Never use any refrigerant other than that specified.
Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of.
Correct refrigerant is specified in the manuals and on the spec labels provided with our products.
We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by
failure to follow the instructions.
1
TECHNICAL CHANGES
MSZ-JP09WA
MSZ-JP12WA
1. New model
U1
-
U1
-
2
2
OBH820
PART NAMES AND FUNCTIONS
MSZ-JP09WA MSZ-JP12WA
Air ¿ lter
Air cleaning ¿ lter
(Anti-Allergy Enzyme
Filter, option)
Air inlet
Air outlet
Horizontal vane
Display section
Front panel
Heat exchanger
Remote controller
Remote control receiving section
ACCESSORIES
Installation plate1
Attachment screws for the installation plate
4 × 25 mm
Battery (AAA) for remote controller2
Wireless remote controller1
Felt tape (For left or left-rear piping)1
Remote controller holder1
Screws for the remote controller holder
3.5 × 16 mm (Black)
Operation indicator lamp
Emergency operation switch
5
2
3
3
OBH820
Indoor modelMSZ-JP09WAMSZ-JP12WA
Power supplyV, phase, Hz115, 1, 60
Max. fuse size (time delay)/ Disconnect switch
Min. circuit ampacityA1.4
Fan motorF.L.A1.07
Airfl ow
Super High - High - Med. Low
Moisture removalpt./h1.52.5
Sound level
Super High - High - Med. Low
Fan speed
Super High - High - Med. Low
Cond. drain connection O.D.in.5/8
Dimensions
WeightIb.22
External fi nishMunsell 1.0Y 9.2/0.2
Control voltage (by built-in transformer)12 - 24 V DC
NOTE: Test conditions are based on AHRI 210/240.
SPECIFICATION
COOL Dry
(Wet)
HEAT Dry CFM406 - 321 - 237 - 170
CoolingdB(A)43 - 37 - 30 - 2245 - 37 - 30 - 22
HeatingdB(A)43 - 37 - 30 - 22
Coolingrpm1,020 - 860 - 670 - 530
Heatingrpm1,040 - 860 - 670 - 530
W
D9-1/8
H11-5/8
A1520
CFM
in.
399 - 321 - 237 - 170
(364 - 286 - 201 - 134)
31-7/16
4
3-1. OPERATING RANGE
OBH820
(1) POWER SUPPLY
Rated voltage Guaranteed voltage (V)
Indoor unit
115 V
1 phase
60 Hz
(2) OPERATION
ModeCondition
Standard temperature806795—
Cooling
Heating
Maximum temperature9073115—
Minimum temperature675714—
Maximum humidity78%—
Standard temperature70604743
Maximum temperature80677565
Minimum temperature7060-4-5
3-2. OUTLET AIR SPEED AND COVERAGE
ModelModeFunction
HEATDry40620.629.5
MSZ-JP09WA
MSZ-JP12WA
COOL
HEATDry40620.629.5
COOL
Dry39920.229.0
Wet36418.426.5
Dry39920.229.0
Wet36418.426.5
Airfl ow
(CFM)
Min. 103
IndoorOutdoor
DBWBDBWB
Air speed
(ft./s.)
115
Max. 127
Intake air temperature (°F)
Coverage
(ft.)
● The air coverage is the figure up to the
position where the air speed is 1 ft./s.,
when air is blown out horizontally from
the unit properly at the High speed position.
The coverage should be used only as a
general guideline since it varies according to the size of the room and furniture
arranged inside the room.
Refrigerant flow in cooling
Refrigerant flow in heating
8
7
OBH820
SERVICE FUNCTIONS
MSZ-JP09WA MSZ-JP12WA
7-1. TIMER SHORT MODE
For service, the set time can be shortened by bridging of the timer short point on the indoor electronic control P.C. board.
The time will be shortened as follows. (Refer to 9-7.)
• The set time for the ON/OFF timer can be reduced to 1 second for each minute.
• After the breaker is turned on, the time for starting the compressor, which normally takes 3 minutes, can be reduced to
3 seconds. Restarting the compressor, which takes 3 minutes, cannot be reduced.
7-2. REMOTE CONTROLLER P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, the remote controller P.C. boards must be
modified according to the number of the indoor unit.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below:
J2
J1
NOTE: For modification, take out the
batteries and press the STOP/
OPERATE (OFF/ON) button 2
or 3 times at first.
After finish modification, put
back the batteries then press
the RESET button.
The remote controller P.C. board has the print “J1” and “J2”. Solder “J1” and “J2” according to the number of indoor unit as
shown in Table 1.
After modification, press the RESET button.
Table 1
1 unit operation2 units operation3 units operation4 units operation
No. 1 unitNo modifi cationSame as at leftSame as at leftSame as at left
No. 2 unit—Solder J1Same as at leftSame as at left
No. 3 unit——Solder J2Same as at left
No. 4 unit———Solder both J1 and J2
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the remote
controller for the indoor unit.
The indoor unit will only accept the signal from the remote controller that has been assigned to the indoor unit once they are
set.
The setting will be cancelled if the breaker is turned OFF, or the power supply is shut down.
Please conduct the above setting once again after the power has been restored.
9
7-3. AUTO RESTART FUNCTION
OBH820
When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed
are memorized by the indoor electronic control P.C. board. “AUTO RESTART FUNCTION” automatically starts operation in
the same mode just before the shut-off of the main power.
Operation
If the main power has been cut, the operation settings remain.After the power is restored, the unit restarts automatically according to the memory.
(However, it takes at least 3 minutes for the compressor to start running.)
How to disable “AUTO RESTART FUNCTION”
Turn OFF the main power of the unit.
Solder the Jumper wire JR07 on the indoor electronic control P.C. board. (Refer to 9-7.)
JR07
Indoor electronic
control P.C. board
CN111CN112
CN151
CN10A
NOTE:
•
The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the
remote controller.
• If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
• If the unit has been turned OFF with the remote controller before power failure, the auto restart function does not
work as the power button of the remote controller is OFF.
• To prevent the breaker from tripping OFF due to the rush of starting current, systematize other home appliance not to
turn ON at the same time.
• When some air conditioners are connected to the same supply system, if they are operated before power failure, the
starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting
current by adding to the system that allows the units to start one by one.
10