Mitsubishi PC24EK, NH47NAD, NH569NXA, PCH36EK, PCH24EK User Manual

...
Mr.Slim
Ductless Air Conditioning And Heat Pump Product Guide
®
MMIITTSSUUBBIISSHHII EELLEECCTTRROONNIICCSS AAMMEERRIICCAA,, IINNCC..
HHVVAACC DDIIVVIISSIIOONN
33110000 AAVVAALLOONN RRIIDDGGEE PPLL.. SSTTEE.. 220000,,NNOORRCCRROOSSSS,, GGAA 3300007711 CCAALLLL:: 777700--661133--55884400 OORR 880000--443333--44882222 ((PPRREESSSS 33)),, FFAAXX:: 880000--888899--99990044
®
DUCTLESS AIR CONDITIONERS
Mr.Slim
Mr. Slim systems are unlike any other products in the HVAC category. Actually they’re a category in themselves because Mr. Slim is probably the most unique innovation in air comfort in two decades and one that has made us the worldwide leader in ductless.
We designed Mr. Slim air conditioners and heat pumps to solve cooling and heating problems that other systems have never addressed, specifically spot or zone cooling and heating especially in retrofit situations. These are voids in comfort that central air and room air simply can’t fill economically and attractively.
AND HEAT PUMPS
Where Mr. Slim Fits.
You’ll often encounter a hot or cold spot in existing buildings that already have large central systems. Is the answer to remodel and make way for more ductwork? Obviously that’s a small fortune. Should you opt for room air? It’s unsightly at best, expensive to run, and a real security hazard.
Now you’re beginning to see how Mr. Slim fits in. It’s the ideal supplemental system for cooling or heating those smaller zones with absolutely no ductwork, no remodeling, and few disruptions to business and traffic.
Our system is energy
efficient and whisper quiet.
Its remote control keeps all
operating functions and
data within a glance and
in easy reach. And it
neatly tucks away into
corners, blending in
with the room’s decor.
How Mr. Slim Works.
Basically Mr. Slim is two units: an indoor air
handler and an outdoor compressor unit.
The two connect via refrigerant lines through a three inch diameter opening in the wall or ceiling. In fact that’s the toughest part of installation: one hole.
You can locate the compact outdoor compressor unit anywhere up to 164 feet away from the air handler on select models: in many cases. Many models have a front service panel that clearly exposes all connections.
The indoor air handler is as easy to install as a ceiling fan. And both the indoor and outdoor units are microprocessor controlled. Simple remotes let you control all functions.
COMFORT MADE SIMPLE.
1
MITSUBISHI ELECTRONICS
HVAC DIVISION
CEILING SUSPENDED UNITS
®
Mr.Slim
MMeeddiiuumm--ttoo--llaarrggee ccaappaacciittyy ccoooolliinngg aanndd hheeaattiinngg
ffoorr llaarrggee aarreeaa ccoommmmeerrcciiaall aapppplliiccaattiioonnss
15
PPCC//PPCCHH
LARGE AREA COOLING AND HEATING MADE SIMPLE.
Intelligent
Highly advanced microprocessor technology is one reason why Mitsubishi leads the air comfort category. This ultrathin microprocessor remote controller with LCD display gives you a variety of functions and options to keep room comfort
• Computerized Dehumidification
• Operation Mode Setting (Heat, Auto, Cool/Dry)
• Temperature Setting (in units of two
degrees fahrenheit.)
• Self-Diagnostic Display
• Room Temperature Display
• Twenty-Four Hour On/Off Timer
• Fan Speed Indicator
• Auto/Swing Vane Operation
• Memory (for storing operation functions)
• Low Ambient Operation
• Whisper-Quiet Operation
• EMS Gateway Available To Management System
Via RS-232 Cable
Remote Controller
perfectly balanced. It lets you check Mr. Slim’s operating conditions with just a glance. In the rare case of a malfunction the self­diagnostic system even indicates specific problems for easy repair.
Mr. Slim heat pumps also feature automatic cooling/heating changeover for simple control and lower maintenance. You never have to readjust the unit.
Air Flow
These units offer a wide choice of air flow directions. In the heating mode the vanes automatically set the flow of warm air downward at an angle of seventy degrees cooling mode the vanes automatically set the flow of cool air outward (horizontally). But you can override the automatic setting to blend air flow. Four directions may be selected: one hundred percent downward, eighty percent downward and twenty percent horizontal, sixty percent downward, and forty percent horizontal or one hundred percent horizontal. Jumbo louvers automatically rotate right and left for uniform air distribution over your entire space.
fahrenheit
. In the
Outdoor Compressor Unit
Mr. Slim outdoor compressor units are extremely efficient and reliable and true space­savers.
These models can be installed up to 164 feet away from the indoor unit. They connect simply through a single three-to-four inch opening in the wall or ceiling. No ductwork or remodeling is necessary. As many as ten units can be installed in a row for major space savings.
Outdoor units are designed with a front­access service panel that provides easy access to all maintenance points.
These units operate in outdoor temperatures as low as zero
when the optional wind baffle is installed. So you can cool spaces such as computer rooms year round.
degrees fahrenheit
Redi-Charged System
Mr. Slim “P” series features the industry’s first redi-charged refrigerant system. There’s no longer any need to adjust the amount of refrigerant to match the piping length on-site unless lines exceed one hundred feet. You’ll see a major reduction in installation time and labor costs. Plus you can always count on Mr. Slim’s reliability from day one because it’s thoroughly charged and tested at the factory. You know it’s going to work.
Hot Start System
Mr. Slim heat pumps provide warmth right from the beginning. At the start of heating and during defrosting, a very low fan speed prevents the unit from blowing cold air into the room. And a microprocessor-controlled booster heater speeds the warming process.
16
Air Conditioners
Heat Pumps
PC24EK
PC24EK Cooling Capacity: 24,000 BTU/h SEER: 10.3 Dimensions: W:50-7/16”, D:26-13/16”, H:10-1/8”
PC30EK Cooling capacity: 31,000 BTU/h SEER: 10.4 Dimensions: W:50-7/16”, D:26-13/16”, H:10-1/8”
PC36EK Cooling capacity: 36,500 BTU/h SEER: 10.2 Dimensions: W:62-1/4”, D:26-13/16”, H:10-1/8”
PCH24EK
PCH24EK Cooling capacity: 24,000 BTU/h SEER: 10.3 Heating capacity: 27,000 BTU/h (33,500 w/ aux. booster heat) HSPF: 7.1 Dimensions: W:50-7/16”, D:26-13/16”, H:10-1/8”
PCH30EK Cooling capacity: 30,000 BTU/h SEER: 10.0 Heating capacity: 33,000 BTU/h (41,500 w/ aux. booster heat) HSPF: 7.1 Dimensions: W:50-7/16”, D:26-13/16”, H:10-1/8”
PCH36EK Cooling capacity: 35,400 BTU/h SEER: 10.4 Heating capacity: 38,000 BTU/h (47,600 w/ aux. booster heat) HSPF: 7.4 Dimensions: W:62-1/4”, D:26-13/16”, H:10-1/8”
PC42EK Cooling capacity: 42,500 BTU/h SEER 10.0 Dimensions: W:62-1/4”, D:26-13/16”, H:10-1/8”
Simplified Installation
Mr. Slim’s streamlined design makes indoor units adaptable to an almost infinite variety of room configurations. They’re simple to mount, and they require a minimum of wiring. Naturally they’re not only efficient but also whisper-quiet. You’ll hardly hear them running.
Refrigerant lines may be connected to the
outdoor unit from the front, rear, or side or
17
PCH42EK Cooling capacity: 42,000 BTU/h SEER: 10.0 Heating capacity: 43,000 BTU/h (52,600 w/ aux. booster heat) HSPF: 7.3 Dimensions: W:62-1/4”, D:26-13/16”, H:10-1/8”
beneath the base. This easy-access design lets you arrange and install a number of units in a small area.
Warranty
Mitsubishi is so confident of the reliability of Mr. Slim warranty on the compressor and a one year warranty on all other parts.
®
Systems that we offer a six year
ITEM MODEL
Cooling *1 BTU/h 24,000 31,000 36,500 42,500 24,000 30,000 35,400 42,000
Capacity
Power Consumption
EER SEER HSPF COP
INDOOR UNIT
External Finish Munsell 2.5Y 8/0.3 & N2 Power Supply V, phase, Hz 115, 1, 60 230, 1, 60 Max. Fuze Size (time delay) A Min. Ampacity Fan Motor F.L.A. Auxiliary Heater A(kW) Airflow Hi-Lo
Moisture Removal Pints/h Sound Pressure Level Hi-Lo dB(A) Cond. Drain Connection OD in.
Dimensions
Weight lbs.
OUTDOOR UNIT
External Finish Munsell 5Y 7/1 Sound Pressure Level dB(A) Power Supply V, phase, Hz 230, 1, 60 Max. Fuze Size (time delay) A Min. Ampacity Fan Motor F.L.A.
Compressor
Crankcase Heater A(W) .17(39) .17(39) .17(39) .17(39) .17(39) .17(39) .17(39) .17(39) Refrigerant Control Capillary Tube Defrost method Reverse Cycle
Dimensions
Weight lbs. REMOTE CONTROLLER With Indoor Unit Control Voltage
Heating *1 BTU/h — Heating *2 BTU/h — Cooling *1 kW 2.43 3.1 3.8 4.4 2.46 3.06 3.53 4.37 Heating *1 kW — Heating *2 kW
*1 9.9 10.0 9.6 9.7 9.8 9.8 10.0 9.6
Heating *1 3.3 3.1 3.3 3.1 Heating *2 2.6 2.4 2.1 2.3
3 3 3 3 12 15 15 17
Dry CFM 1,050-850 1,050-850 1,270-990 1,270-990 920-740 920-740 1,270-990 1,270-990 Wet CFM 900-730 900-730 1,100-860 1,100-860 830-670 830-670 1,100-860 1,100-860
W in. 50-7/16 50-7/16 62-1/4 62-1/4 50-7/16 50-7/16 62-1/4 62-1/4
D in. 26-13/16 26-13/16 26-13/16 26-13/16 26-13/16 26-13/16 26-13/16 26-13/16 H in. 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8
16 20 22 27 16 20 22 27
Model (Type) NH33NBD NH41NAD NH47NAD NH569NXA NH33NBD NH41NAD NH47NAD NH569NXA R.L.A.11.5 14 17.5 20 11.5 14 17.5 20 L.R.A.54 73 87 105 54 73 87 105
W in. 34-1/4 34-1/4 38-3/16 38-3/16 34-1/4 38-3/16 38-3/16 38-3/16
D in. 11-5/8 11-5/8 13-9/16 13-9/16 11-5/8 13-9/16 13-9/16 13-9/16
H in. 49-9/16 49-9/16 49-9/16 49-9/16 49-9/16 49-9/16 49-9/16 49-9/16
(by built- in transformer)
PC24EK PC30EK PC36EK PC42EK
10.3 10.4 10.2 10.0 10.3 10.0 10.4 10.0 — 7.1 7.1 7.4 7.3
PC24EK PC30EK PC36EK PC42EK PCH24EK PCH30EK PCH36EK PCH42EK
15 15 15 15 20 25 25 25
1.8 1.8 2.1 2.4 0.7 0.7 1.3 1.3 —
7.2 9.6 11.1 12.6 7.0 9.1 10.9 12.3
50-43 50-43 52-44 52-44 50-43 50-43 51-45 51-45
1 1 1 1 1 1 1 1
93 93 115 115 97 97 119 119
PU24EK PU30EK PU36EK PU42EK PU24EK PU30EK PU36EK PU42EK
55 55 55 56 55 55 55 53
20 30 30 40 20 30 30 40
0.65+0.65 0.65+0.65 0.75+0.75 0.8+0.8 0.65+0.65 0.75+0.75 0.75+0.75 0.8+0.8
207 208 220 260 202 245 246 268
Indoor unit-remote controller: DC 12V, Indoor unit-outdoor unit: DC 12V
PCH24EK PCH30EK PCH36EK PCH42EK
27,000(33,500) 33,000(41,500) 38,000(47,600) 43,000(52,600) 18,400(24,900) 18,000(26,500) 19,600(29,200) 24,800(34,400)
2.42(4.32) 3.13(5.63) 3.4(6.2) 4.3(7.1)
2.1(4.0) 2.6(5.1) 2.7(5.5) 3.2(6.1)
8.4(1.9) 10.8(2.5) 12(2.8) 12(2.8)
Figures in parentheses include auxiliary heat. * For 208 volt applications refer to
Technical And Service Manual
for ratings.
18
CEILING MOUNTED CASSETTES
®
Mr.Slim
MMeeddiiuumm--ttoo--llaarrggee ccaappaacciittyy ccoooolliinngg aanndd hheeaattiinngg
ffoorr llaarrggee aarreeaa ccoommmmeerrcciiaall aapppplliiccaattiioonnss..
19
PPLL//PPLLHH
Intelligent
Remote Controller
Highly advanced microprocessor technology is one reason why Mitsubishi leads the air comfort category . This ultra-thin microprocessor remote controller with LCD display gives you a variety of functions and options to keep room comfort perfectly balanced. It lets you check Mr .
Slim’s operating conditions with just a glance. In the rare case of a malfunction the self-diagnostic system even indicates specific problems for easy repair.
• Computerized Dehumidification
• Operation Mode Setting (Heat, Auto, Cool/Dry)
• Temperature Setting (in units of two
degrees fahrenheit.)
• Self-Diagnostic Display
• Room Temperature Display
• Twenty-Four Hour On/Off Timer
• Fan Speed Indicator
• Auto/Swing Vane Operation
• Memory (for storing operation functions)
• Low Ambient Operation
• Whisper-Quiet Operation
• EMS Gateway Available To Management System
Via RS-232 Cable
Outdoor Compressor Unit
Mr. Slim outdoor compressor units are extremely efficient and reliable and true space­savers.
These models can be installed up to 164 feet away from the indoor unit. They connect simply through a single three inch opening in the wall or ceiling. No ductwork or remodeling is necessary. As many as ten units can be installed in a row for major space savings.
Outdoor units are designed with a front­access service panel that provides easy access to all maintenance points.
These units operate in outdoor temperatures as low as zero degrees
fahrenheit. when the optional wind baffle is installed. You can, therefore, cool spaces such as computer rooms year round.
Mr. Slim heat pumps also feature automatic cooling/heating changeover for simple control and lower maintenance. You never have to readjust the unit.
Air Flow
These ceiling cassettes offer multi­directional air flow in a number of various patterns to direct heat or cool air where you need it most. You can use two, three, or four vents and even set the vents for a narrow or wide breeze, depending on whether you prefer a strong, directed stream of air or a gentle breeze over a wide area. Air outlet vanes inside the vents automatically swing up and down for uniform air distribution.
Redi-Charged System
Mr. Slim “P” Series features the industry’s first redi-charged refrigerant system. There is no need to adjust the amount of refrigerant to match the piping length on-site unless lines exceed 100 feet. You’ll see a major reduction in installation time and labor costs. Plus you can always count on Mr. Slim’s reliability from day one because they’re thoroughly charged and tested at the factory. You know it’s going to work.
Hot Start System
Mr. Slim heat pumps provide warmth right from the beginning. At the start of heating and after defrosting, a very low fan speed prevents the unit from blowing cold air into the room. And a microprocessor controlled booster heater speeds the warming process.
LARGE AREA COOLING AND HEATING MADE SIMPLE.
- WAY AIR FLOW
FOUR PATTERNS
- WAY AIR FLOW
SIX PATTERNS (Except PL/PLH30 • 36 • 42FK)
2
3
- WAY AIR FLOW
ONE PATTERN
4
20
Air Conditioners
PL12FK
PL12FK Cooling capacity: 12,300 BTU/h SEER: 10.4 Cassette Dimensions: W:32-1/4” D:32-1/4” H:10-1/8”
PL18FK Cooling capacity: 18,400 BTU/h SEER: 10.2 Cassette Dimensions: W:32-1/4” D:32-1/4” H:10-1/8”
PL24FK Cooling capacity: 23,600 BTU/h SEER: 10.0 Cassette Dimensions: W:32-1/4” D:32-1/4” H:10-1/8”
PL30FK
PL30FK Cooling capacity: 31,000 BTU/h SEER: 10.4 Cassette Dimensions: W: 52-3/4” D:32-1/4” H:10-1/8”
PL34FK Cooling capacity: 32,400 BTU/h SEER: 10.0 Cassette Dimensions: W:52-3/4” D:32-1/4” H:10-1/8”
PL42FK Cooling capacity: 42,500 BTU/h SEER: 10.0 Cassette Dimensions: W:52-3/4” D:32-1/4” H:10-1/8”
Heat Pumps
PLH18FK
PLH18FK Cooling capacity: 17,300 BTU/h SEER: 10.3 Heating capacity: 18,000 BTU/h (24,500 w/ aux. booster heat) HSPF: 7.0 Cassette Dimensions: W:32-1/4” D:32-1/4” H:10-1/8”
PLH24FK Cooling capacity: 23,100 BTU/h SEER 10.3 Heating capacity: 25,000 BTU/h (31,500 w/ aux. booster heat) HSPF: 7.1 Cassette Dimensions: W:32-1/4” D:32-1/4” H:10-1/8”
PLH30FK
PLH30FK Cooling capacity: 30,000 BTU/h SEER 10.0 Heating capacity: 33,000 BTU/h (41,200 w/ aux. booster heat) HSPF: 7.1 Cassette Dimensions: W:52-3/4” D:32-1/4” H:10-1/8”
PLH36FK Cooling capacity: 35,400 BTU/h SEER 10.4 Heating capacity: 38,000 BTU/h (47,600 w/ aux. booster heat) HSPF: 7.4 Cassette Dimensions: W:52-3/4” D:32-1/4” H:10-1/8”
PLH42FK Cooling capacity: 42,000 BTU/h SEER: 10.0 Heating capacity: 44,300 BTU/h (53,900 w/ aux. booster heat) HSPF: 7.3 Cassette Dimensions: W:52-3/4” D:32-1/4” H:10-1/8”
Slimmer Indoor Unit And Fresh Air Intake
The unit is specially designed for neat and tidy installation. With minimum on-site work, branch ducting and outside air ducting can be installed.
Branch Duct
12 Inch
10 Inch
Unit Height Drain Height Panel Height 1 Inch
Simplified Installation
Mr. Slim Ceiling Cassettes install as easily as track lighting and make an extremely neat, unobtrusive presentation. They require only a
21
minimum of wiring. Naturally they’re not only
efficient but whisper quiet, too. You’ll hardly hear them running.
These models also feature a drain water lift-up mechanism that saves space and makes drainage pipe connection surprisingly simple.
Refrigerant lines may be connected to the outdoor unit from the front, rear , or side or beneath the base. This easy-access design lets you arrange and install a number of units in a small area.
Warranty
Mitsubishi is so confident of the reliability of Mr. Slim warranty on the compressor and a one year warranty on all other parts.
®
Systems that we offer a six year
ITEM MODEL PL12FK PL18FK PL24FK PL30FK PL34FK PL42FK PLH18FK PLH24FK PLH30FK PLH36FK PLH42FK
Cooling *1 BTU/h
12,300 18,400 23,600 31,000 32,400 42,500 17,300 23,100 30,000 35,400 42,000
Capacity
Heating *1 BTU/h
18,000(24,500) 25,000(31,500) 33.000 (41,200) 38,000 (47,600) 44.300 (53,900)
Heating *2 BTU/h
11,500 (18,000) 16,000(22,500) 20,800(29,000) 19,600 (29,200) 28,300 (37,900)
Power
Cooling *1 kW
1.23 1.88 2.48 3.10 3.76 4.40 1.77 2.42 3.20 3.53 4.27
Consumption
Heating *1 kW
1.6 (3.5) 2.48 (4.38) 2.97 (5.37) 3.40 (6.2) 4.38 (7.18)
Heating *2 kW
1.4 (3.3) 2.0 (3.9) 2.6 (5.0) 2.70 (5.5) 3.4 (6.2)
EER
*1 10.0 9.8 9.5 10.0 9.6 9.7 9.8 9.5 9.4 10.0 9.8
SEER
10.4 10.2 10.0 10.4 10.0 10.0 10.3 10.3 10.0 10.4 10.0
HSPF
7.0 7.1 7.1 7.4 7.3
COP
Heating *1
3.3 3.0 3.3 3.3 3.0
Heating *2
2.4 2.3 2.3 2.1 2.4
INDOOR UNIT
PL12FK
PL18FK PL24FK PL30FK PL34FK
PL42FK
PLH18FK PLH24FK PLH30FK PLH36FK PLH42FK
External Finish Galvanized sheets with gray heat insulation Power Supply V, phase, Hz
115, 1, 60 230, 1, 60 Max. Fuze Size (time delay) A 15 15 15 15 15 15 20 20 25 25 25 Min. Ampacity
2.0 2.0 2.0 2.0 2.0 3.0 15 15 17 17 17
Fan Motor F.L.A.
0.75 0.85 1.1 1.0 + 1.0 1 .0 + 1 .0 1.2 + 1.2
0.55 0.6
0.5 + 0.5 0.5+0.5 0.6 + 0.6
Auxiliary Heater A(kW)
8.4 (1.9) 8.4 (1.9) 11.0 (2.4) 12.0 (2.8) 12.0 (2.8)
Airflow Hi-Lo Dry CFM 570-540 680-460 750-550
1,170-850 1,170-850 1,270-920
600-390 640-420 1,060-670 1,060-670 1,090-780
Wet CFM 420-400 650-440 660-480
1 ,090-790 1,090-790 1,200-870
540-350 580-380 950-600 950-600 980-700
Moisture Removal Pints/h
3.8 5.3 6.8 9.6 10.9 12.6 5.3 7.0 9.1 10.9 12.3
Sound Pressure Level Hi-Lo dB(A)
43-35 45-38 47-39 49-41 49-41 49-42 45-38 47-39 49-41 49-41 49-42
Cond. Drain Connection OD in.
1-1/4
Cassette
W
in.
32-1/4 32-1/4 32-1/4 52-3/4 52-3/4 52-3/4 32-1/4 32-1/4 52-3/4 52-3/4 52-3/4
Dimensions
D
in.
32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4
H
in.
10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8
Weight
60 64 64 99 99 101 66 66 104 104 104
External Finish
Marble White
Decorative
W in. 36-5/8 36-5/8 36-5/8 57-1/8 57-1/8 57-1/8 36-5/8 36-5/8 57-1/8 57-1/8 57-1/8
Indoor grille Dimensions
D in. 36-5/8 36-5/8 36-5/8 36-5/8 36-5/8 36-5/8 36-5/8 . 36-5/8 36-5/8 36-5/8 36-5/8 H in. 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8
Weight 22 22 22 35 35 35 22 22 35 35 35
OUTDOOR UNIT
PU12EK PU18EK PU24EK PU30EK PU36EK PU42EK PUH18EK PUH24EK PUH30EK PUH36EK PUH42EK
External Finish Munsell 5Y 7/1 Sound Pressure Level dB(A) 50 53 55 55 55 56 53 55 55 55 56 Power Supply V, phase, Hz
230,1, 60 Max. Fuze Size (time delay) A 15 20 20 30 30 40 20 20 30 30 40 Min. Ampacity
11 16 16 20 22 27 16 16 20 22 27
Fan Motor F.L.A.
0.65 0.75
0.65+0.65
0.65+0.65 0.75+0.75
0.8 + 0.8
0.75 0.65 + 0.65 0.75 + 0.75 0.75+0.75 0.8 + 0.8
Model (Type)
RH167NAB RH247NAB NH33NBD NH41NAD NH47NAD NH569NXA RH247NAB NH33NBD NH41NAD NH47NAD NH569NXA
Compressor
R.L.A. 8.9 12 11.5 14 17.5 20 12 11.5 14 17.5 20
L.R.A. 29 37 54 73 87 105 37 54 73 87 105
Crankcase Heater A(W)
0.12 (28) 0.12 (28)
0.17(39) 0.12 (28) 0.17(39) Refrigerant Control Capillary Tube Defrost method Reverse Cycle
W in. 34-1/4 34-1/4 34-1/4 34-1/4 38-3/16 38-3/16 34-1/4 34-1/4 38-3/16 38-3/16 38-3/16
Dimensions
D in. 11-5/8 11-5/8 11-5/8 11-5/8 13-9/16 13-9/16 11-5/8 11-5/8 13-9/16 13-9/16 13-9/16 H in. 25-9/16 33-1/2 49-9/16 49-9/16 49-9/16 49-9/16 33-1/2 49-9/16 49-9/16 49-9/16 49-9/16
Weight lbs.
105 154 207 208 220 260 131 202 245 246 268 REMOTE CONTROLLER With indoor unit Control Voltage (by built- in transformer)
Indoor unit-remote controller: DC 12V, Indoor unit-outdoor unit: DC 12V
REFRIGERANT PIPING SIZE
3/8, 5/8 1/2, 3/4 3/8, 5/8 1/2, 3/4 1/2, 7/8
Figures in parentheses include auxiliary booster heat. * For 208 volt applications refer to
Technical And Service Manual
for ratings.
22
General Specifications
*1. Rating conditions (cooling)
(heating)
_____
Indoor: 80˚F DB, 67˚F WB Outdoor: 95˚F DB, 75˚F WB
_____
Indoor: 70˚F DB, 60˚F WB Outdoor: 47˚F DB, 43˚F WB *2. Include auxiliary electric heater operations at 115V. (MSH09EW, MSH12EN, MSH15EN) *3. Rated voltage of compressor and fan motor is 115V. (MUM18EW) *4. Values are for each indoor unit.
*5. Depth of outdoor unit ( ) includes thickness of fan grille.
Operating Range
Notes: For MS/MSH, MF, MSM
MODEL
Cooling
Heating
Maximum Minimum Maximum Minimum
Indoor air intake temperature
95˚F DB, 71˚F WB 67˚F DB, 57˚F WB 80˚F DB, 67˚F WB 70˚F DB, 60˚F WB
Outdoor air intake temperature
115˚F DB
67˚F DB 75˚F DB, 65˚F WB 17˚F DB, 15˚F WB
Notes: For PK/PKH, PC/PCH, PL/PLH
* 1. Rating conditions (cooling)
(heating)
* 2. Rating conditions (heating)
_____
Indoor: 80˚F DB, 67˚F WB Outdoor: 95˚F DB, 75˚F WB
_____
Indoor: 70˚F DB, 60˚F WB Outdoor: 47˚F DB, 43˚F WB
_____
Indoor: 70˚F DB, 60˚F WB Outdoor: 17˚F DB, 15˚F WB
* 3. Heating capacity and power consumption in [ ] include auxiliary electric heater operation at 208/230V.
Operating Range
MODEL
Cooling
Heating
*5 With Wind Baffle installed.
Maximum Minimum Maximum Minimum
Indoor air intake temperature
95˚F DB, 71˚F WB 67˚F DB, 57˚F WB 80˚F DB, 67˚F WB 70˚F DB, 60˚F WB
Outdoor air intake temperature
115˚F DB
*5 0˚F DB 75˚F DB, 65˚F WB 17˚F DB, 15˚F WB
REFRIGERANT TUBING SIZE
MODEL
Max. Height
Difference (ft)
MS09EW, MSH09EW, MSM18EW MF12EN, MF15EN MSM30EN (MS09EWX2•MS15ENX1)
MS12EN, MS15EN, MSH12EN, MSH15EN PK18EK, PKH18EK, PL18FK, PLH18FK,
PK12EK, PL12FK PK24EK, PKH24EK, PC24EK, PCH24FK,
PL24FK, PK24EK PK30EK, PKH30EK, PL30FK, PLH30FK,
PC30EK, PCH30EK, PL36FK, PLH36FK, PC36EK, PCH36EK, PL42FK2, PC42EK
PLH42FK, PCH42EK
*For more details refer to
MS09EW MS15EN
Technical And Service Manual
MITSUBISHI ELECTRONICS AMERICA, INC.
HVAC DIVISION
3100 AVALON RIDGE PL. STE. 200, NORCROSS, GA30071 CALL: 770-613-5840 OR 800-433-4822 (PRESS 3) FAX: 800-889-9904
25
25
25
130
164
Refrigerant Tubing
Max. Tubing
Length (ft)
49
65
49
130
164
. All specifications are subject to change without notice.
Tubing (OD)/N
Liquid
1/4
3/8
1/2
Connection
Method
Gas
3/8 1/2
3/8 5/8
Flared
5/8
3/4 7/8
Form No. MIT-MRS-24-97
Loading...