Mitsubishi Electronics DX-ZD6UE User Manual

HDD Extension Unit
INSTALLATION AND OPERATION MANUAL
MODEL
DX-ZD6UE
ENGLISHDEUTSCHFRANÇAISESPAÑOLITALIANONEDERLANDS
THIS INSTRUCTION MANUAL IS IMPORTANT TO YOU. PLEASE READ IT BEFORE USING YOUR HDD EXTENSION UNIT.
1
Caution and care
HEAVY OBJECTS SHOULD NEVER BE PLACED ON THE UNIT (E.G., MONITOR)
NEVER TOUCH OR INSERT ANY OBJECT INSIDE THE UNIT
Touching the inside of the cabinet or inserting foreign objects of any kind through the ventilation holes not only creates a safety hazard but can also cause extensive damage.
PROTECT THE POWER CORD
Damage to the power cord may cause fire or shock hazard. If the mains cord is damaged, turn OFF the MAIN switch and care fully unplug the cord by holding the mains plug.
If this unit is moved with the power on status, the HDDs may be damaged. Ensure that more than one minute have passed since the power cord and the connecting cords were disconnected, then move this unit.
UNPLUG THE POWER CORD DURING A LONG ABSENCE
Turn off the power and unplug the power cord during a long absence.
MAINTAIN GOOD VENTILATION
Do not obstruct the many ventilation holes on the unit. For maximum ventilation, leave some space around the unit and place the unit on a hard level surface only, and ensure it is not covered during use. Heavy objects should never be placed on the unit.
WHEN NOT IN USE
When not in use, always turn OFF the MAIN switch.
CABINET CARE
Never use petroleum-based cleaners. They may cause deterioration or coat flaking of the unit. Clean with a soft cloth moistened with soap and water and wipe dry.
When using chemical duster, follow the instructions.
INSTALLATION LOCATION
For excellent performance and lasting reliability install in a location that is:-
1. Well ventilated, out of direct sunlight and away from direct heat.
2. A solid vibration-free surface.
3. Free from high humidity, excessive dust and away from magnetic fields.
4. Please ensure that the ventilation fan located on the unit’s back panel is not blocked.
UNSUITABLE LOCATIONS
Placing the unit in the following places might shorten the product life:
• Extremely cold places, such as refrigerated warehouses and ice houses
• Places where excessive hydrogen sulfide is likely to be generated, such as hot-springs areas
• Places or locations with salt air environment.
NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS. DO NOT PLACE HEAVY OBJECT ON THIS UNIT. DO NOT STEP ONTO THIS UNIT.
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
THIS APPARATUS MUST BE GROUNDED.
-
This unit complies with the requirements of the EC Directive 2004/108/EC, “EMC Directive” and 2006/95/EC, “Low Voltage Di­rective”. The requirements for the susceptibility according to EN 55024 and the requirements for interference according to EN 55022 are observed for the operation on residential areas, business, light industrial premises and in small scale enterprises, inside as well as outside of the building. All places of operation are characterised by their connection to the public low voltage power supply system. This unit is manufactured in accordance with EN 60950-1.
Note: This symbol mark is for EU countries only. This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV.
Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and compo nents which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste. Please, dispose of this equipment at your local community waste collection/recycling centre. In the European Union there are separate collection systems for used electrical and electronic product. Please, help us to conserve the environment we live in!
WARNING: The power cords for use in the U.S., the continent of Europe, and U.K. are included with this unit. Use the appropriate one for your country. The power cord for use in the U.S. is used for 120V only. Never connect to any outlet or power suply having a different voltage or frequency.
-
2
ENGLISH
MAINS LEAD CONNECTION
The mains lead on this Unit is fitted with a non-rewireable mains plug, incorporating a 5A fuse. If you need to replace the fuse, use a 5A fuse approved by BSI or ASTA to BS 1362, ensuring you refit the fuse cover. If the mains plug is not suitable for the sockets in your home, and you require to remove the plug, remove the fuse, cut off the plug then dispose of the plug immedi ately, to avoid a possible electric shock hazard. To refit a new plug, follow these instructions; Green-and-yellow: Earth, Blue: Neutral and Brown: Live. As the colours in the mains lead of this Unit may not correspond with the coloured markings identify ing the terminals in your plug, proceed as follows.
• The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured green or green-and-yellow.
• The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
• The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
-
-
Before you start recording important images, make sure to perform trial recording to ensure that images are properly record ed. Mitsubishi assumes no resonsibility or reliability for any loss of recorded data and any failure of playback data arising out of malfunction of this unit or the connected device. It is recommended that backups of important recordings are made regu larly as a precaution against possible breakdowns and accidents.
• This unit uses a hard disk, which is a precision device. Please handle this unit with sufficient care.
• Do not subject this unit to vibrations or shocks. Vibrations and shocks may cause trouble especially while the recorder is on or the hard disc drive is being accessed.
• Do not disconnect the power plug or the USB cable while the power of the unit is turned on or while recording or playing.
• It is recommended to ask for inspection every one year for early detection of failure.
• Do not move this unit at least one minute after the power is turned off.
• If the power plug is disconnected or the breaker switch is turned off during recording, HDD may be damaged or playback of recorded data may become impossible.
If the breaker switch is turned on and off everyday, set the timer recording to be performed only for the period that the
breaker is on and do not turn off the breaker during recording.
• It is recommended to check periodically that recording is performed successfully by playing back the recorded data.
The HDD and cooling fan of this unit are driving parts. For stable recording, it is recommended that both of these parts are replaced every 30,000 hours. (This interval is for reference purpose only and does not indicate the warranty period of the parts.)
INSTALLATION LOCATION AND HANDLING
• Do not plug this unit into the same outlet which is being used for other large power consuming equipment such as a copying machine and air conditioner.
• Do not place this unit close to other equipment to prevent adverse interference between them.
• Do not place this unit close to strong magnetized objects. They may cause effects on the images or loss of recorded data.
• Never apply volatile substances such as insecticides and do not put rubber- or plastic-products on the unit for a long period. They may cause deterioration of this unit or flaking of the coa
• Install the unit within the allowable ambient temperature range (5 Using this unit out of these ranges may adversely affect the internal parts or cause malfunction. When the temperature of the HDD rises high, its performance may deteriorate or its lifetime may be shortened. When using this unit at a low temperature, turn on the power and wait for 10 minutes or more before use.
WHEN MOVING THIS UNIT
• When you move this unit, make sure to turn off the power and unplug. When a strong shock is applied to this unit while it is on, the electronic parts inside the unit may be damaged. Take care especially while the ACCESS indicator is illuminating.
• When you move this unit, wrap it with cushions to avoid shock to the internal parts.
COPYRIGHT
• This unit records images digitally. When recording copyrighted images, be careful not to infringe their copyrights.
ting.
°C to 40 °C) and relative humidity range (less than 80%).
-
-
Disclaimer
In any event, Mitsubishi assumes no responsibility or reliability for the following:
1. Disassembly, repair, or alteration of this unit by user or installer.
2. Failure or breakdown in or damage to this unit resulting from misuse or careless handling by user or installer.
3. Inconvenience or damages arising out of inability to display or record images due to any reason or cause other than break
4. Failure in this unit due to combination with other equipment manufactured by a third party or inconvenience or damages
5. Inconvenience, damages, or claims arising out of breakdown in this unit or loss of recorded video data due to replacement
6. Inconvenience or damages arising out of breakdown in this unit or inability to display or record images due to natural dis
7. Inconvenience, damages, or claims arising out of breakdown in this unit or loss of recorded video data due to impact or
8. Demand for damages or other claim of infringement of privacy if the images monitored or recorded by user become public
-
down or failure in this unit.
resulting from such failure.
of the HDD by user or installer.
-
aster including earthquake and storm.
vibration to the HDD or an environmental factor such as temperature at the installation site.
or are used for any purpose other than surveillance for whatever reason.
3
Features/Contents
HDD UNIT ID
**
S
HDD operation mode (specified by the MODE rotary switch on this unit)
M ...... Mirroring mode
S......... Spanning mode
ID number (specified by the ID rotary switch on this unit)
Tips
Notice
Features
HDD extension unit having a large-capacity hard disc drive (HDD)
This unit is equipped with a high-reliability, high-speed, and large-capacity hard disc drive.
HDD operation mode
Among 2 HDD operation modes of spanning and mirroring, you can select the desired one.
Power linkage function
The power of this unit can be turned on/off by linking with the connected MITSUBISHI digital recorder's power supply.
Warning function
This unit is equipped with the terminal for informing of abnormal temperature rise and HDD error.
Direct connection with a personal computer
You can connect this unit to a personal computer directly via a USB cable and playback the data recorded by this unit on the personal computer using the special playback software. Consult your dealer for the special playback software.
The name of this unit is shown on the personal computer as follows.
Contents
Important safeguards ................................................... i-iv
Caution and care ..............................................................2
Features ............................................................................4
Contents ............................................................................4
Major operations and their functions .............................5
Front view ........................................................................ 5
Rear view ......................................................................... 6
Connections ........................................................................8
Connectable recorders .................................................... 8
Connection example ........................................................ 8
Connection to link the power supply of the recorder
and this unit .................................................... 8
Precautions for connection ......................................... 9
Startup ........................................................................... 10
Setting the ID number of this unit ................................... 11
Setting the ID number of this unit ...................................11
Setting the mode of this unit ........................................... 12
HDD operation mode ..................................................... 12
Mode selection ............................................................... 12
Replacing the HDD .........................................................14
Precautions for replacing the HDD ................................ 14
Removing the HDD ........................................................ 14
Attaching the HDD ......................................................... 16
Troubleshooting .............................................................18
Diagnosis by HDD indicators ......................................... 18
Troubleshooting .............................................................
Maintenance .................................................................. 19
Specifications ................................................................... 20
How to read this manual
Viewing displays
(Refer to this information when operating):
Reference information concerning operation
(Caution required):
Cautionary items concerning operation
(See reference page):
Reference item and page number
19
Warning
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
4
ENGLISH
1
2
3
4
Major operations and their functions
Front view
1 POWER indicator
When the EXTERNAL CONTROL switch is set to OFF or it is set to ON with the connected recorder turned on, this indicator illuminates while the MAIN switch on the rear panel is turned on.
2 HDD1, HDD2 indicators (ACCESS indicators)
While HD D 1 o r H D D 2 is being ac c e s s e d , the corresponding indicator momentarily blinks green. They keep blinking during recording/copying of data. In case of an error, they blink or illuminate red. ( See page 18.)
3 TEMP indicator
Illuminates when the internal temperature of this unit becomes high.
4 FAN indicator
Illuminates when the fan stops.
5
Notice
Notice
1
3
5
6
7
8
4
2
Major operations and their functions (continued)
Rear view
1 MAIN switch
This is the main power switch. When using this unit, set this switch to ON.
2 AC power socket
Used to connect the power cord. Earth terminal is used for safety. Make sure to use the 100 to 240 V plug with earth for the power of this unit.
Wh en the powe r o u t l e t does not h a v e a n earth terminal, a sk your dealer for the ear th work (p ay service). Never connect t he ear th ter minal of the power plug to a gas pipe, water pipe, conductor rod, and so on.
Use the supplied AC power cord.
Make sure to plug this unit into the outlet of the same power line that is used for the recorder connected. When this unit is plugged into the outlet of other line, recording or copying will not be resumed correctly after a power failure.
3 I/O terminals
CONT IN terminal
Terminal for inputting the power on/off status of the recorder. Connect this terminal with the DC 12V OUT terminal on the rear of the recorder.
CONT OUT terminal
Terminal f or output ting the power o n/off statu s of the recorder. When using multiple number of HDD extension units and using the power on/off linkage fu nct ion, co nne ct t his ter minal w ith the CON T IN terminal on the rear of the HDD extension unit to be connected.
GND terminals
They are the common GND terminals. When using the power on/off linkage function, connect this terminal with the GND terminal on the rear of the recorder.
TEMP ALM terminal
Terminal for informing of high internal temperature.
FAN ALM terminal
Terminal for informing of abnormality of the fan.
HDD ALM terminal
Terminal for informing of abnormality of the HDD.
4 EXTERNAL CONTROL switch
Set this switch to ON (left side) to turn on and off the power of this unit linking with the recorder’s switch. When not linking with the recorder, set this switch to OFF (right side).
When the EXTERNAL CONTROL switch is set to ON, make sure to perform “Connection to link the power supply of the recorder and this unit” on When the recorder is turned on, this unit is turned on at the same time.
It is recommended to link this unit with the recorder in order to allow the internal hard disks to rest or to properly handle a problem, if occurs.
page 8.
5 CONT IN terminal
Reserved.
6 CONT OUT terminal
Reserved.
7 SERIAL BUS IN port
Port for connecting with the recorder.
8 SERIAL BUS OUT ports
Ports for connecting with another DX-ZD6UE when using multiple number of DX-ZD6UE.
6
ENGLISH
Notice
It is impossible to supply 5V DC power from this port.
Do not connect any devices other than DX-ZD6UE to these output ports.
7
Connections
Supplied USB cable
Supplied USB cable
To SERIAL BUS port
To SERIAL BUS IN port
To SERIAL BUS OUT port
To SERIAL BUS IN port
100-240V
AC IN~
MAX 350mA
DC 12V OUT
CLOCK ADJ
CLOCK ADJ OUT
REC
REC STOP
EMERGENCY
RESERVED
MODE OUT 1 +
MODE OUT 1 –
MODE OUT 2 +
MODE OUT 2 –
MODE OUT 3 +
MODE OUT 3 –
MODE OUT 4 +
MODE OUT 4 –
CALL OUT +
CALL OUT –
GND
GND
GND
GND
1
ALARM IN
2345678
9
10111213141516
RS485 TERM +
RS485 TERM –
P T Z
RS422
+
RS422
RS232
1
ALARM OUT
2345678
9
10111213141516
RS-232C
RS485RS485
INOUT
MAIN
OFF ON
RESET
OPTION SLOT
LAN-A LAN-B
STORAGE COM
SERIAL BUSSERIAL BUS
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
OUT
IN
CAMERA
OUT
IN
Y/C
OUTPUT B
CLAMPER
CLAMPER
OUTPUT A
VIDEO VIDEO
VIDEO CASCADE
INOUT
1010010100
AUDIO IN
1
2
3
4
OUT
IN
AUDIO CASCADE
AUDIO OUT
This unit
Digital recorder DX-TL5000E400 (example)
Digital recorder DX-TL5000E400 (example)
This unit
Connectable recorders
MITSUBISHI DIGITAL RECORDER
DX-TL5000 series (DX-TL5000U, DX-TL5000E, DX-TL5000UA, DX-TL5000E400, DX-TL5000E(Z))
DX-TL4500 series (DX-TL4516E, DX-TL4516E(Z), DX-TL4516U, DX-TL4509E, DX-TL4509E(Z), DX-TL4509U)
The above stated models are connectable as of October 2007. Consult your dealer for the connection with other recorders.
Connection example
Connect this unit and a digital recorder by using the supplied USB cable.
You can connect multiple DX-ZD6UE as shown below.
Connection to link the power supply of the recorder and this unit
Set the EXTERNAL CONTROL switch to ON (left side) and connect the terminals as shown below. It is recommended to link this unit with the recorder’s power supply.
To resume recording or copying after a power failure during normal recording or timer recording, plug this unit into the outlet of the same power line that is used for the recorder connected.
8
ENGLISH
Notice
IN
OUT
IN IN
IN
OUT
ININ
OUT
IN
This unit This unit
This unit
This unit
This unit
This unit
This unit
OUT
IN
This unit
OUT
IN
This unit
OUT
IN
This unit
This unit
This unit
OUT
IN
This unit
OUT
IN
This unit
OUT
IN
OUT
IN
Digital recorder
* When 2 serial bus ports are used.
Tips
Precautions for connection
When connecting 5 or more HDD extension units (with 2 HDDs mounted on each unit) to the digital recorder, you are recommended to use USB cable as illustrated below to prevent recognition error of digital recorder due to different start-up times among HDDs.
Furthermore, before you start operation or when the power restores from a power failure, check that the HDDs are
recognized correctly even when a small number of HDD extension units are connected.
The EXTERNAL CONTROL switch is set to ON by default. In this status, this unit does not work even though you connet the power cord and set the MAIN switch to ON.
Connect this unit and the recorder as “Connection to link the power supply of the recorder and this unit” on
page
10.
The available number of HDD extension units to be connected varies depending on the recorder connected. Check the specification of the recorder.
You cannot connect 6 or more HDD extension units in series using serial bus.
The number of serial bus ports varies depending on the digital recorder connected. For stable recording, it is
recommended to use the ports of the recorder as many as possible to avoid branch connection of the extension units.
9
Step
Step
Step
Tips
Connections (continued)
Startup
1 Turn ON the MAIN switch on the rear of this unit.
2 Turn on the MAIN switch on the rear of the recorder.
• The POWER indicator of this unit illuminates when the power supply of this unit is not linked with the recorder.
3 After “POWER OFF” is displayed on the LCD of the recorder, press the POWER button on the front panel of
the recorder.
• The indicators of HDD 1 and HDD 2 on the front panel of this unit momentarily blink green.
• When the power supply of this unit is linked with the recorder, you can turn on the power of this unit by pressing the POWER button on the front panel of the recorder.
• When the power of the recorder is turned on, the connection is completed.
For the operation of the recorder, refer to the installation and operation manual supplied with the recorder.
10
ENGLISH
Step
Step
ID rotary switch
Inside the front cover
Step
ID
rotary switch
ID number
Spanning
operation
Mirroring operation
ID00S
ID01S
ID02S
ID03S
ID04S
ID05S
ID06S
ID07S
ID08S
ID09S
ID10S
ID11S
ID12S
ID13S
ID14S
ID15S
ID00M
ID01M
ID02M
ID03M
ID04M
ID05M
ID06M
ID07M
ID08M
ID09M
ID10M
ID11M
ID12M
ID13M
ID14M
ID15M
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Step
Step
Setting the ID number of this unit
Setting the ID number of this unit
1 Turn OFF the MAIN switch on the rear of this
unit.
2 Remove the cover of this unit according to steps
1 to 3 of “Removing the HDD” on page 14.
• The ID numbe r is set using the ID rotary switch inside the cover.
3 Set the ID rotary switch to the desired number.
• The ID number set in this step is displayed on the digital recorder's menu screen that is used to register the device.
4 Attach the cover of this unit according to steps 9
to 11 of “Attaching the HDD” on page 17.
5 Turn ON the MAIN switch on the rear of this unit.
11
Notice
Notice
Step
Step
MODE rotary switch
Inside the front cover
Step
Step
Step
Step
MODE
rotary switch
HDD operation
mode
Do not use.
Spanning
Mirroring
Do not use.
Do not use.
Do not use.
Do not use.
Do not use.
Do not use.
Do not use.
0
1
2
3
4
5
6
7
8
9
Setting the mode of this unit
HDD operation mode
This unit has 2 HDD operation modes as described below.
Spanning mode
This mode regards and uses 2 built-in HDDs as 1 HDD. The total data capacity of 2 HDDs is available.
When either of the HDDs fails in the spanning mode, both of the HDDs become unusable and the recorded data are deleted.
Mirroring mode
Th i s mo de re cords the sam e dat a to 2 bu i lt-i n HDD s simultaneously.
Even when either of the HDDs fails, by replacing the failed HDD, the data stored in the other HDD are automatically co p i ed to t h e ne w l y mo u nt e d H D D an d th e HD D s are restored t o the c ondition befor e the f ailure. ( Data synchronization)
Synchronization of 500-GB data takes about 8 hours. This time is approximate and given as a guide only, assuming that this unit performs no other operations during the data synchronization. Therefore, a longer time is required for the data synchronization when the unit is in the playback or recording mode.
Whe n the data sync h roniz a tion i s int e rrupt e d by the operat i o n su c h as power-o ff, th e un i t r e s umes the synchronization after the power is restored.
When you replace the failed HDD in the mirroring mode, make sure to use an unused HDD. If you mount a used HDD, delete the management information of that HDD. (See “How to set the mode” on the right column.) If you mount a used HDD without deleting its management information, the data synchronization may not be performed correctly. (Do not delete the management information with the existing normal HDD mounted because the data is deleted.)
Mode selection
1 Turn OFF the MAIN switch on the rear of this
unit.
2 Remove the cover of this unit according to the
steps 1 to 3 of “Removing the HDD” on
14.
• The mode is set using the MODE rotary switch inside the cover.
3 Set the MODE rotary switch to 7.
• Be f o r e you change th e H D D operation mode , delete the management information according to steps 3 to 5. You may skip these steps when you mount an unused HDD. When you mount a used HDD, the HDD cannot be used properly unless the management information is deleted before changing the HDD operation mode.
4 Press the RESET button.
5 After the unit boots up and the buzzer sounds,
press the TEST button.
• The management information deletion function is activated and the ACCESS indicator starts blinking. Upo n com p letio n of t h e del e tion, the i ndica t or illuminates green.
6 Se t the MODE ro t a r y s w i t c h to the number
corresponding to the desired operation mode.
page
12
ENGLISH
Step
7 Attach the cover of this unit according to steps 9
Step
to 11 of “Attaching the HDD” on
page 17.
8 Turn ON the MAIN switch on the rear of the unit.
13
Replacing the HDD
Notice
Notice
Step
Notice
Step
Step
Precautions for replacing the HDD
WARNING
Do not remove the top cover of the unit.
Be f ore yo u r epla c e the HD D , read "I m porta n t safeguards" on Care" on pages 2 and 3 again.
Do not att ach or remov e the H DD unnece ssarily. Attaching or removing the HDD of this unit is intended for replacing a failed HDD, not for use as a removable HDD.
Make sure that the MAIN switch on the rear panel is turned OFF when attaching or removing the HDD. Wait at least 1 minute after turning off the power. When a recorder is connected, turn off the recorder, too.
When a power failure occurs during recording, avoid adding, replacing or transporting the HDD. In case of a power failure, as the recorded data may be erased, turn the power back on to boot up the unit with the HDD that was being used at the time of the power failure attached. Then add, replace or transport the HDD.
Wh e n the USB ca b l e connect e d to t his uni t is disconnected or a power failure occurs only with this unit, data is recorded to other HDD unit in order to continue recording.
HDD is very delicate. Handle the HDD with care and follow the precautions below because even a slight shock may damage the internal components of the HDD.
• Do not drop the HDD. Also, do not put a metallic
object such as a coin or a screw driver into the HDD tray.
• Gently place the HDD on a cushion so that it is
not subjected to shock.
• Do not use an electric screwdriver. Vibrations and
shocks caused by an electric screwdriver may damage the internal components of the HDD.
• When replacing the HDD, do not knock the HDD
with other components such as another HDD and the HDD tray.
• Do not knock the HDD with tools such as a screw
driver when replacing the HDD.
The following HDD has been tested and confirmed that the compatibility is ensured. This information is as of November 2007. Supply of this HDD may be stopped or it may be changed without notice by its manufacturer. Consult your dealer for the latest information or use of other HDDs. When you attach multiple HDDs, use the HDDs of the same capacity and the same model name, in principle.
<Hitachi Global Storage Technologies>
HDT725050VLA360 (500 GB, S-ATA)
pages i to iv and "Caution and
-
Removing the HDD
Make sure to turn the MAIN switch on the rear of this unit to OFF before attaching or removing the HDD.
1 Push the left end of the screw covers on both
sides of the cover to open.
Do not leave the screw cover open for general use.
2 Remove the screws.
3 Remove the front covers.
• Remove the cover on the right side first.
• Then, push the left cover to the right to remove.
14
ENGLISH
Step
4 Dis connect 2 cord s connected to the circuit
Step
Step
HDD1
HDD2
Step
Notice
S-ATA connectors
Step
Step
board on the metal part.
5 Remove the metal part.
• Remove 4 screws on the metal part.
8 Pull out the HDD tray.
• Pull out the HDD tray completely.
9 Remove the HDD.
• Re m ove 4 s c rews se c uring t h e HDD a n d then remove the HDD from the frame.
6 Pull out the HDD tray halfway.
7 Remove the cords.
Because S-ATA connectors of HDD are very delicate, conn e c t or di s c o n nect th e c o rds gen t l y withou t applying excessive force to the connectors.
Tak e specia l c a re to c o n n e ct or d i s c o nnect th e
connectors straight in order to prevent vertical force from being applied to them.
15
Notice
Step
Notice
Step
Step
Step
Step
Step
Step
Step
Replacing the HDD (continued)
Attaching the HDD
When you attach multiple HDDs, attach them in the order of HDD 1 and 2.
1 Attach the new HDD onto the HDD tray with 4
screws.
• Make sure to attach the HDD in the correct orientation.
5 Attach the metal part.
• Align the upper side first, then push the lower side into the unit.
• Take care not to deform the springs.
• Pass the cord to be connected to the circuit board through the hole in the metal part.
6 Fix the metal part with 4 screws.
When attaching the HDD to this unit, use the supplied screws.
2 Insert the HDD tray halfway.
3 Connect the cords.
4 Insert the HDD tray completely.
7 Connect 2 cords to the circuit board on the metal
part.
8 Check whether the HDD is connected properly.
1 Set the MODE rotary switch to any number from 0 to
5.
2 While the TEST button is pressed, press the RESET
button.
3 After the unit boots up and the buzzer sounds, press
the TEST button.
The HDD test function is activated and tests each
HDD f or 1 minu te, and t hen the t est results are shown by the ACCESS indicator.
When the indicator illuminates green, the connection
is completed successfully.
Wh e n the i n d i cator b l i nks re d , the H D D is no t
connected properly.
When the indicator illuminates red, the HDD is not
identified properly.
16
ENGLISH
Step
9 Attach the front covers.
Step
Step
Tips
• Attach the left cover first and push it to the left.
• Then, attach the right cover.
10
Fix the front covers with 2 screws.
11
Close the scre w cove rs on b oth si des of the
cover.
Follow the same procedures to attach or remove HDD
2.
17
No
No
No
No
No
Yes
Yes
Yes
Mirroring
Spanning
Yes
Yes
Yes
Both indicators of HDD 1 and HDD 2 illuminate
red.
Both indicators of HDD 1
and HDD 2 blink red.
Is the operation mode
set to spanning or
mirroring?
Is the operation mode
set to mirroring?
Either indicator of HDD 1 or HDD 2 illuminates red.
Is the MODE rotary switch set correctly? Is the cable connected correctly?
Is the MODE rotary switch set correctly?
The HDDs of different capacities may be used. Check the HDD capacity.
Is the operation mode
set to mirroring?
Though the HDD corresponding to the illuminating indicator is not identified, operation can be continued. The S-ATA cable may not be connected properly or a problem may occur in the HDDs.
The HDD corresponding to the illuminating indicator is not identified. The S-ATA cable may not be connected properly or a problem may occur in the HDDs.
During synchronization, a problem occured in the source HDD and that HDD became unidentifiable. The synchronization cannot be continued.
Both of the HDDs are not identified. The S-ATA cable may not be connected properly or a problem may occur in the HDDs.
START
Either indicator of HDD 1
or HDD 2 illuminates red and the other one blinks
red.
Troubleshooting
Diagnosis by HDD indicators
In the case that the HDD 1 or HDD 2 indicator on the front panel blinks or illuminates, check the problem in the HDD according to the chart below.
18
ENGLISH
Troubleshooting
Please check the followingDescription of problem
• Is the power cord properly plugged in?
• Is the EXTERNAL CONTROL switch set to ON though the DC 12 V OUT
terminal
of the recorder and the CONT IN terminal of this unit are not
connected ?
• Is the USB cable connected correctly?
• Are the menus set correctly in the recorder?
• Is the number of recording devices connected within the limitation?
• Does the HDD 1 or HDD 2 indicator blink or illuminate red?
• Is the MODE rotary switch set correctly?
• Is the information of this unit displayed on the menu for registering the
device?
Is the correct data capacity displayed?
• Did you delete the management information before changing the HDD
operation mode?
• Turn off the power. Turn on the power again after the internal temperature
drops.
• Replace the fan with a new one. Ask your dealer to replace the fan.
The unit does not turn on.
This unit does not work
correctly.
TEMP indicator illuminates.
FAN indicator illuminates.
If problems with the unit persist even after you followed the suggestions below, please stop using the unit, disconnect the power cord and contact the retailer from whom you purchased the unit.
The elapsed operating time, which can be a guide to know the periodic maintenance timing, is available in the menu of the recorder. Refer to the manual of the recorder. The indication of the operating time of the recorder may vary from the actual operating time. It is recommended to use this indication just for your reference.
When this unit is registered as a Main device, the elapsed operating time of this unit is not displayed. (The elapsed operating time of the recorder connected with this unit is displayed.)
Maintenance
19
Specifications
<Interface circuit inside the unit>
Output terminal
GND terminal
TEMP ALM terminal FAN ALM terminal HDD ALM terminal
• Output Circuit
General Rated Power Supply: 100 to 240 V AC, 50/60 Hz Rated Input: 0.75 - 0.4 A (100-240 V) Operating Temperature: 41 °F-104 °F (5 °C to 40 °C) Relative Humidity: Max. 80 (%) Altitude: Max. 2000 (m) Dimensions: 424 (Width) x 361 (Depth) x 49 (Height) (mm) Weight: 6.3 kg (with 2 HDD mounted)
Control terminals CONT IN Input terminal linked with the power supply of the recorder CONT OUT Output terminal linked with the power supply of the recorder (CONT OUT is the through output of CONT IN.) GND (Ground) For grounding TEMP ALM Output terminal for detecting abnormal temperature (open collector output) Active: “Low” level voltage output, Max. current 7 mA DC. Non active: Open, Max. voltage 24 V DC. FAN ALM Output terminal for detecting fan error (open collector output) Active: “Low” level voltage output, Max. current 7 mA DC. Non active: Open, Max. voltage 24 V DC. HDD ALM Output terminal for detecting HDD error (open collector output) Active: “Low” level voltage output, Max. current 7 mA DC. Non active: Open, Max. voltage 24 V DC.
CONT IN Reserved. CONT OUT Reserved.
EXTERNAL CONTROL: When set to ON: Power is supplied to the HDD when 12V is applied to the input terminal linked with the power supply. When set to OFF: Power is always supplied to the HDD.
Serial bus terminal Serial bus terminal (2 terminals) (Only DX-ZD6UE is connectable.)
Accessories: USB2.0 cable 1 Control cable 1 Screws 8 User’s manual (this manual) 1 Power cord 3
Control input/output terminals and circuits
Design and specifications are subject to change without notice.
20
MITSUBISHI DIGITAL ELECTRONICS AMERICA, INC.
9351 Jeronimo Road, Irvine, CA 92618, U.S.A. Phone 949-465-6000 www.mitsubishi-imaging.com Tech Support 888-307-0309 tsupport@mdea.mea.com
UK Mitsubishi Electric Europe B.V. UK Branch Offi ce Visual Information Systems Division Travellers Lane Hatfi eld Herts AL10 8XB
Telephone: +44 (1707)-278 684 Fax: +44 (1707)-278 541
GERMANY Mitsubishi Electric Europe B.V. German Branch Offi ce Electric Visual Systems Gothaer Str. 8 40880 Ratingen Germany
Telephone: +49 (2102)-486 9250 Fax: +49 (2102)-486 7320
SPAIN Mitsubishi Electric Europe B.V. Spanish Branch Offi ce Ctra. de Rubi, 76-80 Apdo.420 08190 Sant Cugat del Valles (Barcelona) SPAIN
ITALY Mitsubishi Electric Europe B.V. Italian Branch Offi ce Centro Direzionale Colleoni Palazzo Perseo - Ingresso 2, Via Paracelso 12, 20041 Agrate Brianza, Italy
Telephone: +39 (039)-605 31 Fax: + 39 (039)-605 3214
The Netherlands Mitsubishi Electric Benelux A Division of Mitsubishi Electric Europe B.V. Niiverheidsweg 23A, 3641 RP Mijdrecht Netherlands.
Telephone: +31 (297)-282 461 Fax: +31 (297)-283 936
Sweden Mitsubishi Electric Scandinavia Hammarbacken 14 Box750 SE-191 27 Sollentuna Sweden
Telephone: +34 (93)-565 3154 Fax: +34 (93)-589 4388
FRANCE Mitsubishi Electric Europe B.V. French Branch Offi ce 25, Boulevard des Bouvets 92741 Nanterre Cedex
Telephone: +33 (1)-5568 5500 Fax: +33 (1)-5568 5731
Telephone: +46 (8)-625 1000 Fax: +46 (8)-35 1132
Ireland Mitsubishi Electric Ireland A Division of Mitsubishi Electric Europe B.V. Westgate Business Park, Ballymount, Dublin 24. Ireland
Telephone: +353 (1)-419 8800 Fax: +353 (1)-419 8895
Loading...