Mitsubishi Electric LOSSNAY LGH-15RX4-E,LOSSNAY LGH-200RX4-E,LOSSNAY LGH-150RX4-E Operating Instructions Manual

Page 1
1
English
Names of the parts
Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4
Safety precautions
The following signs indicate that death or serious injury may be caused by a failure to heed the precautions described below and the resultant mishandling of the product.
This product must not be disassembled under any circumstances. Only authorized repair technicians are qualified to conduct disassembly and repairs. (Failure to heed this warning may result in fire, electrical shock or injury.) If your product needs to be repaired, consult your dealer.
Do not splash water over this product. (Failure to heed this warning may result in fire and/or electrical shock.)
If flammable gases should leak, do not turn the Lossnay’s switch on or off. (Failure to heed this warning may cause the electrical contacts to generate sparks which may result in an explosion.) Open windows to ventilate.
Do not poke your fingers or sticks into the air intake and outlet while the product is operating. (Failure to heed this warning may result in injury.)
Gloves should be worn when doing the installation and maintenance work. (Failure to heed this warning may result in injury.)
Be sure that the power board circuit breaker is in the OFF position and is securely locked by lock and key before proceeding with maintenance work. (Failure to heed this warning may result in electrical shock or injury.)
In the event of trouble (smell of burning, etc.), shut down operation, set the power board circuit breaker to its OFF position and consult your dealer. (Continued operation without remedying the trouble may result in electrical shock, fire, etc.)
No
disassembly
Prohibited
Instructions
must be followed
Do not touch
Please read through these instructions in order to familiarize yourself with the proper and safe procedures for operat­ing the Lossnay. After reading this manual, keep it in an easily accessible and safe place for future reference.
LGH-15RX4-E, LGH-25RX4-E, LGH-35RX4-E LGH-50RX4-E, LGH-65RX4-E, LGH-80RX4-E LGH-100RX4-E, LGH-150RX4-E, LGH-200RX4-E
Lossnay
Models:
Operating Instructions (For the user)
2 Control box
3 Lossnay core holder
7 Air filter
5 Lossnay core
4 Air supply fan
1 Maintenance cover
8 Damper plate6 Air exhaust fan
3 Lossnay core holder
7 Air filter
5 Lossnay core
1 Maintenance cover
2 Control box 4 Air supply fan
8 Damper plate
6 Air exhaust fan
Page 2
2
1. For connection of a remote controller (PZ-41SLB-E)
If the Lossnays operation is linked with the operation of an external device such as an air conditioner, the method of use will differ, so carry out the appropriate operation in accordance with the following table. Also, please see the installation and users manual for the remote controller (PZ-41SLB-E).
<If not connected to an external device>
2. For connection of a Lossnay remote controller (PZ-52SF-E), Mitsubishi Electric Air-Conditioner Network System (MELANS) or City Multi.
This is to be incorporated and used in the Mitsubishi Electric Air­Conditioner Network System. This is interlocked with the City Multi and operated by it. If the Lossnay remote controller (PZ-52SF-E) is used, the Lossnay may be operated independently if connected to City Multi. For details, refer to the operating manual of PZ-52SF-E.
Lossnay operation using the Lossnay remote controller (PZ-52SF­E) should need the power supply unit. Refer to the system diagram below.
Note
• If this is to be used with the Lossnay remote controller (PZ­52SF-E), refer to the manuals for both the PZ-52SF-E instal­lation and operating manual.
• Remote controller PZ-41SLB-E cannot be used with this sys­tem.
System diagram
Power supply unit
Power supply
MELANS
PAC-SC34KUA
Lossnay unit LGH-**RX
4-E
Lossnay remote controller (PZ-52SF-E)
M-NET transmission line
Basic system
LOSSNAY VENTILATE setting
Both fresh air supply and return air pass through the Lossnay core(s). Resulting in full heat exchange. Lossnay ventilate setting is used for cooling in the summer and heating in the winter period.
BY-PASS VENTILATE setting
The fresh air passes through the Lossnay core(s) and the return room air is exhausted direct. Lossnay bypass ventilate is normally operated during the spring/autumn months.
<If connected to an external device>
Example of System Function
If 2 remote controllers are used, the last controller to be used has priority. (Last Command)
Operation
Run using the remote controller.
City Multi indoor unit
Power supply
A/Cs remote controller
Lossnay unit LGH-**RX
4-E
M-NET transmission line
Interlocked to the City Multi indoor unit
Operation
If you would like to turn ON the Lossnay alone while the external device is OFF, operate it by the Lossnay remote control­ler.
The fan speed is on High.
The ventilation mode is Ventilation Mode Auto Select”.
If an external device is connected the On/Off function of this device will also control the Lossnay operation.
Lossnay
Power Supply
Remote Controller
(Optional parts)
(PZ-41SLB-E)
Lossnay
Power Supply
External device
Remote Controller
(Optional parts)
(PZ-41SLB-E)
Power Supply
Operation switch for the external device
Lossnay
Power Supply
Power Supply
Operation switch for the external device
External device
AUTOMATIC VENTILATION setting
The automatic damper mode automatically provides the correct ven­tilation for the conditions in the room. The following shows the effect By-pass ventilation will have under various conditions.
Fresh air
Exhaust air
Lossnay core
Damper
Return air
Damper
Return air
Supply air
Supply air
Lossnay core
Exhaust air
Fresh air
Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4
Exhaust air
Fresh air
Lossnay core
Damper
Return air
Supply air
Exhaust air
Fresh air
Lossnay core
Damper
Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4
Fresh air
Exhaust air
Return air Supply air
Return air Supply air
Return air Supply air
Exhaust air Fresh air
Page 3
3
English
Remove all dust and dirt on air filters and Lossnay core(s) at regular intervals in order to prevent a deterioration in the Lossnay functions. Guideline: Clean the air filters once a year.
Clean the Lossnay core(s) once two year.
Removing the parts
1) Maintenance cover
Locate and remove the cover fixing screw. Pull back the hinged clip. Open the door and lift off of the hinge brackets.
2) Lossnay core(s)
Take hold of the handle and draw the Lossnay cores out from the main unit.
Model LGH-15 RX4: .................................................. 1 core
Models LGH-25 to 100 RX4: ..................................... 2 cores
Models LGH-150 and 200 RX4: ................................ 4 cores
3) Air filters
After pulling out the Lossnay core(s), pull the air filters, located at the bottom left and right of the Lossnay core(s), off the velcro that holds them in place.
Models LGH-15 RX4: ................................................ 2 filters
Models LGH-25 to 100 RX4: ..................................... 4 filters
Models LGH-150 and 200 RX4: ................................ 8 filters
Cleaning the parts
1) Air filters
Use a vacuum cleaner to remove light dust. To remove stubborn dirt wash in a mild solution of detergent and lukewarm water. (under 40°C)
CAUTION
Do not use the hard nozzle of the vacuum cleaner. It may damage the exposed surfaces of the Lossnay core(s).
Under no circumstances should the Lossnay core(s) be washed in water.
Maintenance
Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4
CAUTION
Never wash the filters in very hot water and never wash them by rubbing them.
Do not dry the filters by exposing them to a flame.
2) Lossnay core
Use a vacuum cleaner to suck up the dust and dirt on the exposed surfaces of the Lossnay cores. Use a soft brush only to clean ex­posed surface areas.
Corner Vacuum cleaner
(with brush attachment)
Lossnay core
Do NOT wash in water.
Vacuum cleaner
Air filter
Hinge
Hinge bracket
Maintenance cover
Maintenance covers
Hinge
Operation (Continued)
1. Reduces cooling load
If the air outside is cooler than the air inside the building during the cooling season (such as early morning or at night), By-pass ventilation will draw in the cooler outside air and reduce the cool­ing load on the system.
2. Night purge
By-pass ventilation can be used to release hot air from inside the building that has accumulated in buildings a business district during the hot summer season.
3. Office equipment room cooling
During cold season, outdoor air can be drawn in and used as is to cool rooms where the temperature has risen due to the use of office equipment. (Only when interlocked with City Multi and Mr. Slim indoor unit)
Air filters
Velcro
Lossnay core
Handle
Handle
Lossnay
core
Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4
Lossnay core
Main unit
Hinge bracket
Page 4
4
Specifications
* The values given in the table for the noise level reflect the levels measured at a position 1.5 meters immediately below the unit in an anechoic
chamber.
* The noise at the air outlets is the values at a 45° angle, 1.5 meters in front of the unit.
* The above values apply during Lossnay ventilation when the fan speed is set to high speed.
* The values for 150 and 200 type main unit outlet noise show in the case of 1 supply air duct.
Model name
Voltage (V)
Line
frequency
(Hz)
Current (A)
Power
consumption
(W)
Static
pressure
Air volume Noise (dB(A))
Exchange efficiency (%)
Weight
(kg)
Air
outlets
Below
the unit
(m /h)
3
(L/S)
Temperature
Enthalpy
Heating Cooling
1-Phase
220 - 240
LGH- 15RX
4
50 0.29-0.31 63-73 150 42 7760 70 64.5 17
1-Phase
220 - 240
LGH- 25RX
4
50 0.39-0.40 85-96 250 69 7850 70 65 21
1-Phase
220 - 240
LGH- 35RX
4
50 0.71-0.71 154-167 350 97 7970 70 68 30
1-Phase
220 - 240
LGH- 50RX
4
50 0.89-0.90 193-214 500 139 7760 67.5 64.5 33
1-Phase
220 - 240
LGH- 80RX
4
50 1.60-1.60 340-370 800 222 78100 71 67 61
1000
1-Phase
220 - 240
LGH- 150RX
4
50 3.10-3.10 670-730 1500 417
79
100
72 68
35.5-36.5
124
1-Phase
220 - 240
LGH- 200RX
4
50
(1mmH2O = 9.80665Pa)
4.20-4.20 910-980 2000 556
7990 71 67 140
6.1
5.1
7.1
6.1
10.2
10.2
1-Phase
220 - 240
LGH- 100RX
4
50 2.00-2.00 440-475 278 79100 71 67 69
10.2
9.2
(mmH2O)
(Pa)
60Hz : Invalid in EU
60 0.33-0.35 72-84 150 42 77 708.2 80 64.5 17
60
0.45-0.47 98-112 250 69 78 706.1 60 65 21
60
0.83-0.87 180-207 350 97 79 705.1 50 68 30
60 1.05-1.10 231-262 500 139 77 67.56.1 60 64.5 33
60
3.80-3.90 820-935 1500 417
79 72
12.2
120 68 124
30-31.5
33-34
35-37
37.5-39.5
43-44
44-45
45.5-46.5
45-46
31-32.5
33.5-34.5
34-36
36.5-39
43.5-44.5
24-25
25-26
28-30
29.5-31.5
32-33
37-38
34-35
25-26
25.5-26.5
27-29
28.5-31
1-Phase
220 - 240
LGH- 65RX
4
50 1.30-1.30 270-300 650 181 7650 68 64.5 465.1
60 1.50-1.60 320-370 650 181 76 687.1 70 64.5 46
40.5-41
40.5-41
32.5-33
32.5-33
60
2.60-2.70 565-635 1000 278
79 71
11.2
110 67 6945-4734-36
60
1.90-2.00 405-465 800 222 78 7112.2 120 67 6142-43.531-32.5
35-36
60
5.30-5.40 1155-1295 2000 556
79 71
10.2
100 67 14045-47
36.5-38.5
Consult with your dealer about the after-sales services provided for this Lossnay product.
After-sales servicing
Assembly after maintenance
1. Bearing in mind the following points, assemble the parts following the sequence for their removal in reverse.
Attach the air filters to the magic tape on the Lossnay core(s).
Arrange the Lossnay core with the air filter side downward.
2. Press the filter button on the remote controller (PZ-41SLB-E) two times in succession. (This clears the Lossnays operating time cumulative data.)
Maintenance (Continued)
If you hear strange sounds, if no air is blown out or if some other trouble occurs, switch off the power and contact your dealer. Consult with your dealer concerning the cost of inspection or repair work.
Relevant button
FILTER
(Press twice)
FILTER
Relevant display items