Mitsubishi SRK71HE, SRC71HE user guide manual

USER’S MANUAL
SRK63HE-S1 SRK71HE-S1
SRK63CE-S1 SRK71CE-S1
AIR-CONDITIONER
MANUEL DE L’UTILISATEUR
ANWENDERHANDBUCH
ISTRUZIONI PER L’USO
CONDIZIONATORE D’ARIA
ACONDICIONADOR DE AIRE
GEBRUIKERSHANDLEIDING
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO
√¢∏°π∂™ Ã∏™∏™
ENGLISH
FRANÇAIS
CLIMATISEUR
DEUTSCH
KLIMAGERA¨T
ITALIANO
ESPAN˜OL
NEDERLANDS
AIRCONDITIONING
PORTUGUÊS
∂§§∏¡π∫∞
∫§πª∞∆π™∆π∫√
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
This air conditioner complies with EMC Directive 89/336/EEC, LV Directive 73/23/EEC.
Ce climatiseur est conforme à la Directive EMC: 89/336/EEC, LV Directive 73/23/EEC.
Dieses Kimagerät erfüllt die EMC Direktiven 89/336/EEC, LV Direktiven 73/23/EEC.
Questo condizionatore d’aria è conforme alla Direttiva EMC: 89/ 336/EEC, LV Direttiva 73/23/EEC.
КОНДИЦИОНЕР ВОЗДУХА
KULLANIM KILAVUZU
SPL‹T KL‹MA
Este acondicionador de aire cumple con la directiva EMC: 89/ 336/EEC, LV Directiva 73/23/EEC.
Deze airconditioner voldoet aan EMC Directive 89/336/EEC, LV Directive 73/23/EEC.
Este aparelho de ar condicionado está em conformidade com a Directiva EMC 88/336/CEE e a Directiva LV 72/23/CEE.
∞˘Щfi ЩФ ОПИМ·ЩИЫЩИОfi В›У·И Ы‡МКˆУФ МВ ЩИ˜ ЪФ‰И·БЪ·К¤˜ ЩЛ˜ √‰ЛБ›·˜ EMC 88/396 Î·È Ù˘ √‰ËÁ›·˜ LV 73/23 Ù˘ ∂√∫.
RKW012A211
РУССКИЙ
TÜRKÇE
Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES, LTD. Air-Conditioner. To get the best long-lasting performance, read and follow this User’s Manual carefully before using your air-conditioner. After reading, please store the Manual in a safe place and refer to it for operational questions or in the event of any irregularities.
This air-conditioner is intended for domestic use.
This instruction manual contains the explanation of the heatpump air-conditioner. That of cooling-only air-conditioner shall be referred to the same explanation , with neglecting the information on heating-operation mode.
An alternative refrigerant (R410A) is used in this air-conditioner. When asking the dealer for service or inspection and maintenance, explain the dealer about this matter.
contents
Safety precautions......................................................................................................................... 2
Choice of operations and features ................................................................................................ 4
Name of each part and its function ............................................................................................... 5
Operation and indication section for remote control .................................................................... 7
AUTO mode operation procedure ................................................................................................ 8
Temperature adjustment during AUTO ........................................................................................ 8
About FAN SPEED ...................................................................................................................... 8
COOL/HEAT/DRY/FAN mode operation procedure .................................................................. 9
Air-conditioner operating conditions............................................................................................9
Characteristics of HEAT mode operation .................................................................................... 9
Air flow direction adjustment procedure .................................................................................... 10
SLEEP operation procedure .......................................................................................................11
OFF-TIMER operation procedure .............................................................................................. 11
ON-TIMER operation procedure................................................................................................ 12
SLEEP operation + ON-TIMER operation procedure ............................................................... 12
PROGRAM TIMER operation procedure .................................................................................. 13
Present time setting procedure .................................................................................................... 13
HIGH POWER/ECONOMY operation procedure ..................................................................... 14
Concerning CLEAN operation ................................................................................................... 15
Emergency run operation............................................................................................................ 15
Power blackout auto restart function .......................................................................................... 15
Remote control handling procedure ........................................................................................... 16
When the operation fails with the remote control ...................................................................... 16
Operating hints ........................................................................................................................... 17
Maintenance................................................................................................................................ 17
Has the unit been installed correctly? ......................................................................................... 19
Troubleshooting .......................................................................................................................... 19
Please remember! ....................................................................................................................... 20
When to contact your distributor without delay ......................................................................... 21
Self diagnosis function ............................................................................................................... 21
ENGLISH
–1–
Safety precautions
Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system.
The safety precautions are classified as “
improper handling could have dramatic consequences like death, serious injury, etc. Nevertheless, even precautions as shown in the column “
CAUTION” might pose a serious problem, depending on the circumstances. Please observe these precautions with great care, since they are
essential to your safety.
Symbols which appear frequently in the text have the following meaning:
DANGER” and “ CAUTION”. Precautions as shown in the column “ DANGER” indicate that
Strictly prohibited Provide positive earthing
When you have read the instruction manual, please keep it near at hand for consultation. If someone else takes over as operator, make certain that the manual is also passed on to the new operator.
Observe instructions with great care
INSTALLATION PRECAUTIONS
DANGER
The system is meant for domestic, residential etc. use.
If used in inferior environments, such as an engineering workplace, the equipment may function poorly.
Do not install near places where inflammable gas may leak.
LPG
Gas leaks may cause fire.
Make sure that you drain the hose properly, so that all the water has dripped out.
The system must be installed by your dealer or a qualified pro­fessional.
It is not advisable to install the system yourself, as faulty handling may cause leak­age of water, electric shock or fire.
CAUTION
Depending on the place of installation, a circuit breaker may be necessary.
If you don’t fit a circuit breaker, you may cause an electric shock.
Make sure that the system has been properly earthed.
Negligence may cause flooding in the room resulting in wet furniture.
OPERATION PRECAUTIONS
Do not expose yourself to the cooling air for prolonged periods.
This could affect your physical condition and cause health problems.
Only use approved fuses.
Use of steel or copper wire instead of an approved fuse is strictly forbidden, as it may cause a breakdown or fire.
Do not insert anything into the air inlet.
This may cause injury, as the internal fan rotates at high speed.
Do not handle the switches with wet hands.
This may cause an electric shock.
Earth cables should never be connected to a gas pipe, municipal water pipe, light­ning conductor or telephone earth cable. Incorrect installation of the earth cable may produce an electric shock.
DANGER
Store the remote control out of reach of infants.
Failure to observe this may result in the batteries being swallowed or other accidents.
CAUTION
Don’t swing from the system.
If the system falls down, you may get injured.
2
Safety precautions
Do not place a combustible insecticide or paint spray near the blower, nor aim it directly at the system.
CAUTION
You should not expose any combus­tion appliance directly to the air stream of the air-conditioner.
Do not wash the air-conditioner with wa­ter.
This may result in a fire.
The system should only be used for its original purpose and not for anything else like, for instance, preservation of food, plants or animals, precision devices or works of art.
The system is only intended for use in ordinary domestic rooms. Any other use of the system may damage the quality of food, etc.
Do not sit on the outdoor unit nor put anything on it.
If the unit falls down or things drop off it, people could get hurt.
If you operate the system together with a combustion appliance, you must regu­larly ventilate the indoor air.
The appliance may then work inadequately.
Do not place anything containing wa­ter, like vases, on top of the unit.
Water entering the unit could damage the insula­tion and therefore cause an electric shock.
After a long period of use, check the unit's support structure from time to time.
If you don't repair any damage straightaway, the unit may fall down and cause personal injury.
Stand firmly on a stepladder or other stable object when removing the inlet panel and filters.
This could cause an electric shock.
Do not install the system at a place where the air stream of the blower is aimed directly at plants or animals.
This will damage their health.
Do not touch the aluminum fins on the air heat exchanger.
Failure to observe this may result in injury.
When you clean the system, stop the unit and turn off the power switch.
Insufficient ventilation may cause accidents due to oxygen deficiency.
Do not place objects near the outdoor unit or allow leaves to gather around the unit.
If there are objects or leaves around the outdoor unit, small animals may enter unit and contact electrical parts resulting in break down, emission of smoke or flame.
Failure to observe this may result in injury through insecure objects toppling over.
PRECAUTIONS FOR TRANSFER OR REPAIRS
DANGER
Consult your dealer for repairs to the system.
Wrong repairs could cause an electric shock, fire, etc.
If the air-conditioner is moved else­where, contact your dealer or a pro­fessional fitter.
Faulty installation may cause water leakage, elec­tric shock, fire, etc.
3
Never clean the unit while the internal fan is rotating.
If you notice anything abnormal (smell of burning, etc.), stop the system, turn off the power switch and consult your dealer.
Continued use of the system in abnormal circum­stances may result in malfunctioning, electric shock, fire, etc.
Choice of operations and features
Choice of operations
HEAT
The unit draws in heat from the outside air, transfers it inside and heats the room.
Fanning by circulating room air.
Page 9
Page 9
COOL
Cooling by extracting heat from the room.
AUTOFAN
Automatic selection of operating mode.
Page 9
Page 8
DRY
Drying by extracting damp from the room.
Functioning of microcomputer depends on setting and room temperatures. It dehumidi­fies while keeping room temperature almost constant.
The Auto mode automatically selects the operation mode (HEAT, COOL or DRY), depending on the room temperature when switched on.
Page 9
Features
Amenity facility
When using the timer to switch on, the sys­tem should become operational shortly be­fore the set time, depending on the room temperature so that the desired temperature should be reached at the set time.
Adjustment of
airflow
Page 13
Page 10
MULTI-DIRECTIONAL AIR FLOW This function sets the unit at the most suitable angle
for blowing, imitating a natural breeze.
SWING FLAP Flap moves up and down continuously.
SWING LOUVER Louver moves left and right continuously.
MEMORY FLAP (FLAP OR LOUVER STOPPED) Once the flap or louver position has been set, the unit
will memorise it and continue in the same position the next time.
TIMER procedure
There are three timers, for SLEEP, ON and OFF. They can be set as desired.
Page 11, 12
HIGH POWER mode
Turning up the power operates the air-condi­tioner in the power cooling and heating mode.
ECONOMY mode
This is an economic level of operation.
Page 14
Page 14
4
Name of each part and its function
INDOOR UNIT
SRK63HE-S1 SRK71HE-S1
SRK63CE-S1 SRK71CE-S1
Air inlet panel
Draws in the indoor air.
Unit indication section and remote control signal receiver
Wireless remote control
Air filter
Removes dust or dirt from the inlet air.
Page 17
Photocatalytic washable deodorizing filter
Natural enzyme filter
Room temperature detector
Unit operation switch
Air outlet
Air blows out of here.
Left/right air flow adjustment louver
Page 10
Up/down air flow direction adjustment flap
Page 10
OUTDOOR UNIT
SRC63HE-S1 SRC71HE-S1
* The appearance varies for Models 63 and 71.
SRC63CE-S1 SRC71CE-S1
(on side & rear surface)
Air inlet
Air outlet
Drains water from the dehumidified air.
Refrigerant piping connection electric flex
Accessories
Wireless remote control
Natural enzyme filter
5
Wireless remote
control holder
(green)
Drain hose
Battery (R03×2)
Wood screw (Quantity:2)
(for remote control holder mounting)
Photocatalytic washable deodoriz-
ing filter (orange)
Unit indication section
HI POWER light (green)
Illuminates during HIGH POWER operation.
ECONOMY light (orange)
Illuminates during ECONOMY operation.
RUN (HOT KEEP) light (green)
Illuminates during operation.
Blinks at air flow stop due to the HOT KEEP
and CLEAN operation’.
HOT KEEP
CLEAN operation
ON
OFF
ON
OFF
1.5 sec.
3 sec.
Page 20
0.5 sec.
1 sec.
TIMER light (yellow)
Illuminates during TIMER operation.
How to open the air inlet panel
Place fingers at the recesses on both sides of the panel and pull up the panel to this side so that it will be opened by about 60 degrees.
How to close the air inlet panel
Push both sides evenly and press further lightly at the center.
Removal, installation of air inlet panel
When removing the air inlet panel for internal cleaning or others, open the panel by 80 degrees and then pull it to this side.
Unit ON/OFF button
In emergencies, this button can be used for turning on/off the unit when re-
mote control is not available.
Page 15
Unit ON/OFF button
Secure either the upper or lower edge of the air inlet panel by lightly pushing it in, and then close the panel.
6
Operation and indication section for remote control
Operation section
FAN SPEED button
Each time the button is pushed, the indi­cator is switched over in turn.
HI POWER/ECONO button
This button changes the HIGH POWER/ ECONOMY mode.
Page 14
TEMPERATURE button
This button sets the room temperature. (This button changes the present time and
TIMER time.)
SLEEP button
This button changes to SLEEP operation.
Page 11
CLEAN switch
This switch changes the CLEAN mode.
Page 15
ON TIMER button
This button selects ON TIMER operation.
Page 12
The above illustration shows all controls, but in practice only the relevant parts are shown.
OPERATION MODE select button
Each time the button is pushed, the indi­cator is switched over in turn.
ON/OFF (luminous) button
Press for starting operation, press again for stopping.
AIR FLOW (UP/DOWN) button
This button changes the air flow (up/down) mode.
Page 10
AIR FLOW (LEFT/RIGHT) button
This button changes the air flow (left/right) mode.
Page 10
CANCEL button
This button cancels the ON timer, OFF timer, and SLEEP operation.
OFF TIMER button
This button selects OFF TIMER operation.
Page 11
RESET switch
Switch for resetting microcomputer.
Page 16
TIME SET UP switch
This switch for setting the time.
Page 13
Indication section
SLEEP indicator
Indicates during SLEEP operation.
TEMPERATURE indicator
Indicates set temperature. (Does not indicate temperature when operation mode is on AUTO)
FAN SPEED indicator
Indicates set air flow rate with lamp.
CLEAN indicator
Indicates during CLEAN operation.
ON/OFF TIMER indicator
Indicates during ON/OFF TIMER operation.
OPERATION MODE indicator
Indicates selected operation with lamp. HE type: [ (Auto) • (Cool) • (Heat) • (Dry)] CE type: [ (Auto) (Cool) (Fan) (Dry)]
TIME indicator
Indicates present time or timer setting time.
AIR FLOW indicator
Shows selected flap and louver mode.
HI POWER/ECONO MODE indicator
Indicates during HIGH mode operation.
POWER/ECONOMY
Transmission procedure
When each button on the remote control is pressed – with the remote control pointing towards the air-conditioner unit – a signal is transmitted. When the air-conditioner receives the signal correctly, it will beep.
7
AUTO mode operation procedure
Automatically selects the operation mode (HE type: HEAT, DRY, COOL/CE type: COOL, DRY) depending on the room temperature when switched on.
When the unit is not in AUTO mode: Aim the remote control at the air-conditioner.
Press MODE button.
Move the [ mark] to the (Auto) position.
If the air-conditioner is not operating
Press the ON/OFF button.
To stop: Press the ON/OFF button.
AUTO mode can be operated by simply pressing the ON/OFF button.
If you don’t want the AUTO mode program, change to COOL, HEAT, DRY or FAN instead of AUTO.
Air flow direction adjustment
procedure.
Page 10
1
2
NOTE
Air is not blown out during the op­eration.
Page 20
Temperature adjustment during AUTO
Page 9
Air temperature adjustment is possible even during automatic operation. There are 6 levels of adjustment possible with the button or the button.
Each time the
Each time the button is pressed, the switch over occurs in the following order
When a change in temperature is desired. Aim the remote control at the air-conditioner.
1
When it is a little cold
Press the
When it is a little hot
Press the
Press the or button.
button.
button is pressed, the switch over occurs in the following order
–6 –5 ............ –1 → ±0 +1 ............ +6.
When +6 is indicated, even if the button is pressed, the indicator does not change.
button.
+6 +5 ............ +1 → ±0 –1 ............ –6.
When –6 is indicated, even if the button is pressed, the indicator does not change.
About FAN SPEED
You can choose the capacity of your air-conditioner when heating, cooling or fan.
Operation capacity by your choice FAN SPEED
Set automatically by microcomputer AUTO
Powerful operation with high capacity HI
Standard operation MED
Energy-saving operation LO
Aim the remote control at the air-conditioner.
Press the FAN SPEED button.
Move the [ mark] to the desirable fan speed position.
AUTO HI MED LO
–8–
COOL/HEAT/DRY/FAN mode operation procedure
COOL
DRY
HEAT
26°C~28°C21°C~24°C
FAN
——22°C~24°C
Aim the remote control at the air-conditioner.
Air flow direction adjustment procedure. Page 10
NOTE
Air is not blown out during the operation.
Page 20
1
2 3
4
Press the MODE select button.
Move the [ mark] to the desirable operation position.
HE type: CE type:
If the air-conditioner is not operating
Press the ON/OFF button.
Press the TEMP button.
Press or button for the desired temperature.
Standard
Press the FAN SPEED button
Set the fan speed as desired.
(Cool), (Heat), (Dry) (Cool), (Fan), (Dry)
To stop: Press the ON/OFF button.
Program changing procedure
Set the new program.
The operation program can also be set or changed when the air-conditioner is not in operation.
Air-conditioner operating conditions
Use within the following operational range. Operating outside of this range may result in the protection devices being activated, preventing the
unit from working.
Cooling operation Heating operation
Outside temperature Approximately 21 to 43 °C Approximately -5 to 21 °C
Inside temperature Approximately 21 to 32 °C Approximately 15 to 30 °C
Below approximately 80%
Inside humidity
The long-term use of the unit with a humidity level exceeding 80% may result in condensation forming on the surface of the indoor unit, leading to water drips.
Characteristics of HEAT mode operation
Mechanism and capacity of HEAT mode operation
Mechanism
The unit draws in heat from the cold outside air, transfers it indoors and heats the room. The heating capacity of the heat pump mechanism decreases when the outside air temperature gets colder.
The hot air circulation system takes a while before warming up the room temperature.
If the outside temperature becomes extremely low, it would be better to use an additional source of heating.
Defrosting
If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents efficient heating.
If this happens, the automatic defroster is activated and during defrosting the heating operation stops for 5 to 10 minutes.
Both indoor and outdoor fans stop and the RUN light (green) blinks slowly (1.5 sec. ON, 0.5 sec. OFF) during defrosting.
The outdoor unit may give off some steam during defrosting. This is to help the defrosting process and is not a defect.
The HEAT operation resumes as soon as defrosting has been completed.
9
Air flow direction adjustment procedure
Adjusting air flow direction
Up/down direction can be adjusted with the AIRFLOW
the mode changes as follows: Change to AIRFLOW (UP/DOWN) mode.
(UP/DOWN) button on the remote control. Each time when you press this button
(Flap stopped)
Left/right direction can be adjusted with the AIRFLOW (LEFT/RIGHT) button on the remote control. Each time when you press this
button the mode changes as follows: Change to AIRFLOW (LEFT/RIGHT) mode.
(Louver stopped)
(Swing)
(Swing)
NOTE
When heating operation starts, the cold air outlet is blocked, so the flap and louver move to the horizontal / center position, and resume the position that was set after the warm air output begins.
When the compressor stops because the room temperature is higher than the temperature setting and it is in DEFROSTING operation, the flap and louvers will be in the horizontal / center position.
The air flow direction cannot be set in the instances above. Change the air flow direction settings after the warm air starts flowing and it moves to the airflow direction that had been set.
Multi-directional Air Flow (up/down air scroll and left/right air scroll)
Activating both up/down air swing and left/right air swing at the same time results in a multi-directional air flow.
Up/down air scroll Left/right air scroll
In COOL, DRY and FAN operation
Stops at this position for 5 seconds.
In HEAT operation
Stops at this position for 5 seconds.
In COOL, DRY and FAN operation
In HEAT operation
Thick line : moves quickly
Thin line
: moves slowly
Left louver Right louver
MEMORY FLAP (FLAP OR LOUVER STOPPED)
When you press the AIRFLOW (UP/DOWN or LEFT/RIGHT) button once while the flap or louver is operating, it stops swinging at an angle.Since this angle is memorized in the microcomputer, the flap or louver will automatically be set at this angle when the next operation is started.
Avoid constant airflow to the body for hours on end.
When in COOL or DRY operation, do not operate for hours on end with the air
flow blowing straight down. Otherwise, condensation may appear on the outlet grill and drip down.
Do not try to adjust the flaps and louvers by hand, as the control angle may change or the flap or louver may not close properly.
DANGER
CAUTION
10
Recommended angle of the flap when stopping
HEAT
COOL, DRY
(Slant forward
blowing)
(Horizontal
blowing)
SLEEP operation procedure
The unit stops automatically at the end of the set period of time.
The room temperature is automatically controlled when the set time lapses, so that the room does not become too cold during cooling or too warm
during heating.
Page 13
Aim the remote control at the air-conditioner.
Press the SLEEP button.
1
If this is pressed while the unit is off
SLEEP operation starts with the previous operation settings, and the air conditioning is turned off after the time that has been set passes.
If this is pressed while the unit is running
Each time the button is pressed, the indication changes as follows:
...
(Units of one hour)
No indication
(cancelled)
Example: You wish it to stop after 7 hours.
Set to
The timer light (yellow) is on.
1
The unit stops at the end of the set period of time.
h
Changing of set time
Set to a new time by using SLEEP button.
Releasing procedure
Press the CANCEL button to turn off the SLEEP indicator.
OFF-TIMER operation procedure
The unit stops automatically at the end of the set period of time. If it is stopped, perform the operations starting with STEP 1 and if running start with STEP 2.
Example: You wish it to stop 22:30. Aim the remote control at the air-conditioner.
If the air-conditioner is not operating
1 2
3
Press the ON/OFF button.
Press the OFF TIMER button.
OFF TIMER indicator is blinking.
Press the or button.
Each time the button is pressed, the indicator is switched in the order of:
0:00 0:10 0:20
Each time the button is pressed, the indicator is switched in the order of:
0:00 23:50 23:40
Set at 22:30.
...
...
23:00 22:50
1:00 1:10
(Units of ten minutes)
(Units of ten minutes)
Changing of set time
Set a new time by using the OFF TIMER button.
Releasing procedure
Press the CANCEL button to turn off the timer indicator.
4
Press within
Press the OFF TIMER button.
The indication changes from blinking to steady lighting and the setting is complete. The timer light (yellow) is on.
The unit stops at the end of the set period of time.
11
h
60 sec.!
ON-TIMER operation procedure
Operation starts 5 to 60 minutes before the time that is set so that the room temperature reaches the optimum temperature at that time. ON-TIMER operation can be set regardless of whether the air-conditioner is running or not.
Example: In the case you wish to bring the temperature to nearly set temperature in at 8:00. Aim the remote control at the air-conditioner.
Page 13
1
2
3
Changing of set time
Set a new time by using the ON-TIMER button.
Press the ON-TIMER button.
ON TIMER indicator is blinking.
Press the or button.
Each time the button is pressed, the indicator is switched in the order of:
h
...
...
23:00 22:50
1:00 1:10
(Units of ten minutes)
(Units of ten minutes)
Press within
60 sec.!
0:00 0:10 0:20
Each time the button is pressed, the indicator is switched in the order of:
0:00 23:50 23:40
Set at 8:00.
Press the ON TIMER button.
The indication changes from blinking to steady lighting and the setting is complete. The timer light (yellow) is on.
Operation starts 5 to 60 minutes before the set time.
The TIMER light goes out at the set time.
Releasing procedure
Press the CANCEL button to turn off the timer indicator.
SLEEP operation + ON-TIMER operation procedure
Combined timer operation of SLEEP operation and ON TIMER.
Changing of set time
Set a new time by using the SLEEP or ON TIMER button.
Releasing procedure
Press the CANCEL button to turn off the timer indicator.
Example: When it is desired to stop after 3 hours and then start operation at 8:00, near
the set temperature.
SLEEP operation setting
Set by the procedures on page 11.
Set to
ON TIMER operation setting
Set by the above mentioned ON TIMER operation procedure.
Set to
The setting of the lighting of the timer light (yellow) of this unit is complete.
After the SLEEP operation set time has elapsed, the operation stops, and it starts from 5 to 60 minutes before the ON TIMERs time.
The timer light is not lit at the ON TIMER’s time.
h
12
PROGRAM TIMER operation procedure
The timer operations that consist of the combination of the timer being set at both on and off. Once this has been set and operations started,
operations will commence and end at the same time every day as long as the ON/OFF button is not pressed.
Example: When it is desired to stop at 22:30, and then start operation at 8:00, near the set
temperature.
OFF TIMER operation setting
Set by the procedures on page 11. Set to
ON TIMER operation setting
Set by the procedures on page 12. Set to
The setting of the lighting of the timer light (yellow) of this unit is complete.
The time will be displayed on the remote control unit. The display will change depending on the operational status.
(Stopped) (Operating)
Changing of set time
Set a new time by using the OFF TIMER or ON TIMER button.
Releasing procedure
Press the CANCEL button to turn off the timer indicator.
About Amenity facilities
Amenity facilities enable to start the operation a little earlier, so that the room should approach optimum temperature at ON time when the operation is started by ON-TIMER.
Mechanism The room temperature is checked 60 minutes before the timer is at ON. Depending on the tempera­ture at that time, the operation starts 5 to 60 minutes before the timer is at ON.
The Amenity facility only func­tions for COOL and HEAT op­eration mode (including AUTO). It does not work for DRY mode.
In COOL operation
(Stop) Operation starts
Set temperature
Check the room temp. 60 mins. in advance.
(Operation)
Set time
When SLEEP operation is selected, the room temperature is automatically controlled after a while, ensuring that the room is not too cold during cooling or too warm during heating.
During COOL : the preset temperature is lowered by 1°C at the start of SLEEP operation (when the timer is set). After that, the temperature goes up by 1°C every an hour to become 2°C higher.
During heating: Preset temperature is lowered by 1°C at the start of SLEEP operation (when the timer is set). After that the temperature is lowered by 1°C every 30 minutes to become 3°C lower in an hour and 6°C lower in two hours.
Present time setting procedure
When inserting the batteries, the present time is automatically set to 13:00.
Example: Set to 10:30.
1
2
Press the TIME SET UP switch.
Press with the tip of a ballpoint pen, etc. The time indicator blinks and can be set to the current time.
Press the or button.
(Set to 10:30)
About SLEEP operation
Press within
3
Press the TIME SET UP switch.
The indication changes from blinking to steady lighting and the setting is complete.
NOTE
The timer operation is set on the basis of the present time, so please set it correctly.
60 sec.!
13
HIGH POWER/ECONOMY operation procedure
Aim the remote control at the air-conditioner.
If the air-conditioner is not operating
1
Press the ON/OFF button.
2
Concerning
Pressing the HI POWER/ECONO button intensifies the operating power and initiates powerful cooling or heating operation for 15 minutes
continuously. The remote control
During the HIGH POWER operation, the room temperature is not controlled. When it causes an excessive cooling or heating,press the HI POWER/ECONO button once more to cancel the HIGH POWER operation.
HIGH POWER operation is not available during the DRY and the program timer operations.
During ON timer operation, HIGH POWER operation will start when the ON time is reached.
Concerning
Pressing the HI POWER/ECONO button intlates a soft operation with the power suppressed in order to avoid an excessive cooling or heating. The unit operates 1.5°C higher than the setting temperature for weak wind capacity during cooling or 2.5°C lower than that during heating. The remote
control
HIGH POWER
NOTE
ECONOMY
indicates but the FAN SPEED indication is eraseed.
operation
indicates but the FAN SPEED indication is erased.
operation
Press the HI POWER/ECONO button.
When the operating mode is AUTO, COOL or HEAT
Each time the HI POWER/ECONO button is pressed, the indicator is switched
in the order of:
(
HIGH POWER
When the operating mode is DRY or PROGRAM TIMER
Each time the HI POWER/ECONO button is pressed, the indicator is switched
in the order of:
ECONOMY
(
When the following operations are conducted HIGH POWER op­eration will be canceled.
1 When the HI POWER/ECONO button is pressed again. 2 When the operation mode is changed. 3 When it has been 15 min. since HIGH POWER operation
has started.
)(
ECONOMY
) (Normal operation)
No indication
) (Normal operation)
No indication
NOTE
It will go into ECONOMY operation the next time the air-condi­tioner runs in the following instances.
1
When the air-conditioner is stopped using the ON/OFF button.
2
When the air-conditioner is stopped in SLEEP or OFF
TIMER operation.
3 When CLEAN operation ends.
When the following operations are conducted ECONOMY opera­tion will be canceled.
1 When the HI POWER/ECONO button is pressed again. 2 When the operation mode is changed DRY to FAN.
14
Concerning CLEAN operation
CLEAN operation should be run after AUTO, COOL and DRY operation to remove the moisture from inside the indoor unit and control the growth
of mold and bacteria.
Aim the remote control at the air-conditioner.
Press the CLEAN switch with the tip of a ballpoint pen.
1
Each time the CLEAN switch is pressed, the indicator is switched in the order of:
(CLEAN on) (CLEAN off)
To stop: Press the ON/OFF button.
NOTE
CLEAN operation is impossible after Heating, Fan and OFF-TIMER have stopped.
The indoor unit fan runs for about two hours in CLEAN operation.
The RUN light flashes during CLEAN operation.
No indication
Emergency run operation
The unit ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.
Operation program
OPERATION MODE : AUTO
FAN SPEED : AUTO
AIR FLOW : AUTO
Operation starts by pressing the unit ON/OFF button; it stops if you press
the button again.
Unit ON/OFF button
Power blackout auto restart function
What is power blackout auto restart function?
Power blackout auto restart function is a function that records the operational status of the air-conditioner immediately prior to it being switched off by a power cut, and then automatically resumes operations at that point after the power has been restored.
The following settings will be cancelled:
1 Timer settings 2 HIGH POWER operations
NOTE
The power blackout auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs to be switched off.
When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset the timer.
15
Remote control handling procedure
Replacing the batteries
The following cases signify exhausted batteries. Replace old batteries with new ones.
Receiving beep is not emitted when a signal is transmitted.
Indicator fades away.
Remove back lid and take out
1
old batteries.
Insert new batteries.
2
(SUM-4 or R03x2)
Attention to
the , and .
marks
NOTE
Don't use old and new batteries together.
Remove the batteries when the remote control is not used for a
long period.
The life of a battery conforming to JIS or IEC should be 6 to 12 months with normal use. If used longer, or when an unspecified battery is used, liquid may leak from the battery, causing the re­mote control to malfunction.
Close back lid.
3
Press the reset switch with the
4
tip of a ballpoint pen.
When the indicator shows any abnormal condition, Press the reset switch with the tip of a ballpoint pen.
On the battery is printed its expected life. This may be shorter
However, the battery may still be in working order after expiry
Using the remote control holder
The remote control can be attached to a wall or pillar by using a remote control holder. Before installing the remote con­trol, check that the air-conditioner re­ceives the signals properly.
For installing or removing the remote control, move it up or down in the holder.
than that of the air-conditioner, depending on the date of manu­facture.
of its nominal life.
Warning note for remote control handling
Don’t go near high temperature places, such as an electric carpet or stove.
Don’t put any obstructing obsta- cles between the remote control and the unit.
Don’t leave the remote control ex- posed to direct sunlight or other strong lighting.
Don’t spill water etc on the remote control.
Don’t drop the remote control. Handle with care.
Do not place heavy objects on the remote control, or step on it.
When the operation fails with the remote control
Are the batteries running down?
"Replacing the batteries" above.
Replace the batteries with new ones and repeat the operation.
If the operation still fails, handle as per emergency run operation. Contact your dealer.
Page 15
16
Operating hints
Please observe the following for the most economic and comfortable use of your unit.
Set a suitable room temperature.
suitable temperature
Excessively high or low temperatures are not good for your health and waste electricity.
Adjust the airflow direction properly.
Adjust the up/down and left/right airflow to ensure a steady room temperature.
Clean the filters frequently.
Clogged filters may block the air flow and cause less efficient operation.
Operate the unit only when needed.
Use the timer properly to operate the unit only when needed.
Avoid direct sunlight and draught.
Cut out direct sunlight by drawing the cur­tains or blinds when cooling. Keep windows and doors shut, except when ventilating.
Generate little heat when cooling.
Keep heat sources out of the room as much as possible.
Maintenance
Before maintenance During the operational season
Turn off the power switch.
Cleaning the air filter Standard interval is once every two week
Remove the air filter
1
1 Pull up to this side the air inlet panel.
Lightly hold the knobs at both sides and
2
lift a little to remove the panel to this side.
Dont spill water.
There's a danger of electric shock.
Wipe the unit with a soft, dry cloth.
Do not touch the aluminum fins on the heat exchanger. Stand firmly on a stepladder or other stable
object when removing the inlet panel and filter.
Dont use the following articles:
Hot water (40°C or more)
It may deform or discolour the unit.
Petrol, paint thinner, benzine or polishing agents,
etc. They may deform or scratch the unit.
Cleaning
2
If the filter is very dirty, clean it with warm water (approx. 30°C), and dry it thoroughly.
Dont clean the filters with boiling water.
Dont dry them over an open flame.
Pull them out gently.
Reinstall the air filter
3
Holding firmly the filter at both sides as shown at right and insert securely.
Operating without putting back the air filters will make the unit dusty, and may cause damage.
Cleaning the unit
Wipe the unit with a soft, dry cloth, or use a vacuum cleaner.
If the unit is very dirty, wipe it with a cloth soaked in warm water.
Cleaning the air inlet panel
Removal, installation of air inlet panel .
The panel can be washed with water. After washing with
water, wipe any moisture off the panel and dry out of direct sunlight.
CAUTION
Page 6
17
NOTE
Cooling/heating is affected by an air filter clogged up with dust etc., and the operation noise becomes louder. It may also use extra electricity. Please clean the air filter at appropriate intervals.
At the end of the season
Set the temperature setting for approximately a half
1
day at 30°C and perform the cooling operation.
Dry the inside of the unit.
Stop the unit and turn off the power switch.
2
The unit uses appr. 2W even when the power switch has been turned off during the off-season for safety or for saving energy.
Clean and reinstall the air filters.
3
Clean both the indoor and outdoor units.
4
Remove batteries from the remote control.
5
Installing, inspecting, and replacing the natural enzyme filter and the photocatalytic washable deodorizing filter
Installing the natural enzyme filter and the photocatalytic washable deodorizing filter
1. Open the air inlet panel and remove the air filters.
2. Install the filter holders, with the natural enzyme filter and the photocatalytic washable deo­dorizing filter installed in the holders, in the air-conditioner.
3. Install the air filters and close the air inlet panel.
NOTE
At the beginning of the season
Make certain that there are no obstacles blocking the
1
air flow around the air intake and outlet openings of the indoor and outdoor units.
Check the installation base for corrosion or rust.
2
Ensure that nothing has snapped and that the earthed flex is not disconnected.
3
Ensure that the air filters are clean.
4
Turn on the power switch.
5
Insert batteries in the remote control.
6
The natural enzyme filter and the photocatalytic washable deodoriz­ing filter may be installed on either the right or left side of the air­conditioner.
Inspecting and replacing the natural enzyme filter and the photocatalytic washable deodorizing filter
1. Open the air inlet panel and remove the air filters.
2. Remove the filter holders, with the natural enzyme filter and the photocatalytic washable deodorizing filter installed in the holders, from the air-conditioner.
3. Remove the natural enzyme filter from the filter holder and inspect the filter. Use a vacuum cleaner to remove any dust or dirt from the natural enzyme filter. Replace the natural enzyme filter if it cannot be cleaned or if it has been used for about 1 year. (The natural enzyme filter should be replaced after about 1 year of use. However, the actual replacement period may vary depending on the conditions in which the filter is used.) Remove the photocatalytic washable deodorizing filter from the filter holder and inspect the filter. Periodically, remove any dust or dirt from the photocatalytic washable deodorizing filter. If the photocatalytic washable deodorizing filter is particularly dirty, it may be washed with water. However, the filter is fragile so be sure to wash it installed in the filter holder to avoid damaging it. After washing the filter, place it in sunlight to dry. Placing the filter in sunlight revitalizes the deodorizing effect. (Do not dispose of the filter holders. They are reused.)
4. Install the natural enzyme filter and the photocatalytic washable deodorizing filter in the filter holders, and then install the filter holders in the air-conditioner.
5. Install the air filters and close the air inlet panel.
For replacement natural enzyme filters and photocatalytic washable deodorizing filters, contact your dealer.
CAUTION
Do not expose natural enzyme filters to direct sunlight for an extended period. The bacteriolytic effect will be lost.
Item Feature Color
Natural enzyme filter Green
Photocatalytic washable deodorizing filter
By using the work of oxygen, mold and bacteria on the filter are destroyed and the room air is kept clean.
Sources of odors on the filter are broken up, resulting in a deo­dorizing effect.
Orange
Filter holder
Filter
InstallInstall
18
Has the unit been installed correctly?
Suitable installation position
Is there any obstruction in front of the indoor unit, preventing proper ventilation and functioning?
Dont install the unit in any of the following places:
Where there is a danger of leaking inflammable gases.
Where there is substantial splashing of oil.
Malfunctioning due to corrosion may occur if the unit is installed in a spa where sulfide gases are generated, or in a seaside resort exposed to
sea breezes. Contact your dealer.
The air-conditioner and remote control must be at least 1 metre away from a TV set or radio.
Drain the dehumidified liquid from the indoor unit into a spot that drains well.
Pay attention to operating noises!
When you install the unit, take care to choose a place that can comfortably stand the weight of the unit and does not increase the operating noise or vibration. If there is any likelihood that vibration may be transmitted through the house, fix the unit with the aid of vibration-proof pads between the unit and the fittings.
Select a place where cold or hot air and operation noises from the indoor and outdoor units do not cause any inconvenience to your neighbours.
Do not leave any obstacles near the outlet and inlet of the outdoor unit. This may cause malfunctioning and increased operating noise.
If you hear an irregular noise during operation, contact your dealer.
Inspection and maintenance
Dependent upon service conditions and operating environment, the inside of the air-conditioner may become dirty after a number of seasons' service (3 to 5 years). This will reduce performance. In addition to normal cleaning, we would recommend inspection and maintenance. (The air­conditioner has a longer life without any trouble.)
Contact your dealer, or any distributor, for inspection and maintenance. (There will be a charge for this service).
We would recommend inspection and maintenance to be carried out during the off-season.
If the supply cord of this appliance is damaged, it must only be replaced by a repair shop appointed by the manufacturer, because special
purpose tools are required.
Troubleshooting
Please carry out the following checks before making a service call.
The air-conditioner does not work at all.
Has the power switch been turned off?
Have you set the thermostat at a suitable temperature?
suitable
temperature
Is there any direct sunlight en­tering the room?
Has the timer been set in the "ON" position?
Poor cooling or heating
Is the air filter clean? (Not clogged?)
Poor cooling
Is there a heat source in the room?
Is there a power failure or a blown fuse?
Did you leave any doors or windows open?
Are there too many people in the room?
If the air-conditioner does not oper­ate properly after you have checked the left points, or if any doubt still exists after you have consulted page 20, or if things happen as shown on page 21, switch off the power and contact your dealer.
An alternative refrigerant (R410A) is used in this air-conditioner. When asking the dealer for service or inspection and maintenance, explain the dealer about this matter.
– 19 –
Please remember!
You cannot restart the unit immediately after you have stopped it.
(RUN light is on)
Not
operating?
Air is not blown out when starting the HEATING operation.
RUN light blinks slowly
(1.5 sec ON, 0.5 sec OFF)
Air is not blown out for 5 to 10 min. or blown out not warm wind for a moment at HEATING operation.
RUN light blinks slowly
(1.5 sec ON, 0.5 sec OFF)
Air is not blown out when starting the DRY operation.
(RUN light is on)
Some steam escapes during COOL operation.
There is a slight smell.
You hear a slight gurgling sound.
Restarting has been blocked for 3 minutes after you have stopped or after switching off the power during operation, to protect the unit.
Please wait for three minutes.
The three-minute protection timer in the microcomputer automatically starts up again.
Air flow has stopped to prevent blowing out of cold air until the indoor heat exchanger has warmed up. (2 to 5 min.) (HOT KEEP)
When outdoor temperature is low and humidity is high, the unit some­times performs defrosting automatically. Please wait. During defrost­ing, water or steam may escape from the outdoor unit.
The indoor fan may stop to prevent re-evaporation of dehumified moisture and to save energy.
This may occur if the room's temperature and humidity are very high. It disappears as soon as the temperature and humidity decrease.
Air blown out during operation may smell. This is caused by tobacco or cosmetics sticking to the unit.
This is caused by refrigerating liquid moving within the unit.
You hear a slight cracking sound.
You hear a hissing or clicking sound.
After a power cut, you cannot re-start, even if power has been re­stored, unless you have the power blackout auto restart function.
Remote control signals are not received.
Moisture may form on the air outlet grills.
This is caused by heat expansion or contraction.
This is caused by the operation of the refrigerant control valves or electric components.
The memory circuit of the microcomputer has been wiped out. Use the remote control to start the operation again.
Remote control signals may not be received if the signal receiver on the air-conditioner is exposed to direct sunlight or other bright light. If so, cut out the sunlight or reduce the other light.
If the unit is operated for a long time in high humidity, moisture may form on the air outlet grills and start dripping.
20
When to contact your distributor without delay
Turn off the power switch immediately and inform your dealer in any of the following situations:
The fuse or switch blows continu­ously.
Fuse often blows.
The cable becomes extremely hot. The covering of the cable is cracked.
CAUTION
If the power cord becomes damaged, ask your dealer or a qualified engineer to install the replacement to avoid accidents.
The TV, radio or other equipment starts to malfunction.
When faulty movement is observed when the ON/OFF but­ton is pressed, even after turning off the power switch and restarting the operation after 3 minutes, the faulty move­ment does not disappear.
A switch does not activate properly. You hear a strange noise during opera-
The RUN and TIMER lights on the unit indication section blink quickly (0.5 sec. ON; 0.5 sec. OFF) and dont work.
3 minutes go by, but, why ...
tion.
Self diagnosis function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of each function as follows:
TIMER light ON
RUN light
1 time flash
2 time flash
6 time flash
Description of trouble
Heat exchanger sensor error
Room temperature sensor error
Indoor fan motor error
Cause
Broken heat exchanger sensor wire, poor connector connection
Broken room temperature sensor wire, poor connector connection
Defective fan motor, poor connector connection
RUN light keeps flashing
RUN light ON
TIMER light
1 time flash
2 time flash
4 time flash Discharge pipe sensor error Broken discharge pipe sensor wire, poor connector connection.
2 time flash
5 time flash
6 time flash
Outdoor temperature sensor error Broken outdoor sensor wire, poor connector connection
Outdoor heat exchanger fluid pipe sensor error
Abnormality of outdoor unit Compressor failure, overload operation
Over heat of compressor
Error of signal transmission
Broken heat exchanger fluid pipe sensor wire, poor connector connection
Gas shortage, defective discharge pipe sensor, closed service valve
Defective power supply, Broken signal wire, defective in/outdoor unit boards
21
AIR-CONDITIONING & REFRIGERATION SYSTEMS HEADQUARTERS
16-5, 2-Chome, Kounan, Minato-ku, Tokyo, 108-8215, Japan Fax: (03) 6716-5926
MITSUBISHI HEAVY INDUSTRIES EUROPE, LTD. AIR-CONDITIONER DIVISION
3rd Floor Thavies Inn House 3-4 Holborn Circus London EC1N 2HA, ENGLAND Phone: 44(0)20 7842 8171 Fax: 44(0)20 7842 8104