•This manual contains t ext, diagrams and explanations which will guide the reader in the corre ct installation
and operation of the FX
attempting to install or use the unit.
•Further inform ation can be found in the FX Series Programming Manual II.
•If in doubt at any stage of the installation of an FX
professional electrical engineer who is qualified and trained to the local and national standards which apply to
the installation site.
•If in doubt about th e operation or use of FX
Mitsubisi Electric distributor.
•This manual is subject to change without notice.
1S
Series Programmable Controllers. It should be read and understood before
Series Programmable Controller always consult a
1S
Series Programmable Controller please consult the nearest
1S
FX1S Series Programmable Controllers
FX
Series Programmable Controllers
1S
Hardware Manual
Manual number :JY992D83901
Manual revision :D
Date:August 2000
i
FX1S Series Programmable Controllers
Guidelines for the Safety of the User and Protection of the FX1S.
This manual provides inform ation for the use o f the FX1S. The manual has been wr itte n to be
used by trained and co mpetent pe rsonnel. The definit ion of su ch a pers on or perso ns is as
follows:
a) Any engineer who is responsible for the planning, design and construction of automatic
equipment using the product associated w ith this manual, shoul d be of a competent
nature, trained and qualified to the local and national standards required to fulfill that
role. These engineers should be fully aware of all aspects of safety with regards to
automated equipment.
b) Any commissioning or service engineer must be of a competent nature, trained and
qualified to the local and national standards required to fulfill that job. These engineers
should also be trained in the use and maintenance of the completed pr oduct. This
includes being completely familiar with all associated documentation for said product. All
maintenance should be carried out in accordance with established safety practices.
c) All operators of the completed equipment should be trained to use that product in a safe
and coordinate d manner i n complia nce to esta blished safety practices. The op erators
should also be familiar with documentation which is connected with the actual operation
of the completed equipment.
Note :
The term ‘completed equipment’ refers to a third party constructed device which
contains or uses the product associated with this manual.
ii
FX1S Series Programmable Controllers
Notes on the Symbols Used in this Manual
At various times through out this manual cer tain symbols will be used to highlight points of
information which are intended to ensure the user’s personal safety and protect the integrity of
equipment. Whenever any of the following symbols are encountered its associat ed note must
be read and understood. Each of the symbols used will now be listed with a brief description of
its meaning.
Hardware Warnings
1) Indicates that the identified danger WILL cause physical and property damage.
2) Indicates that the identified danger could POSSIBLY cause physical and proper ty
damage.
3) Indicates a point of further interest or further explanation.
Software Warnings
4) Indicates special care must be taken when using this element of software.
5) Indicates a special point which the us er of the associate software element should
be aware.
6) Indicates a point of interest or further explanation.
iii
FX1S Series Programmable Controllers
•Under no circumstances will Mitsubishi Electric be liable for any consequential damage that
may arise as a result of the installation or use of this equipment.
•All examples and diagrams shown in this manual are intended only as an aid to
understanding the text, not to guarantee operation. Mitsubishi Electric will accept no
responsibility for actual use of the product based on these illustrative examples.
•Owing to the very great variety in possible application of this equipment, you must satisfy
yourself as to its suitability for your specific application.
This manual covers the hardware installation instructions for the FX1S Series Programmable
Logic Controller.
Table 1.1: AC Power, Relay Output Units
MODEL
FX1S-10MR-ES/UL6
FX1S-14MR-ES/UL86
FX1S-20MR-ES/UL128
FX1S-30MR-ES/UL1614
Table 1.2:
FX1S-10MR- DS6
FX1S-14MR-DS86
FX1S-20MR-DS128
FX1S-30MR- DS1614
DC Power, Relay Output Units
MODEL
INPUTOUTPUT
QTYTYPEQTYTYPE
24V DC
Sink /
Source
INPUTOUTPUT
QTYTYPEQTYTYPE
24V DC
Sink /
Source
POWER
SUPPLY
4
Relay
4
Relay
85 - 264
VAC
POWER
SUPPLY
24 VDC
+10, -15%
DIMENSIONS
mm (inches)
60
(2.4)
75
(3.0)
100
(3.9)
60
(2.4)
75
(3.0)
100
(3.9)
90
(3.5)75(3.0)
DIMENSIONS
mm (inches)
90
(3.5)49(1.9)
MASS (WEIGHT)
kg (lbs)
0.30
(0.66)
0.40
(0.88)
0.45
(0.99)
MASS (WEIGHT)
kg (lbs)
0.22
(0.48)
0.30
(0.66)
0.35
(0.77)
1-1
FX1S Series Programmable ControllerIntroduction 1
Table 1.3: DC Power Transistor Output Units
INPUTOUTPUT
MODEL
FX1S-10MT-DSS6
FX1S-14MT-DSS86
FX1S-20MT-DSS128
FX1S-30MT-DSS1614
QTYTYPEQTYTYPE
4
24V DC
Sink /
Source
Transistor
(Source)
POWER
SUPPLY
24 VDC
+10, -15%
DIMENSIONS
mm (inches)
60
(2.4)
75
(3.0)
100
(3.9)
90
(3.5)49(1.9)
MASS
(WEIGHT)
kg (lbs)
0.22
(0.48)
0.30
(0.66)
0.35
(0.77)
1-2
FX1S Series Programmable ControllerIntroduction 1
Figure 1.1: FX1S Outline Drawing
5(ES/UL)/49(DS,DSS)
7
DINRail(35mm)
100-240
24V
VAC
LN
Y0Y2Y1
COM0
W
W-8
S/S
X0
COM2COM1
X2
Y30VY5
X3
X7X1
X4X5X6
01
23
6754
IN
POWER
RUN
ERROR
FX1S-14MR
01
45
14MR
Y4
-ES/UL
OUT23
82
90
2-φ4.5
The distance between the vertical centerlines is 8mm (0.31”) less than the width of the unit.
Please see previous page for each model’s width measurement.
1-3
FX1S Series Programmable ControllerIntroduction 1
1.1Model Name
FX1S-14MR-ES/UL
A)
B)
C)
Table 1.4: Model Table
F)
E)
D)
A)
B)
C)
D)
PLC type: FX
Total number of I / O channels
Unit type
MMPU - main unit
Output type
RRelay
TTransistor
1S
Features
Omit AC Power Supply, Japanese specification
DDC Power Supply, Japanese specification
DC Power Supply, World spe cification, Relay
DS
E)
DSS
F)
Output
DC Power Supply, World specification, DC source
transistor output
AC Power Supply, World specification, relay
ES
output
ULCE, UL registered product
1-4
FX1S Series Programmable ControllerIntroduction 1
1.2World Specification
Table 1.5: World / Japanese Specifications
Input
Sink / Source
Outputs
Transistor
World spec models : SINK / SOURCE
Japanese models : ALWAYS SINK
World spec models : ALWAYS SOURCE
Japanese models : ALWAYS SINK
can use one unit or communication board per square B, C, and G concurrently.
F
1-6
FX1S Series Programmable ControllerIntroduction 1
1.4.1Unit Accessories
Table 1.7: Configuration Notes
AFX1S Controller Main Body
BFX1N Memory Cassette or Display Unit
CFX
DFX0N Network Adaptors
EProgramming Cables
FProgramming Software
GHMI Devices, F900 GOT and FX-DU Series
HDedicated Programming Tools
Expansion Boards
1N
Table 1.8: Connection Ports
1
Memory Port
2
Extension Board Port
3
Programming Port
1-7
FX1S Series Programmable ControllerIntroduction 1
1.4.2Limits of Expansion
1S
The following conditions cannot be accomplished the FX
Series PLC:
-The use of Special Function Blocks.
-Supply a 5V DC service supply.
-Use FX
-Use the FX
1N
-422-BD + FX-2PIF.
1N
-5DM and the FX-10DM concurrently.
-Use more than one FX-10DM at the same time. For example, the configuration
FX-10DM + (FX
1N
1.5EEProm Backup Data
FX1S existing data will be kept for 5 minutes during power down before the data is lost.
The capacitor back ed memory will retain programs for 10 da ys and the capaci tor requires 30
minutes to recharge upon powerup.
-422-BD + FX-10DM) is not allowed.
1-8
FX1S Series Programmable Controllers
1Introduction
2Terminal Layouts
3Installation Notes
4Power Supply
5Inputs
6Outputs
7Diagnostics
FX1S Series Programmable Controllers
FX1S Series Programmable ControllersTerminal Layouts 2
S/S
X1
NX0X4X6
FX1S-20MR-ES/UL
X5X7
0VY0Y1Y2Y3
X3
X2
24V
COM0 COM1COM3 COM4COM2
L
X11 X13
X10 X12
Y5Y6Y7
Y4
S/SS/S
N
S/S
X2X4
FX1S-30MR-ES/UL
X3X5
0VY0Y1Y2Y4
X1
X0
24V
COM0 COM1
Y3Y5
COM2
L
X7X11X6X13 X15
X12X10X14 X16
X17
Y6
Y7Y11
Y10
Y14Y12
Y13
COM4
Y15
COM3
S/SX1
NX0X4
FX1S-10MR-ES/UL
X5
0V
Y0Y1Y2Y3
X3
X2
24V
COM0 COM1COM3COM2
L
S/SX1
NX0X4X6
FX1S-14MR-ES/UL
X5X7
0VY0Y1Y2Y4
X3
X2
24V
COM0 COM1
Y3Y5
COM2
L
2.Terminal Layouts
The following selection of terminal layouts are taken from the FX1S product range.
Note: All layouts are diagr ammatic only and are intended to aid the creation of wiring diagrams.
2.1FX1S-**MR-ES/UL
Figure 2.1: Terminal Layouts, Relay Outputs, AC Power
2-1