Mitsubishi PCA-A42GA1, PCA-A42GA, PCA-A36GA1, PCA-A36GA, PCA-A30GA2 Owner’s Manual

...
B"_ EL.ECTRIC
Air-Conditioners
Indoor unit
PLA-A.AA PKA-A.GA/PKA-A.GAL
PKA-A.FA/PKA-A.FAL PCA-A.GA
OPERATION MANUAL
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto,
Contents
1. Safety Precautions .............................................................. 2
2. Parts Names ....................................................................... 2
3. Screen Configuration .......................................................... 6
4. Setting the Day of the Week and Time ............................... 6
5. Operation ............................................................................ 6
6. Timer ................................................................................... 8
1. Safety Precautions
I_ Before installing the unit, make sure you read all the
"Safety Precautions".
I_ The"Safety Precautions" provide very important points
regarding safety. Make sure you follow them.
I_ Please report to or take consent by the supply author-
ity before connection to the system.
/_ Warning:
The unit must not be installed by the user. Ask the dealer or an
authorized company to install the unit. If the unit is installed im- properly, water leakage, electric shock or fire may result.
Do not stand on, or place any items on the unit.
Do not splash water over the unit and do not touch the unit with
wet hands. An electric shock may result.
Do not spray combustible gas close to the unit. Fire may result.
Do not place a gas heater or any other open-flame appliance where
it will be exposed to the air discharged from the unit. Incomplete combustion may result.
Do not remove the front panel or the fan guard from the outdoor
unit when it is running.
7. Other Functions ................................................................ 11
8. Function Selection ............................................................ 12
9. Emergency Operation for Wireless Remote-controller ..... 16
10. Care and Cleaning ............................................................ 16
11. Trouble Shooting ............................................................... 16
12. Specifications .................................................................... 18
Symbols used in the text
/_ Warning: Describes precautions that should be observed to prevent danger of
injury or death to the user. z_ Caution:
Describes precautions that should be observed to prevent damage
to the unit.
Symbols used in the illustrations
(_ : Indicates apart which must be grounded.
When you notice exceptionally abnormal noise or vibration, stop
operation, turn off the power switch, and contact your dealer.
Never insert fingers, sticks etc. into the intakes or outlets.
If you detect odd smells, stop using the unit, turn off the power
switch and consult your dealer. Otherwise, a breakdown, electric shock or fire may result.
This air conditioner is NOT intended for use by children or infirm
persons without supervision.
Young children must be supervised to ensure that they do not play
with the air conditioner.
If the refrigeration gas blows out or leaks, stop the operation of the
air conditioner, thoroughly ventilate the room, and contact your dealer.
Z_ Caution:
Do not use any sharp object to push the buttons, as this may dam-
age the remote controller.
Never block or cover the indoor or outdoor unit's intakes or out-
lets.
Disposing of the unit
When you need to dispose of the unit, consult your dealer.
2. Parts Names
Indoor Unit
PLA-A.AA PKA-A.GAL PKA-A.FAL
Fan steps 4 steps 4 steps 2 steps 4 steps
Vane Auto with swing Auto with swing Auto with swing Auto with swing
Louver - Manual Manual Manual Filter Long-life Normal Normal Long-life
Filter cleaning indication 2,500 hr 100 hr 100 hr 2,500 hr
PKA-A.GA PKA-A.FA PCA-A.GA
2
2. Parts Names
PLA-A.AA 4-way Ceiling Cassette
Filter _Vane
Air intake
PKA-A.GA/PKA-A.GAL Wall Mounted
Filter
Air outlet
Air intake
Louver
PKA-A.FA/PKA-A.FAL Wall Mounted
Louver Air outlet
PCA-A.GA Ceiling Suspended
Air outlet
Vane
Air outlet
Air intake
Filter
_ane
Louver
Vane r
Air intake
3
2. Parts Names
Wired Remote-Controller
I Display Section I
Orpurposes of this explanation,_ IIparts of the display are shown I
lit.Duringactualoperation, only I
e relevant itemswill be lit. /
Identifies the current operation
Shows the operating mode, etc. * Multilanguage display is sup-
ported.
"Centrally Controlled" indicator Indicates that operation of the re-
mote controller has been prohib- ited by a master controller.
"Timer is Off" indicator Indicates that the timer is off.
Temperature Setting
Shows the targettemperature.
/
Day-of-Week
Shows the current day of the week.
Time/Timer Display
Shows the current time, unless the simple or Auto Off timer is set.
If the simple or Auto Off timer is set, shows the time remaining.
_, MITSUBISHI ELEITRIC
TiME SUN MON TUE..WED THU FRI SAT I _ _[_]
TIMER El L/ " El L I Hr ON I
AFTER I II I " I II I AFTEROFF JOl
I
1 I
Up/Down Air Direction indica- Room Temperature display tor Shows the room temperature. The room
The indicator '% shows the direc- temperature display range is 8-39°C. tion of the outcoming airflow. The display flashes if the temperature
"One Hour Only" indicator Displayed if the airflow is set to Louver display
weakand downward during COOL Indicates the action of the swing louver. or DRY mode. (Operation varies Does not appear if the louver is station-
according to model.) ary. The indicator goes off after one
hour, at which time the airflow di- (_) (Power On indicator) rection also changes. Indicates that the power is on.
is less than 8 °C or 39 °C or more.
"Sensor" indication Displayed when the remote controller
sensor is used.
m
"Locked" indicator Indicates that remote controller but-
tons have been locked.
"Clean The Filter" indicator
Comes on when it is time to clean the filter.
Timer indicators
The indicator comes on if the corre- sponding timer is set.
Fan Speed indicator
Shows the selected fan speed.
Ventilation indicator Appears when the unit is running in
Ventilation mode.
Operation Section
_Set Temperature buttons
Down
up
I Timer Menu button
(Monitor/Set button)
Mode button (Return button)
I Set Time buttons
Back
(_ Ahead
I imer On/Off button _}_(Set Day button)
Opening the door.
I
ON/OFF button
)eed button
MITSUBISHI ELECTRIC
Filter _ button
J
-- __ TEMP.
(2D
I_--!_00638_ C)MENU _ON/OFF FILTER
_. ONSETDAYI I :-_=_ 3_:.lJ CHECKTEST
i
@ 0 q/OFF
o
Built-in temperature sensor
(<Enter> button)
Test Run button J
[__ heck button (Clear button)
Airflow Up/Down button ;
_ (L?VorpbeUatti°nnbutt°n)1
(_ To preceding operation
number.
--I (Vz_nt_)_P:°ntib°Lttbuntton)1 (_To next operation
number.
%
Note:
"PLEASE WAIT" message This message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the unit is recovering from a power failure,
"NOT AVAILABLE" message This message is displayed if a button is pressed to operate a function that the indoor unit does not have,
If a single remote controller is used to simultaneously operate multiple indoor units that are different models, this message will not be displayed if
any of the indoor units is equipped with the function,
4
2. Parts Names
Wireless Remote-Controller
Transmission area
( Remote controller display
* For explanation purposes, all of the items
that appear in the display are shown.
* All items are displayed when the Reset
button is pressed.
(oN,OFFbutton)
I Set Temperature buttons
Fan Speed button (Changes fan speed) ,)
Airflow button (Changes up/down airflow direction) ")_
I Mode button (Changes operation mode)
Check button
( Test Run button _)
When using the wireless remote controller, point it towards the receiver on the indoor unit.
If the remote controller is operated within approximately two minutes after power is supplied to the indoor unit, the indoor unit may beep twice as the unit is performing the initial auto-
matic check.
The indoor unit beeps to confirm that the signal transmitted from the remote controller has
been received. Signals can be received up to approximately 7 meters in a direct line from the indoor unit in an area 45° to the left and right of the unit. However, illumination such as fluorescent lights and strong light can affect the ability of the indoor unit to receive signals.
If the operation lamp near the receiver on the indoor unit is flashing, the unit needs to be inspected. Consult your dealer for service.
Handle the remote controller carefully! Do not drop the remote controller or subject it to
strong shocks. In addition, do not get the remote controller wet or leave it in a location with
high humidity.
To avoid misplacing the remote controller, install the holder included with the remote con-
troller on a wall and be sure to always place the remote controller in the holder after use.
Outdoor unit
Transmission indicator Timer indicator
Operation areas
Timer Off button 1
Timer On button 1
Hour button
Minute button
( Set Time button (Sets the time) _
Louver button (Changes left/right airflow direction))
Battery installation/replacement
1. Remove the top cover, insert two AAA batter- ies, and then install the top cover.
Top cover r(_
Two AAA batteries
Insert the negative (-) 1
end of each battery I first. Install the batter-
ies in the correct direc- tons (+, -)
2. Press the Reset button.
Ref. Pipes _
Indoor-Outdoor
_iiiiiii1iiiiiiiiiii_ii_jiiiiIIjiiIIjiiIIjiiIIjiiIIjiiIIjiiWiiiijiiiijiiiijiiiijiiiijiiiijiiiijiiiijiiiijiiiijiiiiji_
Connection wire
Panel
Powe r
Press the Reset button with an object that has
a narrow end.
iil Earth
///////_///////
5
3. Screen Configuration
FunctionSelectionofremotecontroller Set Day/Time
l®l 1o
Standard Control Screens
4. Setting the Day of the Week and Time
Dayof theWeek &
Time display
<Screen Types>
For details on setting the language for the remote controller display, refer
to section 8. Function Selection. The initial language setting is English.
Function Selection of remote controller: Set the functions and ranges available to the re-
mote controller (timer functions, operating restric- tions, etc.)
Set Day/Time: Set the current day of the week or time.
Standard Control Screens:
View and set the air conditioning system's oper-
ating status
Timer Monitor: View the currently set timer (weekly timer, sim- ple timer, or Auto Off timer)
Timer Setup: Set the operation of any of the timers (weekly timer, simple timer, or Auto Off timer).
<How to change the screen>
@ :Hold down both the Mode button and the Timer On/Off button for 2
seconds.
(_ :Press the Timer Menu button. ©:Press the Mode (Return) button. @ :Press either of the Set Time buttons (V or A).
Day of the Week Setting
.......... " -_'==--_t_;:i_ ....
=lm.e:=_:_,,=,,,=.,.,.u,_,.,_,,_..... I...........................] _ Time Setting
_TEMP _ON/OFF
l@Iotl t)MINU _O_OFF _=1_ % FILTER
®
®
Q d_
Note:
The day and time will not appear if clock use has been disabled at Function Selection of remote controller.
5. Operation
% % %
% ®
5.1. Turning ON/OFF
<To Start Operation>
Press the ON/OFF button (_.
The ON lamp _ and the display area come on.
Note:
When the unit is restarted initialsettings are as follows.
Remote Controller settings
Mode Last operation mode
Temperature setting Last set temperature
Fan speed Last set fan speed
COOL or DRY Horiz. outlet*
Airflow up/down Mode HEAT Last setting
It will be set by last setting for wired remote controller.
FAN Horiz. outlet *
1. Press the V or A Set Time button @ to show display _.
2. Press the Timer On/Off (Set Day) button (_ to set the day.
* Each press advances the day shown at _: Sun -_ Mon -_ ... -_ Fri -_
Sat.
3. Press the appropriate Set Time button @ as necessary to set the time.
*As you hold the button down, the time (at _) will increment first in
minute intervals, then in ten-minute intervals, and then in one-hour in- tervals.
4. After making the appropriate settings at Steps 2 and 3, press the Filter
button (_ to lock in the values.
%
®
6
5. Operation
<To Stop Operation>
Press the ON/OFF button (_ again.
The ON lamp _ and the display area go dark.
Note:
Even if you press the ON/OFF button immediately after shutting down the op- eration is progress, the air conditioner will not start for about three minutes. This is to prevent the internal components from being damaged.
5.2. Mode select
Press the operation mode (l-I_a_0) button _) and select the opera- tion mode [_.
-_ _ Cooling mode 6 Drying mode
Fan mode
Q Heating mode
I--I Automatic (cooling/heating) mode
-- _ Ventillation mode
Only indicated on the following condition
Wired remote controller used
LOSSNAY connected
Automatic operation
According to a set temperature, cooling operation starts if the room tem- perature is too hot and heating operation starts if the room temperature
is too cold.
During automatic operation, if the room temperature changes and re- mains 2 °C, 4 °F or more above the set temperature for 15 minutes, the
air conditioner switches to cooling mode. In the same way, if the room temperature remains 2 °C, 4 °F or more below the set temperature for
15 minutes, the air conditioner switches to heating mode.
Cooling mode 15 minutes (switches
._ from heating to cooling)
_'_-._._ ........ Set temperature-2°C, -4°F
15 minutes (switches
fromcooling to heating)
Because the room temperature is automatically adjusted in order to maintain a fixed effective temperature, cooling operation is performed a
few degrees warmer and heating operation is performed a few degrees cooler than the set room temperature once the temperature is reached
(automatic energy-saving operation).
,--?t_' \ Set temperature +2°C, +4°F
Set temperature
!
5.3. Temperature setting
To decrease the room temperature:
Press QD button _) to set the desired temperature.
The selected temperature is displayed _.
To increase the room temperature: Press _ button _) to set the desired temperature.
The selected temperature is displayed _.
Available temperature ranges are as follows: Cooling/Drying: 19 - 30 °C, 67 - 87 °F Heating: 17 - 28 °C, 63 - 83 °F Automatic: 19 - 28 °C, 67 - 83 °F
The display flashes either 8 °C - 39 °C, 46 °F - 102 °F to inform you if the
room temperature is lower or higher than the displayed temperature.
5.4. Fan speed setting
Press the Fan Speed button (_) as many times as necessary while the
system is running.
Each press changes the force. The currently selected speed is shown at _.
The change sequence, and the available settings, are as follows.
FAN SPEED Display
4-speed
2-speedmodel _ _d" _dd||
Note:
The number of available fan speeds depends on the type of unit connected. Note also that some units do not provide an "Auto" setting.
In the following cases, the actual fan speed generated by the unit will differ from the speed shown the remote controller display.
1. While the display is showing "STAND BY" or "DEFROST".
2. When the temperature of the heat exchanger is low in the heating mode.
(e.g. immediately after heating operation starts)
3. In HEAT mode, when room temperature is higher than the temperature
setting.
4. When the unit is in DRY mode.
Speed 1 Speed 2 Speed 3 Speed 4
5.5. Airflow direction setting
<To Change the Airflow's Up/Down Direction>
With the unit running, press the Airflow Up/Down button _) as necessary.
Each press changes the direction. The current direction is shown at _.
The change sequence, and the available settings, are as follows.
Horiz. 1 2 3 Swing
Display
Note that during swing operation, the directional indication on the screen does not change in sync with the directional vanes on the unit.
* Some models do not support directional settings.
Note:
Available directions depend on the type of unit connected. Note also that some units do not provide an "Auto" setting.
In the following cases, the actual air direction will differ from the direction indicated on the remote controller display.
1. While the display is showing "STAND BY" or "DEFROST".
2. Immediately after starting heater mode (while the system is waiting for
the mode change to take effect).
3. In heat mode, when room temperature is higher than the temperature set-
ting.
7
5. Operation
<To Change the Right/Left Air Direction>
Press the louver button (_ as necessary,
The louver image _ appears, Each press of the button switches the setting as follows,
_._%_ _ No display
(Stop)
(ON) (OFF)
During swing operation, the arrow dis- play move to the left and right.
5.6. Ventillation
For LOSSNAY combination
5.6.1. For Wired Remote-controller
To run the ventilator together with the indoor unit:
Press the ON/OFF button (_.
The Vent indication appears on the screen (at _). The ventilator will now automatically operate whenever the indoor unit is running.
6. Timer
6.1. For Wired Remote-controller
You can use Function Selection of remote controller to select which of three types of timer to use: (_ Weekly timer, _) Simple timer, or (_) Auto Off
timer.
6.1.1. Weekly Timer
The weekly timer can be used to set up to eight operations for each day of the week.
Each operation may consist of any of the following: ON/OFF time
together with a temperature setting, or ON/OFF time only, or tempera- ture setting only.
When the current time reaches a time set at this timer, the air
conditioner carries out the action set by the timer.
Time setting resolution for this timer is 1 minute.
Note:
"1. WeeklyTimer/SimpleTimer/Auto OffTimer cannot be used atthe same time. *2. The weekly timer will not operate when any of the following conditions is in
effect. The timer feature is off; the system is in an malfunction state; atest run is
in progress; the remote controller is undergoing self-check or remote con- troller check; the user is in the process of setting afunction; the user is in the process of setting the timer; the user is in the process of setting the current day of the week or time; the system is under central control. (Spe- cifically, the system will not carry out operations (unit on, unit off, or tem- perature setting) that are prohibited during these conditions.)
OperationNo.
[] [] [] Day Setting
To run the ventilator independently:
Press the Mode button (_) until _ appears on the display. This will cause the ventilator to start.
To change the ventilator force:
Press the Ventilation button (_ as necessary.
Each press toggles the setting, as shown below.
.--'-"
Low High
5.6.2. For Wireless Remote-controller
The ventillator will automatically operate when the indoor unit turns on.
No indication on the wireless remote controller.
<How to Set the Weekly Timer>
1, Be sure that you are at a standard control screen, and that the weekly
timer indicator _ is shown in the display,
2, Press the Timer Menu button @, so that the "Set Up" appears on the
screen (at _), (Note that each press of the button toggles the display between "Set Up" and "Monitor",)
3, Press the Timer On/Off (Set Day) button (_ to set the day, Each press
advances the display at _ to the next setting, in the following sequence: "Sun Mon Tues Wed Thurs Fri Sat"-> "Sun" -> ...-> "Fri" -> "Sat" -> "Sun
Mon Tues Wed Thurs Fri Sat"...
4. Press the V or/k Operation button ((_ or (_) as necessary to select the appropriate operation number (1 to 8) _.
* Your inputs at Steps 3 and 4 will select one of the cells from the matrix
illustrated below. (The remote-controller display at left shows how the display would
appear when setting Operation 1 for Sunday to the values indicated
below.)
Setup Matrix
Op No Sunday Monday .. Saturday
8:30
No. 1 •ON
73 F
No. 8
MITS IBISHI ELECTF C
_TEMP.
2
<Operation 1 settings for Sunday> I
Start the air conditioner at 8:30, with I Turn off the air conditioner at 10:00. the temperature set to 73 °E
<Operation
i J
settings
for
every day>
I
Note: Bysetting the day to "Sun MonTuesWedThurs Fri Sat", you can set the same
operation to be carried out at the same time everyday.
(Example: Operation 2 above, which is the same for all days of theweek.)
<Setting the Weekly Timer>
Showsthe time _ _ Shows theselected operation (ONor OFF)
setting / * Doesnotappear if operation is notset.
[
Showsthe temperature setting
Fn'3 / _ * Does notappear iftemperature is not
- set.
5. Press the appropriate Set Time button @ as necessary to set the
desired time (at _).
As you holdthe button down, the time first increments inminute inter- vals, then in ten-minute intervals, and then in one-hour intervals.
6. Press the ON/OFF button (_ to select the desired operation (ON or OFF), at _.
Each press changes the next setting, in the following sequence:
No display (no setting) -> "ON" -> "OFF"
8
6. Timer
7, Press the appropriate Set Temperature button (_ to set the desired
temperature (at _), * Each press changes the setting, in the following sequence: No
display (no setting) <=>75 <=>77 <=>,,, <_ 84 <=>86 <=>54 <=>,,, <_ 73 <=>No display.
(Available range: The range for the setting is 12 °C, 54 °F to 30 °C, 86 °E The actual range over which the temperature can be con- trolled, however, will vary according to the type of the connected
unit,)
8, After making the appropriate settings at Steps 5, 6 and 7, press the
Filter _ button _) to lock in the values, To clear the currently set values for the selected operation, press and quickly release the Check (Clear) button _ once,
* The displayed time setting will change to "--:--", and the On/Off
and temperature settings will all disappear,
(To clear all weekly timer settings at once, hold down the Check
(Clear) button _ for two seconds or more, The display will begin flashing, indicating that all settings have been cleared,)
Note: Your new entries will be cancelled if you press the Mode (Return) button
(_) before pressing the Filter 4J button _).
If you have set two or more different operations for exactly the same time, only the operation with the highest Operation No. will be carried
out.
9, Repeat Steps 3 to 8 as necessary to fill as many of the available cells
as you wish,
lO,Press the mode (Return) button (_ to return to the standard control
screen and complete the setting procedure,
11,To activate the timer, press the Timer On/Off button (_, so that the
"Timer Off" indication disappears from the screen, Be sure that the "Timer Off" indication is no longer displayed.
* If there are no timer settings, the "Timer Off" indication will flash on
the screen,
6.1.2. SimpleTimer
You can set the simple timer in any of three ways,
Start time only: The air conditioner starts when the set time has elapsed,
Stop time only: The air conditioner stops when the set time has elapsed,
Start & stop times: The air conditioner starts and stops at the respective elapsed times,
The simple timer (start and stop) can be set only once within a 72-hour period, The time setting is made in hour increments,
Note: "1. WeeklyTimer/SimpleTimer/Auto OffTimer cannot be used atthe same time.
*2. The simple timer will not operate when any of the following conditions is in
effect. The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check; the user is in the process of selecting afunction; the user is in the process of setting the timer; the system is under central control. (Under these con- ditions, On/Off operation is prohibited.)
_ MITSUBISHI ELECTRIC
_,t[TEMP.
_ ON/OFF
U
J
<How to View the Weekly Timer Settings>
_ Timer Settings
1, Be sure that the weekly timer indicator is visible on the screen (at [_),
2, Press the Timer Menu button @ so that "Monitor" is indicated on the
screen (at [_),
3, Press the Timer On/Off (Set Day) button (_ as necessary to select
the day you wish to view,
4, Press the V or/k Operation button ((_ or (_))as necessary to change
the timer operation shown on the display (at [_), * Each press will advance to the next timer operation, in order of
time setting,
5, To close the monitor and return to the standard control screen, press
the Mode (Return) button (_,
<To Turn Off the Weekly Timer>
Press the Timer On/Off button (_ so that "Timer Off" appears at _,
<To Turn On the Weekly Timer>
Press the Timer On/Off button (_ so that the "Timer Off" indication (at _)
goes dark,
<How toSet the SimpleTimer>
_ Timer Setting
J
Action (On or Off) * "-- _" is displayed if there is no
setting.
1, Be sure that you are at a standard control screen, and that the simple
timer indicator is visible in the display (at _), When something other than the Simple Timer is displayed, set it to SIMPLE TIMER using the function selection of remote controller (see 8,[4]-3 (3)) timer function setting,
2, Press the Timer Menu button @, so that the "Set Up" appears on the
screen (at _), (Note that each press of the button toggles the display between "Set Up" and "Monitor",)
3, Press the ON/OFF button (_ to display the current ON or OFF simple
timer setting, Press the button once to display the time remaining to ON, and then again to display the time remaining to OFF, (The ON/OFF indication appears at _).
"ON" timer:
The air conditioner will start operation when the specified number of hours has elapsed.
"OFF" timer:
The air conditioner will stop operation when the specified number of hours has elapsed.
4. With "ON" or "OFF" showing at _: Press the appropriate Set Time button
@ as necessary to set the hours to ON (if "ON" is displayed) or the hours
to OFF (if "OFF" is displayed) at _.
Available Range: 1 to 72 hours
5. To set both the ON and OFF times, repeat Steps 3 and 4. * Note that ON and OFF times cannot be set to the same value.
6. To clear the current ON or OFF setting: Display the ON or OFF setting (see step 3) and then press the Check (Clear) button _ so that the time setting clears to "--" at _. (If you want to use only an ON setting or only an OFF setting, be sure that the setting you do not wish to use is shown
as "--',)
9
6. Timer
7, After completing steps 3 to 6 above, press the Filter _ button (_ to lock
in the value,
Note:
Your new settings will be cancelled if you press the Mode (Return) button (_)
before pressing the Filter _fJ button (_).
8. Press the Mode (Return) button _) to return to the standard control screen.
9. Press the Timer On/Off button (_)to start the timer countdown. When the timer is running, the timer value is visible on the display. Be sure that the
timer value is visible and appropriate.
<Viewing the Current Simple Timer Settings>
_ Timer Setting
1. Be sure that the simple timer indicator is visible on the screen (at _).
2. Press the Timer Menu button @, so that the "Monitor" appears on the screen (at _).
If the ON or OFF simple timer is running, the current timer value will
appear at _.
If ON and OFF values have both been set, the two values appear
alternately.
3. Press the Mode (Return) button _) to close the monitor display and return to the standard control screen.
<To Turn Off the Simple Timer...>
Press the Timer On/Off button (_ so that the timer setting no longer ap- pears on the screen (at _).
%
1
. .... ..,
Example 2:
Start the timer, with OFF time is sooner than ON time ON Setting: 5 hours OFF Setting: 2 hours
I
4
:,,_-/ AFaR ,
i
-At Timer Start Display shows the timer's OFF setting (hours
remaining to OFF).
At 2 hours after timieer s_art
"Display changes to show the timer's ON setting
(hours remaining to ON). The time displayed is ON setting (5 hours) -
OFF setting (2 hours) = 3 hours.
At 5 hours after timer start The air conditioner comes on, and will continue
to run until someone turns it of/.
6.1.3. Auto OffTimer
This timer begins countdown when the air conditioner starts, and shuts the air conditioner off when the set time has elapsed.
Available settings run from 30 minutes to 4 hours, in 30-minute intervals.
Note:
"1. WeeklyTimer/SimpleTimer/Auto OffTimer cannot be used at the same time. *2. The Auto Off timer will not operate when any of the following conditions is
in effect. The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check; the user is in the process of selecting a function; the user is in the process of setting the timer; the system is under central control. (Under these con- ditions, On/Off operation is prohibited.)
_ MITSUBISHI ELECTF_
<To Turn On the Simple Timer...>
Press the Timer On/Off button (_ so that the timer setting becomes visible
ate.
,J,,
ICJ; L,C' ¢.d|i
qqoF
I"
Examples If ON and OFF times have both been set at the simple timer, operation and
display are as indicated below.
Example 1:
Start the timer, with ON time set sooner than OFF time ON Setting: 3 hours OFF Setting: 7 hours
__//H, oN
A_ER
®J Q SIM_LE
-At Timer Start Display shows the timer's ON setting (hours
remaining to ON).
_At_ hours a_er t_-mer_-art-')
- Display changes to show the timer's OFF set-
ting (hours remaining to OFF). The time displayed is OFF setting (7 hours) - ON setting (3 hours) = 4 hours.
At 7 hours after timer start The air conditioner goes off, and will remain off
until someone restarts it.
I_TEMP. (_'ON/OFF
@ ®
<How to Set the Auto Off Timer>
_ Timer Setting
1. Be sure that you are at a standard control screen, and that the Auto Off timer indicator is visible in the display (at _). When something other than the Auto Off Timer is displayed, set it to AUTO OFF TIMER using the function selection of remote controller (see
8.[4]-3 (3)) timer function setting.
2. Hold down the Timer Menu button @ for 3 seconds, so that the "Set Up" appears on the screen (at _). (Note that each press of the button toggles the display between "Set Up" and "Monitor".)
3. Press the appropriate Set Time button (_) as necessary to set the OFF time (at _).
4. Press the Filter _ button (_ to lock in the setting.
Note:
Your entry will be cancelled if you press the Mode (Return) button (_) before
pressingthe Filter 4J button(_).
10
5. Press the Mode (Retu m) button (_)to complete the setting procedu re and return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown immediately. Be sure to check that the timer setting appears cor-
rectly on the display.
6. Timer
<Checking the Current Auto Off Timer Setting>
_ Timer Setting
1. Be sure that the "Auto Off" is visible on the screen (at _).
2. Hold down the Timer Menu button @ for 3 seconds, so that "Monitor" is indicated on the screen (at _).
The timer remaining to shutdown appears at _.
3. To close the monitor and return to the standard control screen, press the Mode (Return) button _).
<To Turn Off the Auto Off Timer...>
Hold down the Timer On/Off button (_ for 3 seconds, so that "Timer Off"
appears (at _) and the timer value (at _) disappears.
I
Alternatively, turn off the air conditioner itself. The timer value (at _) will
disappear from the screen.
%
<To Turn On the Auto Off Timer...>
Hold down the Timer On/Off button (_ for 3 seconds. The "Timer Off" indication disappears (at _), and the timer setting comes on the display (at _).
Alternatively, turn on the air conditioner. The timer vahe will appear at _.
%
6.2. For wireless remote controller
(_ Press the _ or [_Z] button (TIMER SET).
Time can be set while the following symbol is blinking, OFF timer: @ G_O is blinking, ON timer: @ G_I is blinking,
(_) Use the [CCZ]and [ZCC]buttons to set the desired time, (_) Canceling the timer,
To cancel the OFF timer, press the _ button. To cancel the ON timer, press the _ button.
It is possible to combine both OFF and ON timers.
Pressing the (_ ON/OFF button of the remote controller during timer mode to stop the unit will cancel the timers.
If the current time has not been set, the timer operation cannot be used.
AUTOSTOP AUTOSTART
h rain
AUTOSTOP
7. Other Functions
7.1. Locking the Remote Controller Buttons (Operation function limit controller)
If you wish, you can lock the remote controller buttons. You can use the
Function Selection of remote controller to select which type of lock to use. (For information about selecting the lock type, see section 8, item [4]-2 (1)). Specifically, you can use either of the following two lock types.
(_ Lock All Buttons:
Locks all of the buttons on the remote controller.
(_) Lock All Except ON/OFF:
Locks all buttons other than the ON/OFF button. Note: The "Locked" indicator appears on the screen to indicate that buttons are cur-
rently locked.
[]
Lock Indicator
_TEMP.
\.... J \
D'_O Oo_ OMENU CON/OFF _111 7_ FILER
BACK MONITOR_SFT DAY "_=_ _.10HEOK TEST
PAR21MAA _ _)OLOCK VOPERATIONA }:t_R
_) ON/OFF
[]
®
<How to Lock the Buttons>
1. While holding down the Filter button _), press and hold down the ON/OFF button (_ for 2 seconds. The "Locked" indication appears on the screen (at _), indicating that the lock is now engaged. * If locking has been disabled in Function Selection of remote controller,
the screen will display the "Not Available" message when you press the buttons as described above.
If you press a locked button, the "Locked" indication (at _) will blink on
the display.
<How to Unlock the Buttons>
1. While holding down the Filter button (_, press and hold down the ON/ OFF button (_ for 2 seconds--so that the "Locked" indication disappears from the screen (at _).
/_/qF i
11
7. Other Functions
7.2. Error Codes indication
=_ MITSUBISHI ELECTRIC
.....:_ _1_ ,-- _-.
I II III I / I<.J
Indoor Unit's Refrig- Error Code Indoor Unit No.
erant Address I ]
Ifyouhaveenteredcontactnumbertobecanedintheeventofaproblem,thescreendisplaysthisnumber. AlternatingDisplay (Youcansetthisup underFunctionSelectionofremotecontroller.Forinformationrefertosection8.)
ON lamp (Flashing)
If the ON lamp and error code are both flashing: This means that the air conditioner is out of order and operation has been stopped (and cannot resume), Take note of the indicated unit number and error code, then switch off the power to the air conditioner and call your dealer or servicer,
When the Check button is pressed:
MITSUBISHI ELECTFUC
_)ON/OFF
Error Code
If only the error code is flashing (while the ON lamp remains lit): Operation is continuing, but there may be a problem with the system, In this case, you should note down the error code and then call your dealer or servicer for advice,
* If you have entered contact number to be called in the event of a problem, push the Check button to display it on the screen, (You can set this up under
Function Selection of remote controller, For information, refer to section 8,)
_,L MITSUBISHI ELECTRIC
(_)ON/OFF
8. Function Selection
Function selection of remote controller
The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when
needed.
Item 1 Item 2 Item 3 (Setting content)
1.Change Language Language setting to display Display in multiple languages is possible ("CHANGE
LANGUAGE")
2. Function limit (1) Operation function limit setting (operation lock) ("LOCKING Setting the range of operation limit (operation lock) ("FUNCTION FUNCTION") SELECTION")
3. Mode selection (1) Remote controller main/sub setting ("CONTROLLER MAIN/ Selecting main or sub remote controller ("MODE SELEC- SUB") * When two remote controllers are connected to one group, one controller
TION") must be set to sub.
4. Display change (1) Temperature display °C/°F setting ("TEMP MODE °C/°F") Setting the temperature unit (°C or °F) to display ("DISP MODE
SETTING") (2) Suction air temperature display setting ("ROOM TEMP DISP Setting the use or non-use of the display of indoor (suction) air tempera-
(2) Use of automatic mode setting ("SELECT AUTO MODE") Setting the use or non-use of "automatic" operation mode
(3) Temperature range limit setting ("LIMIT TEMP FUNCTION") Setting the temperature adjustable range (maximum, minimum)
(2) Use of clock setting ("CLOCK") Setting the use or non-use of clock function
(3) Timer function setting ("WEEKLY TIMER") Setting the timer type
(4) Contact number setting for error situation ("CALL.") Contact number display in case of error
Setting the telephone number
SELECT") ture
(3) Automatic cooling/heating display setting ("AUTO MODE Setting the use or non-use of the display of "Cooling" or "Heating" display
DISP C/H") during operation with automatic mode
12
Loading...
+ 25 hidden pages