•This manual contains text, diagrams and explanations which will guide the reader in the
correct installation and operation of the FX
2NC
and should be read and understood before
attempting to install or use the unit.
•If in doubt at any stage during the installation of the FX
2NC
always consult a professional
electrical engineer who is qualified and trained to the local and national standards. If in
doubt about the operation or use of the FX
2NC
please consult the nearest Mitsubishi Elec-
tric distributor.
•This manual is subject to change without notice.
FX
2NC
Series Programmable Controllers
FX
2NC
(D/UL) Series Programmable
Controllers
Hardware Manual
Manual number: JY992D87201
Manual revision: D
Date: November 2008
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent
licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial
property rights which may occur as a result of using the contents noted in this manual.
i
FX2NC Series Programmable Controllers
Guidelines for the safety of the user and protection of the FX
This manual provides information for the installation and use of the FX
2NC
2NC
.
. The manual has
been written to be used by trained and competent personnel. The definition of such a person
or persons is as follows;
a) Any engineer who is responsible for the planning, design and construction of automatic
equipment using the product associated with this manual should be of a competent
nature, (trained and qualified to the local and national standards required to fulfill that
role). These engineers should be fully aware of all aspects of safety with regards to automated equipment.
b) Any commissioning or service engineer must be of a competent nature, trained and qual-
ified to the local and national standards required to fulfill that job. These engineers
should also be trained in the use and maintenance of the completed product. This
includes being completely familiar with all associated documentation for the said product.
All maintenance should be carried out in accordance with established safety practices.
c) All operators of the completed product should be trained to use that product in a safe and
Note :
co-ordinated manner in compliance to established safety practices. The operators should
also be familiar with documentation which is connected with the actual operation of the
completed equipment.
The term ‘completed equipment’ refers to a third party constructed device which contains or uses the product associated with this manual.
ii
FX2NC Series Programmable Controllers
Note’s on the symbology used in this manual
At various times through out this manual certain symbols will be used to highlight points of
information which are intended to ensure the users personal safety and protect the integrity of
the equipment. Whenever any of the following symbols are encountered, its associated note
must be read and understood. Each of the symbols used will now be listed with a brief description of its meaning.
Hardware warnings
1) Indicates that the identified danger
WILL
2) Indicates that the identified danger could
cause physical and property damage.
POSSIBLY
cause physical and property damage.
3) Indicates a point of further interest or further explanation.
Software warning
4) Indicates special care must be taken when using this element of software.
5) Indicates a special point which the user of the associate software element should be aware
of.
6) Indicates a point of interest or further explanation.
iii
FX2NC Series Programmable Controllers
•Under no circumstances will Mitsubishi Electric be liable responsible for any consequential
damage that may arise as a result of the installation or use of this equipment.
•All examples and diagrams shown in this manual are intended only as an aid to
understanding the text, not to guarantee operation. Mitsubishi Electric will accept no
responsibility for actual use of the product based on these illustrative examples.
•Please contact a Mitsubishi Electric distributor for more information concerning applications
FX2NC Series Programmable ControllersIntroduction 1.
Table 1.8 : Configuration notes
AMPU-Main unit (Main Processing Unit)
BExtension block, Special function block
CConnector conversion adapter
DExtension block
ESpecial function block
FFunction adapters
GMemory board (Real time clock)
HData access units, GOT
IDedicated programming
JComputer interface
KComputer software
LTerminal block
cLeft hand side port
dMemory port
eProgramming port
fI/O port
gMPU bus port
hUnit bus port
1-13
FX2NC Series Programmable ControllersIntroduction 1.
1.5.1Summary
Connection of FX
2NC
The FX
series input extension blocks and FX
directly connected to the FX
series extension blocks only
2NC
2NC
series main unit. These input/output extension blocks can be
2NC
series output extension blocks can be
connected in the desired order. After connection, octal numbers will be assigned to the input/
output points of the extension blocks. These octal numbers are regarded as the input/output
numbers. The smallest number will be assigned to the input/output point next to the main unit,
and then sequentially increased for the subsequent input/output points.
Before connection, calculate the number of connectable input/output points by referring to Sec.
1.5.3, or quickly obtain this number using the table shown in Sec. 1.5.5.
X000-X017
2NC
FX
X: 16 points
Y: 16 points
-32MT-D/UL
X020
-
X037
16EX
16 points
X040
-
X057
16EX
16 points
16EYT
16 points
X060
-
X077
16EX
16 points
16EYT
16 points
16EYT
16 points
X100
-
X117
16EX
16 points
16EYT
16 points
Y000-Y017
Y020
-
Y037
Y040
-
Y057
Y060
-
Y077
Y100
Y117
1-14
-
FX2NC Series Programmable ControllersIntroduction 1.
Connection of FX0N and FX2N series extension blocks and function adapter
2NC
To connect the FX
series main unit to the FX0N or FX2N series extension blocks, be sure to
connect the FX
2NC
-CNV-IF connector conversion adapter first. Following the adapter, you can
connect up to 4 blocks. In addition, one special adapter can be connected to the left side of the
base unit. Before connection, calculate the number of connectable input/output points by referring to Sec. 1.5.3.
0N
FX
-232ADP (Function adapter)
FX
-D/UL
2NC
-32MT
FX
extension blocks
2NC
Series
2NC
FX
-CNV-IF (Connector conversion adapter)
FX2N-16EYR
-ES/UL
relay output
block
FX2N-232IF
RS-232C
block
4 blocks, maximum
FX2N-1PG-E
pulse output
block
FX2N-4AD
analog block
1-15
FX2NC Series Programmable ControllersIntroduction 1.
1.5.2Current consumption and input/output points
The following tables show the current consumption and input/output points of various types of
2NC
FX
series main units, extension blocks, and special function blocks.
While referring to Sec. 1.5.3, calculate the total current consumption and total input/output values using the following main unit values (values n through q), extension block values, and
special function block values.
Table 1.9 : Base units
FX
FX
FX
FX
CURRENT CAPACITY
MODEL
2NC
-16MT-D/UL600mA8816
2NC
-32MT-D/UL560mA161632
2NC
-64MT-D/UL480mA323264
2NC
-96MT-D/UL400mA484896
n
5V DC
INPUT
o
X
OUTPUT
p
Y
TOTAL
q
1-16
FX2NC Series Programmable ControllersIntroduction 1.
.
Table 1.10: Extension blocks
MODEL
2NC
FX
FX
FX
FX
FX
FX
-16EX-D/UL30mA16-16
2NC
-16EYT-D/UL50mA-1616
2NC
-32EX-D/UL60mA32-32
2NC
-32EYT-D/UL100mA-3232
0N
-8ER-ES/UL
2N
-8ER-ES/UL
FX0N-8EX-ES/UL
2N
FX
FX
-8EX-ES/UL
0N
-8EX-UA1/UL
FX2N-8EX-UA1/UL
0N
FX
-8EYR-ES/UL
FX2N-8EYR-ES/UL
0N
FX
-8EYT-ESS/UL
FX2N-8EYT-ESS/UL
0N
FX
-16EX-ES/UL40mA16-16
CURRENT CONSUMPTION
5V DC
25mA4(8)4(8)
25mA8-8
25mA8-8
30mA-88
30mA-88
INPUT
X
OUTPUT
Y
TOTAL
*1
16
0N
FX
FX
FX
FX
FX
-16EYT-ESS/UL40mA-1616
0N
-16EYR-ES/UL40mA-1616
2N
-16EX-ES/UL45mA16-16
2N
-16EYR-ES/UL40mA-1616
2N
-16EYT-ESS/UL180mA-1616
*1:8 points are used for actual input/output, however, this block should occupy 16 input/output
points.
1-17
FX2NC Series Programmable ControllersIntroduction 1.
Table 1.11: Special function block Function adapters
FX
FX
FX
FX
FX
FX
FX
FX
FX
FX
FX
FX
MODEL
0N
-3A30mA-8-8
0N
-16NT20mA8-816
2N
-2AD20mA-8-8
2N
-4AD30mA-8-8
2NC
-4AD50mA-8-8
2N
-8AD50mA-8-8
2N
-4AD-PT30mA-8-8
2N
-4AD-TC30mA-8-8
2N
-5A70mA-8-8
2N
-2DA30mA-8-8
2N
-4DA30mA-8-8
2NC
-4DA30mA-8-8
CURRENT CONSUMPTION
5V DC
INPUT
X
X/Y
OUTPUT
Y
TOTAL
FX
FX
FX
FX
FX
FX
2N
-8AD50mA-8-8
2N
-2LC70mA-8-8
2N
-1HC90mA-8-8
2N
-1PG-E55mA-8-8
2N
-10PG120mA-8-8
2N
-232IF40mA-8-8
1-18
Loading...
+ 102 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.