GT15 Serial communication unit
User's Manual
GT15-RS2-9P
GT15-RS4-9S
GT15-RS4-TE
Thank you for purchasing the GOT1000 Series.
Prior to use, please read both this manual and detailed
manual thoroughly to fully understand the product.
MODEL GT15-RS2/4-U
MODEL
CODE
IB(NA)-0800325-A(0507)MEE
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".
Indicates that incorrect handling may cause
DANGER
CAUTION
Note that the CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the precautions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury
or physical damage.
1D7M40
[DESIGN PRECAUTIONS]
DANGER
z Do not bunch the control wires or communication cables with
the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100 mm
(3.94 inch) otherwise malfunctions may occur due to noise.
[INSTALLATION PRECAUTIONS]
DANGER
z Be sure to shut off all phases of the e xter na l powe r su pp ly used
by the system before mounting or removing this unit to/from the
GOT.
Not doing so can cause a unit failure or malfunction.
z Before connecting the Bus connection cable to this unit, always
shut off GOT power and PLC CPU power externally in all
phases.Not doing so can cause a malfunction.
CAUTION
z Use this unit in the environment given in the general
specifications of the GT15 User's Manual.Not doing so can
cause an electric shock, fire, malfunction or product damage or
deterioration.
z When installing this unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the
specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to
screw or unit damage.
[WIRING PRECAUTIONS]
DANGER
z Be sure to shut off all phases of the e xter na l powe r su pp ly used
by the system before wiring.
Failure to do so may result in an electric shock, product damage
or malfunctions.
CAUTION
z Use crimp-contact, pressure-displacement or soldering to wire
the connectors for external connections properly using the
manufacturer-specified tools.
If the connection is incomplete, it may cause the module to shor t
circuit, catch fire, or malfunction.
z Connect the connectors to the unit securely.
z Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them.
Not doing so can cause unit or cable damage due to dangling,
moved or accidentally pulled cables or can cause a malfunction
due to a cable contact fault.
[STARTUP AND MAINTENANCE PRECAUTIONS]
DANGER
z Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or
malfunction.
CAUTION
z Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this
unit directly.
Doing so can cause a unit malfunction or failure.
z Exercise care to avoid foreign matter such as chips and wire
offcuts entering the unit.
Not doing so can cause a fire, failure or malfunction.
z Do not hold the cable part when unplugging any cable
connected to the unit. Doing so can cause unit or cable damage
or a malfunction due to a cable contact fault.
z Always make sure to touch the grounded met al to discha rge the
electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.
[DISPOSAL PRECAUTIONS]
CAUTION
z Dispose of this product as industrial waste.
[TRANSPORTATION PRECAUTIONS]
CAUTION
z Make sure to transport the GOT main unit and /or relevant u nit(s)
in the manner they will not be exposed to the impact exceeding
the impact resistance described in the general specifications of
the GT15 User's Manual, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Manuals
The following shows manuals relevant to this product.
Detailed Manual
Manual name
GT15 User's Manual
GOT1000 Series Connection Manual
(Option)
(Option)
Relevant Manuals
For relevant manuals, refer to the PDF manu al st ored within the
drawing software used.
© 2005 MITSUBISHI ELECTRIC CORPORATION
Product Componets
The serial commnunication units consists of the following items.
Model name Product mane Quantity
GT15-RS2-9P
GT15-RS4-9S
GT15-RS4-TE
* For handling of the ferrite core, ref er to "For users inte nding to
GT15-RS2-9P 1
Mounting screw set (2 screws, 2 labels) 1
GT15-RS4-9S 1
Mounting screw set (2 screws, 2 labels) 1
Ferrite Core* 1
GT15-RS4-TE 1
Mounting screw set (2 screws, 2 labels) 1
Te rminal block socket 1
connect the GOT directly to a PLC using the RS-422 cable
(GT01-C30R4-25P)" provided with the product.
Manual Number
(Type code)
SH-080528ENG
(1D7M23)
SH-080532ENG
(1D7M26)
1. Overview
This User's Manual describes the GT15 Serial communication
unit. (hereafter abbreviated to the serial communication unit)
The following shows the kinds of the serial communication unit.
For attachable GOTs, refer to the GT15 User's Manual.
Model name Description
GT15-RS2-9P
GT15-RS4-9S
GT15-RS4-TE
The serial communication unit is used when performing the
serial communication between GOT and a FA device.
Select a serial communication unit according to the connection
type.
For the details of connection types, refer to the GOT1000
Series Connection Manual.
RS-232 serial communication unitInterface: D-Sub
9-pin (Male)
RS-422/485 serial communication unitInterface: DSub 9-pin (Female)
RS-422/485 serial communication unitInterface:
Terminal block
2. Specifications
2.1 Performance Specifications
The performance specifications of the serial communication
unit are indicated below.
Refer to the used GT15 User's Manual for the general
specifications of the serial communication unit.
Item
Transmission
method
Interface
Transmission speed 1 15200/57600/38400/19200/9600/4800bps
Synchronous type Non-Synchronous type (Asynchronous type)
Error detection
method
Maximum
transmission
distance
Imternal current
consumption(5V)
Weight 0.09kg
* The maximum transmission distance differ s depending on the
controller connected.
For details, refer to the GOT1000 Series Connection Manual.
GT15-RS2-9P GT15-RS4-9S GT15-RS4-TE
RS-232
compliant
D-sub 9-pin
(Male)
15m 1200m* 1200*
2.2 Specifications of terminal block socket
Item Specifications
Screw tightening torque 0.20 to 0.25 [N•m
Recommended driver
Applicable wire size 0.08 to 1.5 [mm
DIN 5265: ISO 2380/2 compliant product
DIN 5264: Product with the tip chrome-plated
based on the ISO 2380/1 standard
Specification
RS-422/485
compliant
D-sub 9-pin
(Female)
Parity check, sum check
0.20A
2
]
2
]
RS-22/485
compliant
Term inal block
3. Name of the Parts and External Dimensions
(1) GT15-RS2-9P / PS4-9S
63 (2.48)
1)
7)
2.5
(0.10)
30.5 (1.2)
(2) GT15-RS4-TE
30.5 (1.2)
21.5
1)
7)
2.5
(0.10)
21.5
(0.85)
(0.85)
4)
31.5
(1.24)
63 (2.48) 3
4)
(3) Back view (GT15-RS4-9S / TE)
(Expanded figure of part 6))
12
29.5
(1.16)
GOT main
3
unit
(0.12)
98 (3.89)7
(0.12)
3)
112 (5)
(0.28)
9
(0.35)
98 (3.89)
117 (4.61)
12
(0.47)
11. 5
GOT main
unit
3)
(0.45)
0.5
(0.02)
X
0.5
(0.02)
X
5)
Dimensions of X when mounted to the GOT.
8.4” 23 (0.91)
10.4”, 12.1”, 15” 21 (0.83)
ON KSD22S
6)
SW1
ON
100 OHM
2)
2
Unit: mm (inch)
No. Name Description
1) Mounting screw
Interface
2)
connector
Extension
3)
connector
Serial
4)
communication
connector
Terminal block
5)
socket
DIP switch
6)
(For GT15-RS49S/TE only)
7) Rating plate -
Mounting screws fixed with the front
communication unit or GOT.
Connector connected to the front communication
unit or GOT.
Connector with which the back communication
unit is fixed.
Connector for connecting a serial communication
cable (For GT15-RS4-TE, the terminal block
socket is connected.)
Connects a serial communication cable to the
serial communication connector.
Switch to set terminating resistor.When using the
built-in terminating resistor (100
1 and No. 2 switches on.When using the external
terminating resistor, tu rn both No. 1 and No. 2
switches off.
Ω), turn both No.
4. Installation Procedure
4.1 Serial communication unit installation
The following figures show an example of the GT15-RS2-9P/
RS4-9S installation.The installation of the GT15-RS4-TE
follows the same procedure.
(1) Power off the GOT.
(2) Remove the one extension unit covers of the GOT.
(3) Fit the Ethernet communication unit along th e groove
of the GOT case.
(4) Fasten the Ethernet communication unit by tighte ning
its mounting screws (2 places) with tightening torque
0.36 to 0.48 N•m.
(5) When installing a communication unit on the outer
layer, remove the connector cover and peel the seal.
When not mounting any communication unit on the
outer layer, stick accessory labels on the top of
mounting screws (2 places) to cover the top of them
in order to avoid receiving electrostatic.
Keep the connector cover fixed.
Keep the seal stuck as it is.
ccessory
labels
Connector
cover
Seal
Point
If you remove the serial communication unit, detach it from
specified direction (shown PULL) so as not to break a connector.
4.2 Terminal block socket installation
(For GT15-RS4-TE only)
(1) Insert the terminal block socket in the serial
communication unit.
A
(2) Fasten the terminal block by tightening the terminal
block fixing screws (2 places) with the tightening
torque of 0.20 to 0.25 N•m.
(Expanded figure of part A)
A terminal block fixing screw
Point
When attaching or removing a communication cable to/from the
terminal block socket, detach the terminal block socket from the
connector.
(When communication units are installed in multiple layers, the units
do not have to be removed from the GOT main unit.)
Warranty
Mitsubishi will not be held liable for damage caused by factors found
not to be the cause of Mitsubishi; machine damage or lost profits
caused by faults in the Mitsubishi products; damage, secondary
damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
For safe use
• This product has been manuf actured as a g eneral- purpose pa rt for
general industries, and has not been de si gne d o r ma nu factured to
be incorporated in a device or system used in purposes related to
human life.
• Before using the product for special purposes such as nuclear
power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control.
However, when installing the product where major accidents or
losses could occur if the product fails, install ap propriate ba ckup or
failsafe functions in the system.
ountry/Region Sales office/Tel
U.S.A Mitsubishi Electric Automation Inc.
Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
ermany Mitsubishi Electric Europe B.V. German Branch
U.K Mitsubishi Electric Europe B.V. UK Branch
Italy Mitsubishi Electric Europe B.V. Italian Branch
pain Mitsubishi Electric Europe B.V. Spanish Branch
France Mitsubishi Electric Europe B.V. French Branch
outh Africa Circuit Breaker Industries LTD.
Hong Kong Ryoden Automation Ltd.
hina Ryoden Automation Shanghai Ltd.
aiwan Setsuyo Enterprise Co., Ltd.
Korea HAN NEUNG TECHNO CO.,LTD.
ingapore Mitsubishi Electric Asia Pte, Ltd.
hailand F. A. Tech Co.,Ltd.
Indonesia P.T. Autoteknindo SUMBER MAKMUR
India Messung Systems Put,Ltd.
ustralia Mitsubishi Electric Australia Pty. Ltd.
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
500 Corporate Woods Parkway Vernon Hills, IL 60061
Tel : +1-847-478-2100
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
Travellers Lane, Hatfield, Herts., AL10 8XB,UK
Tel : +44-1707-276100
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Tel : +39-039-6053344
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France
TEL: +33-1-5568-5568
Tripswitch Drive, Elandsfontein Gauteng, South Africa
Tel : +27-11-928-2000
10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870
3F Block5 Building Automation
Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China
Tel : +86-21-6120-0808
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang,
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong
Kangsec-ku, Seoul, Korea
Tel : +82-2-3660-9552
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building Singapore 159943
Tel : +65-6473-2308
898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3
Road, Bangkpongpang, Yannawa, Bangkok 10120
Tel : +66-2-682-6522
Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan
Industri/Pergudangan Jakarta - Utara 14440
Tel : +62-21-663-0833
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,
PUNE-411026, India
Tel : +91-20-712-2807
348 Victoria Road, PostalBag, No 2,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
Specifications subject to change without notice.
Printed in Japan on recycled paper.