Mitsubishi Electric FX3U-3A-ADP User Manual

JY997D35601F
FX
3U
-48MR/ES
FX
3U
-48MR/ES
FX
3U
-48M
0
11
Side
B
Side
JAPANESE
A
Side
ENGLISH
B
FX3U-3A-ADP
USER'S MANUAL
Manual Number JY997D35601
Revision F
Date January 2017
This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions. Store this manual in a safe place so that it can be taken out and read whenever necessary. Always forward it to the end user. Registration: The company and product names described in this manual are registered trademarks or the trademarks of their respective companies.
Effective January 2017 Specifications are subject to change without notice.

Safety Precautions

This manual classifies the safety precautions into two categories:
Depending on the circumstances, procedures indicated by may also cause severe injury. It is important to follow all precautions for personal safety.

Associated Manuals

How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer from who you purchased your product.
and .
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Manual name Manual No. Description
3S/FX3G/FX3GC/FX3U/
FX FX
3UC Series
User's Manual
- Analog Control Edition
FX
3S/FX3G/FX3GC/FX3U/
FX
3UC Series
Programming Manual
- Basic & Applied Instruction Edition
FX
3S Series
User’s Manual
- Hardware Edi tion
FX
3G Series
User’s Manual
- Hardware Edi tion
FX
3GC Series
User’s Manual
- Hardware Edi tion
FX
3U Series
User’s Manual
- Hardware Edi tion
FX
3UC Series
User’s Manual
- Hardware Edi tion
© 2009 Mitsubishi Electric Corporation
(Read these precautions before use.)
Describes specifications for
JY997D16701
MODEL CODE:
09R619
JY997D16601
MODEL CODE:
09R517
JY997D48601
MODEL CODE:
09R535
JY997D31301
MODEL CODE:
09R521
JY997D45401
MODEL CODE:
09R533
JY997D16501
MODEL CODE:
09R516
JY997D28701
MODEL CODE:
09R519
analog control and programming method for FX
3S/FX3G/FX3GC/FX3U/
FX
3UC Series PLC.
Describes PLC programming for basic/applied instructions and devices.
Explains FX3S Series PLC specifications for I/O, wiring, installation, and maintenance.
Explains FX specifications for I/O, wiring, installation, and maintenance.
Explains FX specifications for I/O, wiring, installation, and maintenance.
Explains FX specifications for I/O, wiring, installation, and maintenance.
Explains FX specifications for I/O, wiring, installation, and maintenance.
3G Series PLC
3GC Series PLC
3U Series PLC
3UC Series PLC

Applicable standards

FX3U-3A-ADP units made in June, 2009 or later comply with the EC Directive (EMC
Directive) and UL standards (UL, cUL). Further i nformation can be found in the following manual.
FX
Regarding the standards that relate to the main unit, please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider.
Attention
This product is designed for use in industrial applications.
Caution for compliance with EC Directive
The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive. However, for the very best performance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points; As analog devices are sensitive by natur e, their use should be considered carefully. For users of proprietary cables (integral with sensors or actuators), these users should follow those manufacturers installation requirements. Mitsubishi Electric recommend that shielded cables should be used. If NO other EMC protection i s provided, then users may exper ience temporary los s or accuracy between ±10 % in very heavy industrial areas. However, Mitsubishi Electric suggest that if adequate EMC precautions are followed for the users complete control system, users should expect accuracy as specified in this manual.
Sensitive analog cable should not be laid in the same trunking or cable
Good cable shielding should be used. When terminating the shield at Earth
When reading analog values, EMC accuracy can be improved out by

1. Outline

The FX3U-3A-ADP special adapter for analog input and output (hereinafter called 3A-ADP) is a special adapter that adds to add two analog input points and one analog output point.

1.1 Incorporated Items

Verify that the following product and items are included in the package:
FX
3S Series Hardware Manual (Manual No. JY997D48301)
FX
3G Series Hardware Manual (Manual No. JY997D46001)
FX
3GC Series Hardware Manual (Manual No. JY997D45201)
FX
3UC (D, DS, DSS) Series Hardware Manual (Manual No. JY997D50501)
conduit as high voltage cabling. Where possible users should run analog cables separately.
3U Series Hardware Manual (Manual No. JY997D50301)
FX
3UC-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)
- ensure that no earth loops are accidentally created.
averaging the readings. This can be achieved either through functions on the analog special adapters or through a users program.
Product FX3U-3A-ADP analog input and output special adapter
Accessories User’s Manual (This manual)

1.2 External Dimensions, Part Names, and Terminal Layout

[3]
[5]
[4]
[10]
[6]
[2]
[1]
[7]
[8]
90(3.55")
7(0.28")
74(2.92")
Special adapter connector cover is removed
[1] DIN rail mounting groove (DIN rail: DIN46277) [2] Name plate [3] Special adapter slide lock:
Used to connect a dditional special a dapters onto the left side of this special adapter.
[4] Special adapter connector cover:
Remove this cover to connect additional special adapters to the left side.
[11]
15.1
15.5 (0.6")
(0.62")
17.6
(0.7")
Weight: Approx. 0.1 kg (0.22 lbs)
[9]
24+
24-
V1+
I1+
COM1
V2+
I2+
98(3.86")
106(4.18")
COM2
(mounting hole pitch)
VO
IO
COM
[5] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)
Not used when connecting to FX
[6] POWER LED (green):
Lit while 24 V DC power is supplied properly to terminals '24+' and '24-'.
[7] Terminal block (European type):
Connect the analog voltage/current signal, and 24 V DC power supply.
[8] Special adapter connector:
Used to connect this special adapter to PLC main unit or special adapter. [9] DIN rail mounting hook [10] Special adapter fixing hook [11] Special adapter connector:
Used to connect communication or analog special adapters to the left side of the
3AD-ADP.

2. Installation

For installation/uninstallation details, refer to the respective PLC User's manual Hardware Edition.
INSTALLATION PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting installation or wiring work. Failure to do so may cause electric shock or damage to the product.
INSTALLATION PRECAUTIONS
Use the product within the generic environment specifications described in PLC main unit manual (Hardware Edition). Never use the product in areas with excessive dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl impacts, or expose it to high temperature, condensation, or rain and wind. If the product is used in such conditions, electric shock, fire, malfunctions, deterioration or damage may occur.
When drilling screw holes or wiring, make sure cutting or wire debris does not enter the ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.
Do not touch the conductive parts of the product directly. Doing so may cause device failures or malfunctions.
Connect special adapter securely to their designated connectors. Loose connections may cause malfunctions.

2.1 Connection to the PLC

This section describes the connection method to the PLC (FX3U Series PLC is used for the following example). For installation method to other PLCs, refer to the respective PLC User's manual Hardware Edition.
Procedure
1) Turn off the power. Disconnect all the cables connected to the PLC main unit and special adapter, and demount the main unit and special adapter mounted on DIN rail or mounted directly using screws.
2) Install an expansion board to the main unit. For the expansion board installation procedure, refer to the following manual:
3) Remove the special adapter connector cover on the expansion board (fig.A). When connecting this product to another special adapter, please replace the 'expansion board' in the above description with a 'special adapter' and perform the procedure as indicated.
4) Slide the speci al adapter slide lock (fig.B) of the main unit. When connecting this product to another special adapter, please replace the 'main unit' in the above description with a 'special adapter' and perform the procedure as indicated. (Please replace the following procedures similarly.)
3GC/FX3UC Serie s PLC.
2, H2 S, SO2, or NO2), flammable gas, vibration or
FX
3U Series User's Manual - Hardware Edition
-48MR/ES
3U
-48M
3U
FX
4)
3)
B
FX
RUN
STOP
4)
A
B
5) Connect the special adapter (fig.C) to the main unit as shown on the right.
6) Slide back the special adapter slide lock (fig.B) of the main unit to fix the special adapter (fig.C).
C
B
FX
3U
­***
­***
POWER
6)
-48M
3U
FX
RUN
STOP
5)
5)
5)
Connection precautions
Connect all the hi gh-speed I/O spe cial adapters be fore connectin g other special adapters when they are used in combination.
Do not connect a high-speed I/O special adapter on the left side of any special adapters other than other high-speed I/O special adapters.

3. Wiring

WIRING PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting installation or wiring work. Failure to do so may cause electric shock or damage to the product.
WIRING PRECAUTIONS
When drilling screw holes or wiring, make sure cutting or wire d ebris does not enter the ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.
Make sure to observe the following precautions in order to prevent any damage to the mac hinery or acci dents due to abnor mal data writt en to the PLC under the influence of noise:
1) Do not bundle the power line or shield of the analog input/output cable together with or lay it cl ose to the m ain circuit, hi gh-voltage line, or load line. Otherwise, noise disturbance and/or surge induction are likely to take place. As a guideline, lay the control line at l east 100mm (3.94") or more away from the main circuit, high-voltage line, or load line.
2) Ground the shield of the analog input/output cabl e at one point on the signal receiving side. However, do not use common grounding with heavy electrical systems.
Make sure to properly wire to the terminal block (European type) in accordance with the following precautions. Failure to do so may cause electric shock, equipment failures, a short-circuit, wire breakage, malfunctions, or damage to the product.
- The disposal size of the cable end should follow the dimens ions described in the manual.
- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of w ires or electric wires of unspecified size.
- Affix the electric wires so that nei ther the terminal block nor the connected parts are directly stressed.
Make sure to properly wire the terminal block in accordance with the following precautions. Failure to do so may cause electric shock, equipment failures, a short-circuit, wire breakage, malfunctions, or damage to the product.
- The disposal size of the cable end should follow the dimens ions described in the manual of the PLC main unit.
- Tightening torque should follow the specifications in the manual of the PLC main un it.
10
IN
-48M
-48MR/ES
6)
B
FX
3U
-48MR/ES
FX
3U
-48MR/ES
FX
3U
-48M
0
11

3.1 Applicable Cable and Terminal Tightening Torque

A

3.1.1 Terminal block (European type)

1) Wire size Wiring to analog device should use 22-20 AWG wire.
2) Applicable cable
3) Ter mination of cable end

3.2 Power Supply Wiring

For the power supply wiring, refer to the following manual.

3.3 Wiring of Analog Input

*1 Use 2-core shielded twisted pair cable for the analog input lines, and
*2 Make sure to short-circuit the 'V+' and 'I+' terminals when current is
*3 24 V DC service power supply of the FX
Typ e Wire size
Single-wire
2-wire
Strip the coating of strand wire and twist the cable core before connecting it, or strip the coating of single wire before connecting it. An alternative connection is to use a ferrule with insulating sleeve. <Reference>
2
to 0.5 mm2 (AWG22 to 20)
0.3 mm
2 pieces of 0.3 mm
2
(AWG22)
Manufacturer Model Caulking tool
Phoenix Contact Co., Ltd. AI 0.5-8WH
CRIMPFOX 6
(or CRIMPFOX 6T-F*2)
*1
*1 Old model name: CRIMPFOX ZA 3
*2 Old model name: CRIMPFOX UD 6
- Strand wire/single wire
9mm
(0.35")
When using a stick terminal with insulating sleeve, choose a wire with proper cable sheath referring to the above outside dimensions, or otherwise, the wire cannot be inserted easily. The tightening torque must be 0.22 to 0.25 N screws with a torque outside the above-mentioned range. Failure to do so may cause equipment failures or malfunctions.
FX
3S/FX3G/FX3GC/FX3U/FX3UC Series User’s Manual - Analog Control
- Stick terminal with insulating sleeve
Insulation sleeve
2.6mm(0.1")
Contact area (Crimp area)
14mm(0.55")
m. Do not tighten terminal
8mm
(0.31")
Edition
For the terminal configuration, refer to Section 1.2
Using current
input
Using voltage input
External power
supply wiring
V +, I +, ch : represents the channel num ber.
24 V DC
Terminal
*1
*1
*3
Grounding
block
*2
COM
COM
V +
I +
V +
I +
24+
24-
250Ω
250Ω
3A-ADP
110kΩ
88.7kΩ
110kΩ
88.7kΩ
ch
ch
+15V
separate the analog input lines from other power lines or inductive lines.
input. (: input channel number)
be used.
3S/FX3G/FX3U Series PLC can also

3.4 Wiring of Anal og Output

Using voltage
output
Using current
output
*1 Use 2-core shielded twisted pair cable for the analog output lines, and separate
the analog output lines from other power lines or inductive lines.
*2 Ground the shielded wire at one point on the signal receiving side.

3.5 Grounding

Grounding should be performed as stated below.
The grounding resistance should be 100 Ω or less.
Independent grounding should be performed for best results.
When independent g rounding is not perfo rmed, perform "sh ared grounding" of th e following figure. For details, refer to the respective PLC User's manual Hardware Edition.
Independent grounding
Best condition
The grounding wire size should be AWG 22-20 (0.3-0.5 mm
The grounding point should be close to the PLC, and all grounding wire should be
as short as possible.
For the terminal configuration, refer to Section 1.2
*1
*2 Grounding
*1
*2
Other
equipment
Grounding
Terminal
block
Terminal
block
Shared grounding
Good condition
VO IO
COM
VO
IO
COM
equipment
Other
3A-ADP
3A-ADP
PLCPLCPLC
Common grounding
equipment
Not allowed
2
).
Other

4. Specifications

STARTUP AND MAINTENANCE PRECAUTIONS
Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions. * For repair, contact your local Mitsubishi Electric representative.
Do not drop the product or exert strong impact to it. Doing so may cause damage.
DISPOSAL PRECAUTIONS
Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device.
TRANSPORTATION AND STORAGE PRECAUTIONS
The product is a precision instrument. During transportation, avoid impacts larger than those spe cified in the ge neral specific ations by usin g dedicated pac kaging boxes and shock-absorbing palettes. Failure to do so may cause failures in the product. After transportation, verify operatio n of the product and check for d amage of the mounting part, etc.

4.1 Applicable PLC

Model name Applicability
3S Series PLC Ver. 1.00 or later (from first production)
FX
FX
3G Series PLC Ver. 1.20 or later
FX
3GC Series PLC Ver. 1.40 or later (from first production)
FX
3U Series PLC Ver. 2.61 or later
3UC Series PLC Ver. 2.61 or later
FX
The version number can be checked by monitoring D8001/D8101 as the last three digits indicate it.

4.2 General Specifications

Items other than the following are equivalent to the those of the PLC main unit. For general specifications, refer to the respective PLC User's manual Hardware Edition.
Item Specification
Dielectric withstand voltage
Insulation resistance
500 V AC for one minute
5 MΩ or higher by 500 V DC insulation resistance tester
Between all terminals and ground termina l of PLC main unit

4.3 Power Supply Specifications

Item Specification
Conversion circuit driving power
Interface driving power

4.4 Performance Specifications

Performance Specifications of Analog Input
Item
Analog input range
Maximum absolute input
Resolution 2.5 mV (10 V/4000) 5 μA (16 mA/3200)
Total accuracy
Input characteristics
Performance Specifications of Analog Output
Item
Analog output range
Resolution 2.5 mV (10 V/4000) 4 μA (16 mA/4000)
Tota l accuracy
Output characteristics
24 V DC +20 % / -15 %, 90 mA Connect a 24 V DC power supply to the terminal block.
5 V DC, 20 mA 5 V DC power is supplied from the internal power supply of main unit.
Specification
Voltage input Current input
0 to 10 V DC
(Input resistance: 198.7 kΩ)
4 to 20 mA DC
(Input resistance: 250 Ω)
-0.5 V, +15 V -2 mA, +30 mA
•±0.5 % (±50 mV) for full scale of 10 V (when ambient temperature is 25 °C±5 °C)
•±1.0 % (±100 mV) for full scale of 10 V (when ambient temperature is 0 °C to 55 °C)
4080
4000
Digital output
Analog input
10V
0 10.2V
•±0.5 % (±80 μA) for full scale of 16 mA (when ambient temperature is 25 °C±5 °C)
•±1.0 % (±160 μA) for full scale of 16 mA (when ambient temperature is 0 °C to 55 °C)
3280
3200
Digital output
0
4mA
Analog input
Specification
Voltage output Current output
0 to 10 V DC
(External load: 5 kΩ to 1 MΩ)
•±0.5 % (±50 mV) for full scale of 10 V (when ambient temperature is 25 °C±5 °C)
•±1.0 % (±100 mV) for full scale of 10 V (when ambient temperature is 0 °C to 55 °C)
If the external load resistance (Rs) is less than 5 kΩ, the accuracy will be increases as shown in the following formula: (Addition will be 100 mV per %.)
47×100
0.9 %
Rs+47
for full scale of 10 V
10V
Analog output
0
Digital input
4000
4080
4 to 20 mA DC
(External load: 500 Ω or less)
•±0.5 % (±80 μA) for full scale of 16 mA (when ambient temperature is 25 °C±5 °C)
•±1.0 % (±160 μA) for full scale of 16 mA (when ambient temperature is 0 °C to 55 °C)
20mA
Analog output
4mA
0 4080
Digital input
20mA
4000
20.4m
Common Specifications of Analog Input and Output
Item Specification
Digital input and output
Conversion time
Insulation method
Occupied points
12 bits, binary
FX
3U/FX3UC Series PLC: 80 μs for each selected input channel
+ 40 μs for each selected output channel (The data will be updated at every scan time of the PLC.)
FX
3S/FX3G/FX3GC Series PLC: 90 μs for each selected input
channel + 50 μs for each selected output channel (The data will be updated at every scan time of the PLC.)
A photocoupler is employed to insulate the analog input and output area from the PLC.
A DC/DC converter is employed to insulate the power supply line from the analog input and output area.
Channels are not insulated from each other.
0 point (This number is not related to the maximum number of input/output points of the PLC.)

「电器电子产品有害物质限制使用标识要求」的表示方式

Note: This symbol mark is for China only.
含有有害6物质的名称,含有量,含有部品
本产品中所含有的有害 6 物质的名称,含有量,含有部品如下表 所示。
产品中有害物质的名称及含量
有害物质
(PBB)
多溴 二苯醚 (PBDE)
可编程 控制器
部件名称
外壳
印刷基板
(Pb)汞(Hg)镉(Cd)
○○
○○ ○
×
六价铬
多溴联苯
(Cr(VI))
○○ ○ ○
本表格依据SJ/T 11364的规定编制。
:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572
规定的限量要求以下。 ×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572规定的限量要求。
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability Regardless of the grat is warranty term, Mitsubishi shall not be liable for compensation to: (1) Damages caused by any cause found not to be the responsibility of Mitsubishi. (2)
Loss in opport unity, lost profits inc urred to the user by Failures of Mitsubishi products.
Special damages and secondary damages w hether foreseeable or not, compensa tion for accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.
This product has been manufactured under strict quality control. However when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN