RoHS compliant products have <G> mark on the spec name plate.
PARTS CATALOG (OBB746)
Use the speci¿ ed refrigerant only
Never use any refrigerant other than that specified.
Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of.
Correct refrigerant is specified in the manuals and on the spec labels provided with our products.
We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by
failure to follow the instructions.
Revision A:
• MSZ-HM09/12/15/18NA-U1 have been added.
Revision B:
• 3-1. OPERATING RANGE has been modified.
1
TECHNICAL CHANGES
MSZ-HM24NA
1. New model
MSZ-HM09NA
MSZ-HM12NA
MSZ-HM15NA
MSZ-HM18NA
1. New model
U1
-
U1
-
U1
-
U1
-
U1
-
OBH746B
2
2
PART NAMES AND FUNCTIONS
MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA
Air ¿ lter
Air cleaning ¿ lter
(Anti-Allergy Enzyme
Filter, option)
Air inlet
Air outlet
Horizontal vane
Display section
Remote control receiving section
Front panel
Heat exchanger
Remote controller
ACCESSORIES
Installation plate1
Attachment screws for the installation plate
4 × 25 mm
Battery (AAA) for remote controller2
Wireless remote controller1
Felt tape (For left or left-rear piping)1
Operation indicator lamp
Emergency operation switch
5
OBH746B
3
MSZ-HM18NA MSZ-HM24NA
Front panel
Air ¿ lter
Air inlet
Air cleaning ¿ lter
(Anti-Allergy Enzyme
Filter, option)
ACCESSORIES
Installation plate1
Attachment screws for the installation
plate 4 × 25 mm
Wireless remote controller1
Felt tape (For left or left-rear piping)1
Battery (AAA) for remote controller2
Heat exchanger
Air outlet
Horizontal vane
Remote controller
Display section
Remote control receiving section
Operation indicator lamp
Emergency operation switch
5
OBH746B
4
3
Indoor modelMSZ-HM09NAMSZ-HM12NAMSZ-HM15NA
Power supplyV, phase, Hz208/230, 1, 60
Max. fuse size (time delay)/ Disconnect switch
Min. circuit ampacityA1.0
Fan motorF.L.A0.76
AirÀ ow
Super High - High - Med. Low
Moisture removalpt./h1.52.52.7
Sound level
Super High - High - Med. Low
Fan speed
Super High - High - Med. Low
Cond. drain connection O.D.in.5/8
Dimensions
WeightIb.22
External ¿ nishMunsell 1.0Y 9.2/0.2
Control voltage (by built-in transformer)12 - 24 VDC
Maximum temperature9073115—
Minimum temperature675714—
Maximum humidity78%—
Standard temperature70604743
Maximum temperature80677565
Minimum temperature7060-4(NA), 5(NA2)-5 (NA), 4 (NA2)
3-2. OUTLET AIR SPEED AND COVERAGE
ModelModeFunction
HEA TDry40620.629.5
MSZ-HM09NA
MSZ-HM12NA
MSZ-HM15NA
MSZ-HM18NA
MSZ-HM24NA
COOL
HEA TDry40620.629.5
COOL
HEA TDry46323.433.5
COOL
HEA TDry62528.542.6
COOL
HEA TDry70232.047.7
COOL
Dry32116.323.5
Wet28614.521.0
Dry32116.323.5
Wet28614.521.0
Dry42021.330.5
Wet38519.528.0
Dry62528.542.6
Wet56225.638.4
Dry70232.047.7
Wet63228.843.1
AirÀ ow
(CFM)
208230Max. 253
Intake air temperature (°F)
IndoorOutdoor
DBWBDBWB
Air speed
(ft./s.)
Coverage
(ft.)
Ɣ The air coverage is the figure up to the
position where the air speed is 1 ft./s.,
when air is blown out horizontally from
the unit properly at the High speed position.
The coverage should be used only as a
general guideline since it varies according to the size of the room and furniture
arranged inside the room.
For service, the set time can be shortened by bridging of the timer short point on the indoor electronic control P.C. board.
The time will be shortened as follows. (Refer to 9-7.)
• The set time for the ON/OFF timer can be reduced to 1 second for each minute.
• After the breaker is turned on, the time for starting the compressor, which normally takes 3 minutes, can be reduced to
3 seconds. Restarting the compressor, which takes 3 minutes, cannot be reduced.
7-2. REMOTE CONTROLLER P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, the remote controller P.C. boards must be
modified according to the number of the indoor unit.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below:
J2
J1
NOTE: For modification, take out the
batteries and press the STOP/
OPERATE (OFF/ON) button 2
or 3 times at first.
After finish modification, put
back the batteries then press
the RESET button.
The remote controller P.C. board has the print “J1” and “J2”. Solder “J1” and “J2” according to the number of indoor unit as
shown in Table 1.
After modification, press the RESET button.
Table 1
1 unit operation2 units operation3 units operation4 units operation
No. 1 unitNo modi¿ cationSame as at leftSame as at leftSame as at left
No. 2 unit—Solder J1Same as at leftSame as at left
No. 3 unit——Solder J2Same as at left
No. 4 unit———Solder both J1 and J2
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the remote
controller for the indoor unit.
The indoor unit will only accept the signal from the remote controller that has been assigned to the indoor unit once they are
set.
The setting will be cancelled if the breaker is turned OFF, or the power supply is shut down.
Please conduct the above setting once again after the power has been restored.
OBH746B
10
7-3. AUTO RESTART FUNCTION
When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed
are memorized by the indoor electronic control P.C. board. “AUTO RESTART FUNCTION” automatically starts operation in
the same mode just before the shut-off of the main power.
Operation
If the main power has been cut, the operation settings remain.After the power is restored, the unit restarts automatically according to the memory.
(However, it takes at least 3 minutes for the compressor to start running.)
How to disable “AUTO RESTART FUNCTION”
Turn OFF the main power of the unit.
Solder the Jumper wire JR07 on the indoor electronic control P.C. board. (HM09/12/15NA)
Cut the Jumper wire JR77 on the indoor electronic control P.C. board. (HM18/24NA) (Refer to 9-7.)
MSZ-HM09/12/15NA
Indoor electronic
control P.C. board
JR07
CN111CN112
CN151
CN10A
MSZ-HM18/24NA
Indoor electronic
control P.C. board
CN151
CN112
CN110
JR77
CN10ACN111
NOTE:
•
The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the
remote controller.
• If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
• If the unit has been turned OFF with the remote controller before power failure, the auto restart function does not
work as the power button of the remote controller is OFF.
• To prevent the breaker from tripping OFF due to the rush of starting current, systematize other home appliance not to
turn ON at the same time.
• When some air conditioners are connected to the same supply system, if they are operated before power failure, the
starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting
current by adding to the system that allows the units to start one by one.
NOTE: Last setting will be stored after the unit is turned OFF with the remote controller. Indoor unit receives the signal of the
remote controller with beeps.
Temperature buttons
ECONO COOL button
Vane control button
Time set buttons
RESET button
INDOOR UNIT DISPLAY SECTION
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
•The following indication applies regardless of shape of the indication.
IndicationOperation stateRoom temperature
The unit is operating to
reach the set temperature
About 4°F (2°C) or more
away from set temperature
Lighted
Blinking
Not lighted
The room temperature is
approaching the set temperature
About 2 to 4 °F (1° to 2°C)
from set temperature
8-1. COOL ( ) OPERATION
(1) Press STOP/OPERATE (OFF/ON) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TOO WARM or TOO COOL button) to select the desired temperature.
The setting range is 61 - 88°F (16 - 31°C).
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil
from frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works. The indoor fan
operates at the set speed and the compressor stops. This mode continues until the temperature of indoor heat exchanger
rises.