Mitsubishi RM300CA-9W Datasheet

RM300CA-9W
MITSUBISHI FAST RECOVERY DIODE MODULES
RM300CA-9W
HIGH FREQUENCY USE
INSULATED TYPE
V
RRM Repetitive peak reverse voltage
.................... 450V
t
rr Reverse recovery time .............0.5µs
APPLICATION
Free wheel use, Welders
OUTLINE DRAWING & CIRCUIT DIAGRAM Dimensions in mm
4–R7
(19.4)
(18)
30 30
A1
86±0.25
K
100
A2
4–φ5.5 MOUNTING HOLES
55
41±0.25
3–M8 NUTS
A1
K
A2
(7)
LABEL
(28.5)
30
CIRCUIT DIAGRAM
Aug.1999
ABSOLUTE MAXIMUM RATINGS (Tj=25°C)
Symbol
RRM
V
VR (DC)
Repetitive peak reverse voltage
Reverse DC voltage
Parameter
MITSUBISHI FAST RECOVERY DIODE MODULES
RM300CA-9W
HIGH FREQUENCY USE
INSULATED TYPE
Voltage class
9W
450
360
Unit
V
V
Symbol
DC
I
IFSM
2
t
I
Tj
Tstg
Visol
DC current
Surge (non-repetitive) forward current
2
t
I
Junction temperature
Storage temperature
Isolation voltage
Mounting torque
Weight
Parameter
for fusing
ELECTRICAL CHARACTERISTICS
Symbol
I
RRM
VFM
trr
Qrr
Rth (j-c)
Rth (c-f)
Repetitive reverse current
Forward voltage
Reverse recovery time
Reverse recovery charge
Thermal resistance
Contact thermal resistance
Insulation resistance
Parameter
Conditions
Resistive load, T
One half cycle at 60Hz, peak value
Value for one cycle of surge current, t
Charged part to case
Main terminal screw M8
Mounting screw M5
Typical value
j=150°C, VRRM applied
T
j=25°C, IFM=300A
T
I
F=300A, Tj=25°C. di/dt=–600A/µs, VR=300V
Junction to case
Case to fin, with thermal compound
Main terminal to case
C=119°C
w=8.3ms, Tj=25°C Start
Test conditions
Min.
10
Ratings
300
6000
1.5 × 10
–40~+150
–40~+125
2500
8.83~10.8
1.47~1.96
460
Limits
Typ.
Unit
A
A
5
Max.
40
1.2
0.5
50
0.085
0.08
2
A
°C °C
V
N·m
N·m
g
Unit
mA
V
µs
µC °C/W °C/W
M
s
Aug.1999
Loading...
+ 1 hidden pages