Mitsubishi FX1N-4EX-BD User Manual

Art.No. 141176 Version A JY992D95001 2001 10 18
FX1N-4EX-BD Input Expansion Board
USER’S MANUAL
JY992D95001A
This manual contains text, diagrams and explanations which will guide the reader in the correct installation, safe use and operation of the FX understood before attempting to install or use the unit. Further information can be found in the associated manuals list below.
Specifications are subject to change without notice
1N
Guidelines for the Safety of the User and Protection of the FX
-4EX-BD.
1N
This manual has been written to be used by trained and competent personnel. The definition of such a person or persons is as follows:
a) Any engineer using the product associated with this manual, should be of a competent nature,
trained and qualified to the local and national standards. These engineers should be fully aw are of all aspects of safety with regards to automated equipment.
b) Any commissioning or service engineer must be of a c ompetent nature, trained and qualified to
the local and national standards.
c) All operators of the completed equipment should be trained to use that product in a safe and
coordinated manner in compliance to established safety practices.
The term ‘completed equipment’ refers to a third party constructed device which contains or uses
Note:
the product associated with this manual.
Note’s on the Symbols Used in this Manual
At various times through out this manual certain symbols will be used to highlight points of information which are intended to ensure the users personal safety and protect the integrity of equipment.
1) Indicates that the identified danger
cause physical and property damage.
WILL
2) Indicates that the identified danger could damage.
Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment.
All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accep t no responsibili ty for actual use of the product based on these illustrative examples.
Owing to the very great variety in possible application of this equipment, you must satisfy yourself as to its suitability for your specific application.
POSSIBLY
cause physical and property
Associated manuals
Manual name Manual No. Description
1S
Series
FX Hardware Manual
1N
FX
Series
Hardware Manual FX
Programming
II
Manual
JY992D83901
JY992D89301
JY992D88101 Describes instructions in FX
Describes contents related to hardware of FX as specifications, wiring and installation.
Describes contents related to hardware of FX as specifications, wiring and installation.
1S
/FX1N/FX2N/FX
1S
Series PLC such
1N
Series PLC such
2NC
Series.
1. Introduction
The FX1N-4EX-BD Input Expansion Board (hereafter referred to as "FX1N-4EX-BD" or "Function expansion board") is a function expansion board to be installed in the FX
1S
or FX1N series programmable
controller (hereafter referred to as "PLC"), to increase the input of four points.
1.1 Features of the FX1N-4EX-BD
1) Additional increase of four input points.
2) Internal mounting in the top of the PLC meaning no need for change to the installation area of the PLC.
3) Additional inputs have special auxiliary relays allocated to each point, which are turned ON and OFF depending on the input state of the FX
1N
-4EX-BD. As special auxiliary relays are used in the PLC program for the input points, the additional inputs are not included in the regular system I/O count.
1.2 External Dimensions and Each Part Name
43(1.69")
3)
2)
1)
BX2S/S BX1BX0 BX3
2)
5)
4)
Dimensions: mm (inches) Accessories : Top cover for board 1
M3 screw to mount board 2 M3 screw to fix top cover 1
1) Input terminal. S/S : Power supply terminal BX0 : Terminal of input BX0
38.5(1.52")
BX1 : Terminal of input BX1 BX2 : Terminal of input BX2 BX3 : Terminal of input BX3 The top face of this connector is higher than the top face of the PLC panel cover by approximately 7 mm.
2) Mounting hole (2-φ3.5(0.14"))
3) Input LED BX0 LED : The LED lights when BX0 is turn on. BX1 LED : The LED lights when BX1 is turn on. BX2 LED : The LED lights when BX2 is turn on. BX3 LED : The LED lights when BX3 is turn on.
4) External port for display module FX memory cassette FX
5) External connector for PLC
1N
-EEPROM-8L
1N
-5DM or
1.3 System confi gurati on
Only one function expansion board can be used on one FX1S or FX1N series PLC main unit. Do not try to install two or more expansion boards.
1N
•FX
When using with the memory cassette FX
-4EX-BD can be used together with an FX1N-5DM.
Refer to the FX
1N
FX
-5DM.
1S
or FX1N HARDWARE MANUAL when using the FX1N-4EX-BD together with an
1N
-EEPROM-8L, only program transfer is possible.
(The memory cassette cannot be connected permanently)
1.4 Applicable PLC
Series name Applicable version
FX FX
1S 1N
V2.0 or later V2.0 or later