Mitsubishi MF1103-1 Datasheet

MF1103-1
IN
7
5
39nH
39nH
6pF
6pF
OUT
IN
NCNC
Measurement Circuit
1.8
Typ.
0.90
3.00 Typ.
Typ.
0.80
Typ. 1.27
Typ.
R0.20 REF.
Typ.
R0.20 REF.
INDEX MARK
Typ.
0.10 REF
5.00 Typ.
OUT
Item Min. Center Fraquency (f0)
Frequency range
243.95 MHz – – –
Typ.
– – –
Max. – – –
Units
– – – Bandwidth (f0-3 dB) – – – ±110 ±150 – – – kHz Insertion Loss at f0 243.95 MHz – – – 4.0 5.0 dB Pass Band Ripple f0 ± 110 kHz – – – 1.0 1.5 dBp-p Group Delay Ripple f0 ± 110 kHz – – – 0.4 1.0 SEC
62.0 67.0
– – –
f0 –21.6 MHz
60.0 65.0
– – –
f
0 –10.8 MHz
40.0 50.0
– – –
f
0 – 1.2 MHz
35.0 40.0
– – –
f
0 – 0.7 MHz
28.0 35.0
– – –
f
0 – 0.6 MHz
22.0 28.0
– – –
f
0 – 0.5 MHz
25.0 30.0
– – –
f
0 + 0.5 MHz
30.0 36.0
– – –
f0 + 0.6 MHz
35.0 42.0
– – –
f
0 + 0.7 MHz
40.0 50.0
– – – – – –
f0 + 1.2 MHz
60.0 70.0f0 +10.8 MHz – – –
60.0 65.0f0 +21.6 MHz
dB
Stop band Attenuation (relative to 0 dB)
Terminal Impedance Package Size
7.0 × 5.0 × 1.8 mm
290 // 6.0 pF
Operating temperature range: –10 ~ +60°C
PRELIMINARY
FOR IF FILTER OF PHS HAND HELD
DESCRIPTION
This SAW filter for the IF filter circuit of PHS
hand held
APPLICATION
• PHS Handheld
2. Adjustment free.
3. Low insertion loss and high stop band attenuation.
4. Wide and sharp passband characteristics.
5. High stability and reliability.
6. Designed for reflow solderings.
FEATURES
ELECTRICAL PERFORMANCE
MF1103-1
MF1103-1 TYPICAL CHARACTERISTICS
Insertion Loss vs. Frequency Group Delay
S21 log MAG 2 dB / REF 0 dB CH1 S21 delay 1 µs / REF 2
Cor Avg
1
Hid
CENTER 243.950 000 MHz SPAN 1.000 000 MHz CH1 CENTER 243.950 000 MHz SPAN 1.000 000 MHz
Attenuation vs. Frequency (5 MHz Span) Attenuation vs. Frequency (50 MHz Span)
CH2 S21 log MAG 10 dB / REF 0 dB
Cor Avg
1
Hid
CENTER 243.950 000 MHz SPAN 100.000 000 MHz
Cor Avg
1 Smo
Hid
CH1 S21 SWR 10 dB / REF 0 dB
Cor Avg
15
Hid
CH1 CENTER 243.950 000 MHz SPAN 50.000 000 MHz
PACKAGE OUTLINE DIMENSIONS
– 76 –