Revision B:
•
MXZ-2B40VA- E1 has
been added.
SPLIT-TYPE AIR CONDITIONERS
OUTDOOR UNIT
PARTS CATALOG
Models
MXZ-2B40VA -
MXZ-3B54VA -
MXZ-3B68VA -
E1
E1
E1
Please void OBB554
HFC
utilized
R410A
REVISED EDITION-B
REVISED EDITION-A.
No. OBB554
MXZ-4B71VA -
MXZ-4B80VA -
E1
E1
MXZ-5B100VA -
E1
CONTENTS
1. RoHS PARTS LIST ············································ 2
2. OPTIONAL PARTS ·········································· 14
SERVICE MANUAL (OBH554)
MXZ-4B80VA
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
Revision B:
•
MXZ-2B40VA- E1 has
been added.
1
RoHS PARTS LIST
MXZ-2B40VA
1-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
14
19
17
18
16
15
10
13
1
11
12
4
3
2
5
6
7
8
9
2
MXZ-2B40VA
1-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS
Part numbers that are circled are not shown in the illustration.
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Part No.
RoHS
G
E12 A89 232
G
E12 927 521
G
E12 927 501
G
E12 F24 290
G
E12 F24 900
G
E12 065 506
G
E12 927 661
G
E12 927 662
G
E12 A47 245
G
E12 A47 233
G
E12 735 640
G
E12 F25 493
G
E12 927 961
G
E12 900 523
G
E12 929 293
G
E12 929 515
G
E12 927 297
G
E12 F24 630
G
E12 A47 301
G
E12 339 936
G
E12 838 936
G
E12 735 640
G
E12 F24 493
Part Name
CABINET
GRILLE
PROPELLER
BASE
COMPRESSOR
COMPRESSOR RUBBER SET
STOP VALVE (GAS)
STOP VALVE (LIQUID)
SERVICE PANEL
BACK PANEL
EXPANSION VALVE
EXPANSION VALVE COIL
4-WAY VALVE
CONDENSER NET
SEPARATOR
MOTOR SUPPORT
TOP PANEL
OUTDOOR HEAT EXCHANGER
OUTDOOR FAN MOTOR
CAPILLARY TUBE
CAPILLARY TUBE
EXPANSION VALVE
EXPANSION VALVE COIL
Symbol
in Wiring
Diagram
MC
LEV B
MF
LEV A
Q'ty/unit
MXZ-
2B40VA-
1
1
1
1
1
3
2
2
1
1
1
1
1
1
1
1
1
1
1
4
2
1
1
E1
Remarks
KNB092FFDHC
3RUBBERS/SET
9.52
6.35
ROOM B
RC0J50-
3.0 1.4 600
3.0 2.0 200
ROOM A
3
MXZ-2B40VA
1-2. OUTDOOR UNIT ELECTRICAL PARTS
12
11
10
9
8
15
Part numbers that are circled are not shown in the illustration.
No.
1
2
3
4
5
6
7
8
9
10
11
12
Part No.
RoHS
G
E12 838 337
G
E12 F23 440
G
E12 F23 454
G
E12 A47 490
G
E12 A47 308
G
E12 A47 309
G
E12 A47 329
G
E12 A47 337
G
E12 F24 374
G
E12 935 374
G
E12 935 374
G
E12 F24 451
REACTOR
POWER P.C. BOARD
INTERFACE P.C. BOARD
R.V. COIL
THERMISTOR SET
AMBIENT TEMPERATURE THERMISTOR
DISPLAY P.C. BOARD
REACTOR
TERMINAL BLOCK
TERMINAL BLOCK
TERMINAL BLOCK
INVERTER P.C. BOARD
2
Part Name
3
4
Symbol
in Wiring
Diagram
L64
21S4
RT61,62,68
RT65
L65
TB1
TB3
TB2
6
Q'ty/unit
MXZ-
2B40VA-
E1
1
1
1
1
1
1
1
1
1
1
1
1
7
Remarks
10A 23mH
DEFROST, DISCHARGE
OUTDOOR HEAT EXCHANGER
2A 25mH
Power supply
Indoor unit connecting
Indoor unit connecting
Including heat sink and RT64
4
MXZ-2B40VA
1-3. DRAIN SOCKET
Outdoor unit 42 drain hole
1
Soft vinyl chloride hose of
25 mm inside diameter
No.
1
Parts No. Parts Name
RoHS
G
E12 838 704
DRAIN SOCKET
Symbol
in Wiring
Diagram
Q'ty/unit
MXZ-
2B40VA-
1
Remarks
E1
5