Mitsubishi Electric City Multi PKFY-P12NHMU-E2 Features

Model: PKFY-P12NHMU-E2
Job Name: Location:
Drawing Reference: Schedule No.
System No.: Date:
GENERAL FEATURES
R410A refrigerant
Seven sizes from 6,000 to 30,000 Btu/h
Powerful airow (CFM)
Compact, lightweight, shiny-white, at-panel design
Quiet operation
Intake grille filter is easily removed for cleaning
Built-in receiver is standard
IT Terminal plug
SPECIFICATIONS
Capacity*
Cooling…………………………………………….…12,000 Btu/h
Heating…………………………………………….…13,500 Btu/h
Net Weight
Unit………………..…...……………..................29
Coil Type………………...........................................….Cross Fin
Fan
Type x Quantity………………..…………...Line Flow Fan x 1
Airow Rate (Low-Mid-High)...…….……...........370 - 413 CFM
Motor Type………..………..………..… Output………..………..………..………..………..….0.030 kW
Air Filter..…………………………….Polypropylene Honeycomb
Refrigerant Piping Dimensions
Liquid (High Pressure)……............…1/4" /
Gas (Low Pressure)………………..
Drainpipe Dimension……............……...…….I.D. 5/8" / 16 mm
Sound Pressure Levels
Low-Mid-High….…………….………..........……39 - 43 dB(A)
OPTIONS
External Heat Adapter……………………….…PAC-YU25HT
* Cooling / Heating capacity indicated at the maximum value at
Cooling: Indoor 80°F (27°C) DB / 67°F (19°C) WB, Outdoor 95°F
Heating: Indoor 70°F (21°C) DB, Outdoor 47°F (8°C) DB / 43°F (6°C) WB
operation under the following conditions:
(35°C) DB
(Aluminum Plate Fin and Copper Tube)
……..Direct-drive DC Motor
…1/2" / 12.7 mm (Flare)
lbs. / 13 kg
6.35 mm (Flare)
Power
Power Source………………..........208 / 230V,
Power Consumption
Cooling…………………………………………….………0.03 kW Heating…………………………………………….………0.03 kW
Current
Cooling……...................................................……………0.30 A
Heating……...................................................……………0.30 A
Minimum Circuit Ampacity (MCA)……………….…..……...0.38 A
Maximum Overcurrent Protection (MOCP) Fuse..….......…..15 A
External Finish……………...….………Munsell No. 1.0Y 9.2 / 0.2
External Dimensions
Inches………………………..11-5/8 H x 35 -3/8 W x 9-13/16 D mm………………………………………295 H x 898 W x
Notes:
1-phase, 60Hz
249 D
Note: Ventilation air: Providing suf cient ventilation air is an impor-
tant part of every building design. ASHRAE Standard 62 provides
the minimum ventilation air requirement. Also, check local codes.
Model: PKFY-P12NHMU-E2 – DIMENSIONS
Sleeve (purchased locally)
~
2-1/2
3-1/8
~
80)
( 65
D
Left side
Knock out hole for left piping
Through hole
2-1/2~ 3-1/8
~
( 65
80)
Knock out hole for lower piping
5/8(16)
1-1/16(28.5)
1-9/16(41)
3-1/16(78.5)
3-9/16(91)
4-1/16(103.5)
4-9/16(116)
6-1/2(166)
8(203.5)
9-1/8(232.5) 9-15/16(253.5)
7-3/4(197)
77- 3/16( 5.1) Tapping screw hole
0
7(178.5)
Wall hole for left rear piping
11-9/16(295)
2-1/8 (55)
5/16(8)
Vane(auto)
C
14-5/8(372.3)
14(356.3)
15-1/2(394)
17-5/8(449)
15-3/16(387)
24-1/16(612)
Louver(manual)
4- 5/16( 9) Bolt hole
12-7/8(327.5)
10-3/8(265)
11-7/16(291.5)
7-13/16(200)
8-13/16(225)
8-3/8(213)
9-5/16(238)
6-13/16(174)
10-15/16(278.3)
23-9/16(599)
27-1/16(688)
35-5/16(898)
Front side(Grille open)
17-15/16(457)Gas pipe
21-3/16(539)Liquid pipe
24(610)Drain hose
Under side
Knock out hole for lower piping
0
4-7/8(125)
2-3/4(70)
0
9/16(15)
0
Knock out hole for left rear piping 2-3/4×12-3/16(70×310)
7-1/2(192)
Operation lamp
Center measurement hole 3/32( 2.5)
Mount board
2-1/4(58)
5/32(3.8)
9-5/16(238)
8-13/16(225)
2-3/4(70)
4-1/2(115)
4-7/8(125)
5-1/2(140)
6-9/16(167)
7-1/16(180.3)
7-13/16(200)
7-9/16(193.5)
9/16(15)
Top side
Front side
6-1/16(155)
6-5/8(169) 6-3/16(158)
7-3/16(184)
B
12-7/8(237.5)
11-7/16(291.5)
10-3/8(265)
11-1/16(281)
Terminal block for power supply
Terminal block for transmission
Emergency operation switch (cooling/heating)
DEFROST/STAND BY lamp
Refrigerart Piping
Receiver
Indoor unit outline
14-5/8(372.3)
14(356.3)
17-5/8(449)
Wall hole for right rear piping
Knock out hole for right piping
Terminal block for MA-remote controller
Liquid pipe
Gas pipe
Drain hose
13/16(21.8)
0 3/4(20)
1-1/4(32.7) 2-1/16(53.5) 2-9/16(66)
5(128.5) 6(153.5)
9-1/16(231.5)
10-3/4(273.2)
Unit : in(mm)
Mount board
Right side
A
3/16(5)9-3/4(249)
1/4F ( 6.35)
1/2F ( 12.7)
5/8 ( 16) I.D
Knock out hole for piping
C
2-3/16(56)7/16(12.5)
1-11/16(43)
2-3/16(56)
1-3/4(46)
3/16(6)
1-11/16(43)
A
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired ISO
based on a review of quality warranties for the production of refrigeration and air conditioning equipment.
ISO Authorization System The ISO 9000 series is a plant authorization system relating to quality warranties as
development, production, installation and auxiliary services" for products built at an authorized plant.
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmental
The ISO 14000 series is a set of standards applying to environmental protection set by the International Standard Organization (ISO).
2-11/16(69)
1-3/4(46)
2-3/16(56)
3/16(6)
2-5/16(60)
1-11/16(43)
D
1-11/16(43)
B
2-5/16(59)
Min.1/4(7)
250mm,9-13/16inch or greater with
optional drain pump installation.
Required space(Indoor unit)
Min.1-31/32(50)
(mm)
Air inlet
Air inlet
Air outlet
Min.8-5/8
(220)
Min.5-7/8(150)
Mitsubishi Electric Sales Canada Inc.
Min.1-31/32(50)
Min.9-13/16(250)
www.MitsubishiElectric.ca
Specifications are subject to change without notice.
SB_PFY-P12NHMU-E2_201205