Mitsubishi Electric MSZ-WR09NA, MSZ-WR12NA User Manual

SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSZ-WR09NA MSZ-WR12NA
OPERATING INSTRUCTIONS
MANUAL DE INSTRUCCIONES
• Para utilizar esta unidad de forma correcta y segura, lea previamente es­tas instrucciones de funcionamiento.
NOTICE D’UTILISATION
• Pour avoir la certitude d’utiliser cet appareil correctement et en toute sécurité, veuillez lire cette notice d’instructions avant de mettre le climati­seur sous tension.
For user
Para los clientes
A l’attention des clients
English
Español
Français
● OPERATING INSTRUCTIONS ●
CONTENTS
SAFETY PRECAUTIONS 1
NAME OF EACH PART 3
PREPARATION BEFORE OPERATION 4
SELECTING OPERATION MODES 5
FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 6
ECONO COOL OPERATION 6
TIMER OPERATION (ON/OFF TIMER) 6
CLEANING 7
WHEN YOU THINK THAT TROUBLE HAS OCCURRED 8
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 9
INSTALLATION PLACE AND ELECTRICAL WORK 9
SPECIFICATIONS 9
SAFETY PRECAUTIONS
• Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these “Safety Precautions” before use.
• Since the cautionary items shown here are important for safety, be sure to observe them.
• After reading this manual, keep it together with the installation manual in a handy place for easy reference.
• Be sure to receive a guarantee card from your dealer and check that the purchased date and shop name, etc. are entered correctly.
Marks and their meanings
WARNING :
CAUTION :
Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability.
Incorrect handling could cause serious hazard depending on the conditions.
WARNING
Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to a single AC outlet.
• This may cause overheating, fi re, or electric shock.
Make sure the power plug is free of dirt and insert it securely into the outlet.
• A dirty plug may cause fi re or electric shock.
Do not bundle, pull, or modify the power cord, and do not apply heat or place heavy objects on it.
• This may cause fi re or electric shock.
Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation.
• This may create sparks, which can cause fi re.
• After the indoor unit is switched OFF with the remote controller, make sure to turn the breaker OFF or disconnect the power plug.
Do not expose your body directly to cool air for a prolonged length of time.
• This could be detrimental to your health.
The unit should not be installed, relocated, disassembled, altered, or repaired by the user.
• An improperly handled air conditioner may cause fi re, electric shock, injury, or water leakage, etc. Consult your dealer.
• If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order to avoid a hazard.
When installing, relocating, or servicing the unit, make sure that
no substance other than the specifi ed refrigerant (R410A) enters
the refrigerant circuit.
• Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury.
• The use of any refrigerant other than that specifi ed for the system will cause mechanical failure, system malfunction, or unit break­down. In the worst case, this could lead to a serious impediment to securing product safety.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your fi nger or stick, etc.
: Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do not insert your fi nger, a stick, or other objects into the air
inlet or outlet.
• This may cause injury, since the fan inside rotates at high speeds during operation.
In case of an abnormal condition (such as a burning smell),
stop the air conditioner and disconnect the power plug or turn the breaker OFF.
• A continued operation in the abnormal state may cause a malfunc­tion, fi re, or electric shock. In this case, consult your dealer.
When the air conditioner does not cool or heat, there is a pos­sibility of refrigerant leakage. In this case, consult your dealer. If a repair involves recharging the unit with refrigerant, ask the service technician for details.
• The refrigerant used in the air conditioner is safe. Normally, it does not leak. However, if refrigerant leaks and comes in contact with a heat source such as a fan heater, kerosene heater, or cooking stove, it will create a harmful gas.
The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer.
• Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage. Should detergent come in contact with electrical parts or the motor, it will result in a malfunction, smoke, or fi re.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
En-1
SAFETY PRECAUTIONS
CAUTION
Do not touch the air inlet or the aluminum fi ns of the indoor/
outdoor unit.
• This may cause injury.
Do not use insecticides or fl ammable sprays on the unit.
• This may cause a fi re or deformation of the unit.
Do not expose pets or houseplants to direct airfl ow.
• This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the indoor/outdoor unit.
• Water may drip down from the unit, which may cause damage or malfunction.
Do not leave the unit on a damaged installation stand.
• The unit may fall and cause injury.
Do not step on an unstable bench to operate or clean the unit.
• This may cause injury if you fall down.
Do not pull the power cord.
• This may cause a portion of the core wire to break, which may cause overheating or fi re.
Do not charge or disassemble the batteries, and do not throw
them into a fi re.
• This may cause the batteries to leak, or cause a fi re or explosion.
Do not operate the unit for more than 4 hours at high humidity (80% RH or more) and/or with windows or outside door left open.
• This may cause the water condensation in the air conditioner, which may drip down, wetting or damaging the furniture.
• The water condensation in the air conditioner may contribute to growth of fungi, such as mold.
Do not use the unit for special purposes, such as storing food, raising animals, growing plants, or preserving precision devices or art objects.
• This may cause deterioration of quality, or harm to animals and plants.
Do not expose combustion appliances to direct airfl ow.
• This may cause incomplete combustion.
Never put batteries in your mouth for any reason to avoid ac­cidental ingestion.
• Battery ingestion may cause choking and/or poisoning.
Before cleaning the unit, switch it OFF and disconnect the power plug or turn the breaker OFF.
• This may cause injury, since the fan inside rotates at high speeds during operation.
When the unit will be unused for a long time, disconnect the power plug or turn the breaker OFF.
• The unit may accumulate dirt, which may cause overheating or fi re.
Replace all batteries of the remote controller with new ones of the same type.
• Using an old battery together with a new one may cause overheating, leakage, or explosion.
If the battery fl uid comes in contact with your skin or clothes,
wash them thoroughly with clean water.
• If the battery fl uid comes in contact with your eyes, wash them thoroughly with clean water and immediately seek medical attention.
Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance.
• Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a pos­sibility of a lightning strike.
• The unit may be damaged if lightning strikes.
After the air conditioner is used for several seasons, perform inspection and maintenance in addition to normal cleaning.
• Dirt or dust in the unit may create an unpleasant odor, contribute to growth of fungi, such as mold, or clog the drain passage, and cause water to leak from the indoor unit. Consult your dealer for inspection and maintenance, which require specialized knowledge and skills.
Do not operate switches with wet hands.
• This may cause electric shock.
Do not clean the air conditioner with water or place an object that
contains water, such as a fl ower vase, on it.
• This may cause fi re or electric shock.
Do not step on or place any object on the outdoor unit.
• This may cause injury if you or the object falls down.
IMPORTANT
Dirty fi lters cause condensation in the air conditioner which will contribute
to the growth of fungi such as mold. It is therefore recommended to clean air
fi lters every 2 weeks.
For installation
WARNING
Consult your dealer for installing the air conditioner.
• It should not be installed by the user since installation requires spe­cialized knowledge and skills. An improperly installed air conditioner may cause water leakage, fi re, or electric shock.
Provide a dedicated power supply for the air conditioner.
• A non-dedicated power supply may cause overheating or fi re.
Do not install the unit where fl ammable gas could leak.
• If gas leaks and accumulates around the unit, it may cause an explosion.
Ground the unit correctly.
• Do not connect the ground wire to a gas pipe, water pipe, lightning rod, or a telephone ground wire. Improper grounding may cause electric shock.
CAUTION
Install a Ground Fault Interrupt (GFI) circuit breaker depending on the installation location of the air conditioner (such as highly humid areas).
• If the Ground Fault Interrupt (GFI) breaker is not installed, it may cause electric shock.
Ensure that the drain water is properly drained.
• If the drain passage is improper, water may drip down from the indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
En-2
● OPERATING INSTRUCTIONS ●
NAME OF EACH PART
Indoor unit Remote controller
Front panel
Air fi lter
Air cleaning fi lter (Anti-allergy Enzyme Filter, option)
Air inlet
Air outlet
Horizontal vane
Outdoor unit
Heat exchanger
Display section
Remote control receiving section
Operation indicator lamp Emergency
operation switch
Page 5
Air inlet (back and side)
Operation display section
OFF/ON (stop/operate) button
FAN speed control button
Page 6
Operation select button
Page 5
TIMER mode select button
Page 6
Only use the remote controller provided with the unit. Do not use other remote controllers. If two or more indoor units are installed in proximity to one another, an indoor unit that is not intended to be operated may respond to the remote controller.
Signal transmitting section Distance of signal : About 20 ft. (6 m)
Beep(s) is (are) heard from the indoor unit when the signal is received.
Temperature buttons
Page 4, 5
ECONO
button
COOL
Page 6
VANE control
Page 6
button
TIME set button
Page 6
RESET button
Page 4
Outdoor units may be different in appearance.
Refrigerant piping
Drainage hose
Air outlet
Drain outlet
En-3
PREPARATION BEFORE OPERATION
Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on.
Installing the remote controller batteries
Remove the back lid.
1.
Insert the negative
2.
pole of AAA alkaline
Install the back lid.
3.
• Make sure the polarity of the batteries is correct. Do not use manganese batteries and leaking batteries. The remote controller could
• malfunction.
• Do not use rechargeable batteries.
• Replace all batteries with new ones of the same type.
• Batteries can be used for approximately 1 year. However, batteries with expired shelf lives last shorter.
Press RESET.
4.
batteries fi rst.
• Press RESET gently using a thin instrument.
If the RESET button is not pressed, the remote controller may not operate correctly.
Changing temperature units (°F→°C)
Unit is preset with °F.
Press RESET while
1.
the temperature but­tons are pressed.
• Press RESET gently using a thin instrument.
• To change temperature unit from °C to °F, press RESET.
En-4
● OPERATING INSTRUCTIONS ●
SELECTING OPERATION MODES
COOL mode
Enjoy cool air at your desired temperature.
Note:
Do not operate COOL mode at very low outside temperatures (less than 14°F [-10°C]). Water condensed in the unit may drip and wet or damage furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly. Temperature cannot be set during DRY mode.
HEAT mode
Enjoy warm air at your desired temperature.
Emergency operation
1
2
Press
to start the operation.
Press to select operation mode. Each press changes mode in the following order:
(COOL)
(DRY)
(HEAT)
3
Press or to set the temperature. Each press raises or lowers the temperature by 1°F (1°C).
Press to stop the operation.
• The same setting is selected the next time by simply pressing .
Operation indicator lamp
The operation indicator lamp shows the operation state of the unit.
Indication Operation state Room temperature
The unit is operating to reach the set temperature
The room temperature is approaching the set temperature
About 4°F (2°C) or more away from set temperature
About 2 to 4°F (1 to 2°C) from set tem­perature
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation switch (E.O. SW) on the indoor unit.
Each time the E.O. SW is pressed, the operation changes in the following order:
Operation indicator lamp
Emergency COOL
Emergency HEAT
Set temperature : 75°F (24°C)
Stop
Fan speed : Medium Horizontal vane : Auto
Note:
The fi rst 30 minutes of operation is test run. Temperature control does not work, and fan speed is set to High.
Auto restart function
If a power failure occurs or the main power is turned off during operation, “Auto restart function” automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power. When timer is set, timer setting is cancelled and the unit starts operation when power is resumed.
If you do not want to use this function, please consult the service representative because the setting of the unit needs to be changed.
Lit Not lit
En-5
FAN SPEED AND
AIRFLOW DIRECTION ADJUSTMENT
ECONO COOL OPERATION
Press to select fan speed. Each press changes fan speed in the following order:
(AUTO) (Low) (Med.) (High) (Super High)
• Two short beeps are heard from the indoor unit when set to AUTO.
Press to select airfl ow direction. Each press changes airfl ow direction in the following order:
(AUTO) (1) (2) (3) (4) (5) (SWING)
• Two short beeps are heard from the indoor unit when set to AUTO.
Airflow direction
(AUTO) .......... The vane is set to the most efficient airflow direction. COOL/
DRY:horizontal position. HEAT:position (5).
(Manual).........For efficient air conditioning, select the upper position for COOL/
DRY, and the lower position for HEAT. If the position (4) or (5) is selected during COOL/DRY, the vane automatically moves to the upward position after 0.5 to 1 hour to prevent any condensation from dripping.
(Swing)...........The vane moves up and down intermittently.
To change the horizontal airfl ow direction.
Move the vertical vane manually before starting operation.
Press during COOL mode page 5 to start ECO­NO COOL operation.
The unit performs swing operation vertically in various cycle according to the temperature of the airflow. Set temperature is set 4°F (2°C) higher automatically.
Press again to cancel ECONO COOL operation.
• ECONO COOL operation also is cancelled when the VANE button is pressed.
What is “ECONO COOL”?
Swing air fl ow (change of air fl ow) makes you feel cooler than constant air fl ow. So, even though the set temperature is automatically set 4°F (2°C) higher, it is possible to perform cooling operation with keeping comfort. As a result, energy can be saved.
TIMER OPERATION (ON/OFF TIMER)
1
Press during operation to set the timer. Each press changes timer mode in the following order:
TIMER
(OFF TIMER) (ON TIMER)
2
Press to set the time of timer.
Each press increases or decreases the set time by 1 hour.
RELEASE
Press until “TIMER RELEASE” is selected to release timer.
Note:
• ON and OFF timers can not be used in combination.
• If power failure occurs while ON/OFF timer is set, see page 5 “Auto restart function”.
En-6
● OPERATING INSTRUCTIONS ●
CLEANING
Instructions:
• Switch off the power supply or turn off the breaker before cleaning.
• Be careful not to touch the metal parts with your hands.
• Do not use benzine, thinner, polishing powder, or insecticide.
Front panel
Hinge
Hole
1. Lift the front panel until a “click” is heard.
2. Hold the hinges and pull to remove as shown in the above illustration.
• Wipe with a soft dry cloth or rinse it with water.
• Do not soak it in water for more than two hours.
• Dry it well in shade before installing it.
3. Install the front panel by following the removal pro­cedure in reverse. Close the front panel securely and press the positions indicated by the arrows.
• Use only diluted mild detergents.
• Do not expose parts to direct sunlight, heat, or fi re to dry.
• Do not use water hotter than 120°F (50°C).
Air cleaning fi lter (Anti-allergy Enzyme Filter, option)
Back side of air fi lter
Every 3 months:
• Remove dirt by a vacuum cleaner.
When dirt cannot be removed by vacuum cleaning:
• Soak the fi lter and its frame in lukewarm water before rinsing it.
• After washing, dry it well in shade.
Every year:
• Replace it with a new air cleaning fi lter for best performance.
• Parts Number MAC-408FT-E
Pull to remove from the air fi lter
Air fi lter
Clean every 2 weeks
• Remove dirt by a vacuum cleaner, or rinse with water.
• Dry it well in shade before installing it.
Important
Clean the fi lters regularly for best performance and to reduce
power consumption.
Dirty fi lters cause condensation in the air conditioner which will
contribute to the growth of fungi such as mold. It is therefore rec­ommended to clean air fi lters every 2 weeks.
En-7
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
Even if these items are checked, when the unit does not recover from the trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
The unit cannot be operated.
The unit cannot be operated for about 3 minutes when restarted.
Mist is discharged from the air outlet of the indoor unit.
The swing operation of the HORIZONTAL VANE is suspended for a while, then restarted.
The airfl ow direction changes during operation. The direction of the horizontal vane cannot be adjusted with the remote controller.
The operation stops for about 10 minutes in the heating operation.
The unit starts operation by itself when the main power is turned on, but hasn’t received sign from the remote controller.
The indoor unit discolors over time.
Outdoor Unit
The fan of the outdoor unit does not rotate even though the compressor is running. Even if the fan starts to rotate, it stops soon.
Water leaks from the outdoor unit.
White smoke is discharged from the outdoor unit.
• Is the breaker turned on?
• Is the power supply plug connected?
• Is the ON timer set? Page 6
• This protects the unit according to instructions from the microprocessor. Please wait.
• The cool air from the unit rapidly cools moisture in the air inside the room, and it turns into mist.
• This is for the swing operation of the HORIZON­TAL VANE to be performed normally.
• When the unit is operated in COOL or DRY mode, if the operation continues with air blowing down for 0.5 to 1 hour, the direction of the airfl ow is automatically set to upward position to prevent water from condensing and dripping.
• In the heating operation, if the airfl ow temperature is too low or when defrosting is being done, the horizontal vane is automatically set to horizontal position.
• Outdoor unit is in defrost.
Since this is completed in max.10 minutes,
please wait. (When the outside temperature is too low and humidity is too high, frost is formed.)
• These models are equipped with an auto restart function. When the main power is turned off without stopping the unit with the remote controller and is turned on again, the unit starts operation automatically in the same mode as the one set with the remote control­ler just before the shutoff of the main power. Refer to “Auto restart function”. Page 5
• Although plastic turns yellow due to the infl uence of some factors such as ultraviolet light and temperature, this has no effect on the product functions.
• When the outside temperature is low during cool­ing operation, the fan operates intermittently to maintain suffi cient cooling capacity.
• During COOL and DRY operations, pipe or pipe connecting sections are cooled and this causes water to condense.
• In the heating operation, water condensed on the heat exchanger drips down.
• In the heating operation, the defrosting operation makes ice forming on the outdoor unit melt and drip down.
• In the heating operation, vapor generated by the defrosting operation looks like white smoke.
Symptom Explanation & Check points
Remote controller
The display on the remote controller does not appear or it is dim. The indoor unit does not respond to the remote control signal.
Does not cool or heat
The room cannot be cooled or heated suffi ciently.
The room cannot be cooled suffi ciently.
The room cannot be heated suffi ciently.
Air does not blow out soon in the heating operation.
Airfl ow
The air from the indoor unit smells strange.
Sound
Cracking sound is heard. • This sound is generated by the expansion/con-
“Burbling” sound is heard. • This sound is heard when the outside air is
Mechanical sound is heard from the indoor unit.
The sound of water fl owing is heard.
Hissing sound is sometimes heard.
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the upper operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An amplifi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
• Are the batteries exhausted? Page 4
• Is the polarity (+, -) of the batteries correct?
Page 4
• Are any buttons on the remote controller of other electric appliances being pressed?
• Is the temperature setting appropriate?
Page 5
• Is the fan setting appropriate? Please change fan speed to High or Super High. Page 6
• Are the fi lters clean? Page 7
• Is the fan or heat exchanger of the indoor unit clean?
• Are there any obstacles blocking the air inlet or outlet of the indoor or outdoor unit?
• Is a window or door open?
• It may take a certain time to reach the setting temperature or may not reach that depending on the size of the room, the ambient temperature, and the like.
• When a ventilation fan or a gas cooker is used in a room, the cooling load increases, resulting in an insuffi cient cooling effect.
• When the outside temperature is high, the cooling effect may not be suffi cient.
• When the outside temperature is low, the heating effect may not be suffi cient.
• Please wait as the unit is preparing to blow out warm air.
• Are the fi lters clean? Page 7
• Is the fan or heat exchanger of the indoor unit clean?
• The unit may suck in an odor adhering to the wall, carpet, furniture, cloth, etc. and blow it out with the air.
traction of the front panel, etc. due to change in temperature.
absorbed from the drain hose by turning on the range hood or the ventilation fan, making water fl owing in the drain hose to spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside wind is strong.
• This is the switching sound in turning on/off the fan or the compressor.
• This is the sound of refrigerant or condensed water fl owing in the unit.
• This is the sound when the fl ow of refrigerant inside the unit is changed.
En-8
● OPERATING INSTRUCTIONS ●
WHEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
1
Set to the highest temperature in manual COOL mode, and operate for 3 to 4 hours. Page 5
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to favorable conditions for growth of fungi, such as mold.
2
Press to stop the operation.
3
Turn off the breaker and/or disconnect the power supply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter. Page 7
2
Check that the air inlet and outlet of the indoor and outdoor units are not blocked.
3
Check that the ground wire is connected correctly.
4
Refer to the “PREPARATION BEFORE OPERATION”, and follow the instructions. Page 4
INSTALLATION PLACE AND
ELECTRICAL WORK
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as hot spring, sewage, waste water.
• Where oil is splashed or where the area is fi lled with oily smoke. (such as cooking areas and factories, in which the properties of plastic could be changed and damaged).
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit brothers the house next door.
• The mounting height of indoor unit 5.9 ft. to 7.5 ft. (1.8 m to 2.3 m) is recommended. If it is impossible, please consult your dealer.
The installation location of the outdoor unit should be at least 10 ft. (3 m) away from the antennas for TV sets, radios, etc. In areas where the reception is weak, provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception.
Inverter-type
3 ft. (1 m) or more
Radio
fl uorescent lamp
Keep a space to prevent the picture distortion or the noise.
TV
10 ft. (3 m) or more
4 in. (100 mm) or more
For the optimum effi ciency and to extend the life time of using, the outdoor unit should be installed in a well-ventilated dry place.
8 in. (200 mm) or more
wall, etc.
To prevent the ef­fects of a fl uorescent lamp, keep as far apart as possible.
3 ft. (1 m) or more
Cordless phone or Portable phone
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
SPECIFICATIONS
Guaranteed operating range
Indoor Outdoor
Cooling
Upper limit
Lower limit
Upper limit
Heating
Lower limit
Note:
1. The guaranteed operating range value is for 1:1 System Application.
2. If the outdoor temperature is below the lower limit of guaranteed operating range, the outdoor unit may stop operation until the outdoor temperature exceeds the lower limit.
En-9
90°F (32.2°C) DB 115°F (46.1°C) DB
73°F (22.8°C) WB
67°F (19.4°C) DB 32°F (0°C) DB
57°F (13.9°C) WB
80°F (26.7°C) DB 75°F (23.9°C) DB
65°F (18.3°C) WB
70°F (21.1°C) DB 5°F (-15°C) DB
4°F (-15.6°C) WB
DB: Dry Bulb WB: Wet Bulb