Mitsubishi PM300DSA060 Datasheet

MITSUBISHI INTELLIGENT POWER MODULES
PM300DSA060
FLA T-BASE TYPE
INSULA TED P ACKAGE
N SIDE P SIDE
VN1
A B
GG
J
C2E1 E2 C1
C
N
T - DIA. (2 TYP.)
N
21 345
P
21345
S (8 TYP.)
1. SNR
2. CN1
3. VNC
4. FNO
5.
DH
VP1
1. SPR
2. CP1
3. VPC
4. FPO
5.
Q - DIA. (2 TYP.)
E
R - THD. (3 TYP.)
F
VP1
FPO SPR
CP1
VPC
VN1
FNO SNR CN1 VNC
VCC
FO SR IN
GND
VCC
FO SR IN
GND
Outline Drawing and Circuit Diagram
Dimensions Inches Millimeters
A 4.33 110.0 B 3.66±0.010 93.0±0.25 C 2.20 56.0 D 2.01 51.0 E 1.14 +0.04/-0.02 29.0 +1/-0.5 F 1.02 26.0 G 0.98 25.0 H 0.90 23.0
J 0.85 21.5
M
0.64 MM SQ. PIN (10 TYP.)
TEMP OUT1 OUT2 SENS SINK
TEMP OUT1 OUT2 SENS SINK
K
P
C1
C2E1
E2
L
Dimensions Inches Millimeters
K 0.55 14.0
L 0.51 13.0 M 0.47 12.0 N 0.33 8.5
P 0.28 7.0 Q 0.22 Dia. Dia. 5.5 R M5 Metric M5
S 0.100 2.54
T 0.08 Dia. Dia. 2.0
Description:
Mitsubishi Intelligent Power Mod­ules are isolated base modules de­signed for power switching applica­tions operating at frequencies to 20kHz. Built-in control circuits pro­vide optimum gate drive and pro­tection for the IGBT and free wheel-diode power devices.
Features:
u Complete Output Power
Circuit
u Gate Drive Circuit u Protection Logic
– Short Circuit – Over Current – Over T emperature – Under Voltage
Applications:
u Inverters u UPS u Motion/Servo Control u Power Supplies
Ordering Information:
Example: Select the complete part number from the table below
-i.e. PM300DSA060 is a 600V, 300 Ampere Intelligent Power Mod­ule.
Type Current Rating V
Amperes Volts (x 10)
PM 300 60
CES
Sep.1998
MITSUBISHI INTELLIGENT POWER MODULES
PM300DSA060
FLA T-BASE TYPE
INSULA TED PACKAGE
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Ratings Symbol PM300DSA060 Units Power Device Junction Temperature T Storage T emperature T Case Operating Temperature T Mounting Torque, M5 Mounting Screws 1.47 ~ 1.96 N · m Mounting Torque, M5 Main Terminal Screws 1.47 ~ 1.96 N · m Module Weight (Typical) 430 Grams Supply Voltage Protected by OC and SC (VD = 13.5 - 16.5V , Inverter Part) V Isolation Voltage (Main Terminal to Baseplate, AC 1 min.) V
j
stg
C
CC(prot.)
iso
Control Sector
Supply Voltage (Applied between VP1-VPC, VN1-VNC)V Input Voltage (Applied between CP1-VPC, CN1-VNC)V Fault Output Supply Voltage (Applied between Fpo-Vpc and Fno-Vnc)VFO20 Volts Fault Output Current (Sink Current at FPO, FNO T erminal) I
D
CIN
FO
-20 to 150 °C
-40 to 125 °C
-20 to 100 °C
400 Volts
2500 Vrms
20 Volts 10 Volts
20 mA
IGBT Inverter Sector
Collector-Emitter Voltage (VD = 15V, V Collector Current, (TC = 25°C) I Peak Collector Current, (TC = 25°C) I Supply Voltage (Applied between C1 - E2) V Supply Voltage, Surge (Applied between C1 - E2) V Collector Dissipation P
= 5V) V
CIN
CC(surge)
CES
C
CP
CC
C
600 Volts 300 Amperes 600 Amperes 450 Volts 500 Volts 960 Watts
Sep.1998
Loading...