1. About this Product
Instruction manual
Thank you very much for purchasing Cleansui. Read these instructions carefully before use. Installation instruction
and a warranty card are included with this product and must be retained for future reference.
Contents
Under sink water purifier
1. About this Product
2. Safety Precautions
3. Important Notes for Operation
4. Irregular Water Flow
5. Names of Parts
6. Features of Cartridge
7. Operating Instructions
8. Maintenance
9. Troubleshooting
10. Replacing the Cartridge
11. After-sales Service
12. Specifications
Warranty
Page 2
Attention
1.本製品について
Failure to follow the safety precautions can lead to a serious accident. They contain extremely important information related to safety and all the precautions must be observed without fail.
The following warning labels indicate the items you should follow for your safety.
Indicates failure to observe these instructions can cause minor injury to the user or damage to surrounding properties.
Attention
Indicates “prohibited” actions.
Indicates the parts which “should not be removed”
Indicates “mandatory instructions”.
Prohibition
Do Not
Disassemble
Instruction
Instruction
Instruction
Instruction
The degrees of potential danger and damage that can be caused from any improper usage,
ignoring the contents of the safety precautions are explained below.
2. Safety Precautions
Handling of filtered water
Please use tap water that meets the local standards for drinking water.
It cannot be used to purify hot-spring water, well water or any other water that contains large amounts of impurities. Uses of the water filter in this way may be detrimental to your health.
If any part of the system is damaged (such as damaged coating), do not touch the damaged area.
This may cause injury, if there is damage, please contact the dealer.
Please consume filtered water as soon as possible
When you store filtered water, please store it in a clean container with a sealed cap in a refrigerator. Because there is no residual chlorine in the filtered water, bacteria may easily multiply.
Please run the filtered water for at least 15 seconds before using your Cleansui for the first time everyday. (for UZC2000E)
Because there is no residual chlorine in the filtered water left in the system, bacteria may easily multiply. This may cause damage to your health.
Please run the filtered water for at least 1 minute to discharge accumulated water when Cleansui has not been used for 2 or more days.
Because there is no residual chlorine in the filtered water left in the system, bacteria may easily multiply. This may cause damage to your health.
Instructions prior to use
To keep the system clean
Do not use filtered water in fish tanks, etc.
When the filtration performance declines through usage, residual chlorine may remain in filtered water. This may be fatal to fish.
Prohibition
2
Page 3
×
Attention
Prohibition
Instruction
Instruction
If water scale. is mixed into filtered water, change the hoses or faucet.
Water scale etc. may be mixed into filtered water due to the condition of usage or the period of usage.
If the wateroutlet becomes soiled by splash back., run filtered water for more than 15
seconds.
Bacteria may multiply.
For maintenance of the wateroutlet, clean with a sterilized soft toothbrush etc.
Bacteria may multiply.
Do not touch the wateroutlet with your hand or dishcloth.
Bacteria may multiply.
Please connect the cartridge and the hoses correctly.
If they are connected incorrectly, it may cause the water to become blackened (activated carbon) or cause damage or leakages.
Do not refrigerate the device.
Doing so will may result in ruptures and leaks.
If the system has not been used for more than 2 weeks, please replace the cartridge.
Please be careful when operating the lever.
If the level is closed suddenly, this may result in impacted pipes leading leakage and other damage to the pipes.
Ensure that the dedicated faucet is closed when you change cartridge.
It may cause property damage by leakages.
If the equipment is not used for a prolonged period of time, close the stop valve or water
main in the plumbing.
It may cause leakages.
If seasonings that contain salt, stick to the metal pipes, the hoses or cartridge, please
wipe with a clean damp cloth to remove salt.
It may cause rust or resin deterioration which leads to damage and leakage.
Make sure that one-touch joint connection is plugged in completely when you change
cartridge.
It may cause property damage by leakages.
Regularly check if there are any leakages or rattling around plumbing.
It may cause property damage by leakages.
If you place bleach or chemicals. under the sink, close the cap tightly.
Volatile bleach or chemicals. may cause damage or leakage.
Replace cartridge regularly.
Recommended cartridge replacement period is 12 months. Continuous usage of the cartridge which is exhibiting reduced water volume output, due to clogging, may cause damage and leakage, which may result in property damage. Water purifying performance may not be adequate with the cartridge that has passed the recommended replacement period.
To prevent filtered water irregularities, leakage and ruptures
To keep the system clean
3
Page 4
Attention
Prohibition
Do Not
Disassemble
Do not block faucet or connect it to other equipment, such as gas boiler etc.
It may cause leakages.
Do not apply strong force or shock to the product.
It may cause leakages.
Do not hang heavy objects on the water-outlet pipe or turn with strong force.
It may cause leakages.
Do not disassemble the main body or cartridge of the water filter.
It may cause leakages. If the purifier is not working properly, please refer to the section "9. Troubleshooting" before requesting maintenance or repairs.
Do not use detergents that contain abrasive compounds or thinners for cleaning the faucet, cartridge and the hoses.
It may cause leakages.
Never allow acid-based detergent, chlorine-based bleach or vinegar to contact the faucet, cartridge or the hoses.
It may cause leakages.
Do not allow hot frying pans or kettles to come in close contact with cartridge or the hoses under the sink. It may cause property damage by leakages.
It may cause leakages.
Do not exceed the stated bending radius of the hoses.
6 cm radius is the utmost limit of bending. It may cause reduction of water volume, damage or leakages.
To prevent filtered water irregularities, leakage and ruptures
4
Page 5
5
Use the recommended Cleansui cartridge with Cleansui faucet.
Do not use this device to filter hot water with a temperature of 35
℃or higher through
"filtration" mode.
If you do so, the performance of activated carbon is reduced and the filtered water may temporarily exhibit an unpleasant odour temporarily.
If the tap water has not run for a long time or it contains red rust (turbidity), please allow the
water to flow for a while before using the water filter to avoid shortening the cartridge life.
In areas with high water pressure, it may cause water to splash. Please reduce the water flow
with the stop valve .
In areas with high water pressure, a noise may occur while purifying water. In addition if the
water volume is too high, the purifying performance may be unsatisfactory. Please adjust the volume with the faucet lever or stop valve.
Where the water pressure is extremely low, the water may not come out easily after replacing
cartridge. In that case, run water for about 10 minutes. The water flow will improve.
3. Important Notes for Operation
Page 6
6
Please follow the steps if the water flow is irregular after the filter has been installed or replaced.
Allow the filtered water to flow while turning the cartridge upside down several times. It will drain out air from inside the cartridge.
Mixing faucet (tap water)
Sink
Flexible pipe
Water distribution stopcock
Room temperature water supply pipe
Lever (control water flow)
"IN.OUT" hoses
Cartridge
Cartridge tray
One-touch joint (Hoses and filter connection parts)
Dedicated faucet (filtered water)
Installation example
Cartridge (model : UZC2000E)
Hot water
supply pipe
4. Irregular Water Flow
5. Names of Parts
Page 7
Operating the lever
Please use filtered water in the following situation
Cooking, Soups and other dishes, Coffee, Tea, Cleaning of raw vegetables,Making baby milk, and others
Please use tap water for dish washing.
Attention
Please be careful when you operate the lever. (If you close the lever with too much force, the pipes may be impacted, and it may result in damage and leakages)
Attention
Please ensure the wateroutlet is positioned/dirercted into the sink bowl, If positioned beyond the range of the sink, the flow may soak and damage furniture and other property.
Operating the wateroutlet pipe
The wateroutlet pipe can be moved 360
circularly. Adjust it to an appropriate position.
2. Extended cartridge life.
The cartridge life may vary depending on total amount of water flow, water quality and water pressure etc.
3. The one-touch joint system makes filter replacement easy.
1. Cleansui is a unique triple filtration system with high performance cartridge.
7
6. Features of Cartridge
7. Operating Instructions
Cartridge (model : UZC2000E)
Removes large particles.
Removes chlorine odour, 2-MIB (musty odour), organic matter (JIS designated items), trihalomethane, CAT (agricultural chemical), and lead dissolved in water.
0.1 micrometre holes on sidewalls of hollow fibre membrane can remove bacteria, rust, and solid lead etc.
Cleansui’s
unique
filtration
system
Non-woven fabric
Activated carbon and
ion exchange fibre
Hollow fibre membrane
(polyethylene)
The 1st filter
The 2nd filter
The 3rd filter
Minerals
Free residual chlorine
Turbidity(Rust, Bacteria etc.)
Trihalomethanes
Chloroform
Bromodichloromethane
Dibromochloromethane
Bromoform
Soluble Lead
CAT(chemicals/pesticides)
2-MIB(molds)
Tetrachloroethylene
Trichloroethylene
1,1,1-trichloroethane
1
2
3
4
5
6
7
8
9
10
11
12
13
The 3rd filter】
Hollow
fibre
membrane
The 1st filter
Non-woven
fabric
The 2st filter】
+
Activated
carbon
Ion
exchange
fibre
Tasty & clean water with minerals intact
ON
OFF
OFF
ON
Don’t apply
excessive pressure
spin 360
°
wateroutlet pipe
wateroutlet
Page 8
8
8. Maintenance
Please clean the wateroutlet with a sterilized soft
toothbrush.
Please wipe the product with a moist soft cloth and
then use a dry cloth to remove any remaining dirt.
If it is very dirty, use a soft cloth with neutral
detergent for first wipe, then wipe it with a wet cloth finally, remove remaining dirt with a dry cloth.
When cleaning it with a sponge that does not require detergent, please do not wipe any text or writing that appears on the product.
If dirt on the product is not cleaned immediately, it may be difficult to remove afterwards. In order to ensure the product is in optimum condition, we recommend that regular maintenance be performed on the product.
Please do not use the following items, as doing so may cause discolouration or other damage to it, and can cause property damage by leakage.
Detergents containing acid, alkaline or chlorineSolvents such as gasoline, lacquer thinners, lacquer,
alcohol and oil
Detergent containing abrasive compoundsNylon brushes
Attention
Regular Inspection
In order to use this system safely and effectively, please inspect it regularly.
Faucet loosening (About once a month)
If you continuously use a loose faucet, the stress may be applied to the pipes, and it may cause property damage by leakage.
Leakage around the pipes
(About once a month)
Please check for leakage around the pipes. The leakage is due to ageing and friction, may cause property damage.
Rotation of the wateroutlet pipe
(About once a month)
Rotate the wateroutlet pipe from side to side occasionally. If the wateroutlet pipe is not rotated for a long period of time, it may be affected by water stains which may subsequently affect its rotational capabilities.
No leakage
Check
Check if it is loose (rattling)
×
Loose (rattling)
Please rotate the wateroutlet pipe from side to side occasionally.
Page 9
9
Please replace the cartridge.
Please refer to P.10 “10. Replacing the Cartridge”
Please open or loosen the water stopcock.
Please refer to P.6 “5. Names of Parts”
Partially shut-off the water stopcock
Please refer to P.6 “5. Names of Parts”
Contact the store, distributor, contractor or manufacturer regarding part replacement.
Allow the filtered water to flow while turning the cartridge upside down a few times so as to drain out air from inside the cartridge.
Please refer to P.6 “4. Irregular Water Flow”
Reduced filtered water volume
The tap drips when turned off.
Water flow does not stop sharply when starting to use a new cartridge
Leakage in the connection between faucet and hoses
Leakage in the connection between faucet and hoses
Leakage in the faucet
No water flow
Unpleasant taste or odour.
Problem Potential causes Solution
Unsuitable components and lifespan.
Air is present in the cartridge.
The water stopcock is too tight or completely closed.
Unsuitable components and life span etc.
Water pressure is and volume are too high.
Cartridge is clogged.
If the tap continues to drip after you have
drained air from cartridge, it is caused by residual water inside the cartridge and is not a system malfunction.
9. Troubleshooting
Page 10
10
Protective cap
Plug
Green sticker)(Grey sticker)Green sticker)(Grey sticker)
③ ④
Slide ring (green)
The connecting order should be from green to grey. ③→④
4
Remove the upper protective caps of the new cartridge (2 pieces).
5
Connect the green and grey stickers of the new cartridge with the slide rings of matching colour, then press them together.
1
Close the faucet with the lever.
Attention
Ensure that the lever is closed before replacing cartridge.
(It may cause property damage by leakage.)
Occasionally, the water may leak a little, so please place a towel or a
washbasin under the cartridge. (It may cause property damage by leakage.)
Make sure that one-touch joint is plugged in completely when replacing
cartridge. (It may cause property damage by leakage.) (If it is connected incorrectly, it may produce blackened water (with activated
carbon) or cause damage or leakage.)
Make sure there is no irregularity such as leakage from the piping or
hoses, when replacing the cartridge. (It may cause property damage by leakage.)
After replacing the cartridge, please run the filtered water for at least
1 minute.
Cartridge Replacement Method
Replacement period of the cartridge
The replacement period will be approximately one year, but earlier replacement is recommended. Please replace the cartridge in the following situations.
“Filtered water” volume has significantly decreased.
Unpleasant taste or odour.
10. Replacing the Cartridge
Page 11
11
6
Run water by opening the lever handle. Ensure there are no leaks in the connection.
2
Pull the cartridge out towards yourself after removing it from the tray. Water may leak a little occasionally, so please place a towel or washbasin undo the cartridge.
3.
7.
Do not buckle or distort the hoses when placing into the cartridge tray.
The cartridge will rapidly become clogged up under the following conditions.
〉
1. Water supply facilities of the building are contaminated.
2. Pipes in old housing are deteriorating.
3. Tap water becomes contaminated temporarily because of pipeline construction.
4. A newly connected pipe has not been properly cleaned.
5. Water pressure is noticeably low
(high story building.)
Cartridge
One-touch joint
Slide ring (grey)
Plug (out)Plug (in)
Slide ring
(green)
Enlarged view of cartridge
(Green sticker)(Grey sticker)
Slide ring (grey)
② ①
Hoses
One-touch joint
To buy new cartridge, please contact the store where you bought Cleansui. Dispose of used cartridges in accordance with local waste regulations.
Green sticker
)(
Grey sticker
)
Pull up the slide ring (grey) with your finger, and then remove the one-touch joint from the cartridge. Remove the one-touch joint of the slide ring (green) with the same method.
The removal order should be from grey to green. ①→②
Pull up this
ring when
removing it
Page 12
12
11. After-sale Service
The Minimum Holding Period of Replacement Parts
The minimum holding period of replacement parts of this product is 10 years after production is
discontinued. The replacement parts are necessary to maintain the product's basic function, and it may be
necessary to replace them during the operational lifetime of the product.
Please note that it may be that only a substitute part is available, hence external appearance of the design or the design may differ
from the original.
Warranty
Cleansui comes with a warranty. The validity of the warranty is one year from the date of purchase, subject to term & conditions listed on warranty. Please see the warranty for details.
Abrasion and deterioration of parts may cause leakage, so some parts need to be replaced. Examples of parts which can be worn or deteriorated: check valves, rubber washers, shower hose and lever etc. By replacing parts when the parts are worn or deteriorated, the basic function of the product can be maintained.
Parts replacement
Page 13
13
Before asking for a Service (Maintenance or Repair)
1. Refer to section “9. Troubleshooting” and verify the details of the situation.
2. Having verified the situation details, please contact the store from which you purchased your product or the contractor who installed your water purifier.
3. When you make an inquiry, please inform them of the following points.
Product Name (Under sink water filter “Cleansui”)Set Number (A501ZCBE)Problems in detail
Replacement of Cartridge (Sold Separately)
1. Please contact the store or the contractor who installed the system
when you need to replace the cartridge or other parts.
2. you need to buy the cartridge, please quote specific model number: UZC2000E
3. Do not place or store the cartridge in locations subject to high temperatures (locations subject to direct sunlight, inside cars that are parked in direct sunlight, etc.) It is recommended to use the cartridge as soon as possible after opening.
Cartridge Model Number: UZC2000E
Page 14
14
12. Specifications
Faucet dimensions
Faucet dimensions Diametre of base Height of water wateroutlet Installation table thickness
Diametre 3640mm Diametre 50mm 188mm A501 325mm
Specifications
Cartridge Model Number
Set Number
UZC2000E
A501ZCBE
Cartridge components
Polyethylene hollow fibre membrane, ion exchange fibre,
activated carbon, non woven fabric
Initial water flow rate
3 litres / min
Filtration performance
Based on JIS S 3201
Free residual chlorine
Turbidity
Trihalomethanes
Chloroform
Bromodichloromethane
Dibromochloromethane
Bromoform
Soluble Lead
CAT(agrichemicals)
2-MIB (musty odour)
Tetrachloroethylene
Trichloroethylene
1,1,1-trichloroethane
40,000 litres (80% removed) 20,000 litres (50% filtration flow rate)
8,000 litres (80% removed)
8,000 litres (80% removed) 10,000 litres (80% removed) 10,000 litres (80% removed) 10,000 litres (80% removed) 10,000 litres (80% removed) 20,000 litres (80% removed) 20,000 litres (80% removed) 20,000 litres (80% removed) 20,000 litres (80% removed) 10,000 litres (80% removed)
Substances cannot be removed
Salt (seawater) or metallic ions (except lead) contained in water
Minimum working water pressure
0.07MPa
Dimensions of the cartridge
105mm (Maximum diameter)×217mm (Height)
Weight of the cartridge
(When filled with water)
800g (1400g)
Material
Cartridge
Faucet
Connecting Hose
ABS resin
Polyethylene
The estimated period of cartridge replacement (Based on JIS S 3201)
1 year (20 litres/day) (When the filtration performances on trihalomethanes
and chloroform decline to the levels mentioned above)
Copper
Page 15
12.A
Loading...