Revision B:
• MXZ-2B40VA- E1 has been added.
Please void OBB554 REVISED EDITION-A.
SPLIT-TYPE AIR CONDITIONERS
OUTDOOR UNIT
PARTS CATALOG
HFC |
No. OBB554 |
utilized |
REVISED EDITION-B |
R410A |
|
Models
MXZ-2B40VA - E1
MXZ-3B54VA - E1
MXZ-3B68VA - E1
MXZ-4B71VA - E1
MXZ-4B80VA - E1
MXZ-5B100VA - E1
CONTENTS
1. RoHS PARTS LIST············································ 2
2. OPTIONAL PARTS·········································· 14
SERVICE MANUAL (OBH554)
MXZ-4B80VA
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
Revision B:
• MXZ-2B40VA- E1 has been added.
1 RoHS PARTS LIST
MXZ-2B40VA
1-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
17 |
16 15 |
14 |
10 |
18
19
13
1
11 12
3 |
4 |
5 |
6 |
7 |
8 |
9 |
2 |
|
|
|
|
|
|
2
MXZ-2B40VA
1-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
Part numbers that are circled are not shown in the illustration.
|
RoHS |
|
|
|
|
Symbol |
|
No. |
Part No. |
Part Name |
in Wiring |
||||
|
|||||||
|
G |
|
|
|
|
Diagram |
|
1 |
E12 |
A89 232 |
CABINET |
|
|||
2 |
G |
E12 |
927 |
521 |
GRILLE |
|
|
3 |
G |
E12 |
927 |
501 |
PROPELLER |
|
|
4 |
G |
E12 |
F24 |
290 |
BASE |
|
|
5 |
G |
E12 |
F24 |
900 |
COMPRESSOR |
MC |
|
6 |
G |
E12 |
065 |
506 |
COMPRESSOR RUBBER SET |
|
|
7 |
G |
E12 |
927 |
661 |
STOP VALVE (GAS) |
|
|
8 |
G |
E12 |
927 |
662 |
STOP VALVE (LIQUID) |
|
|
9 |
G |
E12 |
A47 245 |
SERVICE PANEL |
|
||
10 |
G |
E12 |
A47 233 |
BACK PANEL |
|
||
11 |
G |
E12 |
735 |
640 |
EXPANSION VALVE |
|
|
12 |
G |
E12 |
F25 |
493 |
EXPANSION VALVE COIL |
LEV B |
|
13 |
G |
E12 |
927 |
961 |
4-WAY VALVE |
|
|
14 |
G |
E12 |
900 |
523 |
CONDENSER NET |
|
|
15 |
G |
E12 |
929 |
293 |
SEPARATOR |
|
|
16 |
G |
E12 |
929 |
515 |
MOTOR SUPPORT |
|
|
17 |
G |
E12 |
927 |
297 |
TOP PANEL |
|
|
18 |
G |
E12 |
F24 |
630 |
OUTDOOR HEAT EXCHANGER |
|
|
19 |
G |
E12 A47 301 |
OUTDOOR FAN MOTOR |
MF |
|||
20 |
G |
E12 |
339 |
936 |
CAPILLARY TUBE |
|
|
21 |
G |
E12 |
838 |
936 |
CAPILLARY TUBE |
|
|
22 |
G |
E12 |
735 |
640 |
EXPANSION VALVE |
|
|
23 |
G |
E12 |
F24 |
493 |
EXPANSION VALVE COIL |
LEV A |
Q'ty/unit |
|
|
|
|
MXZ- |
|
Remarks |
||
2B40VA- |
E1 |
|
|
|
1 |
|
|
|
|
1 |
|
|
|
|
1 |
|
|
|
|
1 |
|
KNB092FFDHC |
||
1 |
|
|||
3 |
|
3RUBBERS/SET |
||
2 |
|
9.52 |
|
|
2 |
|
6.35 |
|
|
1 |
|
|
|
|
1 |
|
ROOM B |
|
|
1 |
|
|
||
1 |
|
|
|
|
1 |
|
|
|
|
1 |
|
|
|
|
1 |
|
|
|
|
1 |
|
|
|
|
1 |
|
|
|
|
1 |
|
|
|
|
1 |
|
RC0J50- |
|
|
4 |
|
3.0 |
1.4 |
600 |
2 |
|
3.0 |
2.0 |
200 |
1 |
|
ROOM A |
|
|
1 |
|
|
|
|
3
MXZ-2B40VA
1-2. OUTDOOR UNIT ELECTRICAL PARTS
12 11 10
9
8
|
|
|
1 |
|
2 |
3 |
4 |
5 |
|
|
|
|
|
|
|
|
|
|
6 |
|
7 |
Part numbers that are circled are not shown in the illustration. |
|
|
|
|||||||
|
RoHS |
|
|
|
|
|
Symbol |
|
Q'ty/unit |
|
No. |
Part No. |
Part Name |
in Wiring |
MXZ- |
Remarks |
|||||
|
|
|
|
|
|
|
Diagram |
|
2B40VA- E1 |
|
1 |
G |
|
|
|
|
|
|
|
|
|
E12 |
838 |
337 |
REACTOR |
|
L64 |
|
1 |
10A 23mH |
||
2 |
G |
E12 |
F23 |
440 |
POWER P.C. BOARD |
|
|
|
1 |
|
3 |
G |
E12 |
F23 |
454 |
INTERFACE P.C. BOARD |
|
|
1 |
|
|
4 |
G |
E12 |
A47 |
490 |
R.V. COIL |
|
21S4 |
|
1 |
DEFROST, DISCHARGE |
5 |
G |
E12 |
A47 |
308 |
THERMISTOR SET |
|
RT61,62,68 |
1 |
||
|
OUTDOOR HEAT EXCHANGER |
|||||||||
6 |
G |
E12 |
A47 |
309 |
AMBIENT TEMPERATURE THERMISTOR |
RT65 |
|
1 |
|
|
7 |
G |
E12 |
A47 |
329 |
DISPLAY P.C. BOARD |
|
|
1 |
2A 25mH |
|
8 |
G |
E12 |
A47 |
337 |
REACTOR |
|
L65 |
|
1 |
|
9 |
G |
E12 |
F24 |
374 |
TERMINAL BLOCK |
|
TB1 |
|
1 |
Power supply |
10 G |
E12 |
935 |
374 |
TERMINAL BLOCK |
|
TB3 |
|
1 |
Indoor unit connecting |
|
11 G |
E12 |
935 |
374 |
TERMINAL BLOCK |
|
TB2 |
|
1 |
Indoor unit connecting |
|
12 |
G |
E12 |
F24 |
451 |
INVERTER P.C. BOARD |
|
|
1 |
Including heat sink and RT64 |
4
MXZ-2B40VA
1-3. DRAIN SOCKET
Outdoor unit 42 drain hole
1
Soft vinyl chloride hose of
25 mm inside diameter
|
RoHS |
|
|
Symbol |
Q'ty/unit |
|
No. |
Parts No. |
Parts Name |
in Wiring |
MXZ- |
Remarks |
|
|
|
|
Diagram |
2B40VA- E1 |
|
|
|
|
|
|
|
||
1 |
G |
E12 838 704 |
DRAIN SOCKET |
|
1 |
|
5