the procedures on page 12. Set to
Timer light (yellow) on the unit will light when the setting is completed.
The set time will be displayed on the remote control unit. The display will change depending on the operational status.
With ON-TIMER, the air conditioner starts running. Then, with OFF-TIMER, the air conditioner stops run­ning.
With OFF-TIMER, the air conditioner stops running. Then, with ON-TIMER, the air conditioner starts run­ning.
Changing of set time
Set a new time by using the OFF-TIMER or ON-TIMER button.
How to cancel
Press the CANCEL button to turn off the timer display.
Comfort Start-up
In ON-TIMER operation, the unit starts the operation a little earlier, so that the room can approach optimum temperature at ON time. This is so called “Comfort start-up”.
Mechanism
The room temperature is checked 60 minutes before the ON time. Depending on the temperature at that time, the operation starts 5 to 60 minutes before the timer is at ON.
The function is available for
both COOL and HEAT opera­tion mode (including AUTO). It does not work for DRY mode.
In COOL operation
(Stop) Operation starts
Set temperature
Check the room temp. 60 mins. before.
(Operation)
Set time
When SLEEP TIMER is selected, the set temperature is automatically adjusted after a while, ensuring that the room is not too cold during cooling or too warm during heating.
During cooling : the preset temperature is lowered by 1°C at the start
of SLEEP operation (when the timer is set). After that, the tempera­ture goes up by 1°C every an hour to become 1°C higher than the present temperature.
During heating: Preset temperature is lowered by 1°C at the start of
SLEEP operation (when the timer is set). After that the temperature to becomes 3°C lower in an hour and 6°C lower in two hours than the present temperature.
ALLERGEN CLEAR operation
The power of enzymes is used to eliminate allergy-causing allergens that accu­mulate on the allergen clear filter.
Aim the remote control at the air-conditioner.
1
Press the ALLERGEN CLEAR button.
To stop:
NOTE
SLEEP TIMER
Press the ON/OFF or ALLERGEN CLEAR button.
Since the room temperature may change quite a bit, it is recommended
that this be used when no one is in the room. (It completes automati­cally in approximately 90 min.)
During ALLERGEN CLEAR operation temperature, fan speed, airflow
direction and timer operations settings cannot be made.
–13–
HIGH POWER/ECONOMY operation
If the air-conditioner is not operating, point the remote control toward the air conditioner, and
1
Press the ON/OFF button.
Press the HI POWER/ECONO button.
2
When the operating mode is AUTO, COOL or HEAT
Every time the HI POWER/ECONO button is pressed, the display is switched in the order of:
(
HIGH POWER
When the operating mode is DRY or PROGRAM TIMER
Every time the HI POWER/ECONO button is pressed, the display is switched in the order of:
ECONOMY
(
)(
ECONOMY
) (Normal operation)
Concerning HIGH POWER operation
Pressing the HI POWER/ECONO button intensifies the operating power and initiates powerful cooling or heating operation for 15 minutes continuously. The remote control
NOTE
During the HIGH POWER operation, the room temperature
is not controlled. When it causes an excessive cooling or heating,press the HI POWER/ECONO button again to cancel the HIGH POWER operation.
HIGH POWER operation is not available during the DRY
and the program timer operations.
When HIGH POWER operation is set after ON TIMER
operation, HIGH POWER operation will start from the set time.
displays and the FAN SPEED display disappears.
When the following operations are set, HIGH POWER
operation will be canceled.
1 When the HI POWER/ECONO button is pressed again. 2 When the operation mode is changed. 3 When it has been 15 min. since HIGH POWER
operation has started.
Not operable while the air conditioner is OFF.
After HI POWER operation, the sound of refrigerant flowing
may be heard.
No display
) (Normal operation)
No display
Concerning ECONOMY operation
Pressing the HI POWER/ECONO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating. The unit operates 1.5°C higher than the setting temperature during cooling or 2.5°C lower than that during heating. The
remote control
NOTE
It will go into ECONOMY operation at the next time the air-
conditioner runs in the following case.
When the air-conditioner is stopped by ON/OFF button
1
during ECONOMY operation.
2
When the air-conditioner is stopped in SLEEP or OFF
TIMER operation during ECONOMY operation.
3 When the operation is retrieved from CLEAN or AL-
LERGEN CLEAR operation.
displays and the FAN SPEED display disappears.
When the following operations are set, ECONOMY operation
will be canceled.
1 When the HI POWER/ECONO button is pressed
again.
2 When the operation mode is changed DRY to FAN.
Not operable while the air conditioner is OFF.
–14–
SELF CLEAN operation
CLEAN operation should be run after AUTO, COOL and DRY operation to remove the moisture from inside the indoor unit and control the growth of mold and bacteria.
In order to active CLEAN operation, press the CLEAN
1
Two hours later, the air conditioner stops running automatically. To stop
CLEAN operation is not operated after HEAT and FAN, OFF-TIMER,
The indoor unit fan runs for about two hours in CLEAN operation.
The RUN light illuminates during CLEAN operation.
Pressing the SLEEP button or ALLERGEN CLEAR button during
This is not a function for removing mold, germs or grime that have
switch with the tip of a ballpoint pen.
Every time the CLEAN switch is pressed, the display is switched in the order of:
(CLEAN on) (CLEAN off)
NOTE
the air conditioner immediately, press the ON/OFF button.
SLEEP and ALLERGEN CLEAR operations have finished.
ON
OFF
CLEAN operation cancels the CLEAN operation and then the unit is set to SLEEP or ALLERGEN CLEAR operation.
already adhered to the unit.
No display
3 sec.
1 sec.
Auto restart function
What is auto restart function?
Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a power cut, and then automatically resumes operations after the power has been restored.
The following settings will be cancelled:
1 Timer settings 2 HIGH POWER operations
NOTE
Auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs
to be switched off.
When power failure occurs, the timer setting is cancelled. Once power is resumed, set the timer again.
Tips for effective operation
Please observe the following for the most economic and comfortable use of your unit.
Set a suitable room temperature.
Excessively high or low temperatures are not good for your health and waste of electricity.
Adjust the airflow direction properly.
Adjust the up/down and left/right airflow to ensure a steady room temperature.
Clean the filters frequently.
Clogged filters may block the airflow and cause less efficient operation.
Operate the unit only when needed.
Use the timer properly to operate the unit only when needed.
Avoid direct sunlight and draught.
Cut out direct sunlight by drawing the curtains or blinds when cooling. Keep windows and doors shut, except when ventilating.
Keep heat source away when cooling.
Keep heat sources out of the room as much as possible.
–15–
Maintenance
Before maintenance
Turn off the power supply.
Do not spill any liquid.
There's a dan­ger of electric shock.
Wipe the unit with a soft, dry cloth.
Do not touch the aluminum fins on
the heat exchanger.
Stand firmly on a stepladder or other
stable object when removing the inlet panel and filter.
Do not use the following articles:
Hot water (40°C or more)
It may deform or discolour the unit.
Petrol, paint thinner, benzine or cleanser, etc.
They may deform or scratch the unit.
During the operational season
Cleaning the air filter
Remove the air filter
1
Cleaning
2
Do not clean the filters with boiling water.
Do not dry them over an open flame.
Pull them out gently.
Reinstall the air filter
3
Hold firmly the filter at both sides as shown at
right and insert securely.
Operating without putting back the air filters will
make the unit dusty, and may cause damage.
Cleaning the unit
Wipe the unit with a soft, dry cloth, or use a vacuum cleaner.
If the unit is very dirty, wipe it with a cloth soaked in warm water.
Cleaning the air inlet panel
Removal, installation of air inlet panel.
The panel can be washed with water. After
washing with water, wipe any moisture off the panel and dry out of direct sunlight.
If the filter is very dirty, clean it with warm water (approx. 30°C), and dry it thoroughly.
CAUTION
Standard interval is once every two week
Pull up the air inlet panel forward.
Lightly hold the knobs both sides and lift
a little to remove the panel forward.
How to open, close the air inlet panel
Open
Place fingers at the recesses on both sides of the panel and pull up the panel forward so that it will be open by about 60 degrees.
Removal, installation of air inlet panel
Removal
When removing the air inlet panel for internal cleaning or others, open the panel by 80 degrees and then pull it forward.
Close
Push both ends evenly and press further lightly at the center.
Installation
Secure the upper edge of the air inlet panel by lightly pushing it in, and then close the panel.
–16–
NOTE
Cooling/heating is affected by an air filter clogged up with dust etc., and the operation noise becomes louder. It may also use extra electricity. Please clean the air filter at appropriate intervals.
At the end of the season
Perform the fan operation for 2 to 3 hours.
1
Dry the inside of the unit.
Stop the unit and turn off the power supply.
2
The unit consumes approx. 4W even when the unit is not operat­ing.
Turning off the power supply will help saving energy consumption
and cost.
Clean and reinstall the air filters.
3
Clean both the indoor and outdoor units.
4
Remove batteries from the remote control.
5
Installing, inspecting, and replacing the air-cleaning filter
1. Open the air inlet panel and remove the air filters. Page 16
2. Remove the filter holders, with the air-cleaning filter installed in the folders, from the air-conditioner.
3. Remove the allergen clear filter (Light orange) from filter holder and inspect the filter. Use a vacuum cleaner to remove any dust or dirt from the allergen clear filter. Replace the allergen clear filter if it cannot be cleaned or if it has been for about 1 year. (The allergen clear filter should be replaced after about 1 year of use. However, the actual replacement period may vary depending on the conditions in which the filter is used.)
Remove the photocatalytic washable deodorizing filter (orange) from the filter holder and inspect the filter. Periodically, remove any dust or dirt from the photo­catalytic washable deodorizing filter. If the photocatalytic washable deodorizing fil­ter is particularly dirt, it may be washed with water. However, the filter is fragile so be sure to wash it installed in the filter holder to avoid damaging it. After washing the filter, place it in sunlight to dry. Placing the filter in sunlight revitalizes the deo­dorizing effect.
At the beginning of the season
Ensure that the earth wiring is not snapped
1
nor disconnected.
Check if there is no corrosion or rust on the
2
base frame of the outdoor unit.
Make sure that there are no obstacles block-
3
ing the airflow around the air intake and outlet openings of the indoor and outdoor units.
Ensure that the air filters are clean.
4
Turn on the power supply.
5
Insert batteries in the remote control.
6
Filter holder
(Do not dispose of the filter holders. They are reusable. )
4. Install the air-cleaning filter in the filter holders, and then install the filter holders in the air-conditioner.
NOTE
The allergen clear filter and the photocatalytic washable deodorizing filter
may be installed on either the right or left side of the air-conditioner.
Install the allergen clear filter with the light orange side front.
5. Install the air filters and closed the air inlet panel.
CAUTION
The heat exchanger may injure your fingers.
For replacement the air-cleaning filter, contact your dealer.
Item Feature Color
Allergen clear filter
Photocatalytic washable deodorizing filter
The power of enzyme is used to eliminate allergy-caus­ing allergens that accumulate on the filter.
Sources of odors on the filter are broken up, resulting in a deodorizing effect.
Filter
Page 16
Light orange
Orange
–17–
Proper installation
Suitable installation position
Do not put any obstruction in front of the indoor unit, preventing proper ventilation and functioning.
Do not install the unit in any of the following places:
Where there is a danger of leaking flammable gases.
Where there is substantial splashing of oil.
Malfunctioning due to corrosion may occur if the unit is installed in a spa where sulfide gases are generated, or in a seaside resort
exposed to sea breezes. Contact your dealer.
The air-conditioner and remote control must be at least 1 metre away from a TV set or radio.
Drain the dehumidified liquid from the indoor unit into a spot that drains well.
Pay attention to operating noises!
• When you install the unit, take care to choose a place that can comfortably stand the weight of the unit and does not increase the operating noise or vibration. If vibration is transmitted through the house, fix the unit with the aid of vibration-proof pads between the unit and the fittings.
• Select a place where cold or hot air, operation noises from the indoor and outdoor units do not cause any inconvenience to your neighbours.
• Do not leave any obstacles near the outlet and inlet of the outdoor unit. This may cause malfunctioning and increased operating noise.
• If you hear an irregular noise during operation, contact your dealer.
Inspection and maintenance
Depending on operating environment, the inside of the air-conditioner may become dirty after a few year operations. This will reduce performance. In addition to normal cleaning, we would recommend inspection and maintenance. (This may lead the air-conditioner to having a longer life without any trouble.)
• Contact your dealer, or any distributor, for inspection and maintenance. (There will be a charge for this service).
• We would recommend inspection and maintenance to be carried out during the off-season.
• If the supply cord of this appliance is damaged, it must only be replaced by a repair shop appointed by the manufacturer, because special purpose tools are required.
Troubleshooting
Please carry out the following checks before making a service call.
The air-conditioner does not work at all.
Has the power switch been turned off?
Have you set the thermostat at a suitable temperature?
suitable
tempera-
ture
Is there any direct sunlight entering the room?
Has the timer been set in the “ON” position?
Poor cooling or heating
Is the air filter clean? (Not clogged?)
Poor cooling
Is there a heat source in the room?
Is there a power failure or a blown fuse?
Did you leave any doors or windows open?
Are there too many people in the room?
If the air-conditioner does not op­erate properly after you have checked the left points, or if any doubt still exists after you have consulted page 19, or if things happen as shown on page 20, switch off the power and contact your dealer.
An alternative refrigerant (R410A) is used in this air-conditioner. When asking your dealer for service or inspection and maintenance, explain the dealer about it.
–18–
Notice
The unit does not restart immediately after you have stopped it.
(RUN light is on)
Not
operating?
Airflow is not blown out when starting the HEATING opera­tion.
RUN light blinks slowly
(1.5 sec ON, 0.5 sec OFF)
Airflow is not blown out for 5 to 10 min. or blown out not warm wind for a moment at HEATING operation.
RUN light blinks slowly
(1.5 sec ON, 0.5 sec OFF)
Airflow is not blown out when starting the DRY operation.
(RUN light is on)
Some steam escapes during COOL operation.
There is a slight smell.
Restart is blocked for 3 minutes after you have stopped the op­eration to protect the unit.
Please wait for three minutes.
The three-minute protection timer in the microcomputer auto­matically starts it up again.
Airflow has stopped to prevent blowing out of cold air until the indoor heat exchanger has warmed up. (2 to 5 min.) (HOT KEEP program)
When outdoor temperature is low and humidity is high, the unit sometimes performs defrosting automatically. Please wait. Dur­ing defrosting, water or steam may escape from the outdoor unit.
The indoor fan may stop to prevent re-evaporation of dehumified moisture and to save energy.
This may occur if the room's temperature and humidity are very high. It disappears as soon as the temperature and humidity decrease.
Air blown out during operation may smell. This is caused by tobacco or cosmetics adhering to the unit.
You hear a slight gurgling sound.
You hear a slight cracking sound.
You hear a hissing or clicking sound.
After a power cut, the unit does not restart even if power has been restored.
Remote control signals are not received.
Moisture may form on the air outlet grills.
Whistling noise is heard from the outdoor unit.
Fan will not stop immediately after unit operation was stopped.
RUN light stays on even though operation was stopped.
This is caused by refrigerating liquid moving within the unit.
This is caused by heat expansion or contraction.
This is caused by the operation of the refrigerant control valves or electric components.
If the auto restart function is not set, the unit will not restart automatically. Use the remote control to start the operation again.
Remote control signals may not be received if the signal receiver on the air-conditioner is exposed to direct sunlight or other bright light. If so, cut out the sunlight or reduce the other light.
If the unit is operated for a long time in high humidity, moisture may form on the air outlet grills and start dripping.
The noise means that the revolution speed of the compressor is increasing or decreasing.
Indoor fan : Fan will not stop after 2 hours if set to CLEAN
operation.
Outdoor fan : Fan will not stop about a 1 minute period in
order to protect the unit.
The RUN light illuminates during CLEAN operation. Run light turns off when CLEAN operation ends.
Sometimes a “Shooooo” sound might come for a short time from the unit that is turned off.
This is the sound when operation of another indoor unit is stopped.
–19–
Contact your dealer
Turn off the power switch immediately and inform your dealer in any of the following situations:
The fuse or switch blows continu­ously.
Fuse often blows.
The TV, radio or other equipment starts to malfunction.
When abnormalities occur, turn off the power supply immediately and turn it on after 3 minutes. Restart the operation with ON/OFF button of the remote control and the abnormalities still continue.
The cable becomes extremely hot. The covering of the cable is cracked.
CAUTION
If the power cord becomes damaged, ask your dealer or a qualified engineer to install the replacement to avoid accidents.
A switch does not activate properly. You hear a strange noise during
operation.
The RUN and TIMER lights on the unit display section blink quickly (0.5 sec. ON; 0.5 sec. OFF) and do not work.
About the Multiple Air-conditioner
Simultaneous Operation
• The air-conditioners cannot be in different operating modes at the same time, such as one unit being in the “Cool” mode and one unit being in the “Heat” mode.
• When conducting different operations, the air-conditioner that was operated first will be given priority, so the air-conditioner that is operated after that will conduct air blowing operation.
• When you want to give priority to the air-conditioner that was started later, either stop the air-conditioner that has priority or cause the operation type of the unit operated first to match that of the unit operated second.
Automatic Operation
• When the remote control operation switch is in the “Auto” mode the air-conditioner automatically selects either “Cool,” “Dry,” or “Heat” when operation is started depending on the room temperature.
• During simultaneous operation of air-conditioner units, operation modes may be automatically changed in response to the tem­peratures of the individual rooms; this will result in the operation of the outdoor unit being stopped. In such a case, COOL or HEAT mode should be used instead of AUTO. (This is only relevant when more than one air-conditioner unit is being used.)
Refrigerant (oil) recovery operation
• If the all of the indoor units are not operated at the same time for an extended period, the cooling or heating performance may temporarily decrease. This is in order to control the recovery of the refrigerant (oil) in the stopped indoor unit(s). At this time, the sound of refrigerant flowing may be heard from the stopped indoor unit(s).
–20–
Self diagnosis function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of each function as follows:
TIMER light ON
RUN light keeps flashing
RUN light
1 time flash
2 time flash
3 time flash
5 time flash
6 time flash
7 time flash
TIMER light
1 time flash
2 time flash
4 time flash
5 time flash
Description of trouble
Heat exchanger sensor 1 error
Room temperature sensor error
Heat exchanger sensor 3 error
Active filter voltage error
Indoor fan motor error
Refrigerant is insufficient Closed service valve Heat exchanger sensor 1 error
Outdoor temperature sensor error • Broken outdoor sensor wire, poor connector connection
Outdoor heat exchanger fluid pipe sensor error
Discharge pipe sensor error
Suction pipe sensor error Broken suction pipe sensor wire, poor connector connection
Broken heat exchanger sensor 1 wire, poor connector connection
Broken room temperature sensor wire, poor connector
connection
Broken heat exchanger sensor 3 wire, poor connector connection
Defective power supply
Defective fan motor, poor connector connection
Refrigerant is insufficient, leaking
Closed serice valve
Broken heat exchanger sensor 1 wire, poor connector
connection
Broken heat exchanger fluid pipe sensor wire, poor connector connection
Broken discharge pipe sensor wire, poor connector connection.
Cause
RUN light ON
RUN light 2 time flash
1 time flash
2 time flash
3 time flash
4 time flash
5 time flash
6 time flash
7 time flash
Keep flashing
2 time flash
Current cut
Trouble of outdoor unit
Over current
Power transistor error
Over heat of compressor
Error of signal transmission
Outdoor fan motor error Defective fan motor, poor connector connection
Cooling high pressure protection Gas over charge, short circuit of outdoor unit
Rotor lock
Compressor locking, open phase on compressor output, shortcircuit on power transistor, closed service valve
Broken power transistor, broken compressor wire
Broken discharge pipe sensor wire, poor connector connection
Compressor blockage
Overload operation, overcharge
Broken power transistor
Gas shortage, defective discharge pipe sensor, closed service valve
Defective power supply, Broken signal wire, defective
in/outdoor unit boards
Defective compressor
Open phase on compressor
Defective outdoor unit boards
–21–
–22–
Nous vous remercions d’avoir choisi un climatiseur MITSUBISHI HEAVY INDUSTRIES, LTD. Pour obtenir des performances optimales et durables, veuillez lire attentivement et respecter les instructions du présent manuel d’utilisateur avant d'utiliser votre climatiseur. Reportez-vous au manuel si vous avez des questions ou en cas de dysfonctionnement.
Ce climatiseur est à usage domestique.
Ne laissez pas sortir du R410A dans l’atmosphère: Le R410A est un gaz à effet de serre fluoré, à Potentiel de Réchauffement Global (PRG, GWP Global Warming Potential) = 1975 selon le Protocole de Kyoto.
Votre unité de climatisation peut comporter ce symbole, qui signifie que les déchets d’équipements électriques et électroniques (DEEE selon la directive 2002/96/CE) ne doivent pas être jetés aux ordures ménagères générales.Les climatiseurs doivent être réusinés dans un établissement autorisé, en vue de leurs réutilisation, recyclage et récupération, et non pas être éliminés dans une décharge municipale. Pour de plus amples renseignements à ce sujet, veuillez communiquer avec l’installateur ou l’autorité municipale.
Ce symbole, imprimé sur les piles insérées dans votre appareil de climatisation, est une information destinée à l’utilisateur final, selon la Directive 2006/66/CE Article 20 Annexe II de l’UE. Les piles usées ne doivent pas être jetées avec les déchets domestiques. Si un symbole chimique est imprimé à côté du symbole indiqué ci-dessus, cela signifie que les piles contiennent une certaine concentration de métal lourd. Ceci est indiqué de la façon suivante: Hg: mercure (0,0005%), Cd: cadmium (0,002%), Pb: plomb (0,004%) Veuillez déposer les piles à l’endroit préconisé dans votre déchetterie locale ou dans un centre de recyclage.
FRANÇAIS
Le niveau d’émission sonore dû à la pression des appareils extérieur et intérieur est inférieur à 70 dB(A).
table des matières
Consignes de sécurité.......................... 24
Description des éléments et
leurs fonctions ...................................... 26
Mode d’emploi de la télécommande .... 28
Panne de la télécommande ................. 28
Fonction de secours ............................. 28
Fonctionnement et affichage de la télé-
commande ........................................... 29
Réglage de l’heure actuelle.................. 29
Mode de fonctionnement AUTO........... 30
Réglage de la température en
mode AUTO ......................................... 30
FAN SPEED
(VITESSE DE VENTILATION) ............. 30
Mode de fonctionnement
COOL/HEAT/DRY/FAN........................ 31
Réglage de la température de
fonctionnement du climatiseur ............. 31
Particularités du mode de
fonctionnement HEAT .......................... 31
Réglage de l’orientation du flux d’air .... 32
Fonction SLEEP TIMER....................... 33
Fonction OFF-TIMER ........................... 33
Fonction ON-TIMER............................. 34
Fonctions SLEEP TIMER +
ON-TIMER ........................................... 34
Fonction PROGRAM TIMER................ 35
Fonction ALLERGEN CLEAR .............. 35
Fonction HIGH POWER/ECONOMY ... 36
Fonction SELF CLEAN ........................ 37
Fonction de redémarrage
automatique ......................................... 37
Conseils d’utilisation............................. 37
Entretien et maintenance ..................... 38
Procédure d’installation ........................ 40
Que faire avant d’appeler l’installateur/
le service après-vente .......................... 40
À savoir ................................................ 41
Contactez votre revendeur ................... 42
Climatiseurs multiples .......................... 42
Fonction auto-diagnostic ...................... 43
–23–
Consignes de sécurité
Avant de mettre en route le système, veuillez lire attentivement les « Consignes de sécurité » pour le bon fonctionne-
ment de l’appareil.
Après avoir lu ce manuel d’instructions, conservez-le afin de pouvoir vous y référer ultérieurement. Si l’opérateur est
remplacé, assurez-vous de remettre ce manuel au nouvel opérateur.
DANGER
PRUDENCE
Assurez-vous d’observer strictement ces consignes de sécurité, parce qu’elles constituent des informations très im­portantes en matière de sécurité.
Les symboles que l’on rencontre souvent dans le texte ont les significations suivantes :
Interdiction totale
CONSIGNES DE SÉCURITÉ POUR L’INSTALLATION
Ce système est destiné à un usage domestique.
S’il est utilisé dans des environnements difficiles, tels que des milieux techniques, les performances du système peuvent en être fortement altérées.
L’appareillage doit être installé par votre concessionnaire ou par un installateur professionnel.
Il n’est pas recommandé d’installer le système par vous-même dans la mesure où une mauvaise manipulation peut provoquer une fuite d’eau, un choc électrique ou un incendie.
Une mauvaise manipulation pourrait avoir de sérieuses conséquences telles que des blessures fatales, graves, etc.
Pourraient également entraîner de graves problèmes selon les circonstances.
Respectez les instructions consciencieusement
Assurer une mise à la terre adéquate
DANGER
PRUDENCE
Ne pas l’installer dans un endroit présentant un risque de fuite de gaz inflammable.
Des fuites de gaz se propagent: risque d’incendie.
Selon l’emplacement choisi de l’installation,
un disjoncteur de mise à la terre peut s’avé­rer nécessaire.
Si vous n’installez pas de disjoncteur de mise à la terre, vous vous exposez à un risque de choc électrique.
Assurez une bonne mise à la terre.
Le câble de terre ne doit jamais être branché à un tuyau de gaz, à une conduite d’eau, à un paratonnerre ou un à câble téléphonique. Risque de décharges électriques en cas de mauvaise installation.
Veiller à installer correctement le tuyau
d’écoulement de sorte que toute l’eau puisse être purgée.
Une mauvaise installation peut entraîner la chute de gouttes d’eau dans la pièce et endommager ainsi les meubles par cette humidification.
CONSIGNES DE SÉCURITÉ POUR L’UTILISATION
DANGER
Évitez de vous exposer au courant d’air froid
pendant une durée prolongée.
Cela pourrait avoir une influence sur votre condition physique, ou causer des problèmes de santé.
Rangez la télécommande hors de la portée des jeunes enfants.
Vous éviterez ainsi qu’ils n’avalent les piles et tout autre accident.
N’insérez rien dans la grille d’arrivée d’air.
Vu que le ventilateur interne tourne à grande vitesse, vous pourriez vous blesser.
N’utilisez que des fusibles approuvés.
Il est strictement interdit d’utiliser un fil de fer ou de cuivre à la place d’un fusible approuvé, afin d’éviter tout risque d’incident de fonction­nement ou d’incendie.
Ne manipulez pas les interrupteurs avec les
mains mouillées.
Risque de décharges électriques.
Ne vous suspendez pas à l’appareil.
Si l’unité d’intérieur tombe, vous pouvez vous faire mal.
PRUDENCE
Ne placez pas d’insecticide inflammable ni de
pulvérisateur de peinture près du souffleur et ne les vaporisez pas directement sur le sys­tème.
Risque d’incendie.
Les appareils à combustion ne doivent pas
être placés à proximité d’une sortie du climatiseur.
Risque de combustion insuffisante de l’appa­reil.
–24–
Consignes de sécurité
Ne lavez pas le climatiseur avec de l’eau.
Risque de décharges électriques.
Il ne faut jamais utiliser l’appareil à d’autres fins
que celles prévues, par exemple pour la conserva­tion d’aliments, pour des plantes ou des animaux, des dispositifs de précision ou oeuvres d’art.
L’appareil ne doit être utilisé que pour des piè­ces ordinaires. D’autres applications peuvent endommager la qualité des aliments, etc.
Ne mettez pas de vase ou autre objet conte-
nant de l’eau sur le dispositif.
Si l’eau pénètre dans l’appareil, l’isolation électrique risque d’être détériorée. Risque de décharges électriques.
Installez le système de sorte que le flux d’air
ne soit pas directement orienté vers des plantes ou des animaux.
Ce n’est pas bon pour leur santé.
Ne vous asseyez pas ou ne posez rien sur le
dispositif extérieur.
Si le dispositif ou les objets entreposés tom­bent, des personnes pourraient se blesser.
Vérifiez de temps en temps l’état du support
du dispositif lorsque l’installation est an­cienne.
Si vous ne réparez pas immédiatement une
Lorsque l’appareil marche en même temps
qu’un appareil à combustion, l’air de la pièce doit être ventilé fréquemment.
Une ventilation insuffisante peut provoquer un accident par manque d’oxygène.
Utilisez un escabeau ou autre objet stable
pour atteindre et retirer le panneau d’arrivée d’air ou les filtres.
Un objet instable pourrait s’écrouler et par conséquent vous risqueriez de vous blesser.
Lorsque vous procédez au nettoyage du
système, arrêtez l’appareil et mettez-le hors tension.
N’ouvrez jamais le panneau lorsque le ventila­teur intérieur tourne.
Ne posez rien près du dispositif extérieur et
veillez à ce qu’il n’y ait pas d’amoncellement de feuilles tout autour.
PRUDENCE
panne, l’appareil peut tomber et provoquer des blessures.
Ne touchez pas les volets en aluminium de
l’échangeur de chaleur.
Risque de blessure
Ne placez aucun appareil ménager électrique
ni d’autre équipement ménager sous le dispositif intérieur ou extérieur.
La condensation tombant de l’appareil peut ta­cher des objets et provoquer des accidents ou un choc électrique.
N'utilisez pas l'appareil sans le filtre à air.
Ceci peut causer un dysfonctionnements du système à cause de l'encrassement de l'échan­geur de chaleur.
Ne coupez pas l'alimentation immédiatement
après l'arrêt du fonctionnement.
Attendez au moins 5 minutes, sinon il y a a un risque de fuite d'eau ou de panne.
Ne contrôlez pas le système avec l'interrup-
teur principal allumé.
Cela peut entraîner un incendie ou une fuite d'eau. De plus, le ventilateur peut se mettre en marche de façon imprévisible, ce qui peut cau­ser des blessures.
Si des objets ou des feuilles se trouvent près du dispositif extérieur, de petits animaux risquent de pénétrer dans l’appareil et de toucher des pièces électriques pouvant générer une panne, de la fumée ou un incendie.
Contactez votre revendeur pour nettoyer
l’intérieur du dispositif interne. N’essayez pas de le faire par vous-même.
L’utilisation d’un détergent non approuvé ou d’une méthode de nettoyage inappropriée peut endommager les composants plastiques de l’appareil et entraîner des fuites. Tout contact du détergent avec des composants électriques ou le moteur de l'appareil peut générer une panne, de la fumée ou un incendie.
Arrêtez l’appareil et mettez-le hors tension si
vous entendez le tonnerre ou en cas de risque de foudre.
Risque d’endommager l’appareil.
PRÉCAUTIONS POUR LE DÉPLACEMENT OU LES RÉPARATIONS DE L’APPAREIL
Ne réparez ou ne modifiez jamais l'appareil par vous-même. Consultez votre distributeur si
l'appareil a besoin d'être réparé.
Si vous réparez ou modifiez l'appareil, ceci peut causer des fuites d'eau, électrocutions ou incendies.
Contactez votre revendeur pour toute répara-
tion de l’appareil.
Des réparations inadéquates peuvent provo­quer des décharges électriques, incendies, etc.
Si le climatiseur doit être déplacé, contactez
votre revendeur ou un installateur profes­sionnel.
Une installation inadéquate peut entraîner des fuites d’eau, des décharges électriques, des incendies, etc.
Si vous remarquez la moindre anomalie
(odeur de brûlé, etc.), arrêtez l’appareil, mettez-le hors tension et contactez votre revendeur.
Le fonctionnement continu en cas de condi­tions anormales peut provoquer le dysfonc­tionnement, des décharges électriques, des incendies, etc.
DANGER
Le fait que le climatiseur ne refroidisse/ré-
chauffe plus la pièce peut indiquer une fuite de réfrigérant. Contactez votre revendeur. S’il faut ajouter du réfrigérant, vérifiez avec votre revendeur la procédure correcte à sui­vre.
Si le réfrigérant entre en contact avec la peau nue, il peut provoquer une blessure due au froid. Si le gaz réfrigérant est inhalé avec excès, il peut provoquer une détérioration de la fonction nerveuse se traduisant par des vertiges et des maux de tête, ou une détérioration de la fonc­tion cardiaque se traduisant par des battements de cœur irréguliers et des palpitations cardia­ques, d'une durée temporaire. Une fuite acci­dentelle de réfrigérant sur un appareil de chauf­fage, un réchaud, une plaque chauffante ou toute autre source de chaleur, peut générer des substances nocives.
–25–
Description des éléments et leurs fonctions
DISPOSITIF INTÉRIEUR
SRK63ZK-S SRK71ZK-S SRK80ZK-S
Réceptionne l’air intérieur.
Filtre les poussières ou salissures de l’air aspiré. Page 38
Panneau d’arrivée d’air
Page 38
Ventilateur du dispositif intérieur
panneau de contrôle
Page 27
Télécommande sans fil
Filtre à air
Filtre de nettoyage d’air
Capteur de température ambiante
DISPOSITIF EXTÉRIEUR
Interrupteur de mise en marche/arrêt de l’unité
Sortie de l’air
Soufflage par volet motorisé.
Louvre de réglage du sens gauche/droit du flux d’air
Page 32
Volet motorisé
Page 32
Tuyau d’écoulement
Purge l’eau du dispositif intérieur.
Tuyaux de réfrigérant et câble électrique
Arrivée d’air
(Surface arrière & latérale)
Sortie d’air
Ventilateur du dispositif extérieur
Échangeur de chaleur
–26–
Description des éléments et leurs fonctions
Panneau de contrôle
Récepteur signal télécommande
Interrupteur ON/OFF de l’unité
Ce bouton vous permet d’allumer/arrêter l’appareil lorsque vous ne pouvez pas le faire à l’aide de la télécommande.
Page 28
Voyant RUN (HOT KEEP) (vert)
S’allume en fonctionnement.
Clignote lorsque le flux d’air est arrêté en
raison du fait que l’appareil est en mode « HOT KEEP » et « CLEAN ».
1.5 sec.
HOT KEEP
Mode CLEAN
ON
OFF
ON
OFF
0.5 sec.
3 sec.
1 sec.
Page 37
Accessories
RUN TIMER ECONO
HI
POWER
ON
/
OFF
Voyant ECONO (orange)
Éclairé en mode ECONOMY.
Voyant HI POWER (vert)
Éclairé en mode HIGH POWER.
Voyant TIMER (jaune)
S’allume en mode TIMER.
Télécommande sans fil Porte télécommande
NOTA
Signal sonore pour la télécommande
Avec une température préréglée de 24°C, le mode automatique et le flux d’air automatique sont sélectionnés, un signal sonore (bip bip) est émis.
Lors de l’arrêt du climatiseur par une pression sur le bouton MARCHE/ARRÊT (sauf en mode CLEAN), un signal sonore (bip) est émis.
Cette fonction est utile pour utiliser le climatiseur dans l’obscurité.
Réglage du flux d’air
sans fil
Filtre hypoallergénique
(Orange pâle)
Filtre photocatalytique désodorisant
lavable (Orange)
Température préréglée
–27–
Pile
(R03(AAA, Micro)×2)
Vis à bois (Quantité : 2)
(pour le montage du porte
télécommande)
Mode d’emploi de la télécommande
Remplacement des piles
Dans les cas suivants vos piles sont usagées. Remplacez les piles usées par des piles neuves.
Aucun « bip » n’est émis lorsque le signal est transmis par la télécommande au dispositif intérieur.
Le contraste de l’affichage est faible.
NOTA
Ouvrir le couvercle et retirer
1
les piles usagées.
Insérez les piles neuves.
2
R03 (AAA, Micro) x2
Veillez à respecter
la polarité (
,
et .)
Ne mélangez pas les piles usagées et les piles neuves.
Enlevez les piles quand vous n’utilisez pas la télécom mande pendant une longue période.
La durée de vie d’une pile conforme aux normes JIS ou IEC est de 6 à 12 mois en utilisation normale. Si on l’utilise plus longtemps ou si on utilise une pile non spéci­fiée, une substance liquide pourrait couler de la pile entraînant le non fonctionne­ment de la télécommande.
La durée de vie moyenne est indiquée sur la pile. Elle peut être moins longue
en raison de la date de fabrication de l’appareil. Toutefois la pile peut durer plus longtemps que prévu.
Si l’affichage indique un dysfonctionnement, appuyez sur l’interrupteur ACL avec la pointe d’un stylo à bille.
L’utilisation du support de boitier de télécommande
Refermez le couvercle.
3
Appuyez sur l’interrupteur ACL avec la pointe d’un stylo
4
bille.
La télécommande peut être utilisée en la fixant sur un mur ou un poteau à l’aide d’un support (un porte­télécom-mande). Dans ce cas, il faudra mettre la télé­commande en place en s’assurant que les signaux de contrôle émis de celle-ci vers le dispositif intérieur sont bien transmis.
Pour sortir et remettre la télécommande, il suffit de la glisser le long du porte-télécommande.
Remarques concernant l’usage de la télécommande
Interdiction totale
Ne la mettez pas à proximité d’appa-
reils électriques, un poêle ou d’autres appareils dégageant une temp. élevée.
Ne mettez pas d’obstacles entre la
télécommande et le dispositif.
Evitez de la mettre à un endroit
non protégé contre la lumière so­laire directe / l’éclairage puissant.
Protégez la télécommande de tout
type d’éclaboussures.
Attention, ne la laissez pas tomber.
Ne placez pas d’objets lourds sur la
Panne de la télécommande
Est-ce que les piles ne sont pas trop faibles?
Voir « Remplacer les piles » ci-dessus.
Remplacez les piles usagées par des piles neuves puis répétez la procédure.
Si l’appareil ne fonctionne toujours pas,
actionnez la fonction de secours.
Contactez votre revendeur pour que votre télécommande soit vérifiée.
Elle risque d’être endommagée.
télécommande et ne marchez pas dessus.
Ci-dessous.
Fonction de secours
La touche ON/OFF de l’unité permet d’actionner ON/OFF de l’appareil temporairement quand on n’utilise pas la télécommande.
Types de fonctionnement
OPERATION MODE : AUTO
FAN SPEED : AUTO
AIR FLOW : AUTO
L’appareil se met en route en appuyant sur la touche ON/OFF de l’unité,
en réappuyant il s’arrête.
NOTA
Ne maintenez pas le bouton ON/OFF de l’appareil enfoncé pendant plus de 5 secondes. (Maintenir ce bouton enfoncé pendant plus de 5 secondes déclenche la climatisation automatique utilisée pour l’entretien ou le déplacement du climatiseur.)
Interrupteur ON/OFF de l’unité
–28–
Loading...
+ 194 hidden pages