MITSUBISHI INTELLIGENT POWER MODULES
PM300DVA120
FLA T-BASE TYPE
INSULA TED P ACKAGE
B
E
R
"S" NUTS (3 TYP)
C
U
Y
C2E1 E2 C1
K K K
NC
V
43 2 5
GND
SINK
NR N1 NO N1
i
C
SFO
I
N
OUT2
SENS OUT1
RG
R
AMP
A
D
N
P
Q Q P N
FSC
RFO RFO
V
CC
TEMP
TH
RREF
V
1
V
PC
4325
i
GND
SINK
5
4
3
2
1
F J
5
4
3
2
1
SFO
I
N
OUT2
SENS OUT1
RG
"T" (4 TYP.)
W SQ PIN
(10 PLS)
Xφ (2 PLS)
L
R
AMP
H
V
PO P1 PR P1
V
CC
TEMP
Z
M
VFSC
1
G
Description:
Mitsubishi Intelligent Power Modules are isolated base modules designed for power switching applications operating at frequencies to
20kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free-wheel
diode power devices.
Features:
u Complete Output Power
Circuit
u Gate Drive Circuit
u Protection Logic
– Short Circuit
– Over T emperature
– Under Voltage
E2
C2E1 C1
Outline Drawing and Circuit Diagram
Dimensions Inches Millimeters
A 4.72 120.0
B 3.54 90.0
C 1.34 +0.04/-0.02 34 +1.0/-0.5
D 4.17±0.010 106.0±0.25
E 2.99±0.010 76.0±0.25
F 1.52 38.5
G 0.16 4.0
H 0.16 4.01
J 0.40 10.16
K 0.71 18.0
L 1.22 31.0
M 1.73 44.0
Dimensions Inches Millimeters
N 0.12 3.0
P 1.22 31.0
Q 1.10 28.0
R 0.12 3.0
S M8 Metric M8
T 0.26 Dia. Dia. 6.5
U 1.29 32.8
V 0.10 2.54
W 0.025 SQ 0.64 SQ
X 0.14 Dia. 3.5 Dia.
Y 0.26 Dia. Dia. 6.5
Z 1.79 45.5
Applications:
u Inverters
u UPS
u Motion/Servo Control
u Power Supplies
Ordering Information:
Example: Select the complete
part number from the table below
-i.e. PM300DVA120 is a 1200V,
300 Ampere Intelligent Power Module.
Type Current Rating V
Amperes Volts (x 10)
PM 300 120
CES
Sep.1998
MITSUBISHI INTELLIGENT POWER MODULES
PM300DVA120
FLA T-BASE TYPE
INSULA TED PACKAGE
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Ratings Symbol PM300DVA120 Units
Power Device Junction Temperature T
Storage T emperature T
Case Operating Temperature T
Mounting Torque, M6 Mounting Screws — 3.92 ~ 5.88 N · m
Mounting Torque, M6 Main Terminal Screws — 3.92 ~ 5.88 N · m
Module Weight (Typical) — 720 Grams
Supply Voltage (Applied between C1-E2) V
Supply Voltage Protected by SC (VD = 13.5 ~16.5V, Inverter Part, Tj = 125°C Start) V
Isolation Voltage (Main Terminal to Baseplate, AC 1 min.) V
j
stg
C
CC(surge)
CC(prot.)
iso
Control Sector
Supply Voltage (Applied between VP1-VPC, VN1-VNC)V
Input Voltage (Applied between CP1-VPC, CN1-VNC)V
Fault Output Supply Voltage (Applied between FPO-VPC, FNO-VNC)VFO20 Volts
Fault Output Current (Sink Current at FPO, FNO Terminal) I
D
CIN
FO
-20 to 150 °C
-40 to 125 °C
-20 to 100 °C
1000 Volts
800 Volts
2500 Vrms
20 Volts
10 Volts
20 mA
IGBT Inverter Sector
Collector-Emitter Voltage (VD = 15V, V
Collector Current, (TC = 25°C) I
Peak Collector Current, (TC = 25°C) I
Collector Dissipation (TC = 25°C) P
= 5V) V
CIN
CES
C
CP
C
1200 Volts
300 Amperes
600 Amperes
1380 Watts
Sep.1998