Heat pumps are now a realistic option for any home, in any
climate. The MXZ H2i® family of Hyper-Heating INVERTERTM
residential systems offer year-round, high-efficiency heating
and cooling for a variety of rooms, including bedrooms,
basements, sunrooms and more. A variety of indoor units provide
zone comfort control while the INVERTER-driven compressor
and electric LEVs in the outdoor units provide closer control
and higher efficiency with minimal power usage.
19.1 - 17.0 SEER, 11.3 - 9.8 HSPF, INVERTER-driven compressor.
Quiet outdoor unit operation as low as 49 dB(A).
Hyper-heating performance down to minus 13 degrees F outdoor ambient.
100% heating capacity at 5 degrees F outdoor ambient.
Factory installed base heater
- Prevents ice build up in extreme environments.
- Active during defrost cycle.
Optional M-NET adapter
- Quickly integrate advance controllers.
ENERGY EFFICIENT AND ENVIRONMENTALLY FRIENDLY
M-Series systems utilize green technologies, and are much more ecient, so homeowners never have to sacrice comfort over concerns about high-energy costs.
INVERTER-driven technology results in substantial energy and
utility savings for homeowners.
Zone control for improved comfort and decreased energy usage.
All MXZ H2i Systems are ENERGY STAR® rated.
Local and state utility rebates and incentive
opportunities (Visit dsireusa.org for information on availability in your area).
2
Includes correction for defrost.
0
20
40
60
80
100
120
-13 -4 0 5 10 17 25 30 35 40 47
Outdoor Temperature Degrees FWB
MXZ-C-NAHZ
Standard Heat Pump
% Heating Capacity
100%
87%
76%
MXZ H2i HEATING CAPACITY
AT LOW TEMPERATURES*
HEAT, AND LOTS OF IT
6, 9, 12, 15
18, 24
24
24, 30, 36
30, 36
Hyper-heating Equipment
Mitsubishi Electric systems feature the most advanced technology for delivering exceptional heat pump performance.
H2i® TECHNOLOGY
HEATING even when it's minus 13 degrees F
outdoor ambient, producing up to 100% heating capacity at 5 degrees F.
YEAR-ROUND COMFORT in extreme
climates without the need for energy-consuming indoor supplemental heating devices.
HOT-START TECHNOLOGY provides
warmth from the start, reducing drafts.
MINIMAL MAINTENANCE thanks to easily
accessible lters, little or no ductwork to clean, and simple wiring between the indoor and outdoor units.
MULTI-ZONE
OUTDOOR UNIT
MXZ-2C20NAHZ
MXZ-3C24NAHZ
MXZ-3C30NAHZ
MXZ-4C36NAHZ 12, 18, 24, 30, 36 24, 30, 36
MXZ-5C42NAHZ 12, 18, 24, 30, 36 24, 30, 36
MXZ-8C48NAHZ 12, 18, 24, 30, 36 24, 30, 36
Branch Box
MSZ-FH MSZ-GE MFZ-KA MVZ SEZ-KD SLZ PCA PLA PEAD
9, 12, 15
18
COMPATIBLE NOT COMPATIBLE
6, 9, 12, 15, 18
9, 12
18
12
12, 18
12, 18, 24
INDOOR UNIT
9, 12, 15
18
18
12, 24
24
18, 24
12
24
3
MULTI-ZONE APPLICATIONS
New hyper-heating multi-zone units allow you to create an oasis of comfort throughout your entire home
in the rooms you use most, any time of the year.
Each room (zone) operates independently with it's
own wireless or wired remote control, so people in
different rooms can choose the temperature
that makes them most comfortable.
4
Indoor Units
A
B
B B B B
Branch box
MSZ-FH09, 12, 15NA
New sleek design offers many new features including new multi-functional wireless remote controller.
• Triple-action ltration including anti-allergen enzyme lter.
• Double-vane air delivery for enhanced circulation.
• i-see SensorTM 3D senses human heat signatures.
MFZ-KA09, 12, 18NA
Floor-mounted indoor units are perfect for difcult
areas that may be smaller or don't have usable wall space.
• Top and bottom discharge vanes.
• Wireless remote control with smart set feature.
• Front panel lter access for ease of cleaning.
MSZ-GE09, 12, 15, 18, 24NA
Slim, wall-mounted units provide individual room control in a variety of applications.
• Offers wide angle of airow, 150 degrees from left to right.
• Quiet operation as low as 19 dB(A).
• Provides cooling and heating in a wide range of capacities.
SEZ-KD09, 12, 15, 18NA
Horizontal-ducted indoor units provide comfort and
efciency while staying hidden in ceiling or beneath
the oor.
• Build-in condensate lift mechanism (up to 22").
• Static capability up to 0.20" WG.
• Optional lter box with MERV-8 lters.
BRANCH BOX CONNECTIONS
When Using One Branch Box
Flare Connection - Max. 5 indoor units
SLZ-KA09, 12, 15NA
Ceiling-recessed indoor units offer a wide airow pattern for better air distribution in a less obtrusive style.
• Ventilation air knockouts available.
Offers a 2, 3, or 4 way airow pattern.
• Built-in condensate lift mechanism (up to 20").
When Using Two Branch Boxes
- Max. 8 indoor units
A
2 branches pipe (joint) : optional parts
A
A
A
B B
Branch box
B B B B
B
Branch box #1
Branch box #2
B B B
5
MXZ H2i Outdoor Units I Heat Pump
Model Name
Non-Ducted/ Ducted
Heating at 47F* (Non-Ducted/ Ducted)
Heating at 17F* (Non-Ducted/ Ducted)
Heating at 5F* Maximum Capacity
Efciency
Rated Capacity
Cooling *
Capacity Range
Rated Total Input
Rated Capacity
Capacity Range Btu/h
Rated Total Input W
Rated Capacity Btu/h 13,700 / 13,700
Maximum Capacity Btu/h
Rated Total Input W 1,450 /
SEER (Non-Ducted/Ducted)
EER (Non-Ducted/Ducted)
HSPF (Non-Ducted/Ducted)
Power Supply V, Ph, Hz 208 / 230V,1-Phase, 60 Hz
Recommended
Electrical Requirements
/Breaker Size
Fuse
MCA
MXZ-2C20NAHZ MXZ-3C24NAHZ MXZ-3C30NAHZ MXZ-4C36NAHZ
Btu/h
Btu/h
W
Btu/h
Btu/h 22,000 25,000 28,600 45,000
A
A
18,000 / 20,000 22,000 / 23,600 28,400 / 27,400 36,000 / 36,000
6,000 - 20,000 6,000 - 23,600 6,000 - 28,400
1,334 / 1,819
22,000 / 22,000
7,400 - 25,500
1,612 / 1,748
22,000 / 22,000
17.0 / 15.0 19.0 / 15.5
13.5 / 11.0 13.5 / 10.0
9.8 / 9.5
1,588
40
29
1,630 / 2,360 2,272 / 2,661 2,570 / 3,180
25,000 / 24,600 28,600 / 27,6
40
30
7,200 - 36,000
2,096 / 2,187 3,340 / 4,250
18,000 / 16,500 34,000 / 36,000
28,600 / 27,600 45,000 / 45,000
1,991 / 1,993 3,500 / 4,590
18.0 / 16.0 19.1 / 15.8
12.5 / 10.3 14.0 / 11.3
7,200 - 30,600
1,725 / 1,871
14,000 / 14,000
25,000 / 24,600
1,622 / 1,635
10.0 / 9.0 11.0 / 9.8 11.3 / 10.1
00 45,000 / 45,000
40
30
6,000 - 36,000
7,200 - 45,000
50
42
Indoor - Outdoor S1-S2
Voltage
Compressor
Fan Motor (ECM)
Sound Pressure Level
External Dimensions (H x W x D)
Net Weight
External
Refrigerant Pipe Size O.D.
Max. Piping Length for Each Indoor Unit
Max. Refrigerant line Length
Max. Refrigerant Pipe Height Difference
Finish
Indoor - Outdoor S2-S3
Cooling
Heating
Liquid (High Pressure)
Gas (Low Pressure) A,B: 3/8 / 9.52
If IDU is Above ODU Ft / m
If IDU is Below ODU
V
V
FLA
dB(A)
In / mm
Lbs / kg
In / mm
Ft / m 164 / 50
Ft / m
DC INVERTER - driven Twin Rotary
1.9
54 54
58
41-9/32 x 37-13/32 x 13
187 / 85
82 / 25
49 / 15
49 / 15
1/4 / 6.35
DC ± 24
1.9
54
189 / 86
52-
11/16 x 41-11/32 x
AC 208 / 230
1.9
58 58 53
189 / 86
Munsell No. 3Y 7.8/11
A: 1/2 / 12.7; B,C: 3/8 / 9.52
230 / 70
82 / 25
49 / 15
9 / 15
4
0.4 + 0.4
49
13(+1)
276 / 125
3/8 / 9.52
5/8 / 15.88
492 / 150
262 / 80
164 / 50
131 / 40
Connection Method
Refrigerant
Specications are subject to change without notice.
6
Flared / Flared
R410A
Model Name MXZ-5C42NAHZ MXZ-8C48NAHZ
Cooling * Non-Ducted/ Ducted
Heating at 47F* (Non-Ducted/ Ducted)
Heating at 17F* (Non-Ducted/ Ducted)
Rated Capacity
Capacity Range
Rated Total Input
Rated Capacity
Capacity Range
Rated Total Input
Rated Capacity
Maximum Capacity
Rated Total Input
Heating at 5F* Maximum Capacity
SEER (Non-Ducted/Ducted) 19.0 / 15.0 18.9 / 14.7
Efciency
EER (Non-Ducted/Ducted) 13.4 / 10.8 12.0 / 9.5
HSPF (Non-Ducted/Ducted) 11.0 / 10.1 11.0 / 10.0
Power Supply Electrical Requirements
Recommended Fuse/Breaker Size
MCA
Indoor-Outdoor S1-S2
Voltage
Compressor
Hermetic
Fan Motor (ECM)
Sound Pressure Level
External Dimensions (H x W x D)
Net Weight
External Finish
Refrigerant Pipe Size O.D.
Lbs / kg
Max. Refrigerant line Length
Max. Piping Length for Each Indoor Unit
Max. Refrigerant Pipe Height
Difference
Connection Method
Indoor-Outdoor S2-S3
FLA 0.4 + 0.4
Cooling
Heating 54 54
In / mm 52-11/16 x 41-11/32 x 13(+1)
Liquid (High Pressure)
Gas (Low Pressure)
Ft / m
If IDU is Above ODU
If IDU is Below ODU
Btu/h
Btu/h
W
Btu/h
Btu/h
W
Btu/h
Btu/h
W
Btu/h
V, Ph, Hz 208 / 230V, 1-Phase, 60 Hz
A
A
V
V
dB(A)
In / mm
Ft / m
Ft / m
Refrigerant
42,000 / 42,000 48,000 / 48,000
6,000-42,000 6,000-48,000
3,130 / 3,890 4,000 / 5,050
48,000 / 48,000 54,000 / 54,000
7,200-42,000 7,200-54,000
3,430 / 4,350 4,220 / 4,990
35,800 / 36,600 40,000 / 43,000
48,000 / 48,000 54,000 / 54,000
,650 / 4,290 4,340 / 5,250
3
48,000 54,000
50 50
42 42
AC 208 / 230
DC ± 24
50 51
276 / 125 276 / 125
Munsell No. 3Y 7.8/11
3/8 / 9.52
5/8 / 15.88
492 / 150
262 / 80
164 / 50
131 / 40
Flared / Flared
R410A
Model Name PAC-MKA30BC PAC-MKA50BC
Connectible No. of Indoor Units
Power Supply
Power Input
Current
Phase, Cycle, Voltage 1-Phase, 60 Hz, 208 / 230V
W
A
Width In
Dimensions
Net Weight
Lbs 15 16
3 5
Galvanized Sheets External Finish
17-23/32
Depth In
Height In
11-1/32
6-11/16
3
0.05
Gas (In) 5/8
Refrigerant Pipe Dimensions
Outdoor Unit to Branch Box
Branch Box to Indoor Units
Liquid (In)
Gas (In)
Liquid (In)
3/8
A,B,C: 3/8 A,B,C,D: 3/8l E: 1/2
A,B,C: 1/4 A,B,C,D,E: 1/4
Specications are subject to change without notice.
7
H2I® TECHNOLOGY FROM MITSUBISHI ELECTRIC
IS BECOMING THE NEW NORMAL, PROVIDING EXCEPTIONAL YEAR-ROUND COMFORT EVEN IN EXTREME CLIMATES.
H2i P-Series, single-zone
H2i MXZ-Series, multi-zone
H2i MXZ-Series, multi-zone
MITSUBISHI ELECTRIC H2I® PRODUCTS PROVIDE:
• Superior heating performance.
- Simultaneous heating and cooling down to -4° F
outdoor ambient (R2-Series, two-pipe design).
- 100% heating capacity at between 0° F and 5° F outdoor ambient.
- Up to 85% heating capacity heating
performance down to -13° F outdoor ambient.
For more information, visit www.mehvac.com.
Mitsubishi Electric Cooling & Heating 1340 Satellite Boulevard
Suwanee, GA 30024, Phone: 800-433-4822 Fax: 800-658-1458
Mitsubishi Electric and the three diamond logo are registered trademarks of Mitsubishi Electric Corporation. See complete warranty for terms, conditions and limitations.
MXZH2iRO I Printed In The U.S.A
H2i CITY MULTI, VRF multi-zone
H2i M-Series, single-zone
• Most complete family of hyper-heating, cold climate products from single-zone (9KBtu/h) to
VRF multi-zone systems (up to 16 tons).
• Built-in base pan heater (Select models only).
• FH wall-mounted ductless units offer i-see
Sensor™ 3D.
Loading...