Mitsubishi Electric MR-C375C-W-A, MR-C375C-ST-A, MR-C375C-OB-A, MR-C375CL-W-A, MR-C375CL-ST-A Service Manual

...
Changes for the Better
Models
CONTENTS
A………….......Australia & New Zea land
1. SPECIFICATIONS....................................................
2. OUTLINES AND DIMENSIONS..................................
3. WIRING DIAGRAM....................................................
5. NAMES OF THE PARTS...........................................
6. TROUBLE SHOOTING..............................................
6.1 TROUBLE CRITERION OF MAIN PARTS.......
6.2 FUNCTION OF OPERATION PANEL..............
6.3 FLOW CHART OF SELF-CHECK....................
6.4 TEST POINT DIAGRAM OF MAIN CONTROL
BOARD........................................................
7. DISASSEMBLY INSTRUCTIONS...............................
8. PARTS LIST............................................................
1 3 5 7 9 11 11 14 15
18 19 24
MR-C375C-W-A MR-C375C-ST-A MR-C375C-OB-A MR-C375CL-W-A MR-C375CL-ST-A MR-C405C-W-A MR-C405C-ST-A MR-C405CL-W-A MR-C405CL-ST-A
2012
SERVICE MANUAL
NO.SM-RE-1206
MITSUBISHI ELECTRIC
HOME REFRIGERATORS
1-1 SPECIFICATIONS
MR-C375C-A, MR-C375CL-A
Power supply
Total capacity
L
Dimensions (HXWXD) mm. 1678 x 600 x 656
Cabinet
Acrylic resin coated steel
Food liner
ABS resin
Cabinet
Foamed cyclopenthane
Refrigerator door
Foamed cyclopenthane
Vegetable door
Foamed cyclopenthane
Freezer door
Foamed cyclopenthane
Cooling system
Freezer
Forced air convection
Refrigerator
3 way air flow
Evaporator
Fin and tube type
Condenser
Concealed type
Defrost system
Automatic (Defrost heater )
Drain
Automatic (drainage)
Temperature control system
Automatic control
Refrigerator room light
240V, 15W (E12)
Glass shelf (R)
1 pc.
Slide shelf
1 pc.
Slide chilled case
1 pc.
Water tank
1 pc.
Free pocket (L)
2 pcs.
Egg case
1 pc.
Bottle pocket 1 pc.
Vegetable case
1 pc.
Fruit case
1 pc.
Freezing case (UP)
1 pc.
Freezing case (LOW)
1 pc.
Ice box sheet
1 pc.
Ice spoon
1 pc.
Ice box
1 pc.
Kick plate
1 pc.
Weight
Unit
kg
69
Shipping
kg
75
1
SPECIFICATIONS
Insulation
Accessories
GROSS (AS) 375 (R : 197 V : 75 F : 103)
230-240V 50Hz
1
MR-C405C-A, MR-C405CL-A
Power supply
Total capacity L
Dimensions (HXWXD) mm. 1798 x 600 x 656
Cabinet Acrylic resin coated steel
Food liner ABS resin
Cabinet Foamed cyclopenthane
Refrigerator door Foamed cyclopenthane
Vegetable door Foamed cyclopenthane
Freezer door Foamed cyclopenthane
Cooling system Freezer Forced air convection
Refrigerator 3 way air flow
Evaporator Fin and tube type
Condenser Concealed type
Defrost system Automatic (Defrost heater )
Drain Automatic (drainage)
Temperature control system Automatic control
Refrigerator room light 240V, 15W (E12)
Glass shelf (R) 2 pcs.
Slide shelf 1 pc.
Slide chilled case 1 pc.
Water tank 1 pc.
Free pocket (L) 2 pcs.
Egg case 1 pc.
Free pocket (S) 1 pc.
Bottle pocket 1 pc.
Vegetable case 1 pc.
Fruit case 1 pc.
Freezing case (UP) 1 pc.
Freezing case (LOW) 1 pc.
Ice box sheet 1 pc.
Ice spoon 1 pc.
Ice box 1 pc.
Kick plate 1 pc.
Weight Unit kg 73
Shipping kg 80
230-240V 50Hz
Insulation
Accessories
GROSS (AS) 405 (R : 227 V : 75 F : 103)
2
1-2 ELECTRICAL PARTS SPECIFICATION
MR-C375C-A , MR-C375CL-A
Model
DHS66C10RAW
Power supply
220-240V, 50Hz
Compressor
Rated input
W
Starting current
A
Rated current
A
Winding resistance
(A.T.
20 oC
)
PTC RELAY
PTH7M330MD2
Model
5TM718MFBYY-53
Motor protector
Ambient temperature
oC
25
Time
Sec.
16 MAX
Current
A
4.2
Running capacitor
4µF
400
VAC
Capillary tube
mm.
1.8 X ∅ 0.6 X
2350
Dehydrant Molecular sieve
g
10
Refrigerant HFC. 134a
g
170
Defrosting timer
Control board
Defrost finish
oC
Thermister
14 + 1.
5
Thermal fuse
oC
73
Defrost heater
Not equipped
Model
FBA12J12VXC
Type
DC brushless
Rate Voltage
12 VDC
Input
W
4.2 (12 VDC)
Revolution
r.p.m
2300 (12 VDC)
Model
4715JL04WS16G51
Type
DC brushless
Rate Voltage
12 VDC
Input W1.44 (12 VDC)
Revolution
r.p.m
1450 (12 VDC)
Vegetable case heater
W
6
Water pipe heater
W
0.9
Drain pipe heater
W
6
Freezer
Refrigerator
Dial position
ON
OFF
OPEN
SHUT
LOW
o
C
-9.2
-15.7
7.0
5.1
MID
o
C
-14.0
-20.0
4.2
2.3
HI
o
C
-16.0
-21.9
1.6
-0.2
Refrigerator
372 Ω (240V,
155W)
113/113.5(220/240V 50Hz)
7.78/8.55(220/240V 50Hz)
0.70/0.64(220/240V 50Hz)
18.4 Ω(
Main
) / 18.
5 Ω(
Aux
)
Defrosting control
Deodorizing function of defrost heater
Thermistor R
Thermistor F
Fan motor
Heater
Machine Chamber
Temperature control
3
MR-C405C-A, MR-C405CL-A
Model
DHS66C10RAW
Power supply
220-240V, 50Hz
Compressor
Rated input
W
Starting current
A
Rated current
A
Winding resistance
(A.T.
20 oC
)
PTC RELAY
PTH7M330MD2
Model
5TM718MFBYY-53
Motor protector
Ambient temperature
oC
25
Time
Sec.
16 MAX
Current
A
4.2
Running capacitor
4µF
400
VAC
Capillary tube
mm.
1.8 X ∅ 0.6 X
2350
Dehydrant Molecular sieve
g
10
Refrigerant HFC. 134a
g
170
Defrosting timer
Control board
Defrost finish
oC
Thermister
14 + 1.
5
Thermal fuse
oC
73
Defrost heater
Not equipped
Model
FBA12J12VXC
Type
DC brushless
Rate Voltage
12 VDC
Input
W
4.2 (12 VDC)
Revolution
r.p.m
2300 (12 VDC)
Model
4715JL04WS16G51
Type
DC brushless
Rate Voltage
12 VDC
Input
W
1.44 (12 VDC)
Revolution
r.p.m
1450 (12 VDC)
Vegetable case heater
W
6
Water pipe heater
W
0.9
Drain pipe heater
W
6
Freezer
Refrigerator
Dial position
ON
OFF
OPEN
SHUT
LOW
o
C
-9.2
-15.7
7.4
5.4
MID
o
C
-14.0
-20.0
4.5
2.6
HI
o
C
-16.0
-21.9
1.9
0.1
Thermistor R
Thermistor F
Fan motor
Heater
Machine
Chamber
Temperature control
Refrigerator
372 Ω (240V,
155W)
113/113.5(220/240V 50Hz)
7.78/8.55(220/240V 50Hz)
0.70/0.64(220/240V 50Hz)
18.4 Ω(
Main
) / 18.
5 Ω(
Aux
)
Defrosting control
Deodorizing function of defrost heater
4
Unit : mm
MR-C375C-A, MR-C375CL-A
2
OUTLINES AND DIMENSIONS
PLUG CORD LENGTH
REQUIRED SPACE FOR INSTALLATION
100
1678
666
50
600
5
124
381
5
Unit : mm
MR-C405C-A, MR-C405CL-A
PLUG CORD LENGTH
REQUIRED SPACE FOR INSTALLATION
100
1798
666
50
20
600
20
5
1248
381
6
(SKELETON WIRING DIAGRAM)
MR-C375C-A, MR-C375CL-A
MR-C405C-A, MR-C405CL-A
3
WIRING DIAGRAM
7
(ACTUAL WIRING DIAGRAM)
MR-C375C-A, MR-C375CL-A
MR-C405C-A, MR-C405CL-A
Remark
GY=GRAY
BK=BLACK
BR=BROWN
W = WHITE OR = ORANGE
R = RED Y = YELLOW
SB = SKY BLUE YG = YELLOW/GREEN
P = PINK LG = LIGHT GREEN
LB = LIGHT BROWN BY = BRIGHT YELLOW
V = VIOLET BU = BLUE
8
MR-C375C-A, MR-C375CL-A
MR-C405C-A, MR-C405CL-A
4
REFRIGERANT CIRCUIT
Muffler
Evaporator
Capillary tube
Suction pipe
Dryer
Cabinet pipe
Charge pipe (High pressure side)
Charge pipe (Low pressure side)
Compressor
9
MR-C375C-A MR-C375CL-A MR-C405C-A MR-C405CL-A
5
NAMES OF PARTS
10
6.1 TROUBLE CRITERION OF MAIN PARTS
MR-C375CC-A
MR-C375CL-A
MR-C405C-A
MR-C405CL-A
Compressor
Measure the resistance with a tester.
(Ambient temperature:Room temperature 15oC ~ 25oC)
Measure the resistance with a tester.
Open
Close
Opened (∞ Ω )
PTC Relay
PTH7M330MD2
Measure the resistance with a tester.
(Ambient temperature:Room temperature 15oC ~ 25oC)
Normal
As PTC Relay has been heated while refrigerator is running be sure to measure the resistance after the thermistor has got cool enough.
33 (Approx.)
Abnormal(faulty)
Opened (∞ Ω ) or Short (0Ω)
Rated input W
113/113.5(220/240V 50Hz)
Short (0Ω )
18.5 Ω (Approx.)
Normal
Main wiring
A
Starting current
chamber at the rear side of
0.70/0.64(220/240V 50Hz)
A
7.78./8.55(220/240V 50Hz)
Rated current
Measure the resistance with a tester.(Ambient temperature:Room temperature 15oC ~ 25oC)
69 +
9o C
Abnormal
(faulty)
5TM718MFBYY-53
Opened
(∞ Ω )
or
Short (0Ω)
120 + 5o C
Connected
Point
Normal
18.4 (Approx.)
Auxilliary wiring
Run capacitor
4
µF
Rated input
Motor
protector
400VAC
Abnormal(faulty)
Model
the frame
the frame
In the control panel of the rear side at compressor room
Compressor in the machine chamber at the rear side of the frame
Model
Normal
Abnormal(faulty)
Less than 1
rear side of
chamber at the
the machine
Compressor in
6
Components / Part Name
TROUBLE SHOOTING
Model
Parts
Mounted
Position
Check Method and Criterion
DHS66C10RAW
Compressor in the machine
Auxilialy
wiring
Main
wiring
6
356
3
1
3
Therminal check point
11
Measure the resistance with a tester.(Ambient temperature:Room temperature 15oC
~ 25oC)
Measure the resistance with a tester.(Ambient temperature:Room temperature 15oC ~ 25oC)
Measure the resistance with a tester.(Ambient temperature:Room temperature 15oC ~ 25oC)
Normal
Abnormal (faulty)
Me
asure the resistance with a tester.(Ambient temperature:Room temperature 15oC ~ 25oC)
In the fan grille of the refrigerator compartment.
Normal
Between 3 - 1 (GND and Vcc): About 25k
In the machine chamber at the rear side of the frame.
4715JL04WS16G51
Model
Type
DC brushless
Normal
415
(Approx.)
Type DC brushless
Under the water tank holder in refrigerator compartment.
Open (∞ Ω )
or short
circuit (0)
Abnormal
(faulty)
Winding (Blue-White, Red-Yellow)
Water pump motor (DC 5V)
16 (Approx.)
Open (∞Ω) or
short circuit (0Ω)
Motor damper for refrigerator compartment/ slide compartment
In the fan grille of the refrigerator compartment.
Refrigerator fan motor
FBA12J12VXCModel
Machine chamber fan motor
Normal
Abnormal (faulty)
Between 3 - 1 (GND and Vcc): About 25k
Between 3-1 : open( ∞ Ω )
or
between 2-1 : short ( 0 )
Abnormal (faulty)
Between 3-1 : open( ∞ Ω )
or
between 2-1 : short ( 0 )
Check Method and Criterion
Parts Mounted Position
Components/
Part Name
12
Measure the resistance with a tester.(Ambient temperature:Room temperature 15oC ~ 25oC)
Measure the resistance with a tester.
(Ambient temperature:Room temperature 15oC ~ 25oC)
Measure the resistance with a tester according to the following graph. (Thermistor resistance values against temperature)
Resistance measured under the ambient temperature from -50oC to +50 oC
1. 200 to 500k ............normal
2. Out of the above range ............abnormal
(kΩ)
Thermistor Check Procedure
Thermistor resistance will vary with the change of temperature. Take the temperature around the thermistor, and then measure thermistor resistance using a
tester.
The relation between resistance
and temperature is as shown on the left side.
Trouble shooting with self-check
(1) If the self - check indicates the abnormality of thermistor right after the power is turned on, measure the resistance of the thermistor.
If the circuit of thermistor is short , check the element of the thermistor and the contact of the connector. (2) When the self - check indicates the abnormality of thermistor a few seconds after the power is turned on , check the contact of the connector.
Rated input 155 W
operation method
Power ON after defrosting
(14 + 1.5oC or more)
Thermistor
Opened ( ∞ Ω )
Defrost Heater
(Outside air thermistor) In the
buzzer board (check board)
Check Method and Criterion
Parts Mounted
Position
Components/
Part Name
(Defrost thermistor)
Evaporator
(Freezer compartment thermistor and Ice making tray thermistor) In Ice
maker of freezer compartment
Abnormal (faulty)
(Refrigerator compartment thermistor) In the
control panel of refrigerator compartment
372 (Approx.)
Normal
Water pipe heater
Normal
The heater is turned on when the temperature of tray for automatic ice making tray is about 10 oC or less
Operation method
In the drip tray under the evaporator of the freezer compartment
Abnormal (faulty)
1.3 k (Approx.) Open (∞ Ω )
At the left bottom of vegetable compartment
-20
20 30
-10
0
10
30
20
15
10
5
0
25
35
Thermistor resistance valves against temperature
Temperature
Black
Black
Outside air thermistor
Refrigerator compartment, Freezer compartment, ,Defrosting, Ice making
Inner thermistor
13
6.2 FUNCTION OF OPERATION PANEL
(1) Normal operation
(2) Ice making test / Self-check
2.1
Setting
Press the
switch for 5 seconds
2.2 Operation and display
During automatic ice making test,ice making stop LED blink.
When somthing is faulty
,
the trouble is indicated with blinking number of ice making stop LED
.(
See page
13,14
)
Self-check finishes automatically
.
LED trouble display is also automatically released
10
minutes later
.
However
,
the abnormal part has not been repair yet.
14
6.3 FLOW CHART OF SELF-CHECK
(1) Trouble shooting with self-check
This refrigerator has self-check feature to clarify and indicate where & what the trouble is. It can be checked that there is something wrong with electronic circuit and electric parts.
Remark
(2) Timing of self-check
Defrost heater and related parts :
Self-check is conducted after defrosting.(Make sure to confirm the display before unplugging because it is automatically reset once the power cord is pulled out.)
Ice maker and related parts :
To check the ice- making and then, check the blink amount of LED see the reference as (3)
Fan motor and related parts :
To check the blink amount of LED see the reference as (3)
Thermistor and related parts :
Self-check is continuously working.
Caution: The self-check will automatic start to begin power supply. But in the portion of the abnormality show the detail as (3) .
And the caution checking couldn't be summarized, please use self-check means by using operation panel.
Self-check
Press Ice making stop button
Was trouble
displayed?
Locate the trouble according to
LED indication.(See page
Disconnect power plug
Repair/replace defective part(s)
according to LED indication
Connect power plug
Press Ice making stop button
Self-check ,Ice making stop LED blink during the operational test of automatic ice maker.
Check the parts whose Abnormalities cannot be detected by self­check.(Remark.1)
Is error no
longer
displayed?
Self-check is finished.
Slide room
Refrigerator room
Ice making
stop LED
Refrigerator
Freezer
Ice maker off
No
No
Yes
Yes
Wait 10 minutes before
inserting the cord once it's unplugged.(If the cord is plugged in within 10 minutes,trouble may be display.)
During the ice making test mode,watch the operation of ice maker gear box and water pump in refrigerator.
Is trouble no longer
displayed?
No
1.) Self-check cannot detect abnormalities of the following parts. See page 11~13 for trouble criterion of main parts.
- Freezer & refrigerator door sw NG
- Thermo heater NG ( Water pipe / Vegetable case heater etc.)
- Motor damper NG
- Water pump motor NG
2.) If the abnormality is found when power is turned on, compressor and fan motor will be suspended for 20 minutes.
15
(3) LED trouble display and the check point
(3.1) LED trouble display : follow the procedure of "self check method and its operation" at page 11. Trouble is indicated by the blinking number
of ice making stop LED.
When several troubles occur, smaller blinking number of LEDs has to be indicated first.
(3.2) Check point and treatment
Normal
1.
Normally display and the Auto ice-maker
system display.
*
If non-power supply, it'll show as same
the effect.
Auto ice maker NG
1.
The connector lead wire of Auto ice maker
1.
Check all points of the Auto ice maker
is not orderly.
connector lead wire. May be un-lock
and struck insert.
2.
2.
3.
3.
PCB plate ( Ref Con assy) NG
Thermistor(I) NG
1.
The connector thermistor (I) lead wire
1.
Check all points of the thermistor (I)
isn't orderly.
connector lead wire, may be unlock
and struck insert.
2.
Thermistor (I) NG (break or short)
2.
If the resistance of thermistor (I) is NG,
should be changed the thermistor and
re-check the resistance.
3.
PCB plate (Ref Con assay) NG
3.
If the resistance is OK,should be changed
PCB plate (Ref Con assy and re-check
the resistance).
Thermistor (F) NG
1.
The connector thermistor (F) lead wire
1.
Check all points of the thermistor (F)
isn't orderly.
connector lead wire, may be unlock
and struck insert.
2.
Thermistor (F) NG (break or short)
2.
If the resistance of thermistor (F) is
NG,should be changed the thermistor and
re-check the resistance.
3.
PCB plate (Ref Con assy) NG
3.
If the resistance is OK,should be changed
PCB plate (Ref Con assy and re-check
the resistance.
Thermistor (DEF) NG
1.
The connector DEF. thermistor lead wire
1.
Check all points of the thermistor
isn't orderly.
(DEF) connector lead wires, may be
unlock and struck insert.
2.
Thermistor (DEF) NG (break or short)
2.
If the resistance of thermistor (DEF) is
NG,should be changed the thermistor and
re-check the resistance.
3.
PCB plate (Ref Con assy) NG
3.
If the resistance is OK,should be changed
PCB plate (Ref Con assy and re-check
the resistance.
Defrost heater NG
1.
1.
2.
Defrost heater break or
2.
Thermal fuse break.
and thermal fuse.
3.
PCB plate (Ref Con assy) break.
3.
If the resistance is OK,should be changed
PCB plate (Ref Con assy and re-check
the resistance.
isn't orderly.
maker.
Replace and re-check the PCB plate
and non-display)
connector lead wire, may be un-lock
Blink
Blink
Light
Light
Light
1 Blink
No Light
Display function of LED
Off
NO
Function Explanation
Light
No Light
Detecting method and corrective NG points
2 Blinks
Check the resistance of the defrost heater
and struck insert.
3 Blinks
Light
No Light
No Light
No Light
0.1 second
0.3 seconds
No Light
Replace and re-check the Auto ice
( Ref Con assy)
Auto ice maker (Motor's not rotate
The Defrost heater connector lead wire
Check all points of the defrost heater
Light
0.1 sec
5 sec
1
1
5 sec
1 2 1 2
5 sec
1 2 13
1 Cycle
0.1 sec
0.3 sec 0.3 sec
0.3 sec
1 Cycle
0.3 sec
1 Cycle
0.3 sec
Slide room
Refrigerator room
Ice making
stop LED
Refrigerator
Freezer
Ice maker off
16
Thermistor (R) NG
1.
The Thermistor (R) connector lead wire
1.
Check all points of Thermistor (R) connector
isn't orderly.
lead wire, may be unlock and struck insert.
2.
Thermistor (R) NG (break or short)
2.
If the resistance of Thermistor (R) is NG,
should be replaced the Thermistor (R) and
re-check the resistance.
3.
PCB plate (Ref Con assy) NG
3.
If the resistance is OK., should be replaced
PCB plate (Ref Con assy) and re-check the
resistance.
Thermistor (A.T.) NG
1.
The Thermistor (A.T.) connector lead
1.
Check all points of the thermistor (A.T.)
wire isn't orderly.
connector lead wire, may be unlock and
struck insert.
2.
Thermistor (A.T.) NG (break or short)
2.
If the resistance of Thermistor (A.T) is NG,
3.
PCB plate (Ref Con assy) NG
should be replaced the Thermistor (R)
and re-check the resistance.
3.
If the resistance is OK., should be replaced
PCB plate (Ref Con assy) and re-check the
resistance.
1.
DC motor is orderly connected.
1.
Check all points of DC motor connector
lead wire, may be unlock and struck insert.
2.
DC motor NG (Motor un-rotate and
2.
non-display)
re-check display.
3.
PCB plate (Ref Con assy) NG
3.
If the resistance is OK., should be replaced
PCB plate (Ref Con assy) and re-check the
resistance.
1.
DC fan motor is orderly connected.
1.
Check all points of DC Fan motor connector
lead wire, may be unlock and struck insert.
2.
DC fan motor NG (Motor un-rotated,
2.
Replace DC fan motor (Outer motor assy)
and non-display.)
and check display.
3.
PCB plate (Ref Con assy) NG
3.
If the resistance is OK., should be replaced
PCB plate (Ref Con assy) and re-check the
resistance.
PCB plate (Ref Con assy) NG
1.
PCB program (Ref Con assy) is NG
1.
Replace a new PCB plate (Ref Con assy)
Refrigerant circuit is NG.
1.
Pipe cracked (Welding joint)
1.
Check and corrective to each problem.
2.
Gas leak
3.
Compressor NG
Remark :
1.) For the refrigerator is NG more than one case, will show as the first symptoms before, such as Thermistor (F) NG (1 blink in 0.3 seconds) and
Thermistor (R) NG (4 blinks in 0.3 seconds). LED will blink 1 blink in 0.3 seconds until Thermistor (F) was corrected. Then change to 4 blinks in 0.3 seconds
and LED won't blink when Thermistor (R) was corrected.
2.) Ice making stop LED blink during the operational test for ice maker.
3.) Compressor won't work if the fridge have problem and LED blink.
4.) Characteristic value may be changed due to the product improvement.
6 Blinks
Display function of LED
Light
No Light
Light
Function Explanation Detecting method and corrective NG points
4 Blinks
10 Blinks
11 Blinks
Fan motor (Outer motor assy) NG
Replace DC motor (Fan grille assy) and
No Light
Light
No Light
Fan motor (Fan grille assy) NG
Light
No Light
19 Blinks
Light
16 Blinks
No Light
No Light
Light
5 sec
1
2
3
1 Cycle
4
1 2 6
1 Cycle
1 2
1 2 10
1
Cycle
1 2
1 2 11
1 Cycle
1 2
1 2 16
1 Cycle
1 2
1 2 19
1 Cycle
1 2
0.3 sec
0.3 sec
0.3 sec
0.3 sec
0.3 sec
0.3 sec
17
6.4 TEST POINT DIAGRAM OF MAIN CONTROL BOARD
MR-C375C-A
MR-C375CL-A
MR-C405C-A
MR-C405CL-A
CN4K
1
2
Red
Damper
3
Gray
Ice Maker Positon SW
4
Bright Yellow
Damper
5
Pink
Ice Maker & Water Pump Forward
6
White
Damper
7
Brown
Ice Maker Reverse
8
Blue
Damper
9
10
Yellow/Green
Water Pump
CN5F
8
Violet
12 VDC Common
7
Violet
12 VDC Common
6
Black
GND
5
Pink
GND
4
Orange
Outer Fan Motor FG
3
Bright Yellow
Inner Fan Motor FG
2
Light Green
Outer Fan Motor Vs
1
White
Inner Fan Motor Vs
CN6S
1
2
3
4
Yellow
Ice Maker Stop SW
CN1A
5
Red
Ice Maker Stop LED
1
Grey
6
3
Black
7
8
Blue
F Thermistor
CN2A
9
Bright Yellow
Temp Control Board
1
Grey
220 VAC Common
10
Orange
R Thermistor
3
White
Compressor
11
Gray
Temp Control Board
5
Red
Defrost Heater
12
Light Green
I Thermistor
13
Sky Blue
5 VDC Common
CN3A
14
Pink
DEF Thermistor
1
Yellow
Lamp
15
Black
GND
3
Yellow/Green
V Heater
16
Brown
Door SW
5
Brown
Ice Maker Heater
7
Sky Blue
Pipe Heater
Compulsory defrosting method
have
2
methods as below
1) Short circuit at 2-pin connector between no.6 (white wire) with no.7 (red wire)
CN7M
at Buzzer & Thermistor A.T. board.(Inside hinge cover)
1
White
12 VDC Common
2) Open door R and then adjust dial freezer at MID position. Use magnet touch
2
Red
Buzzer
door switch in order to simulate as door closing. (lamp must no light),then turn
3
Violet
A.T. Thermistor
the dial continuously as follow COLDER
LOW → MID
4 Sky Blue
5 VDC Common
5 Grey
Compulsion DEF
Parts Name
Lead color
Lead color
Parts Name
Lead color
Parts Name
Parts Name
Lead color
Parts Name
Lead color
Parts Name
Parts Name
Lead color
Lead color
220 VAC
12
VDC
5
VDC
18
DISASSEMBLY INSTRUCTIONS
MR-C375C-A
MR-C375CL-A
MR-C405C-A
MR-C405CL-A
Plug out before work. Check the automatic ice-maker by pressing ice making stop switch. In assembling & disassembling parts use several kind of screws and rivets. Do not mistake to use them.
1. Detachment Control PCB parts Photo 1
Compressor cover
(1) Detach 7 pcs. of compressor cover screws behind the
refrigerator. (Photo 1)
Elect cover
(2) Detach 4 pcs. of Elect cover screws. (Photo 2)
Elect attach Photo 2
(3) Disconnect the connector and remove Elect attach. (Photo 3)
PCB (Refcon assy)
(4) Remove the catch of elect attach to release the PCB plate.
(Photo 3)
Photo 3
Caution on assembly
[1] Firmly connect the lead wire and the connector. Ensure the
wire are not pinched.
[2] Please use the new material of sealing insulation when
re-attach.
2. Detachment Lamp cover parts Photo 4 (1) Remove parts inside the refrigerator Shelf 1,2,3 shelf
Lamp cover inside the refrigerator
(1) Push up the lower catch, and pull the room light cover toward you. (2) Detach two upper catches to take out the cover (Photo 4)
OPERATING PROCEDURE PHOTOS
7
Catch
Catch
4 x12
Stainless steel
4 x12 (Black)
With metal washer
Rivet
A B
D
C
Rivet
Lamp cover
7 fixing screws
Compressor cover
4 fixing screws
Elect cover
Elect attach
PCB
Catch
Catch
19
3. Detachment the Vegetable case parts Ph
oto 5 (1) Detach parts inside vegetable compartment (Vegetable case, Fruit case). (2) Detach the door of vegetable compartment. (3) Detach rivet (C) at the right and unhooking 2 catches at front,
(center and left). (Photo 5)
Caution on assembly
[1] Be sure to put vegetable case cover on the catches at the rear of
vegetable compartment.
Water pump motor
(4) Remove two screws and cut the lead wire of water-pump motor to
detach it.
4. Detach the refrigerator room parts Photo 6 (1) Detach parts inside the refrigerator compartment.
(2) Detach parts inside the vegetable compartment.
(3) Detach a left screw of mirror hinge and pull out the lead wire.
(Photo 7)
(4) Detach the connector.
Control panel , Duct R, Temperature control panel Photo 7
(5) Remove the upper and lower rivets (C) of right side and left side,
then unhook 7 catches.(9 catches for C405B) * Remove the right catch before push the control panel to the right and detach it. (Photo 7)
Fan grille
(6) Remove the following; Screw (A) at the upper and right center,
2 screws (B) at the left and 2 screws (B) at the right. (Photo 6) * Motor damper and thermal fuse are combined with fan grille. * Fan and fan motor are combined with fan grille.
Caution on assembly
[1] Use new tapes and sealing materials for assembly. [2] Putting some tape across joints, tape them securely so that they will
not leak the cool air.
[3] Attach a connector securely in order to prevent contact failure.
OPERATING PROCEDURE PHOTOS
Rivet
Catches
Catch
Catch
Vegetable
ca
se cover
Screw
Fan grille
F-room
Screw
Catch
CatchCatch
Catch
Catch
Catch
Screw
Lamp
Rivet
Control panel
Rivet
Rivet
Rivet
Mirror hinge
R-room
Catch
Catch
Catch
(only:C405B)
(only:C405B)
20
Defrost heater, Drip tray Photo 8
(7) Peel off the tape that fixes lead wires on the side wall
of the vegetable compartment. Then take out defrost heater together with heater roof. Detach heater roof and Heater cover from Defrost heater. Detach the drip tray after removing the defrost heater.
Defrost thermistor
(8) Cut the binder and disconnect the connector. (Photo 9)
Caution on assembly
[1] Loosen the lead wire at the defrost heather to prevent
water from entering the glass tube and careful the
direction for the correct assembly. [2] Attach the drip tray securely to the lower parts. [3] Attach the defrost thermistor in the correct place. (If
they're attached out of place, thermal characteristics
will go wrong). [4] Attach the lead wires to the fixture.
5 Detachment the parts in Freezer compartment
(1) Detach the parts inside the Freezer room (Ice spoon,
Freezing case [upper] and Freezing case [lower] ).
(2) Pull the door of Freezer compartment by pulling toward you.
Cover (upper)
(3) Detach 3 catches and remove it. (Photo 10) (4) Disconnect the connector.
Automatic ice-maker
(5) push a catch to upper and pull the part to the right
and detach it. (Photo 10)
OPERATING PROCEDURE PHOTOS
Photo 9
P
hoto 10
Evaporator
Defrost heater
Cover (upper)
Ice corner
Catch
F-room
Rivet
Rivet
Catch
DEF thermistor
Aluminium
Heater
Defrost
heater
Tape
Drip tray
Tape
Heater roof
21
6 Detachment the vegetable compartment parts Photo 11
(1) Detach the door of the vegetable compartment.
Water pipe (lower)
(2) Detach a rivet (C), pipe cover and connector. Then
remove the water pipe lower.
Water tank tray
(3) Pull Tank tray to R-room upper and take it out together
with the water pipe. Photo 12
Caution on assembly
(1) Fit the water tank tray properly in order to prevent a
water leak.
Door Switch
(4) Insert a minus screwdriver between switch and body
to remove the door switch.
OPERATING PROCEDURE PHOTOS
R-room
Water pipe
Tank tray
Water pipe
Vegetable case room
Pipe cover
22
Compressor cover
(1) Remove 7 screws for compressor cover at the back of the refrigerator.
Fan motor of compressor compartment
(2) Detach the Elect cover (3) Detach the Connector. (4) Remove a screw that fixed bell mouth. Pull out the whole fan motor and disconnect the terminals. (5) Pull out the fan from the fan motor. (6) Detach the lid-fixing screw to take out the fan motor.
7 Detachment compressor.
(1) Collect gas from the charge pipe on the high pressure side.
(2) After collecting gas, cut the charge pipe on the low pressure side.
(3) Detach the welded section of the discharge pipe and suction pipe.
(4) Replace the compressor and the dryer at a time.
Caution on assembly
(1) After attaching the compressor, must to Vacuum and charge gas from charge pipe.
(2) Arrage the piping so that the pipe will not hit each other and compressor cover, (which causes loud noise). Then
attach the compressor cover.
(3) After all the work is complete, be sure to check the cooling preformance and the gas leak from the welded points.
OPERATING PROCEDURE
W
Attach U washer as the figure shown below
: This mark shown welded point
Fan motor (Machine room)
W
W
W
Dryer
W
W
W
W
Charge pipe(Low pressure side)
23
DOOR, BODY PARTS
MR-C375C-A
MR-C375CL-A
MR-C405C-A
MR-C405CL-A
8 PARTS LIST
24
W ST OB W ST W ST W ST
KIERL6000
<G>
1
KIER66000
<G>
1
KIER63000
<G>
1
KIERN6000
<G>
1
KIERN7000
<G>
1
KIERL8000
<G>
1
KIER71000
<G>
1
KIERP0000
<G>
1
KIERP1000
<G>
1
KIEPE2002
<G>1111
KIEP90002
<G>
1
KIEP91002
<G>1111
KIEPE2001
<G>1111
KIEP90001
<G>
1
KIEP91001
<G>1111
KIEG05741
<G>
CATCHER RH
11111
KIEPE4741
<G>
CATCHER LH
111
1
5
KIEP89118
<G>
FREE POCKET L
222222222
6
KIEP89151
<G>
FRAME V ASSY
111111111
7
KIEP89157
<G>
FRAME F ASSY
111111111
8
KIEP89119
<G>
FREE POCKET S
111
1
9
KIEHJ3115
<G>
EGG CASE
111111111
KIEP89110
<G>1111
1
KIEP94110
<G>1111
11
KIEP89124
<G>
BOTTLE POCKET
111111111
12
KIEP89112
<G>
MAGNET GASKET ASSY ( V )
111111111
13
KIEP89111
<G>
MAGNET GASKET ASSY ( F )
111111111
KIERN0031
<G>1111
KIER72031
<G>1111
1
RECOMMEND PART NO. 1, 2, 3, 10, 12, 13
ABBREVIATION
ENCIRCLED PART NUMBER ARE NOT SHOWN IN THE FIGURES.
Remark
- Country code : A= Australia and New Zealand
- Colour code : W = White, ST = Stainless
PRICE/PIE
CE(US$-
FCA)
SPECPART NAME
Q'TY/UNIT
MR-C375CL-A
MR-C405CL-A
MR-C405C-A
MR-C375C-A
1
2
3
NO. PART NO.
4
BADGE ASSY
MAGNET GASKET ASSY ( R )10
14
DOOR R
DOOR V
DOOR F
RoHS
FRFREEZER ROOM
REFRIGERATOR ROOM
V
VEGETABLE ROOM
25
BODY PARTS
MR-C375C-A
MR-C375CL-A
MR-C405C-A
MR-C405CL-A
26
WSTOBWSTWSTWST
KIEP89858 <G> 1 1 1 1 1
KIEP94858 <G> 1 1 1 1 2 KIEHJ3305 <G> THERMO DIAL (R) 2 2 2 2 2 2 2 2 2 3 KIEP89802 <G> DUCT V ASSY 1 1 1 1 1 1 1 1 1 4 KIEP89818 <G> COVER DUCT V 1 1 1 1 1 1 1 1 1 5 KIEP89503 <G> WATER TRAY ASSY 1 1 1 1 1 1 1 1 1 6 KIEP89808 <G> CONNECTOR COVER 1 1 1 1 1 1 1 1 1 7 KIEPE2663 <G> FAN GRILLE ASSY 1 1 1 1 1 1 1 1 1
KIEHJ3708 <G> 1 1 1 1
KIEP91708 <G> 1 1 1 1
KIEP90708 <G> 1 9 KIEP89442 <G> PIPE COVER 1 1 1 1 1 1 1 1 1
10 KIEPE2350 <G> AUTO ICE MAKER 1 1 1 1 1 1 1 1 1 11 KIEP89652 <G> COMP COVER ASSY 1 1 1 1 1 1 1 1 1 12 KIE805794 <G> CASTER SET 2 2 2 2 2 2 2 2 2 13 KIEHJ3709 <G> SCREW LABEL (F) 2 2 2 2 2 2 2 2 2 14 KIEH79795 <G> CASTER ASSY 2 2 2 2 2 2 2 2 2 15 KIEC02460 <G> ADJUST BOLT 2 2 2 2 2 2 2 2 2
KIER65705 <G> 1 1
KIEP91705 <G> 1 1
KIEP90705 <G> 1
KIERN6705 <G> 1 1 KIEPE5705 <G> 1 1
KIEP89701 <G> 1 1 1 1 1
KIEPE4701 <G> 1 1 1 1 18 KIEP89470 <G> LAMP COVER 1 1 1 1 1 1 1 1 1 19 KIEHJ4503 <G> JOINT PIPE (TANK) 1 1 1 1 1 1 1 1 1 20 KIEHJ3531 <G> WATER TANK CAP 1 1 1 1 1 1 1 1 1 21 KIEHJ3519 <G> WATER PUMP 1 1 1 1 1 1 1 1 1 22 KIEK96527 <G> WATER TANK COVER ASSY 1 1 1 1 1 1 1 1 1
KIEMT0702 <G> 1 1 1 1 1
KIEHJ2702 <G> 1 1 1 1 24 KIEHJ3798 <G> ROLLER 4 4 4 4 4 4 4 4 4 25 KIEHJ3520 <G> WATER TANK 1 1 1 1 1 1 1 1 1 26 KIEHJ3526 <G> FILTER (TANK) 1 1 1 1 1 1 1 1 1 27 KIEP89328 <G> ELECT BOX COVER ASSY 1 1 1 1 1 1 1 1 1 28 KIEMQ4326 <G> ELECT BOX SUB ASSY 1 1 1 1 1 1 1 1 1 29 KIEHJ4442 <G> COVER (IM) 1 1 1 1 1 1 1 1 1
KIEPE2730 <G> 1 1 1 1
KIEP91730 <G> 1 1 1 1
KIEP90730 <G> 1 31 KIEPJ5663 <G> FAN GRILLE 1 1 1 1 1 1 1 1 1 32 KIEP94662 <G> BELL MOUTH 1 1 1 1 1 1 1 1 1 33 KIEHJ4682 <G> DUCT DAMPER 1 1 1 1 1 1 1 1 1 34 KIEP89336 <G> THERMAL FUSE ASSY 1 1 1 1 1 1 1 1 1
RECOMMEND PART NO. 7, 20, 22, 34
ABBREVIATION
ENCIRCLED PART NUMBER ARE NOT SHOWN IN THE FIGURES.
30 KICK PLATE
MR-C375C-A
23
1 CONTROL PANEL
16 HINGE COVER
HINGE ASSY (LOW)
RoHS
PRICE/PIECE
(US$-FCA)
SPECPART NAME
Q'TY/UNIT
MR-C405C-A
MR-C405CL-A
MR-C375CL-A
HINGE ASSY (UP) 17
PART NO.NO.
8 LABEL FC
FRFREEZER ROOM
REFRIGERATOR ROOM
IMVICE MAKER
VEGETABLE ROOM
27
ELECTRICIAL PARTS
MR-C375C-A
MR-C375CL-A
MR-C405C-A
MR-C405CL-A
28
WSTOBWSTWSTWST
1
KIEHJ3313
<G>
THERMISTOR (R)
111111111
KIEP89386
<G> 1 1 1 1 1
KIEP94386
<G> 1 1 1 1
3 KIE402360
<G> LAMP 240V 15W E12 1 1 1 1 1 1 1 1 1
4 KIEHJ3365
<G> WATER PUMP 1 1 1 1 1 1 1 1 1
5 KIEP89312
<G> THERMISTOR (DEF) 1 1 1 1 1 1 1 1 1
6 KIEHJ3378
<G> THERMISTOR (F) 1 1 1 1 1 1 1 1 1
7 KIEHJ3469
<G> GEAR BOX (IM) 1
1 1 1 1 1 1 1 1
8 KIEHJ3316
<G> THERMISTOR (I) 1 1 1 1 1 1 1 1 1
9 KIEPE2354
<G> PLUG CORD ASSY 1 1 1 1 1 1 1 1 1
10 KIEHJ3362
<G> REED SWITCH 1 1 1 1 1 1 1 1 1
11 KIEP89364
<G> WATER PIPE ASSY 1 1 1 1 1 1 1 1 1
12 KIELR4346
<G> RUNNING CAPACITOR 4µF 400VAC 1 1 1 1 1 1 1 1 1
13 KIEKA0374
<G>
BUZZER BOARD &
THERMISTOR (A.T.)
1 1 1 1 1 1 1 1 1
14 KIEMQ4363
<G> LAMP SWITCH (R) 1 1 1 1 1 1 1 1 1
15 KIEKA0382
<G> TEMP CONTROL PANEL 1 1 1 1 1 1 1 1 1
16 KIEMQ4320
<G> FAN MOTOR ASSY 1 1 1 1 1 1 1 1 1
17 KIEP89537
<G> HEATER ROOF 1 1 1 1 1 1 1 1 1
18 KIEP89392
<G> DEFROST HEATER 1 1 1 1 1 1 1 1 1
19 KIEP89397
<G> HEATER COVER 1 1 1 1 1 1 1 1 1
20 KIEP89538
<G> DRIP TRAY 1 1 1 1 1 1 1 1 1
KIERN4339
<G> 1
1 1 1 1
KIERN8339
<G> 1 1 1 1
22 KIEP89340
<G> MOTOR PROTECTOR 5TM718MFBYY53 1 1 1 1 1 1 1 1 1
23 KIEE76330
<G> PTC RELAY PTH7M330MD2 1 1 1 1 1 1 1 1 1
24 KIEG05341
<G> PROTECTOR COVER 1 1 1 1 1 1 1 1 1
25 KIEP89325
<G> OUT FAN MOTOR ASSY 1 1 1 1 1 1 1 1 1
26 KIEP89662
<G> BELL MOUTH M ASSY 1 1 1 1 1 1 1 1 1
RECOMMEND PART NO. 1, 3, 5, 6, 8, 13, 15, 18, 21, 22, 23
REFCON ASSY
21
2
LAMP SOCKET
MR-C405CL-A
RoHS
PRICE/PIE
CE(US$-
FCA)
SPECPART NAME
Q'TY/UNIT
MR-C375C-A
PART NO.NO.
MR-C375CL-A
MR-C405C-A
29
ACCESSORY AND UNIT PARTS
MR-C375C-A
MR-C375CL-A
MR-C405C-A
MR-C405CL-A
30
WSTOBWSTWSTWST
1
KIEP89420
<G>
GLASS SHELF R ASSY
111112222
2 KIEHJ3427
<G> SLIDE SHELF (REAR) 1 1 1 1 1 1 1 1 1
3 KIEHJ3428
<G> SLIDE SHELF (FRONT) 1 1 1 1 1 1 1 1 1
4 KIEP89413
<G> SLIDE CHILLED CASE 1 1 1 1 1 1 1 1 1
5 KIEP89409
<G> VEGEATABLE CASE COVER 1 1 1 1 1 1 1 1 1
6 KIEP89406
<G> FRUIT CASE 1 1 1 1 1 1 1 1 1
7 KIEP89468
<G> ICE BOX SHEET 1 1 1 1 1 1 1 1 1
8 KIEP89487
<G> ICE BOX 1 1 1 1 1 1 1 1 1
9 KIEP89474
<G> FREEZING CASE (UP) 1
1 1 1 1 1 1 1 1
10 KIEHJ3477
<G> ICE SPOON 1 1 1 1 1 1 1 1 1
11 KIEP89475
<G> F CASE (LOW) 1 1 1 1 1 1 1 1 1
12 KIEP89420
<G> GLASS SHELF R ASSY 1 1 1 1 1 1 1 1 1
13 KIEP89405
<G> VEGEATABLE CASE 1 1 1 1 1 1 1 1 1
14 KIEP89995
<G> EVAPORATOR 1 1 1 1 1 1 1 1 1
15 KIEP89504
<G> ELBOW 1 1 1 1 1 1 1 1 1
16 KIEAA1980
<G> DRYER XH-9,10GR 1 1 1 1 1 1 1 1 1
17 KIEP89435
<G> DRAIN PAN 1 1 1 1 1 1 1 1 1
18 KIEPE2277
<G> COMPRESSOR DHS66C10RAW 1 1 1 1 1 1 1 1 1
19 KIEHJ3735
<G> U WASHER 4 4 4 4 4 4 4 4 4
20 KIEE76797
<G> RUBBER MOUTH 4 4 4 4 4 4 4 4 4
RECOMMEND PART NO. 1, 2, 3, 4, 14, 16, 18
PRICE/PIE
CE(US$-
FCA)
RoHSPART NO.NO.
MR-C375CL-A
SPECPART NAME
Q'TY/UNIT
MR-C405CL-AMR-C375C-A
MR-C405C-A
31
PACKING PARTS
MR-C375C-A
MR-C375CL-A
MR-C405C-A
MR-C405CL-A
NO STEP ON
1
C.F.B BOX ASSY
6
C.F.B TOP COVER
3
PACKING COVER
5
C.F.B PALLET
4
BOTTOM CUSHION
L
R
2
TOP CUSHION
32
WSTOBWSTWSTWST
KIERN4970
<G>
1
KIERN5970
<G>
1
KIETY7970
<G>
1
KIERN6970
<G>
1
KIERN7970
<G>
1
KIERN8970
<G>
1
KIERN9970
<G>
1
KIERP0970
<G>
1
KIERP1970
<G>
1
2
KIEP89979
<G>
TOP CUSHION 1 1 1 1 1 1 1 1 1
3 KIEHN8973
<G>
PACKING COVER 1 1 1 1 1 1 1 1 1
4 KIEP89978
<G>
BOTTOM CUSHION 1 1 1 1 1 1 1 1 1
5 KIEP89974
<G>
C.F.B PALLET 1 1 1 1 1 1 1 1 1
6 KIEP89975
<G>
C.F.B TOP COVER 1 1 1 1 1 1 1 1 1
PRICE/PIE
CE(US$-
FCA)
Q'TY/UNIT
MR-C405CL-A
MR-C375CL-A
SPEC
MR-C405C-A
C.F.B BOX ASSY
PART NAME
MR-C375C-A
1
RoHS
PART NO.NO.
33
MITSUBISHI ELECTRIC CORPORATATION
HEAD OFFICE : MITSUBISHI DENKI BLDG., MARUNOUCHI,TOKYO 100. TELEX : J24532 CABLE MELCO TOKYO
Distributed by
MITSUBISHI ELECTRIC AUSTRALIA PTY LTD.
(Incorporated in New South Wales) ABN 58 001 215 792
New South Wales :
Queensland:
South Australia /
348 Victoria Road,
Unit 12, 469
Northern territory :
Rydalmere NSW 2116
Nudgee Road,
Suite 1, 224 Glen Osmond Road
Ph : (02) 9684 7777
Hendra QLD , 4011
FULLARTON SA 5063
Fax : (02) 9898 1043
Ph : (07) 3263 2000
Ph: (08) 8338 1001
Fax : (07) 3630 1888 Fax : (08) 8338 0501
Western Australia :
Victoria / Tasmania :
Far North
329 Collier Road,
Building 28, Omnico bus. Park
Queensland:
Bassendean WA 6054
270 Ferntree Gully Road,
Capricorn Air,
Ph : (08) 9377 3400
Notting Hill 3168
13 Mackley St,
Fax : (08) 9377 3499
Ph : (03) 9535 7800
Garbutt 4814
Fax : (03) 9535 7801 Ph: (07) 4775 5222
Fax : (07) 4775 5303
Distributed by
BLACK DIAMOND TECHNOLOGIES LIMITED (BDT)
Wellington Office (Head Office)
Auckland Office
Christchurch Office
1 Parliament Street
Unit1, 4 Walls Road
Suite 2, Level 1
PO Box 30-772
Penrose
37 Manderville Street
Lower Hutt
Auckland PO Box 12-726
Christchurch PO Box 1604
Ph : (04) 560 9100
Ph: (09) 526 9340
Ph : (03) 341 7052
Fax : (04) 560 9133
Fax : (09) 526 9369
Fax : (03) 341 7054
Loading...