Mitsubishi Electric GT1155-QTBD, GT1155-QLBD, GT1155-QSBD Instructions Manual

JY997D17401H
GT1155-QTBD, GT1155-QSBD, GT1150-QLBD
GT11 General Description
Manual Number JY997D17401H
Date Jul. 2008
This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions. And, store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user. Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company.
Effective May 2008 Specifications are subject to change without notice.

Safety Precaution

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
DESIGN PRECAUTIONS
Some failures of the GOT or cable may keep the outputs on or off. An external monitoring circuit should be provide d to check for output signals which may lead to a serious accident. Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative. A system where the GOT is used should be configured to perform any significant operation to the sys tem by using the switches of a devi ce other than the GOT on the assumption that a GOT communication fault will occur. Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious accident. An independent and redundant hardware or mechanical inte rlock is required to configure the device that displays and outputs serious warning. Failure to observe this instruction may result in an accident due to incorrect output or malfunction.
Incorrect operation of the touch switch(s) may lead to a serious accident if the GOT backlight is gone out. When the GOT backlight goes out, the POWER LED flickers (green/orange) and the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) remains active. This may confuse an operator in thinking that the GOT is in "screensaver" mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate. Note that the following occurs on the GOT when the backlight goes out.
- The PO WER LED flickers (green/orange) and the monitor screen appears blank
DESIGN PRECAUTIONS
Do not bundle the control and communication cables with main-circuit, power or other wiring. Run the above cables separately from such wiring and keep them a minimum of 100mm (3.94in.) apart.Not doing so noise can cause a malfunction.
© 2008 Mitsubishi Electric Corporation
(Read these precautions before using.)
MOUNTING PRECAUTIONS
Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel. Not doing so can cause the unit to fail or malfunction.
When installing the battery, or operating the reset switch, wear an earth band etc. to avoid the static electricity. The static electricity can cause the unit to fail or malfunction.
MOUNTING PRECAUTIONS
Use the GOT in the environment that satisfies the general specifications described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range. Undertightening can cause the GOT to drop, short circ uit or malfunction. Overtightening can caus e a drop, short circuit or malfunc tion due to the damage of the screws or the GOT.
When inserting/removing a CF card into/from the GOT, turn the CF card access switch off in advance. Failure to do so may corrupt data within the CF card.
When inserting a CF card into the GOT, push it into the insertion slot until the CF card eject button will pop out. Failure to do so may cause a malfunction due to poor contact.
When removing a CF card from the GOT, make sure to support the CF card by hand, as it may pop out. Failure to do so may cause the CF card to drop from the GOT and break.
WIRING PRECAUTIONS
Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.
Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.
Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT. Not doing so can cause a fire, failure or malfunction.
WIRING PRECAUTIONS
Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
TEST OPERATION PRECAUTIONS
Before performing the test operations of the user creation monitor screen (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through the manual carefully and make yourself familiar with the operation method. During test operation, never change the data of the devices which are used to perform significant operation for the sys tem. False output or malfunction can cause an accident.
STARTUP/MAINTENANCE PRECAUTIONS
When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction.
Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or throw the battery into the fire. Incorrect handlin g may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.
Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not switching the power off in all phases can cause a unit failure or malfunction . Undertightening can cau se a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
STARTUP/MAINTENANCE PRECAUTIONS
Do not disassemble or modify the unit. Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly. Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped. Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull the cable portion. Doing so can cause the uni t or cable to be damaged or can cause a malfunction due to a cable connection fault.
Do not drop or apply any impact to the battery.If any impact has been applied, discard the battery and never use it. The battery may be damaged by the drop or impact.
Before touching the unit, always touch grounded metal, etc. to discharge static electricity from human body, etc. Not doing so can cause the unit to fail or malfunction.

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are required, please consult with our local distributor.
Manual name Contents
GOT1000 Series Extended/Option Function Manual (sold separately)
GOT1000 Series Connection Manual 1/3, 2/3, 3/3 (sold separately)
GT Designer2 Version2 Basic Operation/Data Transfer Manual (For GOT1000 Series) (sold separately)
GT Designer2 Version2 Screen Design Manual (For GOT1000 Series) 1/3, 2/3, 3/3 (sold separately)
*1 Stored in the GT Works 2/GT Designer2 in PDF format.
For details of a PLC to be connected, refer to the PLC user's manual respectively.
*1
*1
*1
*1
Describes extended functions and option functions applicable to GOT1000 series.
Describes system configurations of the connection method applicable to GOT1000 series and cable creation method
Describes methods of the GT Designer2 installation operation, basic operation for drawing and transmitting data to GOT1000 series
Describes specifications and settings of the object functions used in GT Designer2
DISPOSAL PRECAUTIONS
When disposing of the product, handle it as industrial waste.
TRANSPORTATION PRECAUTIONS
When transporting lithium batteries, make sure to treat them based on the transport regulations.
Before transporting the GOT, turn the GOT power on and check that the battery voltage status is normal on the Time setting & display screen (utilities screen). In addition, confirm that the adequate battery life remains on the rating plate. Transporting the GOT with the low batt ery voltage or the battery the reache d battery life may unstabilize the backup data unstable during transportation.
Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.
Manual Number
(Model Code)
SH-080544ENG
(1D7M32)
SH-080532ENG
(1D7M26)
SH-080529ENG
(1D7M24)
SH-080530ENG
(1D7M25)

Bundled Items

Product Name Model Name Specifications
GT1155-QTBD 5.7" diagonal [320 × 240 dots], TFT color LCD (256 colors), built-in battery and backlight
GOT
Mounting brackets 4 Dust-/Water-proof packing 1
Mounting screws: M4 x 35mm (1.38") 4 GT11 General Description (This manual) 1

1. Features

1) Improved monitoring performance and connectivity to FA devices
- Multiple la nguages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts.
- Two types of display modes are provided: 256-color display and monoch rome display. In the monochrome display, 16 scales are used to improve the display.
- High-speed mo nitoring through high-speed serial communication at maximum tare of 115.2 kbps or through bus connection with the PLC.
- High spe ed display and high speed touch switch response.
2) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works
- The 3MB use r memory is included as standard.
- CF card interface i s included as standard.
- The USB con nector is positioned on the GOT front. This enables the system startup to be performed more efficiently using FA device setup tool, and eliminates the indirect works (opening and closing the control panel, cable replacement, cable rewiring) in order to improve the working efficiency.
3) Enhanced support of FA setup tools
- PLC program transfer and monitoring are possible via the personal computer that is connected to the GOT if connected directly to the A, QnA, Q, or FX series of the PLC CPU (FA transparent function).
GT1155-QSBD 5.7" diagonal [320 × 240 dots], STN color LCD (256 colors), built-in battery and backlight
GT1150-QLBD 5.7" diagonal [320 × 240 dots], STN monochrome LCD (black/white, 16 sc ales), built-in battery and backlight
Bundled item Quantity Bundled item Quantity

2. Part Name

2.1 Front Panel

GRAPHIC OPERATION TERMINAL
1) 2)
5)
MITSUBISHI
3) 4)
No Name Specifications
Displays the utility screen and the user creation screen.
1) Display screen
2) Touch key
3) USB interface
USB environmental
4) protection cover
5) POWER LED
For the PC connection, refer to the following.
GT Designer2 Version Basic Operation/Data Transfer Manual
GT1155-QTBD:320×240 dots, TFT color liquid crystal GT1155-QSBD:320×240 dots, STN color liquid crystal GT1150-QLBD:320×240 dots, STN monochrome
For operating the touch switches in the utility screen and the user creation screen
USB interface for connecting a personal computer (OS installation, project data download, transparent)
(white/black) liquid crystal, 16 scales
Opens/Closes when the UBS interface is used.
Lit in green : Power is correctly supplied Lit in orange : Screen saving Blinking in orange/green : Blown backlight bulb Not lit : Power is not supplied

2.2 Back Panel

7)
5)4)
12)
2)
3)
GOT
1000
1)
RS-232
RS-422
INPUT 24V DC
+-
(FG)
3)
Power supply terminal layout
INPUT 24V DC
+-
(FG)
6)
ACCESS
OFF ON
CF CARD
BATTERY
I/F
8)9)10)11)
Battery cover opened
14)
No. Name Specifications
1)
2)
3)
4)
5)
6)
RS-232 interface
RS-422 interface
Hole for unit installation fitting
Rating plate (nameplate)
CF card access LED
CF card access switch
For communicating with controller (PLC, microcomputer board, bar code reader, RFID, etc) or personal computer (OS installation, project data download, transparent) (D­sub 9-pin male)
For communicating with controller (PLC, microcomputer board, etc) (D-sub 9-pin female)
Hole for the inserting installation fittings (accessory) during the GOT installation to the panel (4 holes at top and bottom)
--
Lit: CF card accessed Not lit: CF card not accessed
Switch for prohibiting access to CF card before removing the CF card from the GOT ON: CF card being accessed (CF card removal prohibited) OFF:No access to CF card (CF card removal possible)
7) CF card cover Open or close when inserting or removing the CF card.
8) Reset switch Hardware reset switch (Use an isolated rod to operate.)
9) Battery cover Open or close when replacing the battery.
10) Power terminal
Power terminal
11) cover
CF card
12) interface
CF card eject
13) button
14) Battery
For the connection to the controller (PLC, microcomputer board, bar code reader, RFID, etc) or PC, refer to the following.
Power terminal and FG terminal (for power supply (24VDC) to GOT and grounding)
Open or close when connecting a power terminal. (Color: transparent)
Interface for installing the CF card to GOT
Button for removing the CF card
GT11-50BAT battery for storing clock data, alarm history and recipe data (The project data is stored in the built-in flash memory.)
GOT 1000 Series Connection Manual
3)
CF
RESEET
3)
CARD
CF card cover opened
13)

3.1 General Specifications

Item Specifications
Operating ambient temperature
Display section 0 to 50°C
Other than display section 0 to 55°C (When mounted horizontaly), 0 to 50°C (When mounted verticaly)
Storage ambient temperature -20 to 60°C
Operating ambient humidity 10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39°C WBT.)
Storage ambient humidity 10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39°C WBT.)
Frequency Acceleration Half-amplitude Sweep Count
5 to 9Hz -- 3.5mm
9 to 150Hz 9.8m/s
2
5 to 9Hz -- 1.75mm
9 to 150Hz 4.9m/s
2
, 3 times each in X, Y and Z directions)
2
--
--
10 times each in X,
Y and Z directions
Vibration resistance
Shock resistance
Operating atmosphere
Operating altitude
*1
Conforms to JIS B3502 and IEC61131-2
Under intermittent vibration
Under continuous vibration
Conforms to JIS B3502, IEC 61131-2 (147 m/s
Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electroconductive dust particles and must be no direct sunlight. (Same as for saving)
2000 m (6562 ft) max.
Installation location Inside control panel
Overvoltage category
Pollution degree
*3
*2
ΙΙ or less
2 or less
Cooling method Self-cooling
*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to obs erve this instruction may cause a malfunction.
*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution ne twork and the
machinery within the premises. Category ΙΙ applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
*3 This index indicates the degree to which conductive material is ge nerated in the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.

3.2 Performance Specifications

Item
GT1155-QTBD GT1155-QSBD GT1150-QLBD
Type TFT color liquid crystal STN color liquid crystal
Screen size 5.7"
Resolution 320 × 240 dots
Display size W115(4.53) × H86(3.39)[mm](inch) (Horizontal format)
Display character 16-dot standard font: 20 characters × 15 lines, 12-dot standard font: 26 characters × 20 lines
Display
Display color 256 colors Monochrome (white/black), 16 scales
*1
section
Display angle
Left/Right: 70 degrees, Top: 70 degrees, Bottom: 50 degrees (Horizontal format)
Left/Right: 55 degrees, Top: 65 degrees, Bottom: 70 degrees (Horizontal format)
Contrast adjustment -- 16-level adjustment
Intensity of LCD only 400[cd/m
2
](Adjustable in 8 levels) 380[cd/m2](Adjustable in 8 levels) 220[cd/m2](Adjustable in 8 levels)
Intensity adjustment 8-level adjustment
Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25°C)
Cold cathode fluorescent tube (irreplaceable by a user) backlight shutoff detection function is included. Backlight off/screen saving time can be set.
Approx. 75,000h or longer (Time for display intensity reaches 50% at the operating ambient temperature of 25°C)
Backlight
Life
Life
*2
Number of touch keys 300 keys/screen (Matrix structure of 15 lines × 20 columns)
Key size Minimum 16 × 16 dots (per key)
Touch
Number of points touched
panel
simultaneously
Maximum of 2 points
Life 1 million times or more (operating force 0.98N max.)
Memory
*3
C drive
Life (Number of write times)
Flash memory (Internal), for storing project data (3Mbytes) and OS
100,000 times
D drive SRAM (Internal), 512kbyes (battery backup)
Specifications
STN monochrome (white/black) liquid crystal
Left/Right: 45 degrees, Top: 20 degrees, Bottom: 40 degrees (Horizontal format)
Approx. 54,000h or lon ger (Time for display intensity reaches 50% at the operating ambient temperature of 25°C)

3. Specifications

Loading...
+ 4 hidden pages