JY997D14801L
Side
B
Side
JAPANESE
A
Side
ENGLISH
B
FX3U-4AD-TC-ADP
USER'S MANUAL
Manual Number JY997D14801
Revision L
Date June 2017
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective June 2017
Specifications are subject to change without notice.
Safety Precautions
This manual classifies the safety precautions into two categories:
Depending on the circumstances, procedures indicated by may
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
and .
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Manual name Manual No. Description
3S/FX3G/FX3GC/FX3U/
FX
FX
3UC Series
User's Manual
- Analog Control Edition
FX
3S/FX3G/FX3GC/FX3U/
FX
3UC Series
Programming Manual
- Basic & Ap plied Instr uction
Edition
FX
3S Series
User’s Manual
- Hardware Edi tion
FX
3G Series
User’s Manual
- Hardware Edi tion
FX
3GC Series
User’s Manual
- Hardware Edi tion
FX
3U Series
User’s Manual
- Hardware Edi tion
FX
3UC Series
User’s Manual
- Hardware Edi tion
© 2005 Mitsubishi Electric Corporation
(Read these precautions before use.)
JY997D16701
MODEL CODE:
09R619
JY997D16601
MODEL CODE:
09R517
JY997D48601
MODEL CODE:
09R535
JY997D31301
MODEL CODE:
09R521
JY997D45401
MODEL CODE:
09R533
JY997D16501
MODEL CODE:
09R516
JY997D28701
MODEL CODE:
09R519
Describes specifications for
analog control and
programming method for
FX
3S/FX3G/FX3GC/ FX3U/
FX
3UC Series PLC.
Describes PLC programming
for basic/applied instructions
and devices.
Explains FX
specifications for I/O, wiring,
installation, and maintenance.
Explains FX
specifications for I/O, wiring,
installation, and maintenance.
Explains FX
specifications for I/O, wiring,
installation, and maintenance.
Explains FX
specifications for I/O, wiring,
installation, and maintenance.
Explains FX
specifications for I/O, wiring,
installation, and maintenance.
3GC Series PLC
3UC Series PLC
3S Serie s PLC
3G Series PLC
3U Series PLC
Applicable standards
FX3U-4AD-TC-ADP units made in June, 2005 or later comply with the EC Directive
(EMC Directive) and UL standards (UL, cUL). Further information can be found in the
following manual.
→ FX
Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Attention
This product is designed for use in industrial applications.
Caution for EC Directive
The analog special adapters have been found to be compliant to the European
standards in the aforesaid manual and directive. However, for the very best performance from what are in fact delicate measuring and controlled output device
Mitsubishi Electric would like to make the following points;
As analog devices are sensitive by nature, their use should be considered carefully. For users of proprietary cables (integral with sensors or actuators), these
users should follow those manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used. If NO other
EMC protection is provided, then users may experience temporary loss or
accuracy between ±10 % in very heavy industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC precautions are followed for the users complete control system, users should expect accuracy as
specified in this manual.
• Sensitive analog cable should not be laid in the same trunking or cable
• Good cable shielding should be used. When terminating the shield at Earth
• When reading analog values, EMC accuracy can be improved out by
1. Outline
FX3U-4AD-TC-ADP (hereinafter called TC-ADP) is an analog special adapter for
measuring temperature via four channels of connected Type K or Type J thermocouple
thermometer.
→ FX
3S Series Hardware Manual (Manual No. JY997D48301)
→ FX
3G Series Hardware Manual (Manual No. JY997D46001)
→ FX
3GC Series Hardware Manual (Manual No. JY997D45201)
3U Series Hardware Manual (Manual No. JY997D50301)
→ FX
3UC (D, DS, DSS) Series Hardware Manual (Manual No. JY997D50501)
→ FX
3UC-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)
conduit as high voltage cabling. Where possible users should run analog
cables separately.
- ensure that no earth loops are accidentally created.
averaging the readings. This can be achieved either through functions on the
analog special adapters or through a users program.
1.1 Incorporated Items
Verify that the following product and items are included in the package:
FX
Product
Accessories User’s manual (This manual)
1.2 External Dimensions, Part Names, and Terminal Layout
[2]
[1]
[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock:
Used to connect additional spe cial adapters onto the left side of this sp ecial
adapter.
[4] Special adapters connector cover:
Remove this cover to connect additional special adapters to the left side.
3U-4AD-TC-ADP K/J type thermocouple thermometer input
special adapter
[3]
[5]
[4]
[6]
[7]
[8]
7(0.28")
Special adapter
connector cover
is removed
74(2.92")
[11]
(0.62")
15.1
15.5
(0.6")
17.6
(0.7")
Weight: Approx. 0.1 kg (0.22 lbs)
[9]
[10]
90(3.55")
98(3.86")
106(4.18")
(mounting hole pitch)
24+
24-
J-type
J-type
L1+
L1-
L2+
L2-
L3+
L3-
L4+
L4-
[5] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)
Not used when connecting to FX
[6] POWER LED (green):
Lit while 24 V DC power is supplied properly to terminals '24+' and '24-'.
[7] Terminal block (European type):
Connect thermocouple sensor input, Type K or J changeover input, and 24 V DC
power supply.
[8] Special adapter connector:
Used to connect this special adapter to PLC main unit or special adapter.
[9] DIN rail mounting hook
[10] Special adapter fixing hook
[11] Special adapter connec tor:
Used to connect communication or analog special adapters to the left side of the
TC-ADP.
2. Installation
For installation/uninstallation details, refer to the respective PLC User's manual
Hardware Edition.
INSTALLATION
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
• Use the product within the generic environment specifications described in PLC
main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl
or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
• When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
• Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.
2.1 Connection to the PLC
This section describes the connection method to the PLC (FX3U Series PLC is used for
the following example).
For installation method to other PLCs, refer to the respective PLC User's manual
Hardware Edition.
Procedure
1) Turn off the power.
Disconnect all the cables connected to the PLC main unit and special adapter, and
demount the main unit and special adapter mounted on DIN rail or mounted directly
using screws.
2) Install an expansion board to the main unit.
For the expansion board installation procedure, refer to the following manual:
3) Remove the specia l adapter connector cover on
the expansion board (fig.A).
When connecting this product to another special
adapter, please replace the 'expansion board' in
the above description wit h a 'special adapter' and
perform the procedure as i ndicated.
4)
Slide the special adap ter slide lock
(fig.B) of the main unit.
When connecting this product to another special
adapter, please replace the 'main unit' in the
above description with a 'special adapter' and
perform the procedure as indi cated. (Please
replace the following pr ocedures similarly.)
3GC/FX3UC Serie s PLC.
2, H2S, SO2 or NO2), flammable gas, vibration or impacts,
→ FX
3U Series User's Manual - Hardware Edition
-48MR/ES
3U
-48M
3U
FX
4)
3)
B
FX
RUN
STOP
A
4)
B
5)
Connect the
special adapter
(fig.C) to the
main unit as
shown on the
right
.
6) Slide back the
special adapter
slide lock (fig.B)
of the main unit
to fix the special
adapter (fig.C).
C
B
FX
3U
***
***
POWER
6)
3U
FX
RUN
STOP
5)
5)
5)
Connection precautions
Connect all the hi gh-speed I/O spe cial adapters bef ore connecting other
special adapters when they are used in combination.
Do not connect a high-speed I/O special adapter on the left side of any
special adapters other tha n other high-speed I/O special adapters.
3. Wiring
WIRING
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING
PRECAUTIONS
• When drilling screw holes or wiring, make sure cutting or wire d ebris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Make sure to observe the following precautions in order to prevent
malfunctions under the influence of noise:
1) Do not bundle the power line or shield of the analog input/output cable
together with or lay it cl ose to the m ain circuit, hi gh-voltage line, or load
line.
Otherwise, noise disturbance and/or surge induction are likely to take
place. As a guideline, lay the control line at least 100 mm (3.94") or more
away from the main circuit, high-voltage line, or load line.
2) Ground the shield of the analog input/output cabl e at one point on the
signal receiving side. However, do not use common grounding with heavy
electrical systems.
• Make sure to properly wire to the terminal block (European type) in
accordance with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.
- The disposal size of the cable end should follow the dimens ions
described in the manual.
- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of w ires or electric wires
of unspecified size.
- Affix the electric wires so that nei ther the terminal block nor the connected
parts are directly stressed.
3.1 Applicable cable and terminal tightening torque
3.1.1 Type terminal block (European type)
1) Wire size
- The po wer supply wiring and the Type K/J changeover input wiring should
use 22-20 AWG wire.
- Ther mocouple wiring should use the compensating lead wire suitable for
the type of thermocouple.
2) Applicable cable
→ For details of compensating lead wire, Refer to Section 3.3
Typ e Wire size
Single-wire
2-wire
2
to 0.5 mm2 (AWG22 to 20)
0.3 mm
2 pieces of 0.3 mm
2
(AWG22)
-48M
3U
FX
-48MR/ES
3U
-48M
FX
6)
B

3) Ter mination of cable end
Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
An alternative connection is to use a ferrule with insulating sleeve.
<Reference>
Manufacturer Model Caulking to ol
Phoenix Contact Co., Ltd. AI 0.5-8WH
*1 Old model name: CRIMPFOX ZA 3
*2 Old model name: CRIMPFOX UD 6
- Strand wire/single wire
9 mm
(0.35")
- Ferrule with insulation sleeve
Insulation sleeve
2.6 mm (0.1")
When using a ferrule with insulation sleeve, choose a wire with proper cable
sheath referring to the above outside dimensions, or otherwise, the wire
cannot be inserted easily. The tightening torque must be 0.22 to 0.25 N
not tighten terminal screws with a torque outside the above-mentioned range.
Failure to do so may cause equipment failures or malfunctions.
3.2 Power Supply Wiring
For the power supply wiring, refer to the following manual.
3S/FX3G/FX3GC/FX3U/FX3UC Series User’s Manual - Analog Control
→ FX
3.3 Selection of thermocouple
Precautions on thermocouple wiring
• Thermocouple type
- There are 2 types of thermocouples: Type K and Type J. Select the desired
type. However, be sure to connect the same type of thermocouple to all the
channels.
- Use insulated thermocouple types.
• Compensating lead
wire To connect the
thermocouple, use
one of the right
of compensating l
wires.
The compensating
lead wire indicates the temperature value of approximately 0.12 °C higher than
that of the wire resistor (10 Ω). Temperature value should be used in
consideration of this point.
If the compensating lead wire is very long, the wire may be easily affected by
noise, etc. It is , therefore, r ecommended th at the length of the compensati ng
lead wire should be 100 m (328' 1") or less.
Example of thermocouple wiring
→ For the terminal configuration, refer to Section 1.2
Thermocouple
Type K KX, KCA, KCB, KCC
types
ead
Type J JX
Using Type J
Type of compensating lead wire
Terminal
block
*1
Thermocouple Wiring
Compensating lead
Thermocouple
(Ground resistance: 100 Ω or less)
L +, L -, ch : represents the channel number.
*1 When using the Type J thermocouple, short-circuit the 'Type J' terminals
and turn the special auxiliary relay (Type K/J mode changeover) ON.
For details of auxiliary relays, refer to the following manual.
3S/FX3G/FX3GC/FX3U/FX 3UC Series User's Manual - Analog Control
→ FX
*2 24 V DC service power supply of the FX
be used.
wire (Shielded)
External power
supply wiring
24 V DC
*2
Grounding
3S/FX3G/FX3U Series PLC can also
(or CRIMPFOX 6T-F*2)
14 mm (0.55")
J-type
J-type
compensation circui t
L +
L -
L +
L -
24+
24-
CRIMPFOX 6
compensation circui t
Contact area
(Crimp area)
TC-ADP
Temperature
3 kΩ
Temperature
3 kΩ
*1
8 mm
(0.31")
Edition
ch
ch
Edition
3.4 Grounding
Grounding should be performed as stated below.
• The grounding resistance should be 100 Ω or less.
• Independent grounding should be performed for best results.
When independent g rounding is not perfo rmed, perform "sh ared grounding" of th e
following figure.
For details, refer to the respective PLC User's manual Hardware Edition.
Other
PLC
equipment
Independent grounding
(Best condition)
• The grounding wire size should be AWG 22-20 (0.3-0.5 mm
• The grounding point should be close to the PLC, and all grounding wire should be
as short as possible.
Other
PLC
equipment
Shared grounding
(Good condition)
4. Specifications
STARTUP AND
MAINTENANCE
PRECAUTIONS
•
m. Do
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
* For repair, contact your local Mitsubishi Electric representative.
• Do not drop the product or exert strong impact to it.
Doing so may cause damage.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORTATION AND
STORAGE PRECAUTIONS
• The product is a precision instrument. During transportation, avoid impacts larger
than those spe cified in the ge neral specific ations by usin g dedicated pac kaging
boxes and shock-absorbing palettes.
Failure to do so may cause failures in the product.
After transportatio n, verify operat ion of the produ ct and check for damage of the
mounting part, etc.
4.1 Applicable PLC
Model name Applicability
FX
3S Series PLC Ver. 1.00 or later (from first production)
3G Series PLC Ver. 1.00 or later (from first production)
FX
FX
3GC Series PLC Ver. 1.40 or later (from first production)
FX
3U Series PLC Ver. 2.20 or later (from first production)
3UC Series PLC
FX
The version number can be checked by monitoring D8001/D8101 as the last three
digits indicate it.
4.2 General Specifications
Items other than the following are equivalent to the those of the PLC main unit.
For general specifications, refer to the respective PLC User's manual Hardware
Edition.
Dielectric withstand
voltage
+5 V
Insulation resistance
4.3 Power Supply Specifications
A/D conversion
circuit driving power
Interface driving
power
Ver. 1.30 or later (from the productio n manufactured in Aug ust,
2004 with SER No. 48****)
Item Specification
500 V AC for one minute
5 MΩ or higher by 500 V DC
insulation resistance tester
Item Specification
24 V DC +20 %/-15 %, 45 mA for 24 V DC
Connect a 24 V D C power suppl y to the term inal block.
5 V DC, 15 mA
5 V DC power is supplied from the internal power supply of
main unit.
Other
PLC
equipment
Common grounding
(Not allowed)
2
).
Between all terminals and
ground termin al of PLC
main unit
4.4 Performance Specifications
Item
Centigrade (°C) Fahrenheit (°F)
Input signal
Rated
temperature
range
Digital output
Resolution
Type K
-100 °C to +1000 °C
Type J -100 °C to +600 °C Type J -148 °F to +1112 °F
Type K -1000 to +10000 Type K -1480 to +18320
Type J -1000 to +6000 Type J -1480 to +11120
Type K 0.4 °C Type K 0.72 °F
Type J 0.3 °CType J0.54 °F
Total accuracy ±(0.5 % full scale +1 °C)
• FX
3U/FX3UC Series PLC: 200 µs
A/D conversion
time
Input
characteristics
Insulation
method
Occupied
points
(The data will be updated at every scan time of the PLC.)
• FX
3S/FX3G/FX3GC Series PLC: 250 µs
(The data will be updated at every scan time of the PLC.)
Type K
+10100
+10000
-100°C
0
-1000
-110°C
-1100
Type J
+6100
+6000
-100°C
0
-1000
-110°C
-1100
• The photocoupler is adopted to insulate the analog input a rea
from the PLC.
• The DC/DC converter is adopted to insulate the power supply
line from the analog input area.
• A channels are not insulated from each other.
0 point (This number is not related to the maximum number of
input/output points of the PLC.)
Specifications
Thermocouple type K or J
JIS C 1602-1995
Type K -148 °F to +1832 °F
Type K
+18500
+18320
+1010°C
-148°F
°
C
+1000
+600°C
F
°
-166
Type J
+11300
+11120
+610°C
-148°F
F
°
-166
0
+1832
-1480
-1660
0
+1112
-1480
-1660
「电器电子产品有害物质限制使用标识要求」的表示方式
Note: This symbol mark is for China only.
含有有害6物质的名称,含有量,含有部品
本产品中所含有的有害 6 物质的名称,含有量,含有部品如下表所示。
产品中有害物质的名称及含量
有害物质
可编程
控制器
部件名称
外壳
印刷基板
铅
(Pb)汞(Hg)镉(Cd)
○○
○○ ○ ○ ○
×
六价铬
多溴联苯
(Cr(VI))
(PBB)
○○ ○ ○
二苯醚
(PBDE)
本表格依据SJ/T 11364的规定编制。
○
:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规定
的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T
26572规定的限量要求。
多溴
F
°
+1850
°
F
F
°
+1130
°
F
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the grat is warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2)
Loss in opport unity, lost profits inc urred to the user by Failures of Mitsubishi products.
(3)
Special damages and secondary damages w hether foreseeable or not, compensa tion for
accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
•
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
•
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
•
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN