Side
IN
X
0
X
1
X
2
X
3
0
1
2
3
P
W
L
R
U
N
L
E
R
R
.
S
T
A
T
IO
N
N
O
.
ON
1)
Installation Removal
2)
3)
4)
CL1XY4-DT1B2
Connector for
CC-Link/LT
interface
External power
supply of the
input part
(24V DC)
Load
power
supply
. . .
DC DC
R
R
Y0
COM+
Y1
COM+
DC24V
DC24G
10
16
15
14
13
12
11
9
NC
NC
X0
COMB
X1
COMB
NC
NC
1
2
3
4
5
6
7
8
DC24A
DC24B
1
+24V
2
DA
3
DB
4
24G
Terminal block for I/O interface (positive common input)
Terminal block for I/O interface (sink output)
. . .
L
L
Isolation
B
Side
A
JAPANESE ENGLISH
Side
B
CL1XY4-DT1B2
CC-Link/LT Remote I/O Module
Please read this manual thoroughly before star ting to use the product and
handle the product properly.
User’s Manual
MODEL CL1XY4-DT1B2
MANUAL Number JY997D05601 E
Date September 2008
SAFETY PRECAUTIONS
●
Please read this m anual carefully a nd pay special atten tion to safely in order
to handle this product properly. Also pay careful attention to safely and handle
the module properly.
These precautions apply onl y to Mitsubishi equipment. Refer to th e user’s
manual of the CPU mo dule to use for a descr iption of the PLC system safety
precautions.
These ●SAFETY PRECAUTIONS● classify the safety precautions into two
categories: "DANGER" and "CAUTION".
DANGER
CAUTION
Depending on c ircumstances, procedures ind icated by
may also be linked to serious results.
In any case, it is important to follow the directions for usage.
Store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
[DESIGN PRECAUTIO NS]
• Configur e an interlock circuit in a sequence program so that the system
operates on the safety side usi ng the communication status information
in the event the data link falls into a communi cation problem.
Otherwise, erroneous outp ut and malfunction may result i n accidents.
• Remote input and output can not be switched ON or OFF when a
problem occurs in the remote I/O modules. Therefore build an exter nal
monitoring circuit that will monitor any input signa ls that could cause a
serious accident.
(Read these precautions before using )
Procedures which may lead to a dangerous c ondition
and cause death or serious injur y if not carried out
properly.
Procedures which may lead to a dangerous c ondition
and cause superficial to medium injur y, or physical
damage only, if not carried out properly.
DANGER
CAUTION
• Do not have control cables and communication ca bles bundled with or
placed near by the main c ircuit and/or power cables. Wire thos e cables
at least 100mm(3.94 inc h) away from the main circuit and/or p ower
cables. It may cause malfunction du e to noise interference.
• Use the m odule and the flat cable de dicated to CC-Link/LT without
applying any force on them.
Otherwise, such cables may be broken or fail.
[INSTALLATION PRECAUTIONS]
CAUTION
• Use t he module in an environment that meets the general specifications
contained in this manual . Using this module in an environment outside
the range of the general specifications could result in electric shock, fire,
erroneous operation, and damage to or deterio ration of the product.
• Do not directly touch the module 's conductive parts.Doing so could
cause malfunction or trouble in the module.
• Tighten the module securely using DIN rail or installation screws within
the specified torque range.
If the screws are too lose, the m odule may drop from its installa tion
position, shor t circuit, or malfunction. If the screws are too tight, the
screws may be damaged, which may cau se the module to drop fro m its
installation position or short circuit.
• Install the module on a flat surface.
If the mounting surface has conc ave and/or convex, an excessive force
may be applied on the module, and nonconformity may be cause d.
●
CAUTION
[WIRING PRECAUTIONS]
• Perform installation and wiring after discon necting the power supply at a ll
phases externally. If the power is not disconnected at al l phases an electric
shock or product damage may resul t.
DANGER
CAUTION
• Terminal screws which are not to be used must be tightene d always.
Otherwise there will be a danger of short c ircuit against the bare sol derless
terminals.
• Do no t perform wiring to an id le terminal "NC" outsid e the product.
The product may be damaged by suc h external wiring.
• Perform correct wiring for the modul e according to the product’s rated voltage
and terminal arrangement. Connecting to a power supply different from rating
or miss-wiring may cause f ire, product failure or malfunctio n.
• Fix ter minal screws securely withi n the regulated torque. Loos e terminal
screws may cause fire and/or malfunctio n.
If the terminal screws are t oo tight, it may cause shor t circuit or erroneo us
operation due to damage of the screws.
• Make sure foreign objects do not get inside the module, such as dir t and wire
chips. It may cause fire, product failure or ma lfunction.
• Attach a warning label (hazar d symbol 417-IEC-5036) concerning the ele ctric
shock to the location.
[STARTING AND MAINTENANCE PRECAUTIONS]
• Do no t touch the terminals when the power is ON. It may cause a n electric
shock or malfunction.
• Perform cleaning th e module or retightenin g of terminal screws after turning
OFF the all external power supply for sure. Failure to do so may cause failure
or malfunction of the modules
DANGER
CAUTION
• Do no t disassemble or modify the module. Doing so may cause failure,
malfunction, injur y, or fire.
• The module case is made of resin; do not drop it or subject it to strong shock.
A module damage may result.
• Make sure t o switch all phases of the exter nal power supply OFF before
installing or removing the mod ule to/from the pane l. Failure to do so may
cause failure or malfunction of th e modules.
[DISPOSAL PR ECAUTIONS]
• When d isposing of this produ ct, treat it as industri al waste.
[TRANSPORTATION AND MAINTENANCE PRECAUTIONS]
• Dur ing transportation avoid any impact as the module is a precision
instrument. Doing so cou ld cause trouble in the mod ule.
• If is n ecessary to check the ope ration of module after t ransportation, in cas e
of any impact damage.
Notification of CE marking
This notification does not guarantee that an entire mechanical modul e produced
in accordance with the contents of the notification comply with the following
standards. C ompliance to EMC standards of the ent ire mechani cal module
should be checked by the user / ma nufacturer.
Standards with which this product complies
Type : Programmable Controller (Open Type Equipment) Remote I/O module
Models : Products manufactured:
from February 1st , 2003 to April 30th, 2006 are compliant with
EN61000-6-4 and E N61131-2:1994+A11:19 96+A12:2000
after May 1st, 2006 are compl iant with EN61131-2:200 3
Electromagnetic Compatibility
EN61000-6-4:2001
Electromagnetic compatibilit y
-Generic standards - Emission
standard for Industrial environment
EN61131-2:1994/A11:1 996/A12:2000
Programmable controllers
-Equipment requirements and tests
EN61131-2: 2003
Programmable controllers
-Equipment requirements and tests
For more details please conta ct the local Mitsubishi Ele ctric sales site.
- Notes For compliance to EMC re gulation.
It is necessary to install th e CL1 series module in a shielded metal control panel.
●
Standards (EMC)
DANGER
CAUTION
●
Remark
Compliance with all relevant aspects of
the standard.
(Radiated Emissions and M ains Terminal
Voltage Emissions)
Compliance with all relevant aspects of
the standard.
(RF Immunity, Fast transients, ESD and
Damped oscillator y wave)
Compliance with all relevant aspects of
the standard.
(Radiated Emissions, Mains Terminal
Voltage Emissions, RF immunity, Fast
Transients, ESD, Surge, Voltage drops
and interruptions, Conduct ed and Power
magnetic fields)
1. Outline of Product
This product is a terminal block type
composite I/O module connecte d to
CC-Link/LT.
This product has four input points (24
VDC) and four output points (transistor
output).
2. Name and Setting of Each Part and Terminal Arrangement
DIP switch
DIP switch assignment
40 20 10 8 4 2 1
ON
Connector for
CC-Link/LT interface
Connector terminal
assignment
24G
4
3
DB
DA
2
+24V
1
Orange color
HLD
Status indicator
CL1XY4-DT1B2
LINK/PW
2-φ4.5 mounting hole
(M4 mounting screw)
Terminal arrangement (Terminal number and Signal name)
1
DC
DC24A
24A
2
DC24B
PW
X0
X1
Y0
Y1
3X05X17NC9NC11Y013Y115
X0 X1 NC Y1
X0 X1
4
DC
X0 X1 NC Y1
COMB6COMB8NC
24B
Name Description
PW ON while the power is supplied.
L RUN ON while normal operation is executed.
ON:When a communication erro r or DIP switch
setting error occurred
Flickering at a constant inter val:
Status indicator
LEDs
I/O operation
indicator LEDs
Connector for CCLink/LT interface
Terminal block
for I/O interface
Station number
setting switches
When the setting of the DIP switch was changed
while the power was supplied (even while the LED is
flickering, the operation continues. The new setting
L ERR.
becomes valid when the power is turned OF F once,
then ON again.)
Flickering at a intermittent inter val:
When a terminal resis tor is not attached or when the
module or a connection cable is affected by noise
ON while the input or output
is ON. Extinguished while
the input or output is OFF.
Connector for CC-Link/LT communication line/module power
supply (24G/DB/DA/+24V)
Terminal block to connect input signals, output signals, I/O
power supply and load power supply
Set the 10's digit of the station No. using "STATIO N NO. 10",
"STATION NO. 20" and "STATION NO. 40". Set the 1's dig it of
the station No. using "STATION NO. 1", "STATION NO. 2",
"STATION NO. 4" and "STATION NO. 8".
Factory default = All bits are OFF.
Make sure to set the station No. in the range from 1 to 64.
If any station No. outside the range from 1 to 64 is set, it is
regarded as an error and the L ERR. LED lights.
Example: When setting the station No. to "32", set the
DIP switch as follows.
Station
No.
32 ONOFFONOFF ON OFF OFF
Input operation
indicator LEDs
Input/output is ON: Lit
LEDs
Input/output is OFF
: Extinguished
ON
IN
OUT
Terminal block for I/O interface
Hook for installation to DIN rail
NC NCNCY0
COMB NC
40 20 10 8 4 2 1
10 12
Input operation
indicator
10's digit 1's digit
0101
Output operation
indicator LEDs
01L RUN L ERR.
01
40 2010 8 4 2 1
DC
DC24V
24V
COM+Y1COM+
COM+14COM+16DC24GNC
01 01
Output operation
indicator
DC
24G
Name Description
Response time
setting switch
Holds the output ( when an error ha s occurred).
HLD
ON: Holds the output.
OFF: Clears the output.
3. Installation
The CL1XY4-DT1B2 can be installed to DIN rail or directly installed using
mounting screws.
Each installation proc edure is described b elow.
3.1 Installation to DIN rail
Align the upper DIN rail installation groove in the module with the DIN rail
1), and press the mod ule in that status 2).
When removing the module, pull the hook downward for installation to DIN
rail 3), then remove the module 4).
DIN rail mounting screw pitch
When installing the module to the DIN rail, tighten the mounting screws at
the pitch of 200mm(7 .87") or less.
Applicable DIN rail TH35-7.5Fe and TH35-7.5AI
3.2 Direct installation
Screw-tighten the module by attaching M4 screws to the upper and lower
mounting holes (two hole s in all) provided in the modu le.
Install the module so that the clearance of 1 to 2mm (0.04" to 0.08") is
assured for each module.
Applicable screw
0.7mm(0.03") × 16mm(0.63") or more
M4
×
(Tightening torque range: 78 to 108 N⋅cm)
4. Wiring
4.1 External wiring
The input terminals of the CL1XY4-DT1B2 can be wired as positive
common or negative common depending on the used sensor. (The output
wiring is fixed to the sink o utput.)
Positive common

IN
X
0
X
1
X
2
X
3
0
1
2
3
P
W
L
R
U
N
L
E
R
R
.
S
T
A
T
IO
N
N
O
.
ON
1)
Installation Removal
2)
3)
4)
CL1XY4-DT1B2
Connector for
CC-Link/LT
interface
External power
supply of the
input part
(24V DC)
Load
power
supply
. . .
DC DC
R
R
Y0
COM+
Y1
COM+
DC24V
DC24G
10
16
15
14
13
12
11
9
NC
NC
X0
COMB
X1
COMB
NC
NC
1
2
3
4
5
6
7
8
DC24A
DC24B
1
+24V
2
DA
3
DB
4
24G
Terminal block for I/O interface (positive common input)
Terminal block for I/O interface (sink output)
. . .
L
L
Isolation
Negative common
2 - φ4.5(0.18") mounting
hole (M4 mounting screw)
Center of DIN rail
49(1.93")
4.5
(0.18")
40(1.58")
40(1.58")
10(0.40")
80(3.15")
22(0.87")
71.5(2.82") ± 0.6(0.03")
6(0.24") 6.5(0.26")
41(1.62")
±
0.4(0.02")
Unit: mm(inches)
4
T
External power supply
of the input part
(24V DC)
Terminal block for I/O interface (Negative common input/sink output)
DC24A
1
2
DC24B
Wire nothing to the NC ter minal (idle term inal).
4.2 Connection to sensor
Positive common (NPN)
• When using a two-wire type sensoryWhen using a three-wire type sensor
Connected to DC 24A terminal
Bleeder resistor *1
Detection
circuit
Sensor (NPN)
• When us ing a three-wire type se nsor
(when using the power supp ly for sensor other than 24V DC)
Detection
circuit
X *
COMB
X *
COMB
Negative common (PNP)
• When using a two-wire type sensoryWhen using a three-wire type sensor
Connected to DC 24A terminal Connected to DC 24A terminal
Bleeder resistor *1
Detection
circuit
Sensor (PNP)
• When us ing a three-wire type se nsor
(when using the power supp ly for sensor other than 24V DC)
Detection
circuit
X *
COMB COMB
X *
COMB
Replace * in the figure with the used input No.
Notes:
*1 Bleeder resistor
When connecting a two-wire type sensor or input equipment containing a
parallel resistor, select a sensor or equipment whose leakage current is
1.7mA or less.
If the leakage current is more than 1.7mA, connect a bleeder resistor
obtained in the following calculation formula.
Circuit image
R(kΩ) < 1.7(mA) / Leakage current(mA) - 1.7( mA) x 5.6(kΩ)
The power capacity W of the bleeder resistor R is as follows:
W = (Input voltage)
• Make sur e that both the ON and OFF time of the input s ignal are 1.5ms or
more.
Leakage
Unit
24V DC
current
R
2
/R
Sensor (NPN)
Detection
circuit
Connected to DC 24A terminal
Detection
circuit
Detection
circuit
Input impedance
5.6 kΩ
1.7 mA or less
R: Bleeder resistor
X *
COMB
X *
4.3 Crimp-style terminal
For I/O wiring, use crimp- style terminals of the following dimensions.
φ
3.2 (0.13")
Crimp-style
terminal
6.2 mm (0.24" )
Terminal
2
or less
Terminal screw
6.2 mm (0.24" )
or less
When wiring one cable to one terminal When wiring two cables to one terminal
Terminal scre w
Terminal
Applicable crimpstyle terminal
Applicabl e wire size
• RAV1.25-3
• V 1.25-3 (manufactured by JST M fg. Co., Ltd.)
• 1.2 5-3 and TG1.25-3
(manufactured by NICHIFU Co., Ltd.)
0.3 to 1.25 mm
φ
3.2 (0.13")
Crimp-style
terminal
Use a crimp-style termi nal in a status in which no force is applied on the cable.
4.4 Module terminal screw
Tighten the termina l screws (M3 screws) on the terminal block with a tigh tening
torque of 42 to 58 N⋅cm.
5. Specifications
5.1 General specifications
Item Specification
Operating
ambient
temperature
Storage ambient
temperature
Operating
ambient
humidity
Storage ambient
humidity
Vibration
resistance
Shock
resistance
Operating
ambience
Operating
altitude
Installation
location
Overvo ltage
category
Pollution level
Notes:
*1 The module cannot be used in an environment pres surized above the
atmospheric pressur e which can be generated arou nd the altitude of 0 m. If the
module is used in such an environmen t, it may fail.
*2 The module can be used in any environment even outside the con trol panel as
far as the requir ements of the ambient op erating temp erature, the a mbient
operating humidity, etc. are satisfied.
*3 This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within premises. Category ΙΙ applies to equipment
for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300V is 2500V.
0 to 55°C (32 to 131°F)
-25 to 75°C (-13 to 167°F)
5 to 95%RH: Dew condensation shall not be considered.
5 to 95%RH: Dew condensation shall not be considered.
When intermittent vibration is present
Frequency
10 to 57Hz
57 to 150Hz
Acceleration Half amplitude
0.075mm
−
2
9.8m/s
When continuous vib ration is present
Frequency
10 to 57Hz
57 to 150Hz
147 m/s
Acceleration Half amplitude
0.035mm
−
2
4.9m/s
2
, 3 times in each of X, Y and Z directions
Number of times of
sweep
−
10 times in each of
X, Y and Z directions
(for 80 min)
−
Corrosive gas shall not be present.
2,000m(6561'8") or less (*1)
Inside control panel (*2)
or less (*3)
ΙΙ
2 or less (*4)
*4 This index indicates th e degree of conductive generating subst ances in the
environment in which the module is used. The degree of contamination 2
indicates that contamination is caused by generation of only non-conductive
substances.
In this degree, however, temporary conduction may be caused by accidental
condensation.
5.2 Input specifications
Input method
Item Specification
Number of inputs
Isolation method
Rated input voltage
Rated input curren t
Operating voltage range
Max. simultaneous ON
input points
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
OFF→ON
ON→OFF
Common wiring method
DC input (external I/O power supply)
2 points
Isolation with photocoupler
24V DC
Approx. 4 mA
20.4 to 28.8V DC (24V DC -15% to +20% )
Ripple ratio: Within 5%
100% (at 24V DC)
19 V or more/3 mA or more
11 V or less/1.7 mA or less
5.6 k
Ω
1.5 ms or less (at 24V DC)
1.5 ms or less (at 24V DC)
2 points/1 common (2 points)
(terminal block two-wire type)
5.3 Output sp ecification s
Output method
Item Specification
Number of outputs
Isolation method
Rate d load voltage
Operating load voltage
range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Response
time
OFF→ON
ON→OFF
Surge suppression
Common wiring method
Internal protection for
outputs
Transistor output (external I/O power supply) (sink)
2 points
Isolation with photocoupler
12/24V DC
10.2 to 28.8V DC ( Ripple ratio: Within 5 %)
0.1A/point, 0.4A/1commo n
0.4A/10 ms
0.1mA or less/30V DC
0.3V or less (typical)/0.1A
0.6V or less (max.)/0.1A
1.0ms or less
1.0ms or less
Zener diode
2 points/1 common (2 points)
(terminal block two-wire type)
Internal protect ion circuit none
Please connect the fuse in the connec ted load
outside.
5.4 Performance specifications
Item Specification
Vol t a ge
Current consumption
Module
power
supply
Number of stations
occupied
Initial current
Max. allowable
momentary power
failure period
Noise durability
Withstand voltage
Isolation resistance
Protection class
I/O part connection method
Module installation method
Mass (weight)
20.4 to 28.8V DC (24V DC -15% to +20%)
Ripple ratio: Within 5%
55mA (when all points are ON)
70mA
PS1:1ms
4-, 8- or 16-poi nt mode: 1 station
500Vp-p
Noise width: 1µs Cycle: 25 to 60 Hz
(by noise simulator)
DC type: 500V AC for 1 min
10 MΩ or more between primary area (external DC
terminal) and seconda ry area (internal c ircuit) by
500 VDC megger
IP2X
Connection with term inal block
DIN rail installation, mounted by screws of type
M4 × 0.7mm(0.03") × 16mm(0.63") or larger
Can be installed in six directions
0.1kg(0.22lbs)
6. Outside Dimensions
This manual confers no industrial property rights or any rights of any other kind, nor
does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held
responsible for any problems involving industrial property rights which may occur as
a result of using the contents noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the
cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi
products; damage, secondary damage, accident compensation caused by special
factors unpredict able by Mitsubishi ; damages to pro ducts other th an Mitsubishi
products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in a
device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power,
aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However when
installing the product where major accidents or losses could occur if the product
fails, install appropriate backup or failsafe functions in the system.
Country/Region Sales office/TelCountry/Region Sales office/Tel
U.S.A.
Mitsubishi Electric Automation, Inc.
500 Corporate Woods Parkway, Vernon
Hills, IL 60061 U.S.A.
Tel : +1-847-478-2100
Brazil
MELCO-TEC
Av. Paulista 1439, conj.74, Bela Vista CEP:
01311-200 Sao Paulo-SP-Brazil
Tel : +55-11-3285-1840
Germany
Mitsubishi Electric Europe B.V. German
Branch
Gothaer Strasse 8, D-40880 Ratingen,
Germany
Tel : +49-2102-486-0
U.K.
Mitsubishi Electric Europe B.V. UK
Branch
Travellers Lane, Hatfield, Hertfordshire.,
AL10 8XB, U.K.
Tel : +44-1707-276100
Mitsubishi Electric Europe B.V. Italian
Italy
Branch
VIALE COLLEONI 7-20041 Agrate Brianza
(Milano), Italy
Tel : +390-39-60531
Mitsubishi Electric Europe B.V. Spanish
Spain
Branch
Ctra. de Rub 76-80-AC. 420, E-08190 Sant
Cugat del Valles (Barcelona), Spain
Tel : +34-93-565-3131
Mitsubishi Electric Europe B.V. French
France
Branch
25, Boulevard des Bouvets, F-92741
Nanterre Cedex, France
Tel: +33-1-55685568
Mitsubishi Electric Europe B.V. Moscow
Russia
Representative Office
52, bld. 5, Kosímodamianskaya nab,
RU-115054, Moscow, Russia
Tel: +7-495-721-2070
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy,
Trade and Industry for service transaction permission.
Hong Kong
Mitsubishi Electric Automation
(Hong Kong) Ltd.
10th Floor., Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870
China
Mitsubishi Electric Automation
(Shanghai) Ltd.
17F, ChuangXing Financial Center,
No. 288 West Nanjing Road, Shanghai
China 200003
Tel : +86-21-2322-3030
Tai wa n
Setsuyo Enterprise Co., Ltd.
6F No.105 Wu Kung 3rd RD, Wu-Ku
Hsiang, Taipei Hsien, 248, Taiwan
Tel : +886-2-2299-2499
Korea
Mitsubishi Electric Automation Korea Co.,
Ltd.
3F, 1480-6, Gayang-Dong, Gangseo-Gu,
Seoul, 157-200, Korea
Tel : +82-2-3660-9552
Singapore
Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02
Mitsubishi Electric Building,
Singapore 159943
Tel : +65-6470-2460
Thailand
Mitsubishi Electric Automation (Thailand)
Co., Ltd.
Bang-Chan Industrial Estate No.111,
Soi Serithai 54, T.Kannayao, A.Kannayao,
Bangkok 10230
Tel : +66-2-517-1326
India
Messung Systems Pvt. Ltd.
Sapphire House EL-3 J-Block MIDC
Bhosari Pune 411026, India
Tel : +91-20-27102000
Australia
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, Rydalmere, N.S.W
2116, Australia
Tel : +61-2-9684-7777
South Africa
Circuit Breaker Industries Ltd.
Private Bag 2016, ZA-1600 Isando,
South Africa
Tel : +27-11-9282000
Specifications subject to change without notice.