Mitsubishi Electric GT15-J71GP23-SX User Manual

GOT2000/GOT1000 Series
CC-Link IE Controller Network
Communication Unit
User's Manual
GT15-J71GP23-SX
Thank you for choosing Mitsubishi Electric Graphic Operation Te rm in a l ( GO T) .
Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.
MODEL GT15-J71GP23-SX-U
MODEL
CODE
IB(NA)-0800412-I(1806)MEE
1D7M76

SAFETY PRECAUTIONS

WARNING
CAUTION
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the precautions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and always forward it to the end user.
A-1
[DESIGN PRECAUTIONS]
WARNIN G
CAUTION
If a communication fails in data link, the faulty station holds the data link data
generated before the communication error. Create an interlock circuit in the sequence program using the communication status information in order that the system will operate safely. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents. Check the faulty station and the operation status during communication error by referring to the relevant manuals.
Some failures of cable or communication unit may cause the GOT to keep the
outputs on or off. Create an external circuit for monitoring output signals that may lead to serious accidents. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents.
If a communication error (including cable disconnection) occurs during
monitoring, the communication between the GOT and programmable controller CPU may be interrupted and the GOT may be inoperative.
For bus connection : The programmable controller CPU is down and the
For other than above: The GOT is inoperative. When configuring a system including the GOT, the possibility of GOT communication error must be considered; make sure the operation significant for the system will be performed by switches on devices other than the GOT. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents.
Laser diodes are used in optical transceivers for the CC-Link IE Controller
Network. The class of these laser diodes is Class 1.
GOT is inoperative.
Do not bunch the control wires or communication cables with the main circuit
or power wires, or lay them close to each other. As a guide, separate the lines by a distance of at least 100mm (3.94 inches) otherwise malfunctions may occur due to noise.
A-2
[INSTALLATION PRECAUTIONS]
WARNIN G
CAUTION
WARNIN G
Be sure to shut off all phases of the external power supply used by the system
before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction.
Use this unit in the environment that satisfies the general specifications
described in the User's Manual for the GOT used. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
When installing this unit to the GOT, fit it to the connection interface of the
GOT and tighten the mounting screws in the specified torque range (0.36 N•m to 0.48 N•m) with a Phillips-head screwdriver No.2. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage.
Do not directory touch the conductive part or electronic components of the
unit. This may cause the unit to fail or malfunction.
[WIRING PRECAUTIONS]
Be sure to shut off all phases of the external power supply used by the system
before wiring. Failure to do so may cause electric shock, product damage or malfunctions.
A-3
[WIRING PRECAUTIONS]
CAUTION
WARNIN G
Be careful not to let foreign matter such as dust or wire chips get inside the
unit. This may cause a fire, failure or malfunctions.
Make sure to securely connect the cable to the connector of unit.
Incorrect connection may cause malfunctions.
Make sure to fix communication cables and power cables to the unit by ducts
or clamps. Failure to do so may cause damage of the unit or the cables due to accidental pull or unintentional shifting of the cables, or malfunctions due to poor contact of the cables.
Do not hold the cable by hand and pull it out from the unit.
When removing the cable from the unit, make sure to hold the connector by hand and pull it. Failure to do so may cause malfunctions or damage to the unit or cable.
[STARTUP AND MAINTENANCE PRECAUTIONS]
Do not touch the connector while power is on.
Failure to do so may cause electric shock or malfunctions.
Before starting cleaning, always shut off GOT power externally in all phases.
Not doing so can cause a unit failure or malfunction.
A-4
[STARTUP AND MAINTENANCE PRECAUTIONS]
CAUTION
CAUTION
CAUTION
Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
Do not touch the conductive areas and electronic parts of this unit directly.
Doing so can cause a unit malfunction or failure.
Make sure to externally shut off all phases of the power supply before
cleaning the unit and retightening unit mounting screws. Failure to do so may cause the unit to fail or malfunction. Loose tightening may cause a fall of the unit, short circuits, or malfunctions. Overtightening may damage the screws and/or the unit, resulting in a fall of the unit, short circuits or malfunctions.
Make sure to touch the grounded metal to discharge the electricity charged in
the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit.
[DISPOSAL PRECAUTIONS]
Dispose of this product as industrial waste.
[TRANSPORTATION PRECAUTIONS]
Make sure to transport the GOT main unit and/or relevant unit(s) in the
manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of Use this unit in the environment that satisfies the general specifications described in the User's Manual for the GOT used, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.
When fumigants that contain halogen materials such as fluorine, chlorine,
bromine, and iodine are used for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our products.Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products, or treat packaging with methods other than fumigation (heat method).Additionally, disinfect and protect wood from insects before packing products.
A-5

REVISIONS

* The manual number is noted at the lower right of the top cover.
Print Date *Manual Number Revision
Jan., 2008 IB(NA)-0800412-A First edition
Jan., 2009 IB(NA)-0800412-B Patial addition
Jun., 2009 IB(NA)-0800412-C Partial corrections
Jun., 2011 IB(NA)-0800412-D Partial corrections
Oct., 2014 IB(NA)-0800412-E Partial corrections
May, 2014 IB(NA)-0800412-F Partial corrections
Oct., 2016 IB(NA)-0800412-G Partial corrections
Apr., 2017 IB(NA)-0800412-H Partial corrections
Jun., 2018 IB(NA)-0800412-I Patial addition
Chapter 1, 2, 4, 7
Compliance with the EMC and Low Voltage Directives
Chapter 7 Patial addition Compliance with the Radio Waves Act (South Korea)
SAFETY PRECAUTIONS Chapter 4, 7
Cover
Compliance with the RoHS
Cover
Compliance with Chinese standardized law
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
© 2008 MITSUBISHI ELECTRIC CORPORATION
A-6
Loading...
+ 15 hidden pages