MITSUBISHI SOUND PROCESSORS
ICs
PRELIMINARY
Notice ; This is not a final specification.
some parametric limits are subject to change.
M65575FP
Rhythm Phrase Player
1. DESCRIPTION
The M65575FP is suitable for rhythm phrase reproduce LSI thanks to the
internal music sources and rhythm patterns.
The M65575FP contains music sources which maximum counts are 256, also
contains rhythm patterns which maximum counts are 64.
Outline 36P2R-A
0.8mm pitch 450mil SSOP
(8.4mmx15.0mmx2.0mm)
2. FEATURES
[MUSIC SOURCE]
Compression algorithm
Maximum music sources
Sampling frequency
Pronunciation counts
[Rhythm]
Maximum rhythm patterns
Tempo
Resolution ratio
[System]
Power Supply
Output
Pan pot
Level
FEATURES
4 Bit ADPCM
256
4 KHz/8 KHz/16 KHz/32 KHz
3 tracks (Monaural ; at the same time)
64 patterns
60 - 240 step 1
16 Beat
3.3V Single power supply
Stereo(L/R) Capable of both setting GAIN and Attenuate
ATT ;0 dB ,-6 dB,-12 dB,-18 dB,-24 dB,-30 dB,-36 dB, -ÅádB
GAIN;6.0 dB,5.5 dB,4.9 dB,4.2 dB,3.5 dB,2.8 dB,1.9 dB,1.0dB
Capable of set each music sources of rhythm patterns (11steps)
Capable of set each music sources of rhythm patterns
Music sources ROM size
Rhythm patterns ROM size
MCU I/F
MCU Commands
[Internal function]
Fs conversion filter
D/A converter
(0dB,-6.0dB,-9.3dB,-12dB,-15.3dB,-21.3dB, -∞dB)
1.5M Bit
96K Bit
4 line serial bus interface (clock.data,ratch,read/write)
Tempo, Rhythm pattern setting, ATT setting, Start, Repeat start,
Stop, PAD commands
Input : 4 KHz/8 KHz/16 KHz/32 KHz Output : 32KHz
D/A converter 1 Bit ∆∑ converter (PWM output)
MITSUBISHI
ELECTRIC
( / 11 )
1
DE-65575FP-93D
MCU Command
1. Input timing chart
MSD
MCK
D0 D1 D2 D3 D4 D5 D6 D7
2. Data format
There are two setting bytes with MCU commands that are 1 Byte Command
and 2 Byte Command.
Following are data formats of MCU command.
<1 Byte Command>
<2 Byte Command>
When using the 2 Byte Command, please send 1st byte at first and after,
send 2nd byte.
1st Byte
2nd Byte
3. Command Settings
<Parameter set>
No.
Command
MLAB
Command Select Command Set
D7 D6 D5 D4 D3 D2 D1 D0
Command Select Invalid
D7 D6 D5 D4 D3 D2 D1 D0
Command Set
D7 D6 D5 D4 D3 D2 D1 D0
Function
Byte
Counts
(1)
(2)
Rhythm pattern select A
(3)
Rhythm pattern select B
Rhythm pattern select C
(4)
Gain/Attenuate level control
(5)
<Start/Stop/Pad Control set>
No.
(6)
(7)
<Software reset / Test Control set>
No.
Tempo
Command
Start/Stop control
PAD control
Command
Tempo setting Normal:60~160 step 1
Triplet tempo :90~240 step 1
Presetting the rhythm pattern from
the internal 64 (MAX) rhythm pattern.
Capable of presetting 3 patterns
(A,B,C)
Gain/Attenuate level setting
6.0,5.5,4.9,4.2,3.5,2.8,1.9,1.0,
0,-6,-12,-18,-24,-30,-36,-∞ dB
Function
Rhythm start/stop control
Function
2
2
1
Byte
Counts
1
2PAD control (2 systems)
Byte
Counts
(8)
Reset/Test
( / 11 )
4
1Software reset,Test mode (shipment test)