The brand new 22-7/16 inch PLFY-P08/12/15NCMU-E models are slim, attractive, yet poweful units.
PLFY-P08/12/15NCMU-E’s size and shape, which perfectly match 2-by-2 ceilings, and its lighter weight of 34 lbs
(PLFY-P08NCMU-E) make installation even easier and more convenient.
2. 29 dB WHISPER-QUIET OPERATION (PLFY-P08NCMU-E)
Ideal for cafés, bars, restaurants, and shops. Give all your customers the comfortable environment they deserve.
3. 2,500 HOUR LONG LIFE FILTER
Greatly reduces the frequency the filter needs to be replaced, making maintenance all the easier.
4. FRESH AIR INTAKE
Provides indoor air of the highest quality.
5. SMUDGE-FREE AIRFLOW
Reduces annoying drafts and smudging.
6. SLIM UNIT BODY FOR EASY INSTALLATION
The 22-7/16 inch slim body and octagonal shape, which make the distance between bolts only 16-17/32 inch, help installation easy and maintenance trouble-free.
Unit : inch
20-7/8
Suspension bolt pitch
16-17/32
Unit 22-7/16
22-7/16
T-bar
22-11/16
23-5/8
Ceiling surface
8-3/16
9-1/4
3
3
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACKDAY
MONITOR/SET
CLOCK
ON/OFF
Temperature setting buttons
Down
Up
Timer Menu button
(Monitor/Set button)
Mode button (Return button)
Set Time buttons
Back
Ahead
Timer On/Off button
(Set Day button)
Opening the
lid
ON/OFF button
Fan Speed button
Filter button
(<Enter> button)
Test Run button
Check button (Clear button)
Airflow Up/Down button
Louver button
( Operation button)
To return operation
number
Ventilation button
( Operation button)
To go to next operation
number
Built-in temperature sensor
PART NAMES AND FUNCTIONS
Indoor (Main) Unit
Horizontal Air Outlet
Sets horizontal airflow automatically
during cooling or dehumidifying.
Filter
Removes dust and pollutants
from return air.
Grille
Auto Air Swing Vane
Disperses airflow up and
down and adjusts the angle
of airflow direction.
Air Intake
Returns air from room.
Wired remote controller
Once the controllers are set, the same operation mode can be repeated by simply pressing the ON/OFF button.
4
Wired remote controller
Display Section
For purposes of this explanation,
all parts of the display are shown
as lit. During actual operation, only
the relevant items will be lit.
Identifies the current operation
Shows the operating mode, etc.
*Multilanguage display is available.
“Centrally Controlled” indicator
Indicates that operation from the
remote controller has been prohibited by a master controller.
“Timer is Off” indicator
Indicates that the timer is off.
Temperature Setting
Shows the target temperature.
Day-of-Week
Shows the current day of the week.
Time/Timer Display
Shows the current time, unless the simple or Auto Off
timer is set.
If the simple or Auto Off timer is set, the time to be
switched off is shown.
TIME SUN MON TUE WED THU FRI SAT
TIMER
AFTER
ERROR CODE
°F°C
Hr
AFTER
°F°C
ONLY1Hr.
Up/Down Air Direction indicator
Shows the direction of the
outcoming airflow.
“One Hour Only” indicator
Displayed if the airflow is set to
low or downward during COOL
or DRY mode. (Operation varies
according to model.)
The indicator goes off in one hour,
when the airflow direction also
changes.
Room Temperature display
Shows the room temperature. The room
temperature display range is 46~102°F.
The display blinks if the temperature
is less than
Louver display
Indicates the action of the swing louver.
Does not appear if the louver is not
running.
(Power On indicator)
Indicates that the power is on.
ON
OFF
FUNCTION
FILTER
WEEKLY
SIMPLE
AUTO OFF
46°F or 102°F
or more.
“Sensor” indication
Displayed when the remote controller
sensor is used.
“Locked” indicator
Indicates that remote controller buttons have been locked.
“Clean The Filter” indicator
To be displayed on when it is time to
clean the filter.
Timer indicators
The indicator comes on if the corresponding timer is set.
Fan Speed indicator
Shows the selected fan speed.
Ventilation indicator
Appears when the unit is running in
Ventilation mode.
Note:
●
“PLEASE WAIT” message
This message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the unit is recovering from a power failure.
●
“NOT AVAILABLE” message
This message is displayed if an invalid button is pressed (to operate a function that the indoor unit does not have).
If a single remote controller is used to operate multiple indoor units simultaneously that are different types, this message will not be displayed as
far as any of the indoor units is equipped with the function.
5
4
SPECIFICATIONS
4-1. SPECIFICATIONS
Item
Power
Cooling capacity
Heating capacity
Cooling
Input
Heating
Cooling
Current
Electric characteristic
(munsell symbol)
Dimensions
Heat exchanger
F a n
Pipe
dimensions
Field drain pipe size
Noise level 3
Product weight
Heating
Exterior
Height
Width
Depth
Fan × No.
Air flow
DRY
3
WET
External
static pressure
Fan motor
output
Insulator
Air filter
Gas
side
Liquid
side
V·Hz
Btu/h
Btu/h
kW
kW
A
A
—
in
in
in
—
—
CFM
CFM
Pa
kW
—
—
in
in
in
dB
lb
PLFY-P08NCMU-E.TH
PLFY-P08NCMU-E
1.TH
PLFY-P08NCMU-ER2.TH
8,000
9,000
0.05
0.05
0.23
0.23
Unit : Galvanized sheets with gray heat insulation
Note 1. Rating conditions
Cooling : Indoor : D.B. 80°F W.B. 67°F
outdoor : D.B. 95°F W.B. 75°F
Heating : Indoor : D.B. 70°F
outdoor : D.B. 47°F W.B. 43°F
Note 2. The number indicated in < > is for the grille.
W 3. Air flow and the noise level are indicated as Low - Medium - High.
12,000
13,500
0.06
0.06
0.28
0.28
8-3/16<25/32>
22-7/16<25-19/32>
22-7/16<25-19/32>
Cross fin
Turbo fan × 1
0
Polyethylene sheet
PP honey comb fabric
1/2"
1/4"
O.D1-1/4"
30-34-39
PLFY-P15NCMU-E.TH
PLFY-P15NCMU-E1.TH
PLFY-P15NCMU-ER2.TH
15,000
17,000
0.06
0.06
0.28
0.28
1/ER2.TH)
320-350-390
290-320-350
0.020
31-35-40
37<7>
6
4-2. NOISE CRITERION CURVES
PLFY-P08NCMU-E.TH
PLFY-P08NCMU-E
1.TH
PLFY-P08NCMU-ER2.TH
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar)
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000200040008000
BAND CENTER FREQUENCIES, Hz
NOTCH
High
Medium
Low
SPL(dB)32LINE
38
29
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
PLFY-P12NCMU-E.TH
PLFY-P12NCMU-E
1.TH
PLFY-P12NCMU-ER2.TH
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar)
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000200040008000
BAND CENTER FREQUENCIES, Hz
NOTCH
High
Medium
Low
SPL(dB)34LINE
39
30
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
PLFY-P15NCMU-E.TH
PLFY-P15NCMU-E
1.TH
PLFY-P15NCMU-ER2.TH
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar)
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000200040008000
BAND CENTER FREQUENCIES, Hz
NOTCH
High
Medium
Low
SPL(dB)35LINE
40
31
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
UNIT
CEILING
5ft
MICROPHONE
NOTE: The sound level is measured in an anechoic
room where echoes are few, when compressor stops. The sound may be bigger than the
indicated level in actual use due to surrounding echoes. The sound level can be higher by
about 2 dB than the indicated level during cooling and heating operation.